• Title/Summary/Keyword: frequency-phase method

Search Result 1,647, Processing Time 0.032 seconds

An Improvement Parallel to the Efficiency of Boost Converter for Power Factor Correction (PFC용 부스트 컨버터의 병렬화에 의한 효율 개선)

  • 전내석;장수형;전일영;박영산;안병원;이성근;김윤식
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.120-124
    • /
    • 2001
  • A new technique for improving the efficiency of single-phase high-frequency boost converter is proposed. This converter includes an additional low-frequency boost converter which is connected to the main high-frequency switching device in parallel. The additional converter is controlled at lower frequency. Most of the current flows in the low-frequency switch and so, high-frequency switching loss is greatly reduced accordingly Both switching device are controlled by a simple method; each controller consists of a one-shot multivibrator, a comparator and an AND gate. The converter works cooperatively in high efficiency and acts as if it were a conventional high-frequency boost converter with one switching device. The proposed method is verified by simulation. This paper describes the converter configuration and design, and discusses the steady-state performance concerning the switching loss reduction and efficiency improvement.

  • PDF

Design and Implementation of a Novel Frequency Modulation Circuit using Phase Locked Loop Synthesizer (PLL 주파수 합성기를 이용한 새로운 주파수 변조 회로 설계 및 제작)

  • 양승식;이종환;염경환
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.6
    • /
    • pp.599-607
    • /
    • 2004
  • In this paper, using phase locked loop(PLL) synthesizer, we introduce a novel but simple and low cost frequency modulation(FM) circuit of a flat peak frequency deviation fur modulation signal whose frequency covers from outside to inside of the loop-bandwidth of PLL. The FM circuit was basically designed to compensate an amount of feedback of the loop filter in PLL. The circuit also includes the capability of the adjustment of peak frequency deviation and of blocking the intereference with the loop filter. The designed circuit was successfully implemented and showed the flat frequency deviation as expected in the design. In addition, the novel measurement method of the wideband FM modulation index is suggested verified With the suggest measurement, it can be successfully shown the designed circuit has the expected frequency deviation.

LQ-servo method for non-minimum phase plants (비최소 위상 플랜트에서 LQ-servo 방법)

  • 서병설;장태우
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.3
    • /
    • pp.9-16
    • /
    • 1996
  • LQ-servo is a robustness guaranteed multivariable controller design method based on the LQR structure to improve command following with output feedback. in this paper we introduce a weighting factor on the low frequency part of the state weighting matrix in the performance index in order to increase the low frequency gain of loop transfer function matrix T(s) in the loop shaping design method.

  • PDF

A New Method to Reduce the Size of the ROM in Direct Digital Frequency Synthesizers (직접 디지털 주파수합성기의 ROM 크기를 줄이는 새로운 방식)

  • 강형주;박인철
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.267-270
    • /
    • 1999
  • In this paper, a new method to reduce the size of ROM in the direct digital frequency synthesizer (DDFS) is proposed. In the case that ROM is used for sinusoidal value calculation, reducing the size of ROM is significant. So the power consumption is affected mostly by its bit width. In the proposed method, the ROM bit width is reduced by 1 bit using the phase subtraction and the approximation. The spurious level is better than 80㏈c and the power consumption estimated is 510㎼/MHz.

  • PDF

Modeling and Application Research of Zero Crossing Detection Circuit (Zero Crossing Detection 회로 Modeling 및 응용연구)

  • Jeong, Sungin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.4
    • /
    • pp.143-148
    • /
    • 2020
  • In the case of a system that detects and controls the phase of an alternating voltage, the analog control method compensates the phase offset part by filtering for the detected phase and applies it to the control. However, in the digital control method, precise control cannot be achieved due to an error between the operating frequency of the microprocessor or the microcontroller and the input phase time when controlled using such phase detection. In general, when the method used is a certain time, the accumulated error is compensated and adjusted at random. To solve this problem, a method of detecting a zero point in real time and compensating for the operating frequency of the microprocessor is needed. Therefore, the research to be performed in this paper to reduce these errors and apply them to precise digital control is as follows. 1) Research on how to implement Zero Crossing Detection algorithm through simulation modeling to compensate the zero point to match the operating frequency through detection. 2) A study on the method of detecting zero points in real time through the Zero Crossing Detection design using a microcontroller and compensating for the operating frequency of the microprocessor. 3) A study on the estimation of the rotor position of BLDC motors using the Zero Crossing Detection circuit.

Unified DC Offset Cancellation and I/Q Regeneration with Carrier Phase Recovery in Five-Port Junction based Direct Receivers (Five-port 접합을 이용한 RF 수신기를 위한 동시 DC 오프셋 제거와 I/Q 신호 재생 알고리즘)

  • Park, Hyung-Chul;Lim, Hyung-Sun;Yu, Jong-Won
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.6 s.360
    • /
    • pp.64-70
    • /
    • 2007
  • This paper presents a novel unified DC offset cancellation and I/Q regeneration for five-port junction based direct receivers. It utilizes the symmetry characteristics of the single-frequency continuous-wave (CW) signal, making it possible that the proposed method can be used regardless of carrier phase offset. The proposed method eliminates the additional DC offset cancellation and reduces the I/Q regeneration parameter estimation time. Since the proposed method employs a single-frequency CW signal independent of the modulation scheme, five-port junction based direct receivers can be used for the demodulation of orthogonal frequency-division multiplexing and continuous phase modulation as well as phase shift-keying.

Control of Ultrasonic Motor Using Two-Phase High Frequency Inverter (2상 고주파 인버터에 의한 초음파 모터 제어)

  • Heo, J.Y.;Cho, G.B.;Baek, H.L.;Oh, K.G.;Jeung, H.S.;Yu, K.J.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.462-464
    • /
    • 1994
  • In this paper, noble electrical equivalent circuit ultrasonic motor is applied by model of parallel one from mechanical equation of piezoelectric device and characteristics estimation is done by equivalent converter. Uitrasonic motor is driven by oscillation circuit of two-phase high frequency inverter. Operating frequency of inverter is described by tracking control method of resonance frequency, according to change of load, temperature etc.

  • PDF

A Study on Phase Shift of Driving Signal in order to Output Control of Inverter for High Frequency Induction Heating (고주파 유도가열용 인버터의 출력제어를 위한 구동신호의 위상 천이에 관한 연구)

  • Lee Bong-Seob;Choi Shin-Hyeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.4
    • /
    • pp.580-586
    • /
    • 2006
  • This paper proposes high frequency inverter for induction heating and discusses output control of high frequency inverter. Output control method of inverter is controlled by phase shift of switching devices applied to driving signal and the principle and a characteristic estimates of proposed circuit described on normal parameters. Also output characteristics for circuit design presented to numeric analysis and experimental equipment is made to compare theoretical result with an experimental result and an established characteristic estimate.

  • PDF

A Study on a Current Control Based on Model Prediction for AC Electric Railway Inbalance Compensation Device (교류전력 불평형 보상장치용 모델예측기반 전류제어 연구)

  • Lee, Jeonghyeon;Jo, Jongmin;Shin, Changhoon;Lee, Taehoon;Cha, Hanju
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.6
    • /
    • pp.490-495
    • /
    • 2020
  • The power loss of large-capacity systems using single-phase inverters has attracted considerable attention. In this study, optimal switching sequence model prediction control at a low switching frequency is proposed to reduce the power loss in a high-power inverter system, and a compensation method that can be utilized for model prediction control is developed to reduce errors in accordance with sampling values. When a three-level, single-phase inverter using a switching frequency of 600 Hz and a sampling frequency of 12 kHz is adopted, the power factor is improved from 0.95 to 0.99 through 3 kW active power control. The performance of the controller is also verified.

An Improved Current Control Method for Three-Phase PWM Inverters Using Three-Level Comparator (3레벨 비교기를 이용한 3상인버터의 개선된 히스테리시스 전류제어 기법)

  • Moon, Hyoung-Soo;Han, Woo-Yong;Lee, Chang-Goo;Sin, Dong-Yong;Kim, Mu-Youn
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1035-1037
    • /
    • 2001
  • This paper presents an improved hys- teresis current control method for three-phase PWM power inverters using 3-level comparator. Hysteresis current controller using 3-level comparator has an advantage of constant switching frequency compared with conventional hysteresis current controller. However, this method has disadvantage that the longer sampling period, the larger current error because the switching is performed without considering current error magnitude of each phase. The proposed method improves the control performance by selecting the optimum switching pattern in which the magnitudes of current errors are considered introducing space vector concept. Simulation results using Matlab/Simulink show that the proposed control method reduces current error keeping the merit of previous hysteresis current control method.

  • PDF