• 제목/요약/키워드: frequency rate

검색결과 6,604건 처리시간 0.031초

샘플링율이 맥박변이도 시간 및 주파수 영역 분석에 미치는 영향 (An Effect of Sampling Rate to the Time and Frequency Domain Analysis of Pulse Rate Variability)

  • 양윤라;신항식
    • 전기학회논문지
    • /
    • 제65권7호
    • /
    • pp.1247-1251
    • /
    • 2016
  • This study aims to investigate the effect of sampling frequency to the time domain and frequency domain analysis of pulse rate variability (PRV). Typical time domain variables - AVNN, SDNN, SDSD, RMSSD, NN50 count and pNN50 - and frequency domain variables - VLF, LF, HF, LF/HF, Total Power, nLF and nHF - were derived from 7 down-sampled (250 Hz, 100 Hz, 50 Hz, 25 Hz, 20 Hz, 15 Hz, 10 Hz) PRVs and compared with the result of heart rate variability of 10 kHz-sampled electrocardiogram. Result showed that every variable of time domain analysis of PRV was significant at 25 Hz or higher sampling frequency. Also, in frequency domain analysis, every variable of PRV was significant at 15 Hz or higher sampling frequency.

사료 공급 횟수 및 만복 공급율이 비단잉어 홍백치어의 성장 및 체조성에 미치는 영향 (Effects of Feeding Frequency and Satiation Rate on the Growth and Body Composition of Red- and White-colored Carp, Cyprinus carpio var. koi)

  • 김이오;이상민
    • 한국수산과학회지
    • /
    • 제43권4호
    • /
    • pp.320-324
    • /
    • 2010
  • We investigated the proper feeding frequency and satiation rate for the growth of red- and white-colored carp fingerlings in a feeding experiment. Triplicate groups of fish averaging 6.3 g were fed diets at four feeding frequencies (1, 2, 3, or 4 meals a day) and two satiation rates (satiation and 80% satiation) for 6 weeks. The survival of the fish was not affected by either the feeding frequency or the satiation rate. The weight gain, feed efficiency, and protein efficiency ratio of fish were affected by the feeding frequency and satiation rate, and increased significantly with both. The feed efficiency and protein efficiency ratio with satiation feeding of fish fed four meals a day did not differ from those of fish fed three meals a day. The daily feed intake was affected by the feeding frequency and satiation rate. The moisture, crude lipid, and ash contents of whole body were affected by the feeding frequency. Moisture and crude lipid contents were affected by feeding satiation. Based on these results, we conclude that the proper feeding frequency and satiation rate for the optimum growth of red- and white-colored carp fingerlings is four meals a day with satiation feeding.

우리말 어휘빈도 정보와 분절음 탈락의 관련성에 대한 연구 (Correlation between the frequency of word and the deletion of segment)

  • 차재은
    • 대한음성학회지:말소리
    • /
    • 제47호
    • /
    • pp.1-13
    • /
    • 2003
  • The purpose of this paper is to research the correlation between frequency and the deletion of /w, (equation omitted)/ in Korean. For this purpose, I select 11 words from the frequency data, then, analyze the speech of 20 speakers of standard Korean. As a result, I can find that there is correlation between the frequency and the deletion rate of segment. The rate of deletion is higher in high frequency words, while the rate of realization is higher in low frequency words. Although there is correlation between the frequency and the deletion rate of segment, the feature of segment, prosodic environments are more important in segment deletion.

  • PDF

발화 속도와 말차례 교체 빈도에 따른 운율 단위 변화에 관한 연구 (A study on the change of prosodic units by speech rate and frequency of turn-taking)

  • 원유권
    • 말소리와 음성과학
    • /
    • 제14권2호
    • /
    • pp.29-38
    • /
    • 2022
  • 이 연구는 국립국어원 일상 대화 음성 코퍼스(2020)에서 나타나는 발화를 분석하여 발화 속도 및 말차례 교체 빈도가 운율 단위 변화에 어떤 영향을 끼치는지 밝히는 것을 목적으로 하였다. 분석 결과, 발화 속도가 증가할수록 억양구, 어절 빈도, 발화 길이가 증가하는 양의 상관관계를 보였으나 상관관계가 낮았고, 회귀모형의 적합도는 3%-11%로 설명력이 약했다. 말차례 교체 빈도에 따른 평균 발화 속도는 유의미한 차이가 있었고, 말차례 교체 빈도가 증가할수록 발화 속도는 감소하였다. 또한 말차례 교체 빈도가 증가할수록 억양구 및 어절 빈도와 발화 길이는 감소하였으며 높은 음의 상관관계가 있는 것으로 나타났다. 회귀 모형의 적합도는 27%-32%로 계산되었다. 말차례 교체 빈도가 발화 속도와 운율 단위를 변화시키는 요인으로 작용했을 수 있다. 이는 대화체에서 나타나는 비유창성, 말차례 교체 특성, 화자 간 활발한 상호작용 등이 영향을 미쳤을 것이라 추측된다.

응급구조사 직무기술서 작성에 따른 일의 요소별 빈도 및 중요도 조사 연구 (Investigating Research on the Degree of Frequency and Importance of Tasks for Framing the EMTs Occupational Description)

  • 김태민;김효식;유순규
    • 한국응급구조학회지
    • /
    • 제5권1호
    • /
    • pp.199-212
    • /
    • 2001
  • This research, aiming at analyzing the Emergency Medical Technicians' duties prior to establishing a baseline for question development in the national exams to qualify for the EMTs, investigated the importance and frequency per unit specified in the description with the EMTs to be subjects working on the task spot by means of questionnaires. The EMT duties were classified into 9 items like 1) the notification and response, 2) the scene size-up, 3) the patient assessment, 4) the emergency care, 5) the patient transport, 6) the duties at hospital clinics, 7) the operational management, 8) the receiving and responding to a call, 9) the self-development, and put the functional tasks into 52 items, describing the task elements into 177 items, and then questioned 112 EMTs working on the spot from July 21 through August 30, 2000, which showed the following results. 1) The distribution of subjects' career showed the highest rate with 33.9% for those who careered "less than a year", only 13.4% for those with more than 4 years and the highest rate with 43.8% for those who aged at 20-25. And 70.5% of all those who were questioned was the junior college graduates, 58.9% for those working at fire station and 29.5% working at hospital clinics. 2) Looking at the distribution of frequency and importance for each task element, questioning 'the patients main symptoms', 'accidental type', 'place of the patients identification' showed the highest rate in both frequency and importance in the field of "notification and response". 3) In the "scene size-up", identifying the patients showed the highest rate of frequency and importance, compared to other field of tasks, among which "identifying the patients' state" showed the highest rate of frequency (2.66) and importance (2.81). 4) In the "patient assessment", "identifying the patients" showed the high rate of frequency and importance in most elements of task, especially the importance showed the highest rate with 2.83 for the task of airway management and the cervical immobilization during "the primary assessment", and the frequency showed the highest rate for questioning the past case of the task of grasping the patients' history. 5) In the "emergency care", "the management of the heart attacked patients" and "the advanced cardiac life support" showed a high rate in the importance, whereas the frequency showed a very low rate. The high rate of frequency during the emergent task was the management of "musculoskeletal system injury patients" and of "the gastro-intestinal and urinary genital system injury patient support." In care of the patients with heart attack, the management of the airway showed the highest rate with 2.95, whereas the management of alcoholic abused patients and of dying patients, showed comparatively lower rate of assessment in the importance. The frequency of tasks showed the highest rate with 2.69 in the control of bleeding and the lowest with 0.47 in the management of abnormal delivery of child. 6) As to the patient transport, "the emergency transport" showed the highest rate with 2.74 and the unemergent transport with 2.55 in the importance, and the task importance at hospital showed the highest rate with 2.89 in managing the cardio-pulmonary resuscitation and with 2.60 in identifying the patient state. 7) Of all the tasks related with "operational task", the high importance was to "educate for the management of the first responder", but the frequency of tasks mostly showed a low rate and "receiving and responding to a call" showed relatively a high rate of importance and frequency. And related with "the self-development", "the health care management" and "the stress control" on working spot showed a high rate, but the frequency mostly showed a low rate.

  • PDF

Inertial Control of a DFIG-based Wind Power Plant using the Maximum Rate of Change of Frequency and the Frequency Deviation

  • Lee, Hyewon;Kim, Jinho;Hur, Don;Kang, Yong Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권2호
    • /
    • pp.496-503
    • /
    • 2015
  • In order to let a wind generator (WG) support the frequency control of a power system, a conventional inertial control algorithm using the rate of change of frequency (ROCOF) and frequency deviation loops was suggested. The ROCOF loop is prevailing at the initial stage of the disturbance, but the contribution becomes smaller as time goes on. Moreover, its contribution becomes negative after the frequency rebound. This paper proposes an inertial control algorithm of a wind power plant (WPP) using the maximum ROCOF and frequency deviation loops. The proposed algorithm replaces the ROCOF loop in the conventional inertial control algorithm with the maximum ROCOF loop to retain the maximum value of the ROCOF and eliminate the negative effect after the frequency rebound. The algorithm releases more kinetic energy both before and after the frequency rebound and increases the frequency nadir more than the conventional ROCOF and frequency loops. The performance of the algorithm was investigated under various wind conditions in a model system, which includes a doubly-fed induction generator-based WPP using an EMTP-RV simulator. The results indicate that the algorithm can improve the frequency drop for a disturbance by releasing more kinetic energy.

Heart Rate Variability and Metabolic Syndrome in Hospitalized Patients with Schizophrenia

  • Lee, Kyung-Hee;Park, Jeong-Eon;Choi, Jeong-Im;Park, Chang-Gi
    • 대한간호학회지
    • /
    • 제41권6호
    • /
    • pp.788-794
    • /
    • 2011
  • Purpose: Reduced heart rate variability significantly increases cardiovascular mortality. Metabolic syndrome increases the cardiac autonomic dysfunction. Recently, increasing cardiovascular mortality has been reported in patients with schizophrenia. This study was done to compare heart rate variability between adults with and without schizophrenia and to compare the relationship of heart rate variability to metabolic syndrome in hospitalized patients with schizophrenia. Methods: This was a descriptive and correlational study in which 719 adults without schizophrenia and 308 adults with schizophrenia took part between May and June 2008. We measured the following: five-minute heart rate variability; high-frequency, low-frequency, the ratio of low-frequency to high-frequency, and the Standard Deviation of all the normal RR intervals. Data was also collected on metabolic syndrome, abdominal obesity, triglycerides, HDL cholesterol, blood pressure and fasting glucose. Results: The Standard Deviation of all the normal RR intervals values of heart rate variability indices were $1.53{\pm}0.18$. The low-frequency and high-frequency values of heart rate variability indices were significantly higher in hospitalized patients with schizophrenia ($3.89{\pm}1.36$; $3.80{\pm}1.20$) than those in the healthy participants ($2.20{\pm}0.46$; $2.10{\pm}0.46$). There were no significant differences between the schizophrenic patients with and without metabolic syndrome. Conclusion: The results of this study indicate that schizophrenia patients have significantly lower cardiac autonomic control, but they have significantly higher low-frequency and high-frequency values than those of healthy adults. Use of antipsychotic drug may affect the autonomic nervous system in schizophrenic patients. Metabolic syndrome was not associated with cardiac autonomic control in schizophrenia patients.

The Effect of Electroacupuncture on the Heart Rate Variability of Stroke Patients under Mental Arithmetic Stress

  • Oh, Jae-Gun;Kwon, So-Yeon;Yun, Henja;Sung, Kang-Keyng
    • 대한한의학회지
    • /
    • 제33권4호
    • /
    • pp.50-59
    • /
    • 2012
  • Objectives: This study aimed to compare the effects of high frequency electroacupuncture, low frequency electroacupuncture and manual acupuncture on the autonomic nervous system in stroke patients by using a heart rate variability measuring device. Methods: Thirty-nine participants were recruited and each participated in the high frequency electroacupuncture group, low frequency electroacupuncture group, manual acupuncture group and non-acupuncture group. Some participants received needle insertion with 100 Hz stimulation, with 2Hz stimulation and manual stimulation under mental arithmetic stress during 2 sections. Other participants maintained in the supine position without acupuncture under mental arithmetic stress during the 2 sections. Acupuncture needles were directly inserted perpendicularly to the right Liv 3 acupoint followed by delivery of electric pulses to these points for 8 minutes. Heart rate variability was measured 8 minutes before and 16 minutes after acupuncture stimulation by a heart rate variability measuring system. Results: We found a significant elevated HF total power between 1 section and 2 section and between 1 section and 4 section in the non-acupuncture group, between 3 section and 4 section in the 100Hz electroacupuncture group, and between 1 section and 2 section in the manual acupuncture group and with no change in the 2Hz electroacupuncture group. We also found a significant VLF total power between 2 section and 3 section in the 2Hz electroacupuncture group and between 1 section and 4 section and between 2 section and 4 section in the 100Hz electroacupuncture group. All four groups showed no significant differences in other parameters including heart rate mean, low-frequency power, and the ratio of low-frequency power to high-frequency power. Conclusions: This study may be a basis for research about effects of acupuncture and electroacupuncture because the parameters measured, heart rate variability, showed differences according to acupuncture.

Multi-rate MC-CDMA시스템에서의 코드 간 간섭과 주파수 다이버시티와의 관계에 대한 연구 (A Study on the Relation Between Frequency Diversity and Inter Code Interference in the Multi-rate MC-CDMA system)

  • 이규진;이계산;김진영
    • 한국ITS학회 논문지
    • /
    • 제7권5호
    • /
    • pp.131-138
    • /
    • 2008
  • 시스템의 성능은 RMS 지연확산과 도플러 주파수와 같은 채널 변수에 영향을 받는다. 이 논문은 Multi-rate MC-CDMA 시스템에서 주파수 다이버시티와 코드 간 간섭과의 관계에 대하여 연구하였다. Multi-rate MC-CDMA 시스템은 MC-CDMA 시스템보다 다양한 데이터율을 전송할 수 있는 장점이 있을 뿐 아니라, OFDMA와 다르게 주파수 다이버시티 이득을 얻음으로써 성능을 향상시킬 수 있다. 하지만, 확산코드를 사용함으로써 주파수 다이버시티 이득과 코드간 간섭간의 trade-off 관계가 있다. 그러므로 이러한 관계를 평가하여, 시스템을 효율적으로 사용함으로써 성능을 향상시킬 수 있다. 주파수 다이버시티 이득과 코드 간 간섭의 관계를 효과적으로 평가하기 위하여, 우리는 도플러 주파수와 RMS 지연확산을 변화시키며 모의실험을 수행하였고, 그 결과를 분석하였다.

  • PDF

이중 모드의 기준 클록을 사용하지 않는 클록 데이터 복원 회로 알고리즘 (Dual-Mode Reference-less Clock Data Recovery Algorithm)

  • 권기원;진자훈;전정훈
    • 전자공학회논문지
    • /
    • 제53권5호
    • /
    • pp.77-86
    • /
    • 2016
  • 본 논문에서는 full / half-rate의 이중 모드로 동작하는 기준 클록을 사용하지 않는 클록 데이터 복원 회로와 그 동작 알고리즘에 관하여 기술한다. 클록 데이터 복원 회로는 주파수 검출기, 위상 검출기, 차지 펌프 및 루프 필터, 그리고 전압 제어 발진기와 알고리즘 구현을 위한 디지털 블록으로 구성되어 있다. 주파수 검출기와 위상 검출기는 클록 데이터 복원 회로의 이중 모드 기능을 위하여 full / half-rate에서 동작하며 주파수 검출기는 이에 더해 일반 주파수 검출기의 불감대 영역에서도 데이터 전송률과 클록 주파수 차이를 판별할 수 있다. 제안한 이중 모드 클록 데이터 복원 회로를 시뮬레이션을 통해 검증한 결과 클록 데이터 복원에 전체 1.2-1.3 us의 동기화 시간이 소요되었으며, 0.5-UI 지터를 인가하였을 때 full-rate (2.7 Gb/s)와 half-rate (5.4 Gb/s) 모드에서 모두 안정적으로 클록 데이터를 복원한다.