• Title/Summary/Keyword: frequency-response

Search Result 5,570, Processing Time 0.038 seconds

Effect of Exhaust Orifice Noise Depending on Stiffener Flange (STIFFENER FLANGE 축소에 따른 배기 토출음 저감)

  • Shin, Y.S.;Han, D.S.;Yi, G.S.;Park, J.S.;Shin, G.C.;Lee, J.B.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.373-378
    • /
    • 2000
  • Recently, it has been important to develop light, silent and less-vibrational automobile. In this study, in order to investigate the characteristics of the noise caused by the main silencer components-stiffener flange, inlet pipe and exhaust pipe etc., computational flow analysis, vibration and noise experiments were performed about the variable heights of the stiffener flange. Flow structure in the mainsilencer which calculated by CFD solver-IDEAS ESC, and frequency response function results of impact hammer test was proposed and it was found good agreement between former results and the exhaust orifice noise measured.

  • PDF

Development of Shock Testing M/C to Simulate Pyro-technic Device Explosion of Space vehicle (우주비행체 분리장치 작동에 의한 충격현상 모의 시험기 개발)

  • Kim, Hong-Bae;Oh, Jin-Ho;Moon, Sang-Mu;Woo, Sung-Hyun;Lee, Sang-Seol
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.581-586
    • /
    • 2000
  • Explosively activated pyro-technic device is used to release exhausted rocket booster or payloads at prescribed times in the rocket's flight. It creates pyro-shock environment that rocket or payload components must survive. With the shock spectra acquired from flight data, laboratory test should be performed before flight to check whether all of component can sustain the shock environment. The pyro-shock environment simulation was created by the resonance fixture response to a projectile impact. Desired shock spectra is realized by adjusting the natural frequency of resonance plate and the velocity of impact hammer. This paper describes the development process of Pyro-shock testing machine, which is designed and tested by Korean engineers, to verify components of Korean Sounding Rocket(KSR-3) and the other Korean space vehicle. Both analytical and experimental techniques are introduced in this paper.

  • PDF

Development of a 6-DOF Active Vibration Isolation System Using Voice Coil Motor (VCM을 이용한 6자유도 능동형 제진시스템 개발)

  • Gil, Hyeong-Gyeun;Kim, Kwang-San
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.7
    • /
    • pp.637-643
    • /
    • 2010
  • The paper is about the development of 6-DOF active vibration isolation systems using VCM. Firstly, formulate the vertical 3-DOF mathematical model under eccentric load, and compare the model with the case in which the center of mass is located at the centroid. And then, complete the 6-DOF mathematical model by formulating the horizontal 3-DOF mathematical model. Find main parameters by comparing the result of the frequency response test with simulation result on the model. Finally, achieve the performance of vibration isolation by applying loop shaping approach & feedforward controller.

Optimum Approximation of Linear Time - Invariant Systems by Low - Order Models

  • 김상봉
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.19 no.1
    • /
    • pp.71-78
    • /
    • 1983
  • A method is given for obtaining low-order models for a linear time-invariant system of high-order by minimizing a functional of the reduction error between the output response of the original system and the low-order model. The method is based on the Astrom's algorithm for the evaluation of complex integrals and the conjugate gradient method of Fletcher-Reeves. An example illustrating the application of this method is given for approximation of a 4-th order system to be used in the load frequency control of generator systems.

  • PDF

Design of Vibrating Transducer for Implantable Middle Ear Hearing Aid (이식형 중이 청각보조기를 위한 진동 트랜스듀서의 설계)

  • 박형욱
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.4
    • /
    • pp.535-544
    • /
    • 1996
  • In this paper, we analyzed the coil-magnet type vibrating transducer for the implantable middle ear hearing aid which is appropriate for patient's hearing level, and an experimental transducer system is designed For the objective and quantitative analysis of the transducer, a theoretical equivalent model containing coil, magneto and inner ear is developed To perform effective evaluation of the transducer, a transforming ratio Tr is introduced and its range that is suitable for practical implantable middle ear hearing device is foun4 The result of applying physical parameters of ear system to the proposed analytical model shows that frequency response of the coil magrlet type vibrator is predominantly governed by resistive impedance of the coil rather than inertia effect of the magnet and the inner parameters. In addition, we realized an experimental middle ear hearing aid system to show the theoretical validity of designed system and this will provide the basis of the development for actually implantable system.

  • PDF

The Expectation for Material Properties of Microstructure by Application of Dynamic Response Characteristics (동적 응답 특성을 활용한 미세구조의 물성 분포에 대한 예측)

  • Lee, Jeong-Ick;Yeo, Moon-Su
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.3
    • /
    • pp.580-586
    • /
    • 2008
  • This paper addresses the prediction of the material property continuities of a microstructure. Prediction was made by measuring the dynamic responses distribution of the fabricated materials used in the microstructures. When these distributional material properties were used in estimating the mechanical performances of microstructures, the differences between the computer simulation and the experimental result of microstructures could be reduced and their reliability design could be made.

Robust Hybrid Control System (강인 복합제어 시스템)

  • 박규식;정형조;오주원;이인원
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.09a
    • /
    • pp.442-449
    • /
    • 2003
  • This paper presents a robust hybrid control system for seismic response control of a cable-stayed bridge. Because multiple control devices are operating, a hybrid control system could alleviate some of restirctions and limitations that exist when each system is acting alone. A LQG algorithm with on-off control scheme, H$_2$ and H$_{\infty}$ control algorithms with various frequency weighting filters are used to improve the controller robustness of the active control part in the hybrid control system. The numerital simulation results show that control performances of robust hybrid control systems are similar to those of the hybrid control system with LQG algorithm. Furthermore, it is verified that robust hybrid control systems are more robust than the hybrid control system with LQG algorithm and there are no signs of instabilities in the $\pm$5% stiffness matrix perturbed system. Therefore, the proposed hybrid control system have a good robustness for stiffness matrix perturbation without loss of control effectiveness.

  • PDF

Study on Physical Characteristics of Historical and Artificial Ground Accelration (역사지진 및 인공지진의 물리적특성에 관한 연구)

  • 전환석
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1998.04a
    • /
    • pp.52-57
    • /
    • 1998
  • Becaruse of the continual occurrence of minor and moderate earthquake in Korean peninsula, it is generally considered that Korean is nor located in safe region against probable earthquake and more, even though being recognized as a safe contry in earthquake. It is in particular noted that nowadays there has been much concern about undesirable disaster due to unexpected earthquake since the disaster of 1995 Kobe earthquake. Thus, the objective of this research is to develop appropriate design spectrum which could be practicably used in seismic design of important structures taking into consideration of local physical characteristics. Particularly, we have to keep in mind the lessons from 1985 Mexico earthquake which had disregarded deep research on local ground conditions, being a possible magnification phenomena of ground motions in weak soil layer. Various spectra has been described based on the analysis of historical earthquakes, and appropriate design spectrum has been proposed herein.

  • PDF

Experimental Study on Vertical Reduction Effectiveness of Main Control Room of NPP using 3-Dimensional Isolation System (원전 주제어실 삼차원 면진시스템 수직방향 저감효과 시험연구)

  • Ham, Kyung-Won;Lee, Kyung-Jin;Suh, Yong-Pyo
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2006.03a
    • /
    • pp.417-423
    • /
    • 2006
  • The seismic characteristics with 3-Dimensional isolation systems have been studied using a shaking table system. In this study, we made nuclear power plant main control room floor systems and several seismic shaking table tests with and without isolation systems were conducted to evaluate floor isolation effectiveness. Isolation systems have showed large reduction effectiveness in acceleration and response spectra with x and z direction respectively, but horizontal isolation is more effective than vertical one It is required to make isolation systems of which design frequency is below 1Hz when applied to main control room of NPP, but considering much difficulties in making such isolation systems, it is recommended that much consideration should be taken into account when applied to main control room of NPP.

  • PDF

Observer-Based FL-SMC Active Damping for Back-to-Back PWM Converter with LCL Grid Filter

  • Gwon, Jin-Su;Lee, Hansoo;Kim, Sungshin
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.15 no.3
    • /
    • pp.200-207
    • /
    • 2015
  • This paper proposes an active damping control method for a grid-side converter that has an LCL grid filter in the back-to-back converter. To remove the resonant frequency components produced by the LCL filter, it is necessary to measure the grid current. To do this, sensors must be added. However, it is not necessary to add sensors because the grid current is estimated by designing a suboptimal observer. In order to remove the nonlinearity and to gain fast response of control, both feedback linearization and sliding mode control are applied. The proposed method is verified through a simulation.