• Title/Summary/Keyword: frequency-response

Search Result 5,571, Processing Time 0.032 seconds

Fatigue Damage Model Comparison with Tri-modal Spectrum under Stationary Gaussian Random Processes (정상 정규분포 확률과정의 삼봉형 스펙트럼에 대한 피로손상 모델 비교)

  • Park, Jun-Bum;Jeong, Se-Min
    • Journal of Ocean Engineering and Technology
    • /
    • v.28 no.3
    • /
    • pp.185-192
    • /
    • 2014
  • The riser systems for floating offshore structures are known to experience tri-modal dynamic responses. These are owing to the combined loadings from the low-frequency response due to riser tension behavior, middle-range frequency response coming from winds and waves, and high-frequency response due to vortex induced-vibration. In this study, fatigue damage models were applied to predict the fatigue damages in a well-separated tri-modal spectrum, and the resultant fatigue damages of each model were compared with the most reasonable fatigue damage calculated by the inverse Fourier transform of the spectrum, rain-flow counting method, and Palmgren-Miner rule as a reference. The results show that the fatigue damage models developed for a wide-band spectrum are applicable to the tri-modal spectrum, and both the Benasciutti-Tovo and JB models could most accurately predict the fatigue damages of the tri-modal spectrum responses.

Time-domain Computation of Broadband Noise due to Turbulence-Cascade Interaction (난류-캐스케이드 상호 작용에 의한 광대역 소음장의 시간영역 계산)

  • Cheong, Cheol-Ung;Jeong, Sung-Su;Cheung, Wan-Sup;Lee, Soo-Gab
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.812-817
    • /
    • 2005
  • The objective of the present work is to develop a time-domain numerical method of broadband noise in a cascade of airfoils. This paper focuses on dipole broadband noise sources, resulting from the interaction of turbulent inflows with the flat-plate airfoil cascade. The turbulence response of a two-dimensional cascade is studied by solving both of the linearised and full nonlinear Euler equations employing accurate higher order spatial differencing, time stepping techniques and non-reflecting inflow/outflow boundary condition. The time-domain result using the linearised Euler equations shows good agreement with the analytical solution using the modified LINSUB code. Through the comparison of the nonlinear time-domain result using the full nonlinear Euler equations with the linear, it is found that the acoustic mode amplitude of the nonlinear response is less than that of the linear response due to the energy cascade from low frequency components to the high frequency ones. Considering the merits of the time-domain methods over the typical time-linearised frequency-domain analysis, the current method is expected to be promising tools for analyzing the effects of the airfoil shapes, non-uniform background flow, linear-nonliear regimes on the broadband noise due to gust-cascade interaction.

  • PDF

A Study on Dynamic Vibration Absorber Using Zener's Model (Zener 모델을 사용한 동흡진기 특성 연구)

  • Oh, Il-Kwon;Lim, Seung-Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.159-163
    • /
    • 2005
  • A dynamic vibration absorber using the Zener's model has been taken into account with respect to frequency response characteristics. The concept of the tuned mass damper with a single degree of freedom has been well applied for many industrial fields, because many researchers have extensively studied various basic characteristics, performance and optimization methods for long time. The Zener's model has an additional spring, which is connected between a damper and a mass, while the tuned mass damper with a single degree of freedom consists of a mass, a spring and a damper connected in parallel. In previous works, the basic performance and characteristics of the Zoner's model as a dynamic vibration absorber have not been investigated. In this study, the frequency response characteristics according to the parameter change of the Zener's model have been described. In order to find the optimum value of several parameters, we use iterative scheme with three dimensional frequency response diagram by MATLAB programming. Present results shows the Zener's model can give more good damping performance than the simple tuned mass damper, and the numerical of optimization method should be developed for the efficient vibration absorbtion.

  • PDF

Determination of Shock Response Spectrum Using FRF of Statistical Energy Analysis Method (통계적 에너지 분석법의 FRF를 이용한 충격 응답 스텍트럼(SRS)의 결정)

  • 구성완;황철규;김인성
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.7
    • /
    • pp.551-560
    • /
    • 2004
  • A method how to determine the shock response spectrum from the FRF of the statistical energy analysis( SEA ) is presented here. The system of 3 different Plates connected by bolt joints is selected simulating missile structural sections Joined together. First, the SEA model was rendered by SEA parameters which were determined from experimental SEA method. Then, the mobility power was input to the SEA model and we can verify the validity of the model in the medium to high frequency range checking the reproduction of output average velocity. And, the shock induced shock response spectrum(SRS) was obtained using SEA FRF and arbitrarily chosen experimental FRF. We have compared the thus obtained SRS with actually measured SRS and they were relatively in good agreement. In this paper, we used the measured SEA FRF and therefore we have got the SRS well agreed with actually measured SHS even in the low frequency range. If the SEA FRF of well verified SEA model is used, the good result will come out in SEA effective frequency range which is more important at SRS.

Damage Evaluation of Porcelain Insulators Using the Frequency Response Function (주파수응답함수(FRF)를 이용한 자기 애자의 손상평가)

  • Choi, In-Hyuk;Son, Ju-Am;Oh, Tae-Keun;Yoon, Young-Geun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.2
    • /
    • pp.122-128
    • /
    • 2019
  • Porcelain insulators have been used mainly for power line fixing and electrical insulation in transmission towers. Porcelain insulators have generally a 30 years desired life, but over 50% exceed their life expectancy. Since the damage to porcelain insulators is usually accompanied by enormous loss of human resource material, their efficient maintenance has emerged as an important issue. In this regard, this study applied a frequency response function (FRF) for integrity assessment of the insulator. The characteristics of the FRF according to damage types were identified and analyzed by the change in natural frequencies, curve shape, attenuation, and Nyquist diagram stability. The results showed significant differences in the FRF according to damage types, which can be used as basic data for the effective integrity assessment of porcelain insulators.

Considerations for the Generation of In-Structure Response Spectra in Seismically Isolated Structures (면진구조물 내 층응답스펙트럼 작성을 위한 고려사항)

  • Lee, Seung Jae;Kim, Jung Han
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.26 no.2
    • /
    • pp.95-103
    • /
    • 2022
  • In order to evaluate the earthquake safety of equipment in structures, it is essential to analyze the In-Structure Response Spectrum (ISRS). The ISRS has a peak value at the frequency corresponding to the structural vibration mode, but the frequency and amplitude at the peak can vary because of many uncertain parameters. There are several seismic design criteria for ISRS peak-broadening for fixed base structures. However, there are no suggested criteria for constructing the design ISRS of seismically isolated structures. The ISRS of isolated structures may change due to the major uncertainty parameter of the isolator, which is the shear stiffness of the isolator and the several uncertainty parameters caused by the nonlinear behavior of isolators. This study evaluated the effects on the ISRS due to the initial stiffness of the bi-linear curve of isolators and the variation of effective stiffness by the input ground motion intensity and intense motion duration. Analyzing a simplified structural model for isolated base structure confirmed that the ISRS at the frequency of structural mode was amplified and shifted. It was found that the uncertainty of the initial stiffness of isolators significantly affects the shape of ISRS. The variation caused by the intensity and duration of input ground motions was also evaluated. These results suggested several considerations for generating ISRS for seismically isolated structures.

Automated structural modal analysis method using long short-term memory network

  • Jaehyung Park;Jongwon Jung;Seunghee Park;Hyungchul Yoon
    • Smart Structures and Systems
    • /
    • v.31 no.1
    • /
    • pp.45-56
    • /
    • 2023
  • Vibration-based structural health monitoring is used to ensure the safety of structures by installing sensors in structures. The peak picking method, one of the applications of vibration-based structural health monitoring, is a method that analyze the dynamic characteristics of a structure using the peaks of the frequency response function. However, the results may vary depending on the person predicting the peak point; further, the method does not predict the exact peak point in the presence of noise. To overcome the limitations of the existing peak picking methods, this study proposes a new method to automate the modal analysis process by utilizing long short-term memory, a type of recurrent neural network. The method proposed in this study uses the time series data of the frequency response function directly as the input of the LSTM network. In addition, the proposed method improved the accuracy by using the phase as well as amplitude information of the frequency response function. Simulation experiments and lab-scale model experiments are performed to verify the performance of the LSTM network developed in this study. The result reported a modal assurance criterion of 0.8107, and it is expected that the dynamic characteristics of a civil structure can be predicted with high accuracy using data without experts.

Stochastic dynamic analysis of porous functionally graded plate: A multivariate adaptive regression splines approach

  • Himanshu P. Raturi;Pradeep K. Karsh;Ravi R. Kumar;Sudip Dey
    • Structural Engineering and Mechanics
    • /
    • v.92 no.3
    • /
    • pp.227-243
    • /
    • 2024
  • This paper introduces a methodology that combines Multivariate Adaptive Regression Splines (MARS) modelling and Monte Carlo Simulation to investigate the natural frequencies of porous functionally graded material (FGM) plates along with the frequency response function (FRF) analysis. The MARS model captures the nonlinear relationship between natural frequencies and different parameters, while the FRF approach provides insights into the plate's frequency response. The proposed methodology is accurate and helpful in studying the impact of porosity, power law index, temperature, and plate thickness on the first three natural frequencies, considering the stochastic variations in material properties caused by manufacturing errors. The porous FGM plate is subjected to a traditional finite element (FE) analysis with random material properties. The power law distribution is used to ascertain the material characteristics of porous functionally graded plates. The effects of critical material characteristics, such as elastic Young's modulus, shear modulus, Poisson's ratio, and mass density, on the natural frequencies of porous FGM are examined. The results show that MARS-based finite element analysis has better computational efficiency than Monte Carlo simulations-based finite element analysis.

Two-dimensional energy transmitting boundary in the time domain

  • Nakamura, Naohiro
    • Earthquakes and Structures
    • /
    • v.3 no.2
    • /
    • pp.97-115
    • /
    • 2012
  • The energy-transmitting boundary, which is used in the well-known finite element method (FEM) program FLUSH, is quite efficient for the earthquake response analysis of buildings considering soil-structure interaction. However, it is applicable only in the frequency domain. The author proposed methods for transforming frequency dependent impedance into the time domain, and studied the time domain transform of the boundary. In this paper, first, the estimation methods for both the halfspace condition under the bottom of the soil model and the pseudo three-dimensional effect were studied with the time domain transmitting boundary. Next, response behavior when using the boundary was studied in detail using a practical soil and building model. The response accuracy was compared with those using viscous boundary, and the boundary that considers the excavation force. Through these studies, the accuracy and efficiency of the proposed time domain transmitting boundary were confirmed.

A Study on the characteristics of vibration induced by Subway operation (지하철 운행에 따른 진동특성에 관한 연구)

  • 배동명;신창혁;이창훈;박상곤
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2000.04b
    • /
    • pp.332-339
    • /
    • 2000
  • In this paper the characteristics of vibration induced by subway trains running on track is discussed. The quantitative prediction of the vibration level and the countermeasure for reduction of necessary, is of importance for the better environment. It was made the constructed Bundang line as first step with the modified Young-Dan type to basis on the Japanese Young-Dan type. In this paper it was measured and analyzed to two region (①Susuh-Bokjung, ②Chorim-Suhyun region) of this, at present operational Bundang line when averaging velocity of train is 60(㎞/h). As the response characteristics of frequency induced by subway operation, it was confirmed that frequency band of neighborhood of 30∼80Hz in generally dominant. Also to assess the quantitative vibration as response level to be measured for each point of two region in subway operation, the vibrational response level was measured at the state to be not subway operation. And the level was approximately 1/5∼1/10 level comparing to subway operation.

  • PDF