• Title/Summary/Keyword: frequency-based method

Search Result 6,110, Processing Time 0.037 seconds

Factors Influencing Sexual Satisfaction in Women who have had a Hysterectomy : A comparative group study (자궁적출술을 받은 부인과 자궁적출술을 받지 않은 부인의 성생활 만족 요인 분석)

  • 장순복
    • Journal of Korean Academy of Nursing
    • /
    • v.20 no.3
    • /
    • pp.357-367
    • /
    • 1990
  • This descriptive study was done to identify factors influencing sexual satisfaction in women who had had a hysterectomy and to compare these with women who had not had a hysterectomy. The purpose was to contribute theoretical understanding on which to base nursing care planning. One group of subjects were 156 women who had had a hysterectomy, between one and 18 months post surgery, living with their spouse, having no complications, and menstruating before surgery. The other group of subjects were 282 healthy women who were living with their husbands and menstruating. The study tool consisted of 108 items including item concerning personal characteristics, characteristics related to the hysterectomy, husband's support, body image, emotions, attitude toward the sexual relationship, knowledge of sexuality, sexual behavior, and sexual satisfaction. Sexual satisfaction was measured by a tool based on Derogatis Sexual Function Inventory. The range of the internal level of the study tool was from. 5208 to .9462. Data collection was done during the period from June 20 to Aug.20, 1989. The same questionnaire was used of data collection for both groups, but a mail survey method was used for the women who had had a hysterectomy, and an interview method was used for the women who had not had a hysterectomy. Data analysis was done using frequency, ratio, mean and S.D. for the characterstics of the subjects and level of sexual satisfaction. t - test or ANOVA was used for the differences between the groups with regard to the general and hysterectomy related characteristics. The relationship between the score for sex life related factors and the level of sexual satisfaction was analyzed using the Pearson Correlation, and the influencing factors on sexual satisfaction were analyzed by stepwise multiple regression. The results of this study were as follows ; 1. Mean age and income level were the only general characteristics for the two groups that were significantly different. The mean age, and income level of the group who had had a hysterectomy were 45years, and 1,150,000 won respectively, and for those who had not had a hysterectomy, 41 years and 999,000 won. 2. There was no statistical difference of the sexual satisfaction score between the two groups. 3. There was differences in the factors influencing sexual satisfaction between the two groups. Factors influencing sexual satisfaction for the group who had had a hysterectomy were husband's support (R=.5793, P=.000) and the women's Knowledge of sexuality(R=.6670, P=.000) (total variance : 33.56). On the other hand, emotional status(R=.4294, P=.000), sexual behavior(R=.4294, P=.000), husband's support(R=.5274, P=.000) and attitude towards sexual relations (R=.5412, P=.000) (total variance : 54.12) were the factors influencing sexual satisfaction in the group who had not had a hysterectomy. Since husband's support and sexuality knowledge were identified as factors influencing sexual satisfaction of women who have had a hysterectomy, it can be concluded that, before a woman who has had a hysterectomy is discharged from hospital, nurses should include strategies in the nursing care plan that will promote husband's support and the women's knowledge of sexuality.

  • PDF

Hardware Design of Rate Control for H.264/AVC Real-Time Video Encoding (실시간 영상 부호화를 위한 H.264/AVC의 비트율 제어 하드웨어 설계)

  • Kim, Changho;Ryoo, Kwangki
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.12
    • /
    • pp.201-208
    • /
    • 2012
  • In this paper, the hardware design of rate control for real-time video encoded is proposed. In the proposed method, a quadratic rate distortion model with high-computational complexity is not used when quantization parameter values are being decided. Instead, for low-computational complexity, average complexity weight values of frames are used to calculate QP. For high speed and low computational prediction, the MAD is predicted based on the coded basic unit, using spacial and temporal correlation in sequences. The rate control is designed with the hardware for fast QP decision. In the proposed method, a quadratic rate distortion model with high-computational complexity is not used when quantization parameter values are being decided. Instead, for low-computational complexity, average complexity weight values of frames are used to calculate QP. In addition, the rate control is designed with the hardware for fast QP decision. The execution cycle and gate count of the proposed architecture were reduced about 65% and 85% respectively compared with those of previous architecture. The proposed RC was implemented using Verilog HDL and synthesized with UMC $0.18{\mu}m$ standard cell library. The synthesis result shows that the gate count of the architecture is about 19.1k with 108MHz clock frequency.

Design of X-band 40 W Pulse-Driven GaN HEMT Power Amplifier Using Load-Pull Measurement with Pre-matched Fixture (사전-정합 로드-풀 측정을 통한 X-대역 40 W급 펄스 구동 GaN HEMT 전력증폭기 설계)

  • Jeong, Hae-Chang;Oh, Hyun-Seok;Yeom, Kyung-Whan;Jin, Hyeong-Seok;Park, Jong-Sul;Jang, Ho-Ki;Kim, Bo-Kyun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.11
    • /
    • pp.1034-1046
    • /
    • 2011
  • In this paper, a design and fabrication of 40 W power amplifier for the X-band using load-pull measurement of GaN HEMT chip are presented. The adopted active device for power amplifier is GaN HEMT chip of TriQuint company, which is recently released. Pre-matched fixtures are designed in test jig, because the impedance range of load-pull tuner is limited at measuring frequency. Essentially required 2-port S-parameters of the fixtures for extraction optimal input and output impedances is obtained by the presented newly method. The method is verified in comparison of the extracted optimal impedances with data sheet. The impedance matching circuit for power amplifier is designed based on EM co-simulation using the optimal impedances. The fabricated power amplifier with 15${\times}$17.8 $mm^2$ shows the efficiency above 35 %, the power gain of 8.7~8.3 dB and the output power of 46.7~46.3 dBm at 9~9.5 GHz with pulsed-driving width of 10 usec and duty of 10 %.

A Study of Torsional Vibrations of Suspended Bridges (현수교(懸垂橋)의 비틀림진동(振動)에 관한 연구(硏究))

  • Min, Chang Shik;Kim, Saeng Bin;Son, Seong Yo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.3 no.3
    • /
    • pp.27-37
    • /
    • 1983
  • A method of dynamic analysis is developed for torsional free vibrations of elliptical-box girder type or stiffening truss system suspension bridge. In this study, the method based on a finite element technique using a digital computer, is illustrated by two numerical examples, the Namhae Bridge which is located in Kyungsang nam-do opened on June, 1973, and the Mt. Chunma Bridge is simple span pedestrian's suspension bridge with lateral bracing system in Mt. Chunma, Kyungki-do, are used. In general, dynamic modes of complex suspension bridges are three-dimensional in form, i.e., coupling between vertical and torsional motions. However, introduced that amplitudes of oscillation are infinitesimal for coincidence with the purpose of it's use, thereupon, the torsional vibration analyses are treated without coupling terms. A sufficient number of natural frequencies and mode shapes for torsional free vibration are presented in this paper. In the case of Mt. Chunma Bridge, the natural frequencies and periods are computed with and without reinforcement, respectively, and compared their discrepancies. The influence of the auxiliary reinforcing cables is prevailing in the first few modes, namely, 1st and 2nd in symmetric and 1st, 2nd and 3rd in antisymmetric vibration, and conspicuous in the symmetric compared with the antisymmetric motion, but in the higher modes, this kind of simple accessory elucidates rether converse effects. In the Namhae Bridge, the results are compared with the Manual's obtained by wind tunnel test. It reveals commendable agreement.

  • PDF

Degradation Evaluation of Mechanical Properties for 12Cr Ferrite Heat Resisting Steel by Reversible Permeability (가역투자율에 의한 12Cr 페라이트 내열강의 역학적 물성의 열화평가)

  • Ryu, Kwon-Sang;Kim, Min-Gi;Nahm, Seung-Hoon;Kim, Chung-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.5
    • /
    • pp.464-470
    • /
    • 2010
  • The integrity of the industrial equipment in use under high temperature and high pressure must be assessed by regularly measuring the degraded mechanical properties during service time. In order to nondestructively monitor the degraded mechanical properties of industrial equipment, a measuring method of the reversible permeability(RP) using surface type probe is presented. The method for measuring the RP is based on that RP is the differential value of hysteresis loop. The RP is exactly the foundation hatmonics induced in a detecting coil measured by lock-in amplifier tuned to a frequency of the alternating perturbing magnetic field. The peak of RP is measured around the coercive force. Steel material used in this work was 12Cr ferritic heat resisting steel. The eleven kinds of samples aged during different times under same temperature ($700^{\circ}C$) were prepared. Peak interval of reversible permeability(PIRP), Vickers hardness, and tensile strength measured for the aged samples decreased abruptly for short aging time (below 500 h), but the change became small at a long aging time. Vickers hardness and tensile strength linearly decreased as RIRP decreased, so the degraded mechanical properties of 12Cr ferritic heat resisting steel could be nondestructively evaluated by measuring RIRP.

Risk Factors of Work-related Low Back Pain in Manufacturing Workers (제조업 근로자들의 작업과 연관된 요통의 위험요인에 관한 연구)

  • Kim, D.H.;Shin, H.R.;Chun, J.H.;Kim, Y.W.;Kim, J.H.;Lee, C.U.
    • Journal of Preventive Medicine and Public Health
    • /
    • v.26 no.1 s.41
    • /
    • pp.20-36
    • /
    • 1993
  • Work-related low back pain is one of the major factors that cause the loss of working power especially in actively working age, therefore controlling the work-related low back pain is one of the major issues in the field of industrial safety and health. This study was performed for detecting the risk factors and proposing the efficient control program of the work-related low back pain. The subjects were male workers employed at the manufacturing industry in Pusan with longer than 6 months' working duration. The data was collected by self-reported questionnaire and interview from May 1 to October 31,1992. The contents of questionnaire were as follows:. the experience of low back pain within the recent one month, general characteristics(age, marital status, education level, religion, regular exercise), physical characteristics(height, weight), employment status(working duration, daily working hours, rest during work, satis(action fur the job), type of work and working environments(posture, forward bending, lifting and movement, satisfaction for table and chair). The result was analyzed for 608 entire respondents by case-control comparative method. The number of cases was 152 with a history of work-related low back pain, so the relative frequency of self-reported work-related low back pain was 25.0%, and the number of controls was 344 without any history of low back pain. As a result, two characteristics of the employment status(working duration, satisfaction fur the job) and all characteristics of type of work and working environments showed a statistical significance between the case and control groups(p<0.01). The Oddb ratios of these variables for Work-related low back pain were calculated. They were 7.88 for the satisfaction fur chair, 7.86 for lifting and movement,3.31 for satisfaction for table, and 2.22 fur bending forward(p<0.01). And for the multivariate logistic regression analysis confirmed that unsatisfaction for table was independent risk factor for Work-related low back pain. In summary, though this study was based upon the self-reported questionnaire and the subjective complaints, the satisfaction for chair, lifting and movement, satisfaction for table, and bending forward concerned with the type of work and working environments were considered as the main factors causing the work-related low back pain, and the work-related low back pain may be preventable by the ergonomic control of these factors.

  • PDF

The Performance Analysis of Diamond Grinding for Existing Concrete Pavement (기존 콘크리트 포장의 성능 향상을 위한 다이아몬드 그라인딩 공법의 초기 공용성 평가)

  • Jung Jong-Duck;Ryu Sung-Woo;Han Seung-Hwan;Cho Yoon-Ho
    • International Journal of Highway Engineering
    • /
    • v.8 no.3 s.29
    • /
    • pp.77-88
    • /
    • 2006
  • The maintenance / repair of concrete pavements has become an issue as a result of increasing of concrete pavements' service year. Asphalt overlay is applied to the concrete pavements after partial repairs on all occasions. This thesis discusses the application standard, evenness, skid resistance, noise, economical efficiency, extension of life span, etc. of diamond grinding, a method of maintenance about concrete pavements. Based on this, it was applied to the field and measured the performance. It was measured the longitudinal evenness of before and after the construction through measurement equipment. and surveyed the skid resistance the each lane classified using the SN standard value. In case of noise, it is selected the kind of vehicle, velocity, then measured the noise between control and constructed site. In addition, it is evaluated the average texture depth. As a result of the analysis, longitudinal evenness is improved about $6{\sim}40%$, skid resistance is improved 66% at first section,37% at second section. Noise is reduced 3.4dB average, and average texture depth is 79% deeper than control section. Therefore, it can be concluded that diamond grinding is suitable as maintenance / repair method of concrete pavements.

  • PDF

A Study on Reliability and Applicability of Oriental Medical Music Therapy Using (음악요법의 한의학적 활용을 위한 신뢰도 및 적용 가능성 연구)

  • Song, Min Sun;Choi, Chan Hun
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.28 no.6
    • /
    • pp.674-682
    • /
    • 2014
  • The purpose of this study was to identify the effect of applying oriental music therapy and reliability of electroencephalogram(EEG) equipment. The study was approved by the critical trial judge committee from ${\bigcirc}{\bigcirc}$(IRB No. 2013-07) university. In order to measure test-retest reliability for 15 subjects, EEG for same participants were measured using same method mentioned above after 2 hours from the first measurement. Same provider implemented to each person at same time. Firstly, EEG was measured for 5 minutes after the subject with attached electrodes sat on chair comfortably for 10 minutes. Then, the subject was given mental stress using the four fundamental arithmetic operations for 5 minutes, and measured EEG for another 5 minutes. After that the subject sat on the chair comfortably listening oriental medicine music therapy for 5 minutes, and EEG was measured for 5 minutes again. There was no side effect regarding music therapy reported. Raw data, which was measured in each step, were converted through FFT(fast fourier transform) and analyzed after divided into certain frequency including ${\alpha}$ wave, ${\beta}$ wave, ${\theta}$ wave, immersion wave, stabilization wave, sef100 wave, and sef95 wave. Data were analyzed using wilcoxon signed rank test, Intraclass correlation coefficient(ICC), repeated measures ANOVA with the SPSS program. In test-retes method, there were significantly differences in ${\alpha}$ wave, ${\beta}$ wave, immersion wave, stability wave, ${\theta}$ wave, sef100 wave, sef95 wave. ICC has shown a high degree of reliability that it was ${\alpha}$ wave .877, ${\beta}$ wave .855, ${\gamma}$ wave .895, immersion wave .897, stability wave .816, ${\theta}$ wave .904, sef100 wave .910, sef95 wave .776. Also, there was a statistically significant difference in ${\alpha}$ wave after applying oriental music therapy. Based on these results, it is considered that average of the channel EEG and application of oriental music therapy would be practiced by increase of sample size using this machine.

Prevention of P-i Interface Contamination Using In-situ Plasma Process in Single-chamber VHF-PECVD Process for a-Si:H Solar Cells

  • Han, Seung-Hee;Jeon, Jun-Hong;Choi, Jin-Young;Park, Won-Woong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.204-205
    • /
    • 2011
  • In thin film silicon solar cells, p-i-n structure is adopted instead of p/n junction structure as in wafer-based Si solar cells. PECVD is a most widely used thin film deposition process for a-Si:H or ${\mu}c$-Si:H solar cells. For best performance of thin film silicon solar cell, the dopant profiles at p/i and i/n interfaces need to be as sharp as possible. The sharpness of dopant profiles can easily achieved when using multi-chamber PECVD equipment, in which each layer is deposited in separate chamber. However, in a single-chamber PECVD system, doped and intrinsic layers are deposited in one plasma chamber, which inevitably impedes sharp dopant profiles at the interfaces due to the contamination from previous deposition process. The cross-contamination between layers is a serious drawback of a single-chamber PECVD system in spite of the advantage of lower initial investment cost for the equipment. In order to resolve the cross-contamination problem in single-chamber PECVD systems, flushing method of the chamber with NH3 gas or water vapor after doped layer deposition process has been used. In this study, a new plasma process to solve the cross-contamination problem in a single-chamber PECVD system was suggested. A single-chamber VHF-PECVD system was used for superstrate type p-i-n a-Si:H solar cell manufacturing on Asahi-type U FTO glass. A 80 MHz and 20 watts of pulsed RF power was applied to the parallel plate RF cathode at the frequency of 10 kHz and 80% duty ratio. A mixture gas of Ar, H2 and SiH4 was used for i-layer deposition and the deposition pressure was 0.4 Torr. For p and n layer deposition, B2H6 and PH3 was used as doping gas, respectively. The deposition temperature was $250^{\circ}C$ and the total p-i-n layer thickness was about $3500{\AA}$. In order to remove the deposited B inside of the vacuum chamber during p-layer deposition, a high pulsed RF power of about 80 W was applied right after p-layer deposition without SiH4 gas, which is followed by i-layer and n-layer deposition. Finally, Ag was deposited as top electrode. The best initial solar cell efficiency of 9.5 % for test cell area of 0.2 $cm^2$ could be achieved by applying the in-situ plasma cleaning method. The dependence on RF power and treatment time was investigated along with the SIMS analysis of the p-i interface for boron profiles.

  • PDF

Statistical Characteristics of the Non-tidal Components Data in Korean Coasts (한반도 연안 비조석 성분자료의 통계적 특성)

  • Cho, Hong-Yeon;Jeong, Shin-Taek;Yoon, Jong-Tae;Kim, Chang-Il
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.18 no.2
    • /
    • pp.112-123
    • /
    • 2006
  • Double-peak normal distribution function was suggested as the probability density function of the non-tidal components (NTC) data in Korean coastal zone. Frequency distribution analysis of the NTC data was carried out using hourly tidal elevation data of the ten tidal gauging stations, i.e., Incheon, Gunsan, Mokpo, Jeju, Yeosu, Masan, Gadeokdo, Busan, Pohang, and Sokcho which were served through the Internet Homepage by the National Ocean Research Institute. NTC data is defined as the difference between the measured tidal elevation data and the astronomical tidal elevation data using 64 tidal constituents information. Based on the RMS error and R2 value comparison analysis, it was found that this suggested function as the probability density function of the NTC data was found to be more appropriate than the normal distribution function. The parameters of the double-peak function were estimated optimally using Levenberg-Marquardt method which was modified from the Newton method. The standard deviation and skewness coefficient were highly correlated with the non-tidal constants of the tidal gauging stations except Mokpo, Jeju and Sokcho stations.