• Title/Summary/Keyword: frequency stabilization

Search Result 274, Processing Time 0.031 seconds

A Study on the Characteristics of High Brightness of LCD-Backlight (LCD-Backlight의 고휘도 특성에 관한 연구)

  • Kim, Soo-Yong;Jee, Suk-Kun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.10
    • /
    • pp.1810-1814
    • /
    • 2006
  • In this paper, the brightmess from inside gas pressure, applied voltages, and operation frequency conditions was measured and the discharge characteristics in FFL(Flat Fluorescent Lamp) also were measured and discussed. The brightness and lifetime after vacuum exhaust ($350^{\circ}C$ and 1 hour) ate remarkably developed. When the gas pressure of lamp-inside is high, the brightness is also increased automatically. But for the stabilization of operation and driving voltage, the highest values of brightness at about 1000[V], 300[Torr] and 64(kHz) are measured and the results are shown as the optimized driving conditions for FFL.

Frequency Stabilization of a Nonlinear Two-Generator Five-Bus Power System using Adaptive Fuzzy Control (퍼지 적응 제어를 이용한 전력게통 주파수 안정화의 비선형 2기 5모선 모의 적용)

  • Moon, Un-Chul
    • Journal of KIISE:Software and Applications
    • /
    • v.27 no.9
    • /
    • pp.952-960
    • /
    • 2000
  • 본 논문에서는 퍼지 자동회귀 이동평균 (Fuzzy Auto-Regressive Moving Average, FARMA)제어기를 전력계통의 비선형 2기 5모선 (Two Machine - Five Bus)모형의 주파수 안정화에 적용한 결과를 제시한다 퍼지 자동회귀 이동 평균 제어기는 기존의 전문가에 의존하였던 퍼지제어 규칙을 실시간으로 형성해 나가는 구조이다. 복잡성, 비선형성 등 전력계통의 일반적인 특징들을 기술하고, 그 특징을 표현할 수 있는 비선형 2기5모선 모형을 제시한다. 제시된 모형을 바탕으로 기존 제어 방식과의 성능 비교를 실시하였고, 이를 통하여 FARMA 제어기의 우수성을 확인하였다.

  • PDF

Effect of Acoustical Excitation and Flame Stabilizer on a Diffusion Flame Characteristics (음향가진과 보염기형상이 확산화염의 특성에 미치는 영향)

  • Jeon, C.H.;Chang, Y.J.
    • Journal of the Korean Society of Combustion
    • /
    • v.3 no.1
    • /
    • pp.1-10
    • /
    • 1998
  • Lots of techniques are adopted for a flame stabilization and a high-load combustion. But the techniques being used were passive control method which have to change combustor shape like pilot flame, flame stabilizer, pressure profile, etc. Active control method which is not necessary to transform its shape is employed. Acoustical excitation is broadly used for its convenience in changing frequency and intensity. Both acoustical excitation and flame stabilizers were adopted to study their relationship. So, we investigated flammability limits. Flame visualization. And mean temperature in the condition of various frequencies, intensities, and flame stabilizers. As a consequence, flammability limit were advanced in acoustically excited flame at some frequencies. Coherent structure was extended to the downstream region through acoustical excitation and a size of vortice was curtailed. Also width of recirculation zone was magnified. In addition, Effects of acoustical excitation was stood out at 25mm flame stabilizer rather than another ones.

  • PDF

On the flutter characteristics of separated two box girders

  • Matsumoto, Masaru;Shijo, Rikuma;Eguchi, Akitoshi;Hikida, Tetsuya;Tamaki, Hitoshi;Mizuno, Keisuke
    • Wind and Structures
    • /
    • v.7 no.4
    • /
    • pp.281-291
    • /
    • 2004
  • The flutter characteristics of long span bridges are discussed from the point of the unsteady pressure distribution on bridge deck surface during heaving/torsional vibration related to the aerodynamic derivatives. In particular, it is explained that the coupling terms, which consist of $A_1^*$ and $H_3^*$, play a substantial role on the coupled flutter, in comparison with the flutter characteristics of various structural sections. Also the effect of the torsional/heaving frequency ratio of bridge structures on the flutter instability is discussed from the point of the coupling effect between heaving and torsional vibrations.

The Optimized Compensator for the Stability of AT Forward MRC (AT 포워드 다중 공진형 컨버터의 안정화를 위한 최적 보상회로)

  • Oh, Yong-Seung;Kim, Chang-Sun;Kim, Hee-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1012-1014
    • /
    • 2001
  • The AT Forward MRC is studied on the stability. The compensator is composed of the error amp with 3 poles and 2 zeros. This is optimized through the experiment. The converter loop gain is measured using HP4194A. We are initiated by the thinking of how to make the stabilization from the experimental results of loop gam curves. The loop gain, low frequency gain and gain margin are more improved through the experimental considerations.

  • PDF

A Design of the Decentralized Adaptive controller on Interconnected Systems (상호 연계된 시스템의 분할 적응 제어계의 설계)

  • Yun, Suk-Youl;Jun, Sang-Young;Yim, Hwa-Yeong
    • Proceedings of the KIEE Conference
    • /
    • 1989.11a
    • /
    • pp.393-396
    • /
    • 1989
  • This paper deals with the design of the adaptive controller using a decentralized control for Large-Scale system formed of an arbitrary interconnection of subsystem with unknown parameters, non linearity and bounded disturbance. In order to reduce the load and frequency deviations, now decentralized adaptive controllers are developed for stabilization and tracking the parameters. In the simulation studies of the decentralized adaptive control of a two-area interconnected power system, the effectiveness of the proposed adaptive is demonstrated.

  • PDF

Low-Order Dynamic Output Feedback Controller Design Against Measurement Noise (측정 잡음을 고려한 저차의 동적출력궤환 제어기 설계)

  • Son, Young-Ik;Jo, Nam-Hoon;Shim, Hyung-Bo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.2
    • /
    • pp.383-388
    • /
    • 2007
  • This paper considers a low-order dynamic output feedback controller design problem. Since the proposed control law inherently has a low-pass filter property, it can alleviate the mal-effects of the sensor noise without additional filter designs. Frequency domain analysis shows the characteristics of the proposed control law against measurement noise. The effectiveness of the proposed control law is illustrated by numerical simulations with a rotary inverted pendulum and a convey-crane. Using only one integrator the proposed control law has the advantage to the stabilization problem with sensor noise as well as it can successfully replace the measurements of derivative terms in a state feedback control law.

A Study on the Stabilization of Induction Heating System for Using High-Frequency Series Resonant Inverter (고주파 직렬 공진형 인버터를 이용한 유도가열 시스템의 안정화에 관한 연구)

  • Park, Sang-Min;Woo, Hyoung-Gyun;Shin, Dae-Chul
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.506-507
    • /
    • 2010
  • 유도가열용 공진형 인버터는 부하에 전류가 흐르면 전자유도 작용에 의해서 와전류가 발생된다. 이 와전류에 의해 발열체가 가열되는 시스템이다. 그러나 유도가열용 인버터에 사용되는 IGBT나 MOSFET와 같은 스위칭 소자들은 스위칭 시 순간 과전류의 발생이나 외부의 이상과전류로 인해서 소자가 파괴 되거나 오작동을 일으키게 되어 전기기기의 손상을 가져올 수 있다. 이를 방지하기 위하여 공급 전원에 비교기를 사용하여 전류의 변화를 감지하고 전류를 차단하는 고주파 직렬 공진형 인버터를 이용한 유도가열 시스템의 안정화에 관한 연구를 하고자 한다.

  • PDF

Extended Integral based Governor Control for Power System Stabilization (확장된 PI 제어를 이용한 전력계통 안정도 향상에 관한 연구)

  • Kim, Hyun-Sung;Min, Kyoung-Il;Ryu, Heon-Su;Moon, Young-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.268-270
    • /
    • 2002
  • 본 논문에서는 댐핑이 고려된 전력계통에서 동요시 안정도를 향상시킬 수 있는 확장된 PI제어를 이용한 조속기 제어기를 제안하였다. 전력계통에서의 동요는 대부분 고장기간 동안에 발전기에 저장된 과잉운동에너지에 의해 발생한다. 계통이 안정하도록 하기 위해서 과잉에너지를 효과적으로 다루려면 보통 직접법을 사용된다. 과잉에너지를 제어하기 위한 직접적인 방법으로는 LFC(Load Frequency Control)의 궤한이 활용된다. 확장된 PI제어 방식이 적용된 제어기는 지역내에서와 지역사이에서의 동요를 감쇄시키기 위한 조속기에 적용될 수 있다 또한 제안된 제어기는 조속기에 스팀밸브 제한 조건이나 발전율 제약조건(Generation Rate Constraint; GRC)과 같은 특이점이 존재할 때에도 우수한 성능을 보여주었다. 시뮬레이션은 두지역의 다기계통에서 부하를 변화시켜가며 실시하였다. 시뮬레이션 결과는 제안된 PI 제어기를 기존의 PI 제어기와 비교하여 매우 향상된 성능을 보여주었다.

  • PDF

Constriction of a hot-wire anemometer (熱線流速計의 試作硏究)

  • 이규한
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.5
    • /
    • pp.779-786
    • /
    • 1986
  • Hot-wire anemometer with constant temperature hot-wire anemometer bridge, linearizer, D.C. stabilization electric power source and square-wave generater has been constructed for trial and the test has been carried out. As a result the test showed the overall frequency response of 6KHz over the change of air flow and the noise of approximately 1cm/s in an air flow of 10m/s. The accuracy of the lienarizer stands comparison with the existing anemometer and turned out to be relatively good operational characteristics.