Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
/
v.19
no.6
/
pp.59-66
/
2005
This paper presents some features and statistics of electromagnetic pulses radiated from intracloud lightning discharges. The LabVIEW based-measurement system of time-dependent electromagnetic fields was constructed. The frequency bandwidth of the measuring system ranged from 300[Hz] to 1[MHz], and the response sensitivity was 2.78(mV/nT). The resolution and the maximum recording length of the data acquisition system were 12(bits) and 100[ms], respectively. In the electromagnetic pulses radiated from intracloud discharges, a pronounced bipolar pulse appeared with one or more fast pulses superimposed on the initial front part of the bipolar pulse. The mean duration of intracloud discharges was $1.05{\pm}0.32[ms]$, and an average of about 8 outburst pulses appeared for a period.
Journal of the Korean Society for Precision Engineering
/
v.23
no.6
s.183
/
pp.166-173
/
2006
In this study, a probe array has been developed for use in a data storage device that is based on scanning probe microscope (SPM) and MEMS technology. When recording data bits by poling the PZT thin layer and reading them by sensing its piezoresponse, commercial probes of which the tip heights are typically shorter than $3{\mu}m$ raise a problem due to the electrostatic forces occurring between the probe body and the bottom electrode of a medium. In order to reduce this undesirable effect, a poly-silicon probe with a high aspect-ratio tip was fabricated using a molding technique. Poly-silicon probes fabricated by the molding technique have several features. The tip can be protected during the subsequent fabrication processes and have a high aspect ratio. The tip radius can be as small as 15 nm because sharpening oxidation process is allowed. To drive the probe, electrostatic actuation mechanism was employed since the fabrication process and driving/sensing circuit is very simple. The natural frequency and DC sensitivity of a fabricated probe were measured to be 18.75 kHz and 16.7 nm/V, respectively. The step response characteristic was investigated as well. Overshoot behavior in the probe movement was hardly observed because of large squeeze film air damping forces. Therefore, the probe fabricated in this study is considered to be very useful in probe-based data storages since it can stably approach toward the medium and be more robust against external shock.
Proceedings of the Korean Society of Precision Engineering Conference
/
2004.10a
/
pp.756-759
/
2004
We present a piezoelectric actuator using stiffness control and stroke amplification mechanism in order to make large lateral displacement. In this work, we suggest stiffness control approach that generates lateral displacement by increasing the vertical stiffness and reducing the lateral stiffness using additional structure. In addition, an additional structure of a serpentine spring amplifies the lateral displacement like leverage structure. The suggested lateral PZT actuator (bellows actuator) consists of serpentine spring and PZT/electrode layer which is located at the edge of the serpentine spring. The edge of the serpentine spring prevents the vertical motion of PZT layer, while the other edge of the serpentine spring makes stroke amplification like leverage structure. We have determined dimensions of the bellows actuator using ANSYS simulation. Length, width and thickness of PZT layer are 135$\mu$m, 20$\mu$m and 0.4$\mu$m, respectively. Dimensions of the silicon serpentine spring are thickness of 25$\mu$m, length of 300$\mu$m, and width of 5$\mu$m. The bellows actuator has been fabricated by SOI wafer with 25$\mu$m-top silicon and 1$\mu$m-buried oxide layer. The bellows actuator shows the maximum 3.93$\pm$0.2$\mu$m lateral displacement at 16V with 1Hz sinusoidal voltage input. In the frequency response test, the fabricated bellows actuator showed consistent displacement from 1Hz to 1kHz at 10V. From experimental study, we found the bellows actuator using thin film PZT and silicon serpentine spring generated mainly laterally displacement not vertical displacement at 16V, and serpentine spring played role of stroke amplification.
Transactions of the Korean Society for Noise and Vibration Engineering
/
v.18
no.9
/
pp.961-971
/
2008
In the design of a rotor shaft, care should be taken to minimize vibration by taking into account the sources of vibration. In addition, the intensity critical speed, stability, and other related aspects of the system must be considered. especially when it is operated at a critical speed, it is important to address issues related to vibration, as an increase in the whirling response of the rotor shaft can cause damage to the shaft, destruction of the rotor parts, and detrimental abrasions on the bearings. In this thesis, the vibration characteristics of a rotor shaft are investigated through the use of the finite element method. Variations of the diameters and lengths were used to determine the effect of a rotor shaft using Beam No.188(3D linear strain beam) in ANSYS version 11.0 as a universal interpretation program for finite elements. Special care was taken to prevent excessive vibration, which can result from resonance at the initial stage, in the formulation of a dynamic design for a rotor shaft through calculations while changing the diameters and the lengths of the shaft. Moreover, the dynamic characteristics of the critical speed, total mass, D/L(diameter to length) ratio, and natural frequency were verified. Furthermore, the rotor shaft applied by bearing element was calculated and compared by using Combi No. 214(2-D spring-damper bearing).
Currently, vector control is used for speed control of trains because induction motor has high performance is installed in Electric railroad systems. Also, control of the induction motor is possible through various methods by developing inverters and control theory. Presently, rolling stocks which use the induction motor are possible to brake trains by using AC motor. Therefore model of motor block and induction motor is needed to adapt various methods. There is Variable Voltage Variable Frequency (VVVF) as the control method of the induction motor. The torque and speed is controlled in the VVVF. The propulsion system model in the electric railroad has many sub-systems. So, the analysis of performance of the speed control is very complex. In this paper, simulation models are suggested by using Matlab/Simulink in the speed control characteristic. On the basis of the simulation models, the response to disturbance input is analyzed about the load. Also, the current, speed and flux control model are proposed to analyze the speed control characteristic in the train propulsion system.
Background: Intraperitoneal (IP) and intrathecal (IT) administration of $\alpha$-amino-3-hydroxy-5-methyl-4-isoxazole-propionic (AMPA) and kainate (KA) receptor antagonist attenuate hyperalgesia in various models of persistent pain. The purpose of this study was to assess the effects of IP and IT LY293558, a novel AMPA/KA receptor antagonist on mechanical hyperalgesia after incision. Methods: Sprague-Dawley rats were anesthetized with halothane and underwent plantar incision. Two hours later, responses to mechanical stimuli were assessed using the response frequency to a nonpunctate mechanical stimulus and withdrawal threshold to calibrated von Frey filaments. One group of rats received vehicle, 5 or 10 mg/kg of LY293558 IP. In the other group, vehicle, 0.2, 0.5 or 2 nmol of LY293558 was administered IT. Ataxia and motor function were also evaluated. Results: Hyperalgesia was persistent in both the vehicle and 5 mg/kg group. IP administration of 10 mg/kg of LY293558 increased withdrawal threshold at 30 and 60 min after incision; deficits in rotorod performance were observed at 30, 60, 90 and 150 min. IT administration of 0.5 nmol of LY293558 increased the median withdrawal threshold at 30 and 60 min. Motor function was only impaired at 30 min. IT administration of 2 nmol produced hemiparesis. Again, inhibition of pain behaviors outlasted the effects on motor function. Conclusions: These data further suggest AMPA/KA receptors are important for the maintenance of pain behaviors caused by incisions. IT administration of LY293558 was more effective than systemic administration and reducing pain behaviors caused by a surgical incision.
This paper proposes a new improved lumped element equivalent circuit analysis method to analyze withdrawal weighted SAW resonators of irregular electrode configurations, which enables to calculate the frequency response of withdrawal weighted SAW resonators. This method has led to the derivation of Smith equivalent circuit's y-parameters for a single ground electrode and formulated the resonator's admittance by calculating the total current into an IDT assembly. To illustrate the effectiveness of the technique, this method was applied to the design of a simple ladder filter and the change of the filter performance was investigated in relation to the weighting of the series and parallel resonators, respectively. The results shows that the withdrawal weighted resonator ladder filters provide better performance in their bandwidth and transition characteristics than normal ones. This new equivalent circuit analysis method can also serve as a better tool to design and analyze general SAW resonator filters.
The Journal of Korean Institute of Communications and Information Sciences
/
v.23
no.5
/
pp.1349-1359
/
1998
In this paper, presented is the result of a digital implementation of a FM stereo composite signal generator. The chip utilizing DDFS(Direct Digital Frequency Synthesizer architecture is implemented using $1.0\mu\textrm{m}$ CMOS gate-array technology thereby replacing analog componentry. To verify the process of generating composite signals a conventional logic simulation method was used. The processed chip was mounted on an evaluation PCB to test and analyze to signals. According to the measurement result obtained by using a 12-bit DAC, the digital FM composite signal generator produces a 74DB spectrally pure signal over its entire tuning range, which is superior to that of analog counterpart by 14dB in it spectral reponse. And further enhancements of the spectral response is expected to be achieved by using a high resolution digital to analog converter, such as a 16-bit DAC. The resulting signals is superior to the signal of the analoy circuitry typically used, in major characteristics such as S/N ratios, accuracy, tuning stability, and signal seperation.
Journal of the Korean BIBLIA Society for library and Information Science
/
v.28
no.3
/
pp.67-93
/
2017
This study aims to investigate research trends on disaster safety Information based on the language network analysis methods. To accomplish it, we collected 312 Korean thesis and scholarly articles on disaster safety information published between 2008 and 2017 from RISS (Research Information Sharing Service) site. With the collected data, this study performed the statistical analysis based on bibliographic data. Also, this study performed the analysis of frequency and language network on keyword extracted from titles on the collected scholarly articles and thesis. This study found out that researches recently on Bigdata related to disaster safety information have been rapidly increased. Also, the needs of sharing and utilizing disaster safety information have increased. Also the various types of disaster safety information such as spatial data, real-time information, geographic information has been used for the disaster response.
This study was conducted to provide basic policy of home care service centered on early discharging patients from general hospitals. This subjects for this study were 291 discharging patients from university hospital in Chon-ju area. The data were collected during the period from July 1, 1993 through July 16, 1993. The measurement tools were developed based on 9 categorized human responses patterns suggested by NANDA and modified by the research team. The collected data were processed with SPSS/PC + frequency, percentage and mean were used for analysis. From the study, the following summerized conclusions have been drown. A. For home care needs, the mean was $19.0\%$ of possible to total 100 and in a range of $6.2\~39.5\%$ 1. Exchanging Pattern: $17.8\%$ 2. Communication Pattern: $8.6\%$ 3. Relating Pattern : $15.4\%$ 4. Valuing Pattern: $13.4\%$ 5. Choosing Pattern : $6.2\%$ 6. Moving Pattern : $22.9\%$ 7. Perceiving Pattern: $16.5\%$ 8. Knowing Pattern : $30.8\%$ 9. Feeling Pattern : $39.5\%$ B. Response to home care services, 1. $85.6\%$ of subjects didn't hear about home care service. 2. Over $90.0\%$ subjects approved home care service. 3. $83.5\%$of subjects were willing to use home care service. 4. $85.9\%$ of subjects will follow to early discharge order. On the basis of this findings, further studies are required to compare home care needs between patients, their family and community health people groups. And also required to develop to information strategies for home care nursing service.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.