• Title/Summary/Keyword: friction capacity

Search Result 469, Processing Time 0.03 seconds

A Study on the Antistatic characteristics of Antistatic Garments for the Prevention of Static Electricity Hazards (정전기 재해예방을 위한 제전복의 제전특성에 관한 연구)

  • 정재희
    • Journal of the Korean Society of Safety
    • /
    • v.5 no.1
    • /
    • pp.57-66
    • /
    • 1990
  • The purpose of this study is to investigate electrostatic charge condition and possibility of electrostatic hazards in case of putting on synthetic smocks and antistatic garments for the purpose of prevention of electrostatic hazards due to a human body electrical charge. It is shown in case of a synthetic smocks, electrostatic voltage by friction is about 2,900 (V), half life period is 12 second, and electrostatic charge is 1.4―1.8 ($\mu$ C). When putting on a synthetic smocks, electrostatic voltage is 2,500―2,800(V). When putting on a jumper of chemical fiber, electrostatic voltage is 8,000(V) . It is, therfore, possible to cause a electrostatic hazards. It is also shown in case of a antistatic garments, electrostatic voltage by friction is 87(V) ―280(V) (washing 90 times), half life period is 3―5 second, and electrostatic charge is 0.24―0.28($\mu$ C) which is much lower than 0.6($\mu$ C) limitation of fire and explosion occurance. When putting on a antistatic garments, electrostatic voltage is 10(V) ―125(V). In conclusion, it is shown when putting on a antistatic garments it is possible to prevent a electrostatic hazards such as fire or explosion due to human body, to prevent a destruction of semiconductor elements and capacity decline, and to prevent a misoperation of automation facilities and semiconductor electric and electronic products.

  • PDF

A Study on the Structural Stiffness and Coulomb Damping of Air Foil Bearing Considering the Interaction among Bumps (범프들의 상호작용을 고려한 공기 포일 베어링의 구조적 강성 및 쿨롱 감쇠에 대한 연구)

  • Park, Dong-Jin;Kim, Chang-Ho;Lee, Sung-Chul;Lee, Yong-Bok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1135-1141
    • /
    • 2006
  • Air foil bearing supports the rotating journal using hydrodynamic force generated at thin air film. The bearing performance, stiffness, damping coefficient and load capacity, depends on the rotating speed and the performance of the elastic foundation, bump foil. The main focus of this study is to decide the dynamic performance of corrugated bump foil, structural stiffness and Coulomb damping caused by friction between bump foil and top foil/bump foil and housing. Structural stiffness is determined by the bump shape (bump height, pitch and bump thickness), dry-friction, and interacting force filed up to fixed end. So, the change of the characteristics was considered as the parameters change. The air foil bearing specification for analysis follows the general size; diameter 38.1 mm and length 38.1mm (L/D=1.0). The results show that the stiffness at the fixed end is more than the stiffness at the free end, Coulomb damping is more at the fixed end due to the small displacement, and two dynamic characteristics are dependent on each other.

  • PDF

Development of New Micropiling Technique and Field Installation (신개념 마이크로파일 개발 및 현장시험시공)

  • Choi, Chang-Ho;Goo, Jeong-Min;Lee, Jung-Hoon;Cho, Sam-Deok;Jeong, Jae-Hyeong
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.571-578
    • /
    • 2009
  • Recently, micropiling techniques are increasingly applied in foundation rehabilitation/underpinning and seismic retrofitting projects where working space provides the limited access for conventional piling methods. Micropiling techniques provide environmental-friendly methods for minimizing disturbance to adjacent structures, ground, and the environment. Its installation is possible in restrictive area and general ground conditions. The cardinal features that the installation procedures cause minimal vibration and noise and require very low ceiling height make the micropiling methods to be commonly used for underpin existing structures. In the design point of view, the current practice obligates the bearing capacity of micropile to be obtained from skin friction of only rock-socketing area, in which it implies the frictional resistance of upper soil layer is ignored in the design process. In this paper, a new micropiling method and its verification studies via field installation are presented. The new method provides a specific way to grout bore-hole to increase frictional resistance between surrounding soil and pile-structure and it allows to consider the skin friction of micropiles for upper soil layer during design process.

  • PDF

Design of a piezovibrocone and calibration chamber

  • Samui, Pijush;Sitharam, T.G.
    • Geomechanics and Engineering
    • /
    • v.2 no.3
    • /
    • pp.177-190
    • /
    • 2010
  • This paper presents the details of indigenous development of the piezovibrocone and calibration chamber. The developed cone has a cylindrical friction sleeve of $150cm^2$ surface area, capped with a $60^{\circ}$ apex angle conical tip of $15cm^2$ cross sectional area. It has a hydraulic shaker, coupled to the cone penetrometer with a linear displacement unit. The hydraulic shaker can produce cyclic load in different types of wave forms (sine, Hover sine, triangular, rectangular and external wave) at a range of frequency 1-10 Hz with maximum amplitude of 10 cm. The piezovibrocone can be driven at the standard rate of 2 cm/sec using a loading unit of 10 ton capacity. The calibration chamber is of size $2m{\times}2m{\times}2m$. The sides of the chamber and the top as well as the bottom portions are rigid. It has a provision to apply confining pressure (to a maximum value of $4kg/cm^2$) through the flexible rubber membrane inlined with the side walls of the calibration chamber. The preliminary static as well as dynamic cone penetration tests have been done sand in the calibration chamber. From the experimental results, an attempt has been made to classify the soil based on friction ratio ($f_R$) and the cone tip resistance ($q_c$).

Evaluation of side resistance for drilled shafts in rock sections

  • Hsiao, Cheng-Chieh;Topacio, Anjerick J.;Chen, Yit-Jin
    • Geomechanics and Engineering
    • /
    • v.21 no.6
    • /
    • pp.503-511
    • /
    • 2020
  • This study evaluated the side resistance of drilled shafts socketed into rock sections. Commonly used analysis methods for side resistance of piles in rocks are examined by utilizing a large number of load test data. The analysis of the unit side resistance of pile foundations embedded into rock sections is based on an empirical coefficient (α) and the uniaxial compressive strength (qu) or its root (${\sqrt{q_u}}$). The Davisson criterion was used to interpret the resistance capacity from the load test results to acquire the computed relationships. The α-${\sqrt{q_u}}$ relationship is proven to be reliable in the prediction of friction resistance. This study further analyzed the relationship by including the effect of rock quality designation (RQD) on the results. Analysis results showed that the analysis model of α-${\sqrt{q_u}}$-RQD provided better prediction and reliability considering the RQD classification. Based on these analyses, the side resistance of drilled shafts socked into rocks is provided with statistical data to support the analysis.

Study on the Undrained Shear Strength Characteristics (반월지역 해성점토의 비배수 전단강도 특성에 관한 연구)

  • 장병욱;박영곤
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.36 no.3
    • /
    • pp.90-99
    • /
    • 1994
  • To investigate the undrained shear strength characteristics of marine soils with high water content, high compressibility and weak bearing capacity, a series of undrained triaxial tests with pore pressure measurements on undisturbed and disturbed Banwol marine clay in normally consolidated and overconsolidated states is carried out. The results and main conclusions of this study are summarized as follows : 1 . When the consolidation pressure is increased, the maximum deviator stress of disturbed and undistubed clay in normally consolidated state is increased. Pore pressure parameters and internal friction angle of undisturbed clay are greater than those of disturbed clay. 2. The relationship between pore pressure and axial strain of undisturbed clay in normally consolidated state can be expressed as a hyperbolic function like stress-strain relation proposed by Kondner. 3. In the pore pressure-axial strain relation of disturbed clay in normally consolidated state, failure ratio R'f is greatly deviated in the range of 0.7~0.9 proposed by Christian and Desai. 4. For overconsolided clay, when overconsolidation ratio (OCR) is increased, normalized maximum deviator stress is increased and maximum pore pressure is decreased gradually. 5. Cohesion of overconsolidated clay is greater than that of nomally consolidated clay and internal friction angle slightly is decreased. 6. Pore pressure parameter at failure (Af) of overconsolidated clay is varied with OCR, Af becomes negative values with increment in OCR

  • PDF

Seismic Performance Evaluation of Vibration Attenuation Wireway-Pulley System Using the FE Analysis (유한요소해석을 통한 진동 감쇠형 와이어웨이시스템의 내진성능 검증)

  • Tran, V. Han;Jin, Su Min;Kim, Sung Chan;Cha, Ji Hyun;Shin, Jiuk;Lee, Kihak
    • Journal of Korean Association for Spatial Structures
    • /
    • v.20 no.4
    • /
    • pp.185-192
    • /
    • 2020
  • A new lighting support structure composing of two-way wires and pulley, a pulley-type wireway system, was developed to improve the seismic performance of a ceiling type lighting equipment. This study verifies the seismic performance of the pulley-type wireway system using a numerical approach. A theoretical model fitted to the physical features of the newly-developed system was proposed, and it was utilized to compute a frictional coefficient between the wire and pulley sections under tension forces. The frictional coefficient was implemented to a finite element model representing the pulley-type wireway system. Using the numerical model, the seismic responses of the pulley-type wireway system were compared to those of the existing lighting support structure, a one-way wire system. The addition of the pulley component resulted in the increasement of energy absorption capacity as well as friction effect and showed in significant reduction in maximum displacement and oscillation after the peak responses. Thus, the newly-developed wireway system can minimize earthquake-induced vibration and damage on electric equipment.

Shear strength response of clay and sand column with different sand grain shapes

  • Zuheir Karabash;Ali Firat Cabalar
    • Geomechanics and Engineering
    • /
    • v.35 no.2
    • /
    • pp.135-147
    • /
    • 2023
  • Sand columns in clayey soil are considered one of the most economical and environmentally-friendly soil-improving techniques. It improves the shear strength parameters, reduces the settlement, and increases the bearing capacity of clayey soils. The aim of this paper is to study the effect of grain shape in sand columns on their performance in improving the mechanical properties of clayey soils. An intensive series of consolidated-drained triaxial tests were performed on clay specimens only and clay specimens with sand columns. The parameters examined during the experimental work were grain shape in sand columns (angular, rounded, sub-rounded) and effective confining pressure (50 kPa, 100 kPa, 200 kPa). The results indicated that there is a significant improvement in the deviatoric stress and stiffness values of specimens with sand columns. Improving deviatoric stress values in the use of angular sand grains was found to be higher than those in the use of sub-rounded and rounded sand grains. A 187%, 159%, and 153% increment in deviatoric stress values were observed for the sand columns with angular, sub-rounded, and rounded grain shapes, respectively. The specimens were observed to be more contractive as the sand column was installed, and as the angularity of grains in the sand column was increased. Sand column installation improves significantly the angle of internal friction, and the effective angle of internal friction increases as the angularity of the sand grains increases.

Characteristics on the Vertical Load Capacity Degradation for Impact driven Open-ended Piles During Simulated Earthquake /sinusoidal Shaking, (타격관입 개단말뚝의 동적진동에 의한 압축지지력 저감특성)

  • 최용규
    • Geotechnical Engineering
    • /
    • v.12 no.6
    • /
    • pp.51-64
    • /
    • 1996
  • After the model open-ended pile attached with strain gages was driven into a pressure chamber, in which the saturated microfine sand was contained, the static compression loading test was performed for that pile. Based on the test results, ultimate pile capacity was determined. Then, either simulated earthquake shaking or sinusoidal shaking was applied to the pile with the sustained certain level OP ultimate pile load. Then, pile capacity degradations characteristics during shaking were studied. Pile capacity degradation during two different shakings were greatly different. During the simulated earthquake shaking, capacity degradation depended upon the magnitude of applied load. When the load applied to the pile top was less than 70% of ultimate pile capacidy, pile capacity degradation rate was less than 8%, and pile with the sustained ultimate pile load had the degradation rate of 90%. Also, most of pile capacity degradation was reduced in outer skin friction and degradation rate was about 80% of ultimate pile capacity reduction. During sinusoidal shaking, pile capacity degradation did not depend on the magnitude of applied load. It depended on the amplitude and the frequency , the larger the amplitude and the fewer the frequency was, the higher the degradation rate was. Reduction pattern of unit soil plugging (once depended on the mode of shaking. Unit soil plugging force by the simulated earthquake shaking was reduced in the bottom 3.0 D, of the toe irrespective of the applied load, while reduction of unit soil plugging force by sinusoidal shaking was occurred in the bottom 1.0-3.0D, of the toe. Also, the soil plugging force was reduced more than that during simulated earthquake shaking and degradation rate of the pile capacity depended on the magnitude of the applied load.

  • PDF

Analysis of Skin Friction Behavior in Prebored and Precast Piles Based on Field Loading Test (재하시험을 통한 매입말뚝의 주면마찰력 거동 분석)

  • Jung, Gyoung-Ja;Kim, Do-Hyun;Lee, Chul-Ju;Jeong, Sang-Seom
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.1
    • /
    • pp.31-38
    • /
    • 2017
  • Skin friction of prebored and precast pile may be one of the most critical factors affecting the bearing capacity and settlement. Special attention was given to the interface behavior of pile-cement milk-surrounding soil when the load is acting on the prebored and precast pile. The cases of single pile were analyzed through a three-dimensional finite element approach and pile loading tests. A series of numerical analyses of the interface of pile-cement milk-soil was conducted with the proposed t-z curve and field measurements. It is shown that the use of cement milk around the pile increases the skin friction and reduces the pile settlement. It is also known that the suggested t-z curve between the cement milk and the soil, enhances the accuracy of the numerical analysis results.