• 제목/요약/키워드: frequency range

검색결과 7,076건 처리시간 0.031초

승용차량의 정차진동 주파수에 대한 불편함의 등감각곡선 (Equivalent Discomfort Curve on Idle Vibration Frequency of Passenger Vehicle)

  • 전경진;이재영;안세진;정의봉
    • 한국소음진동공학회논문집
    • /
    • 제22권6호
    • /
    • pp.535-541
    • /
    • 2012
  • The three-down one-up method which is commonly used in the field of psychophysics is employed in this study that is to reveal how much magnitude of vibration makes discomfort in passenger vehicle on idle condition. Thirteen taxi drivers were invited for subject of the experiment where they evaluated the controlled vibrations on rigid seat in terms of idle vibration on passenger vehicle at frequency range from 15 Hz to 40 Hz. As the result, vibration of 100~105 dB is marginal range to make discomfort on passenger seat. Frequency dependency of the discomfort was found at the frequency range, which is the higher frequency the lower discomfort with the same magnitude of vibration. The frequency dependency found here was compared with ISO 2631-1 that is more sensitive at the frequency range.

코히어런트 펄스열을 갖는 계단 주파수 레이더를 이용한 이동표적의 고해상도 거리 추정 분석 (Analysis of High Resolution Range Estimation for Moving Target Using Stepped Frequency Radar with Coherent Pulse Train)

  • 심재훈;배건성
    • 전기전자학회논문지
    • /
    • 제22권3호
    • /
    • pp.599-604
    • /
    • 2018
  • 계단 주파수 레이더는 송신 펄스의 주파수를 일정한 간격으로 증가시켜 넓은 합성 대역폭을 생성함으로써 고해상도 거리추정을 구현하는 방식이다. 그러나 이동표적의 경우에는 거리-도플러 결합 현상으로 인해 정확한 거리 추정이 어렵게 된다. 본 논문에서는 초기에 코히어런트 펄스열을 갖는 계단 주파수 레이더 파형을 이용하여 이동표적의 속도를 추정하고, 거리-도플러 결합 현상을 보상함으로써 얻어지는 고해상도 거리 추정 과정을 분석하고, 시뮬레이션을 통해 이를 검증하였다.

Seismic performance of emergency diesel generator for high frequency motions

  • Jeong, Young-Soo;Baek, Eun-Rim;Jeon, Bub-Gyu;Chang, Sung-Jin;Park, Dong-Uk
    • Nuclear Engineering and Technology
    • /
    • 제51권5호
    • /
    • pp.1470-1476
    • /
    • 2019
  • The nuclear power plants in South Korea have been designed in accordance with the U.S. Regulatory Guide 1.60 (R.G 1.60) design spectrum of which the peak frequency range is 2-10 Hz. The characteristics of the earthquakes at the Korea nuclear power plant sites were observed to be closer to that of Central and Eastern United States (CEUS) than the R.G 1.60, which is a lower amplification in a low frequency range, and a higher amplification in a high frequency range. The possibility of failure for sensitive power plant components in the high frequency range has been considered and evaluated. In this study, in order to improve the reliability of nuclear plant and administrative control procedures, seismic tests of an emergency diesel generator (EDG) were conducted using a shaking table under both high and low frequency ranges. From the tests, oil/lubricant leaks from the bolt connections, the fuel filter and the fuel inlet were observed. Therefore, the check list of nuclear plant components after an earthquake should include bolt connections of EDG as well as anchor bolts.

UWB 주파수 합성기용 1 GHz 광 대역 시그마 델타 성긴 튜닝형 전압 제어 발진기 (A 1 GHz Tuning range VCO with a Sigma-Delta Modulator for UWB Frequency Synthesizer)

  • 남철;박안수;박준성;부영건;허정;이강윤
    • 대한전자공학회논문지SD
    • /
    • 제47권8호
    • /
    • pp.64-72
    • /
    • 2010
  • 본 논문은 UWB주파수 합성기용 광대역 전압 제어 발진기로 시그마-델타 모듈레이션을 이용하여 미세한 성긴 튜닝을 구현하였다. 제안된 성긴 튜닝 방법은 위상 잡음 성능의 저하 없이 작은 유효 주파수 해상도를 제공한다. 3단계의 성긴 튜닝구조로 전압제어 발진기는 광대역과 미세 튜닝 단계를 동시에 구현한다. 본 전압 제어기를 포함한 주파수 합성기는 0.13 ${\mu}m$ CMOS공정으로 구현되었고, 5.8-6.8 GHz의 대역에 3.9 kHz의 유효 주파수 해상도를 갖는다. 측정된 위상 잡음은 1 MHz 오프셋에서 -108 dBc/Hz이고, 5.9 mW 전력 소모로 16.8 %의 튜닝 범위를 갖으며, 튜닝 범위를 갖는 Figure-of-merit(FoM)은 -181.58 dBc/Hz이다.

5MHz 초과 초음파자극기에 대한 IEC 61689 규격 적용의 유효성에 관한 연구 (A Study on Effectiveness of Application of the IEC 61689 Standard to Ultrasonic Physiotherapy Systems with Frequency Range over 5MHz)

  • 윤주신;최기상
    • 대한의용생체공학회:의공학회지
    • /
    • 제36권3호
    • /
    • pp.69-78
    • /
    • 2015
  • Ultrasonic physiotherapy systems should comply with IEC 60601-2-5(particular requirements for safety of ultrasonic physiotherapy equipment) standard for safety of patients and clinical performances. One of the most important parameters in the standard is the effective radiating area ($A_{ER}$). It has to be measured in accordance with IEC 61689 (field specifications and methods of measurement in the frequency range 0.5MHz to 5MHz). Typical ultrasonic physiotherapy system works in the frequency range 1MHz ~ 3MHz to comply with the IEC 61689. However, ultrasonic physiotherapy system using frequencies over 5MHz is out of the IEC 61689's scope. That is, even if such ultrasonic physiotherapy systems are developed by demands of the market, there is no standard to apply. It is the motivation for this study. Whereas there are other parameters to be considered, this study focuses on the effective radiating area and shows effectiveness of applying IEC 61689 in measuring effective radiating area of ultrasonic physiotherapy systems using frequency range over 5MHz by comparing the results of computer simulation and experiment. Results of this study shows that applying the IEC 61689 standard to ultrasonic physiotherapy system using frequency range over 5MHz is possible.

초음파를 이용한 경피약물수송의 촉진 (Enhancement of Transdermal Drug Delivery Using Ultrasound)

  • 박승규;김태열
    • The Journal of Korean Physical Therapy
    • /
    • 제13권3호
    • /
    • pp.719-726
    • /
    • 2001
  • Transdermal drug delivery offers various advantages over conventional drug delivery systems, such as avoidance gastrointestinal degradation and hepatic first-pass effect. encourages patient compliance. and possible sustained release of drugs. However, transdermal transport of drugs is low permeability of the stratum corneum, the superficial layer of the skin. Many physicochemical and biological factors influencing transdermal transport is described together with the corresponding experimental and clinical results. Phonophoresis is medical treatment with drugs introduced into the skin by ultrasound energy. Enhanced drug penetration is through to result from the biophysical alterations of skin structure by ultrasound waves. The frequency used for phonophoresis is usually from 20 kHz to 15MHz. Phonophoresis can be categorized in to three ranges: low-frequency range(below 1 MHz). therapeutic frequency range(1 to 3MHz), and high-frequency range(above 3 MHz). The depth of penetration of ultrasound into skin is inversely proportional to the frequency. Cavitation may cause mechanical stress. temperature elevation, or enhanced chemical reactivity causing drug transport. One theory is that ultrasound affects the permeation of the stratum corneum lipid structure as the limiting step in permeating through the skin. The range of indications for phonophoresis is wide. Aspecific classification of the range of indications is obtained by classification of pathological conditions. The continuous research is needed for many interesting issucs of phonophoretic transdermal delivory in new future.

  • PDF

A Wide Frequency Range LLC Resonant Controller IC with a Phase-Domain Resonance Deviation Prevention Circuit for LED Backlight Units

  • Park, YoungJun;Kim, Hongjin;Chun, Joo-Young;Lee, JooYoung;Pu, YoungGun;Lee, Kang-Yoon
    • Journal of Power Electronics
    • /
    • 제15권4호
    • /
    • pp.861-875
    • /
    • 2015
  • This paper presents a wide frequency range LLC resonant controller IC for LED backlight units. In this paper a new phase-domain resonance deviation prevention circuit (RDPC), which covers a wide frequency and input voltage range, is proposed. In addition, a wide range gate clock generator and an automatic dead time generator are proposed. The chip is fabricated using 0.35 μm BCD technology. The die size is 2 x 2 mm2. The frequency of the clock generator ranges from 38 kHz to 400 kHz, and the dead time ranges from 300 ns to 2 μs. The current consumption of the LLC resonant controller IC is 4 mA for a 100 kHz operation frequency using a supply voltage of 15 V.

곡관내 자성유체 PLUG의 진동특성 (The Oscillation Characteristics of a Magneticfluid Plug in Curved Tube)

  • 전운학;이행남
    • 한국자동차공학회논문집
    • /
    • 제3권3호
    • /
    • pp.46-57
    • /
    • 1995
  • The aim of the present study is to provide fundamental informations for the development of magneticfluid actuator. To achieve the aim, oscillation characteristics of the magneticfluid plug are investigated by experiment for the various length and position of the magneticfluid plug and the frequency of magnetic field. The oscillation characteristics are obtained. Amplitude, natural frequency, phase shift and damping ratio, are compared with theoretical values. From the study, the following conclusive remarks can be made. The experimental equation for the magnetic field is obtained. The critical magneticfluid length exists and its value is about 70mm. The range of the damping ratio and fluid loss coefficient obtained by experiment are 0.1~0.2 and 30~100, respectively. Comparison between experimental and theoretical results of oscillation characteristics shows good agreement in the high frequency range. Meanwhile, in the low frequency range, there appears little discrepancies(5% in the frequency and amplitude and 10% in phase difference and damping ratio) with each other.

  • PDF

Detection of Leakage Point via Frequency Analysis of a Pipeline Flow

  • Kim, Sanghyun;Wansuk Yoo;Injoon Kang
    • Journal of Mechanical Science and Technology
    • /
    • 제15권2호
    • /
    • pp.232-238
    • /
    • 2001
  • Fast Fourier Transformation is employed to convert the head variation of a pipeline in the time domain to the amplitude of the frequency domain. Applying method of characteristics to a pipeline provides a significant frequency range for a surge introduced from the valve modulation. Inverse Fast Fourier Transformation and a Finite Impulse Response Filter can be used to remove any possible noise existing from the significant frequency range of an unsteady condition. A filtered signal shows higher potential for the inverse calculation of leakage detection than the noise-added signal does. The respective performances of Inverse Fast Fourier Transformation and a Finite Impulse Response Filter are compared in terms of leakage detection capability. Characteristics of the frequency range for multiple leakages were investigated to validate the effectiveness of the noise control method in the frequency domain.

  • PDF

지중배전케이블에서 반도전층을 고려한 주파수 응답 및 전파특성 분석 (Analysis of Frequency Response Characteristic Considering Semiconducting Screen in Underground Distribution Cables)

  • 정채균;이종범;김정태
    • 전기학회논문지
    • /
    • 제61권8호
    • /
    • pp.1091-1098
    • /
    • 2012
  • This paper describes frequency response and propagation characteristics considering semiconducting screen in distribution cables. In CIGRE WG 21-05, Simplified Approach(SA) and Rigorous Approach(RA) which can revise the permittivity considering semiconducting screen propose for more detailed EMTP model and frequency dependant analysis. In this paper, the frequency dependent characteristics of complex permittivity are variously analysed by cole-cole function of RA. The attenuation, propagation velocity and surge impedance according to frequency range(1 kHz to 500 MHz) and cable length are also analysed by SA and EMTP simulation in distribution cables. The propagation velocity considering semiconducting screen is slower, and it is saturated over the range of 1 MHz. The signal is significantly attenuated as frequency range is high.