• Title/Summary/Keyword: frequency shifts

Search Result 184, Processing Time 0.025 seconds

Rapid Detection of Salmonella spp. by Antibody-Immobilized Piezoelectric Crystal Biosensor (고정화법을 달리하여 제조한 압전류적 항체 센서에 의한 Salmonella spp.의 신속 검출)

  • 박인선;김우연;김남수
    • Journal of Food Hygiene and Safety
    • /
    • v.13 no.3
    • /
    • pp.206-212
    • /
    • 1998
  • An improved antibody-coated sensor system based on quartz crystal microbalance was developed for the detection of Salmonella spp. An antibody against Salmonella common structural antigen was immobilized onto one gold electrode of the piezoelectric quartz crystal surface by various immobilization procedures. The best results in sensitivity and stability were obtained with the thin layers of protein A and 3,3'-dithiopropionimidate.2HCI(DTBP), a homobifunctional thiol-cleavable crosslinker. After the addition of a S. typhimurium suspension into a reaction cell with 0.1 M sodium phosphate buffer, pH 7.2, the resonant frequency owing to S. typhimurium adsorption decreased conspicuously. The antibody-immobilized crystals prepared by the gold-protein A complex formation and DTBP thiolation showed the frequency shifts of 80 and 283 Hz, respectively. The time required for maximum frequency shift was about 30~60 min. The antibody-coated crystal could be reused for 6~8 consecutive assays.

  • PDF

Reproducibility of physiological patterns in disgust visual stimulation design

  • Lee, Kyung-Hwa;E. Sokhadze;Jang, Eun-Hye;Yang, Gyung-Hye;Sohn, Jin-Hun
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2000.11a
    • /
    • pp.73-80
    • /
    • 2000
  • The paper is addressed to the topic of physiological response-specificity in disgust induced by visual stimulation. The purpose of this study was to evaluate reproducibility of physiological reactivity pattern during disgust elicited by the International Affective Pictures System (IAPS) in 2 experiments. Twenty-nine subjects participated in the first experiment with 3 visual stimulation sessions with disgust-eliciting slides (3 slides in each 1 min long session). In the second experiment disgust-eliciting slides from the IAPS were presented to 42 subjects in 2 sessions (one slide for 1 min). Spectral power of frontal EEG, skin conductance (SCL, SCR and NS.SCR), heart rate(HR), heart period variability(HPV) and respiration rate were recorded. Visual stimulation evoked 1:.n deceleration, higher power of high frequency component of HPV, increased SCL and NS.SCR frequency, frontal slow alpha blocking and moderate increase in fast beta power in most of the sessions in both experiments. However in the second experiment the EEG pattern associated with disgust showed inconsistent shifts in fast alpha and slow beta bands, but was marked by higher power of theta activity. Our data in both experiments emphasizes presence of disgust-specific profiles of autonomic and at the less extent EEG responses in visual stimulation context. Discussed are potential behavioral mechanisms leading to observed physiological manifestations in disgust elicited by visual stimulation. The results support the consideration that disgust is an withdrawal type negative valence emotion associated with relatively low autonomic arousal (low HR, low amplitude SCRs with relatively high NS.SCR frequency) and moderate EEG activation signs. Obtained data showed more consistent reproducibility of disgust-specific autonomic rather than EEG response patterns during visual stimulation design.

  • PDF

Simultaneous Measurement of Strain and Damage Signal in Composite Structures Using a Fiber Bragg Grating Sensor (광섬유 브래그 격자 센서를 이용한 복합재 구조물의 변형률 및 파손신호 동시 측정)

  • Koh, Jong-In;Bang, Hyung-Joon;Kim, Chun-Gon;Hong, Chang-Sun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.7
    • /
    • pp.43-50
    • /
    • 2004
  • For the simultaneous measurement of strain and damage signal a fiber Bragg grating sensor system with a dual demodulator was proposed. The dual demodulator is composed of a demodulator using a tunable Fabry-Perot filter measuring the low-frequency signal with large magnitude such as strain and the other using a passive Mach-Zehnder interferometer detecting the high-frequency signal with small amplitude such as impact or damage signal. Using the proposed fiber Bragg grating sensor system, both the strain and damage signals of a cross-ply laminated composite beam under tensile loading were simultaneously measured. The strain and damage signals detected by single fiber Bragg grating sensor showed that sudden strain shifts were accompanied with vibration at a maximum frequency of several hundreds of kilohertz at the instant of matrix crack propagation in the 90 degree layer in composite beam.

Simultaneous Measurement of Strain and Damage Signal of Composite Structures Using a Fiber Bragg Grating Sensor (광섬유 브래그 격자 센서를 이용한 복합재 구조물의 변형률 및 파손신호 동시 측정)

  • Koh Jong-In;Bang Hyung-Joon;Kim Chun-Gon;Hong Chang-Sun
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2004.04a
    • /
    • pp.95-102
    • /
    • 2004
  • For the simultaneous measurement of strain and damage signal, a fiber Bragg grating sensor system with a dual demodulator was proposed. One demodulator using a tunable Fabry-Perot filter can measure low-frequency signal such as strain and the other demodulator using a passive Mach-Zehnder interferometer can detect high-frequency signal such as damage signal or impact signal. Using a proposed fiber Bragg grating sensor system, both the strain and damage signal of a cross-ply laminated composite beam under tensile loading were simultaneously measured. Analysis of the strain and damage signals detected by single fiber Bragg grating sensor showed that sudden strain shifts were induced due to transverse crack propagation in the 90 degree layer of composite beam and vibration with a maximum frequency of several hundreds of kilohertz was generated.

  • PDF

Non-Invasive Blood Glucose Sensor By Sub-Microwave Oscillator (준 마이크로파 발진기를 이용한 비 침습 혈당 센서)

  • Yun, Gi-Ho
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.9
    • /
    • pp.9-16
    • /
    • 2017
  • In this paper, sub-microwave oscillator sensor is proposed to non-invasively monitor the glucose concentration level of the human biological tissue by oscillation frequency variation. Inductive slot in the ground plane of the microstrip line is combined with the biological tissue, to realize the resonator as a part of the oscillator sensor. The phantom box mimicking the human tissue is introduced for simulation of the resonator which resonance frequency correspondingly shifts up on three step glucose concentration levels(0, 400, 800 mg/dL). Oscillator sensor circuit is fabricated as a prototype. Pig tissues instead of human is used. Oscillation frequency shift of about 14 MHz per glucose level of 400 mg/dL has been successfully measured around 1,100 MHz. This proves that the proposed sensor is applicable to a blood glucose sensor.

Direct Numerical Simulation of Low Frequency Instability in a Hybrid Rocket with Equivalence Ratio Effects (하이브리드 로켓의 저주파불안정성에 미치는 당량비 영향 직접수치해석)

  • Choi, Hyosang;Lee, Changjin;Kang, Sang Hun
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.23 no.2
    • /
    • pp.60-67
    • /
    • 2019
  • To understand the low frequency instability(LFI) characteristics in hybrid rockets combustion, effects of equivalence ratio variations on the phase shift between pressure and heat release oscillations were investigated by using the direct numerical simulation. The change in the equivalence ratio of the main chamber was simulated by the temperature and composition variation of the combustion gas introduced into the post-combustion chamber. In the results, additional combustion appeared along with vortex generation at the backward step, and combustion pressure and heat release oscillations were observed as the vortex moved. In addition, the results confirmed that the phase difference between the pressure and heat release oscillation shifts because of the changes in the propagation velocity of pressure wave as the temperature of combustion gas changes.

Relationship between Infrared Peak Maximum Position and Molecular Interactions

  • Ryu, Soo-Ryeon;Noda, Isao;Jung, Young-Mee
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.11
    • /
    • pp.4011-4015
    • /
    • 2011
  • We explored the interpretation of the well-accepted correlation between the apparent peak maximum position shift and extent of molecular interactions, like hydrogen bonding and dipole-dipole interactions, based on the overlapped multiple band model. The simulation of two overlapped Lorentzian bands was carried out to interpret how the maximum position of a composite peak relates to the relative contributions of two species representing the different levels of molecular interactions, i.e., free (or very weekly bound) vs. strongly bound. To demonstrate the validity of our interpretation of the origin of the peak position shift, the temperaturedependent IR spectra of ethylene glycol were also analyzed. It was found through the analysis of simulated and experimental spectra that the apparent peak shift in certain case can be safely interpreted as the measure of the strength of hydrogen bonding. The result of this study gives a new insight to interpret molecular interactions probed by vibrational spectroscopy.

Synthesis, Crystal Structure, Spectra Characterization and DFT Studies on a Di-Cycle Pyrazoline Derivative

  • Song, Jie;Zhao, Pu Su;Zhang, Wei Guang
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.7
    • /
    • pp.1875-1880
    • /
    • 2010
  • A dicycle pyrazoline derivative, 1-phenyl-5-(p-fluorophenyl)-3,4-($\alpha$-p-fluoro-tolylenecyclohexano) pyrazoline, was synthesized and characterized by elemental analysis, IR, UV-vis, fluorescence spectra and X-ray single crystal diffraction. Density function theory (DFT) calculations were performed by using B3LYP method with 6-$311G^{**}$ basis set. The optimized geometry can well simulate the molecular structure. Vibrational frequencies were predicted, assigned and compared with the experimental values, which suggest that B3LYP/6-$311G^{**}$ method can well predict the IR spectra. Both the experimental electronic absorption spectra and the predicted ones by B3LYP/6-$311G^{**}$ method reveal three electron-transition bands, with the theoretical ones having some red shifts compared with the experimental data. Natural bond orbital analyses indicate that the absorption bands are mainly derived from the contribution of n $\rightarrow\pi^*$ and $\pi\rightarrow\pi^*$ transitions. Fluorescence spectra determination shows that the title compound can emit blue-light at about 478 nm. On the basis of vibrational analysis, the thermodynamic properties of title compound at different temperature have been calculated, revealing the correlations between $C^0_{p,m}$, $S^0_m$, $H^0_m$ and temperature.

Effects of Sheet Thickness on the Electromagnetic Wave Absorbing Characterization of Li0.375Ni0.375Zn0.25-Ferrite Composite as a Radiation Absorbent Material

  • Kim, Dong-Young;Yoon, Young-Ho;Jo, Kwan-Jun;Jung, Gil-Bong;An, Chong-Chul
    • Journal of electromagnetic engineering and science
    • /
    • v.16 no.3
    • /
    • pp.150-158
    • /
    • 2016
  • This paper reports on a study of LiNiZn-ferrite composite as a radiation absorbent material (RAM). The electromagnetic (EM) wave absorbers are composed of an EM wave absorbing material and a polymeric binder. The surface morphology, chemical composition, weight percent of the ferrite composite of the toroid sample, magnetic properties, and return loss are investigated using field emission scanning electron microscopy (FE-SEM), energy dispersive X-ray spectroscopy (EDX), X-ray photoelectron spectroscopy (XPS), thermogravimetric analysis (TGA), vibrating sample magnetometer (VSM), and network analyzer. For preparing the absorbing sheet, chlorinated polyethylene (CPE) is used as a polymeric binder. The EM wave absorption properties of the prepared samples were studied at 4 - 8 GHz. We can confirm the effects of the thickness of the samples for absorption properties. An absorption bandwidth of more than a 10-dB return loss shifts toward a lower frequency range along with an increase in the thickness of the absorber.

Elimination of environmental temperature effect from the variation of stay cable force based on simple temperature measurements

  • Chen, Chien-Chou;Wu, Wen-Hwa;Liu, Chun-Yan;Lai, Gwolong
    • Smart Structures and Systems
    • /
    • v.19 no.2
    • /
    • pp.137-149
    • /
    • 2017
  • Under the interference of the temperature effect, the alternation of cable force due to damages of a cable-stayed bridge could be difficult to distinguish. Considering the convenience and applicability in engineering practice, simple air or cable temperature measurements are adopted in the current study for the exclusion of temperature effect from the variation of cable force. Using the data collected from Ai-Lan Bridge located in central Taiwan, this work applies the ensemble empirical mode decomposition to process the time histories of cable force, air temperature, and cable temperature. It is evidently observed that the cable force and both types of temperature can all be categorized as the daily variation, long-term variation, and high-frequency noise in the order of decreasing weight. Moreover, the correlation analysis conducted for the decomposed variations of all these three quantities undoubtedly indicates that the daily and long-term variations with different time shifts have to be distinguished for accurately evaluating the temperature effect on the variation of cable force. Finally, consistent results in reducing the range of cable force variation after the elimination of temperature effect confirm the validity and stability of the developed method.