• Title/Summary/Keyword: frequency problem

Search Result 3,569, Processing Time 0.038 seconds

Paternity Diagnosis using The Multiplex PCR with Microsatellite Markers in Dogs

  • Kim, Seung-Chang;Jang, Hong-Chul;Kim, Lee-Kyung;Lim, Da-Jeong;Lee, Seung-Hwan;Cho, Yong-Min;Kim, Tae-Hun;Seong, Hwan-Hoo;Oh, Sung-Jong;Choi, Bong-Hwan
    • Reproductive and Developmental Biology
    • /
    • v.35 no.4
    • /
    • pp.399-405
    • /
    • 2011
  • The number of abandoned dogs is increasing with the worsening of the economy and the rising of feed value. It was becoming a serious social problem because of the disease transmission and destruction of natural ecosystems by abandoned dogs been wild animal. In order to solve these problems, companion dogs necessary to secure its own genetic information and to establish the systematic tracking system. Using multiplex-PCR method with 27 microsatellite marker (MS marker) divided 3 set, various alleles occurring to 6 dog breed (Labrador Retriever, German Shepherd, English Springer Spaniel, Belgian Malinois, Jindo Dog, PoongSan Dog) make use of markers to determine allele frequency and heterozygosity. MS marker FH2834 and FH2790 have only two allele and most were found in 13 alleles at FH3381 and FH3399. Average heterozygosity of MS marker is 0.534 and especially, heterozygosity represented the highest value of 0.765 at FH3381. So, it was recognized appropriate allele frequency for individual identification and paternity diagnosis in companion dogs. Using multiplex-PCR method with MS marker, various alleles occurring to dog breed make use of markers to deter mine individual identification and paternity diagnosis, traits associated biomarkers and breed-specific marker for faster, more accurate and ways to reduce the analysis cost. Based on this result, a scientific basis was established to the existing pedigree data by applying genetics additionally. Animal registration system is expected to be conducted nationwide in future. The method expects to very useful this system.

THE EFFECT OF AUTOCLAVE STERILIZATION AND REUSE OF $SMARTPEG^{TM}$ ON THE IMPLANT STABILITY QUOTIENT (ISQ) MEASUREMENT ($Smartpeg^{TM}$의 고압멸균소독 및 재사용이 임플랜트 안정성 지수(ISQ) 측정에 미치는 영향)

  • Kang, In-Ho;Kim, Myung-Joo;Lim, Young-Jun;Kim, Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.5
    • /
    • pp.644-652
    • /
    • 2007
  • Statement of problem: Resonance frequency analysis is evaluated as the non-invasive and objective method for the evaluation of implant stability and has been increasingly used. It is necessary to evaluate the factors affect the ISQ measurement stability. Purpose: This study was performed to evaluate the effect of the autoclave sterilization and reuse of $Smartpeg^{TM}$ on ISQ measurement. Material and methods: $SmartPeg^{TM}$ (Integration Diagnostics Ltd., $G\ddot{o}teborg$, Sweden) of autoclave group (A) was autoclave sterilized 9 times and $Smartpeg^{TM}$ of reuse group (R) was reused 9 times. Ten $SmartPeg^{TM}s$ were allocated to each group and after each autoclave sterilization and reuse, implant stability quotient (ISQ) values were measured 3 times from the two directions a and b at a right angle. $Osstell^{TM}$ mentor (Integration Diagnostics Ltd. $G\ddot{o}teborg$, Sweden) was used and type 1 (article no. 100353) $Smartpeg^{TM}$ was selected according to $Smartpeg^{TM}$ reference list. Osstem Implant US II future (Osstem Co., Seoul, Korea) in $4.0mm{\times}11.5mm$ was embedded in the self-curing acrylic resin ($Orthojet^{(R)}$, Lang Dental, U.S.A.). Data was statistically analyzed by one-way ANOVA $({\alpha}=.05)$ and scheffe test was done where a significant difference exist. Correlation test was also done between ISQ value and the number of autoclave sterilization or reuse. Results: 1. In autoclave group, the means and sd. of ISQ value before autoclave sterilization were $84.97{\pm}0.41,\;84.93{\pm}0.74$ at direction a and b. There was significant differences between autoclave groups at direction a and b (P=.000). 2. In reuse group, the means and sd. of ISQ value before reuse were $85.40{\pm}0.62,\;85.50{\pm}0.57$ at direction a and b. There was no significant difference between reuse groups at direction a and b (P>.05). 3. There was a weak positive correlation between the number of reuse and ISQ value at direction a and b (${\gamma}=.207$ and .246, P<.01). Conclusion: Within the limitations of this study, the following conclusions were drawn. Till ninth reuse of $Smartpeg^{TM}$, the ISQ measurement stability did not be affected. After twice autoclave sterilization of $Smartpeg^{TM}$ the ISQ measurement stability was affected.

Analysis of the Science Words Used by Science Teachers in Teaching the Unit of 'Force and Motion' (중학교 과학 교사가 '힘과 운동' 단원 수업 중에 사용하는 과학용어 분석)

  • Yun, Eunjeong;Park, Yunebae
    • Journal of The Korean Association For Science Education
    • /
    • v.35 no.2
    • /
    • pp.209-216
    • /
    • 2015
  • In science classrooms, using science terminology is a very important aspect of communications between science teachers and students, as well as in the science learning of students. This study was conducted to investigate the usage of the science terminology in the lectures of science teachers, and identify the problem in the aspect of both communication and teaching. To do this, we have recorded 13 hours of class teaching 'Motion' part in unit of 'Force and Motion' from three science teachers, and extracted science terminologies from the science teachers' lectures by using an analysis program. We performed qualitative analysis, such as kind of science terminology used, and linkage between curriculum and textbook, and quantitative analysis, such as number of science terminology, and frequency of use. With respect to communication, there appears some problems in its proportion in the teacher's lecture in class. It is deemed that science terminology in teachers' lectures were too many, that the frequency of usage of important conceptual terminology was low, and that teachers use higher level terminologies to explain key concepts. And in respect to science learning, there were problems where terminologies including important concepts were used separately by the teachers and textbooks, terminologies of higher level concept were used, and there might be differences between teachers in majority of teachers.

THREE-SITE PHOTOMETRIC MONITORING OF THE δ SCT-TYPE PULSATING STAR V1162 ORIONIS : PERIOD CHANGE AND ITS IMPLICATIONS FOR PRE-MAIN SEQUENCE EVOLUTION

  • KIM, SEUNG-LEE;CHA, SANG-MOK;LIM, BEOMDU;LEE, JAE WOO;LEE, CHUNG-UK;LEE, YONGSEOK;KIM, DONG-JIN;LEE, DONG-JOO;KOO, JAE-RIM;HONG, KYEONGSOO;RYU, YOON-HYUN;PARK, BYEONG-GON
    • Journal of The Korean Astronomical Society
    • /
    • v.49 no.5
    • /
    • pp.199-208
    • /
    • 2016
  • We present photometric results of the δ Sct star V1162 Ori, which is extensively monitored for a total of 49 nights from mid-December 2014 to early-March 2015. The observations are made with three KMTNet (Korea Microlensing Telescope Network) 1.6 m telescopes installed in Chile, South Africa, and Australia. Multiple frequency analysis is applied to the data and resulted in clear detection of seven frequencies without an alias problem: five known frequencies and two new ones with small amplitudes of 1.2-1.7 mmag. The amplitudes of all but one frequency are significantly different from previous results, confirming the existence of long-term amplitude changes. We examine the variations in pulsation timings of V1162 Ori for about 30 years by using the times of maximum light obtained from our data and collected from the literatures. The O − C (Observed minus Calculated) timing diagram shows a combination of a downward parabolic variation with a period decreasing rate of (1/P)dP/dt = −4.22 × 10−6 year−1 and a cyclic change with a period of about 2780 days. The most probable explanation for this cyclic variation is the light-travel-time effect caused by an unknown binary companion, which has a minimum mass of 0.69 M. V1162 Ori is the first δ Sct-type pulsating star of which the observed fast period decrease can be interpreted as an evolutionary effect of a pre-main sequence star, considering its membership of the Orion OB 1c association.

Histopathological and Clinical Studies of the 387 Cases of Salivary Gland Epithelial Tumors (타액선 상피성 종양 387례에 대한 연구)

  • Chae, Sung-Won;Choi, Geon;Choi, Jong-Sang;Song, Jae-Jun;Jung, Kwang-Yoon;Choi, Jong-Ouck
    • Korean Journal of Bronchoesophagology
    • /
    • v.4 no.2
    • /
    • pp.211-218
    • /
    • 1998
  • There have been few large scale surveys of salivary gland tumors, because the salivary gland tumors comprised less than 3 percent of all neoplasms of the head and neck. Also there is a problem that the incidences of specific types of tumors have the variation according to the geographic regions. ]'nother Korean reports about salivary gland tumor, they only treated about 100 cases only. Objectives : The purpose of this study is to identify the frequency and clinical characteristics of salivary gland tumors and to compare with other Korean reports. Materials and Methods : We had performed to analyze 387 cases of salivary gland tumors from 1983 to June 1997, were reviewed in histopathological and clinical aspects. The diagnoses of individual tumors were based on the World Health Organization classification. Tumors were analyzed according to the histologic type site, age and sex. Results : The majority (79.1%) of cases occurred in the major salivary glands and 20.9% in the minor. The parotid gland was the most frequent site with 52.4% and submandibular glands with 26.3%. Benign tumors were 79.3% of the tumors and malignant tmon were 20.7%. The most frequent tumor was pleomorphic adenoma occupied 63.8% of the total and frequency percent of histologic type of 98 malignant tumors showed 35.7% of mucoepidermoid carcinomas, 24.5% of adenoid cystic carcinomas. Overall gender with female predominance with 1 : 1.4 of male to female ratio. The average age of patients was 42.8 years. The most frequent chief complaint was a palpable mass. The duration of the symptom was shorter in the malignant salivary gland tumors (26.7 months) than in the benign salivary gland tumors (38.2 months). Conclusion : Comparing to the previous Korean reports, the present study confirms that the incidence of salivary gland tumor was lower in the parotid gland, and was higher in the submandibular and minor salivary glands.

  • PDF

Development of spatial dependence formula of FORGEX method using rainfall data in Korea (우리나라 강우 자료를 이용한 FORGEX 기법의 공간상관식 개발)

  • Kim, Sunghun;Ahn, Hyunjun;Shin, Hongjoon;Heo, Jun-Haeng
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.12
    • /
    • pp.1007-1014
    • /
    • 2016
  • The FORGEX (Focused Rainfall Growth Extension) method was developed to estimate rainfall quantiles in the United Kingdom. This method does not need any regional grouping and can estimate rainfall quantiles with relatively long return period. The spatial dependence formula (ln $N_e$) was derived to consider the distance from growth curve of proper population to the distributed network maximum (netmax) data using the UK rainfall data. For this reason, there is an inaccurate problem in rainfall quantiles when this formula is applied in Korea. In this study, the new formula was derived in order to improve such shortcomings using rainfall data of 64 sites from the Korea Meteorological Administration (KMA). A 42-year period (1973~2014) was taken as the reference period from rainfall data, then the formula was derived using three parameters such as rainfall duration, number of site, area of network. Then the new formula was applied to the FORGEX method for regional rainfall frequency analysis. In addition, rainfall quantiles were compared with those from the UK formula. As a result, the new formula shows more accurate results than the UK formula, in which the FORGEX method by the UK formula underestimates rainfall quantiles. Finally, the new improved formula may estimate accurate rainfall quantiles for long return period.

Biomechanical evaluation of dental implants with different surfaces: Removal torque and resonance frequency analysis in rabbits

  • Koh, Jung-Woo;Yang, Jae-Ho;Han, Jung-Suk;Lee, Jai-Bong;Kim, Sung-Hun
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.2
    • /
    • pp.107-112
    • /
    • 2009
  • STATEMENT OF PROBLEM. Macroscopic and especially microscopic properties of implant surfaces play a major role in the osseous healing of dental implants. Dental implants with modified surfaces have shown stronger osseointegration than implants which are only turned (machined). Advanced surface modification techniques such as anodic oxidation and Ca-P application have been developed to achieve faster and stronger bonding between the host bone and the implant. PURPOSE. The purpose of this study was to investigate the effect of surface treatment of titanium dental implant on implant stability after insertion using the rabbit tibia model. MATERIAL AND METHODS. Three test groups were prepared: sandblasted, large-grit and acid-etched (SLA) implants, anodic oxidized implants, and anodized implants with Ca-P immersion. The turned implants served as control. Twenty rabbits received 80 implants in the tibia. Resonance frequencies were measured at the time of implant insertion, 2 weeks and 4 weeks of healing. Removal torque values (RTV) were measured 2 and 4 weeks after insertion. RESULTS. The implant stability quotient (ISQ) values of implants for resonance frequency analysis (RFA) increased significantly (P <. 05) during 2 weeks of healing period although there were no significant differences among the test and control groups (P >. 05). The test and control implants also showed significantly higher ISQ values during 4 weeks of healing period (P < .05). No significant differences, however, were found among all the groups. All the groups showed no significant differences in ISQ values between 2 and 4 weeks after implant insertion (P >. 05). The SLA, anodized and Ca-P immersed implants showed higher RTVs at 2 and 4 weeks of healing than the machined one (P < .05). However, there was no significant difference among the experimental groups. CONCLUSION. The surface-modified implants appear to provide superior implant stability to the turned one. Under the limitation of this study, however, we suggest that neither anodic oxidation nor Ca-P immersion techniques have any advantage over the conventional SLA technique with respect to implant stability.

BONE RESPONSE OF THREE DIFFERENT SURFACE IMPLANTS : HISTOMORPHOMETRIC, PERIO TEST VALUE AND RESONANCE FREQUENCY ANALYSIS IN BEAGLE DOGS

  • Choi, Joon-Eon;Suh, Kyu-Won;Lee, In-Ku;Ryu, Jae-Jun;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.3
    • /
    • pp.362-374
    • /
    • 2007
  • Statement of problem. The intial stability for osseointegration of implant has been an interesting factor. Especially, in the case of poor bone quality or immediately loaded implant, various strategies have been developed focusing on the surface of materials to improve implant fixation to bone. The microscopic properties of implant surfaces play a major role in the osseous healing of dental implants. Purpose. The aims of this study are to perform a histologic and histomorphometric comparison of the healing characteristics of three different surfaces and the comparison of resonance frequency analysis (RFA) values measured by $Osstell^{TM}$ and perio-test values (PTV) measured by Periotest. Material and methods. A total of 24 screw titanium implants (Dentium Co., Seoul, Korea) with 6mm in length and 3.4mm in diameter, were placed in the mandible of 4 beagle dogs. Implants were divided into three groups following the surface treatment methods: Group I is machined(control group). Group II is anodically oxidized. Group III is coated 500nm in thickness with hydroxyapatite(HA) by ion beam assisted deposition(IBAD) on the anodized oxidization. Bone blocks from 2 dogs were caught after 3 weeks of covered healing and another blocks from 2 dogs after 6 weeks. RFA values and PTV were measured right after insertion and at 3 and 6weeks. Histomorphometric analysis was made with Kappa Image Base System to calculate bone-to-implant contact (BIC) and bone area inside the threads. Pearson's correlation analyses were performed to evaluate the correlation between RFA and PTV, BIC and bone area ratio of three different surfaces at 3 and 6 weeks. Results. 1) In all surface treatment methods, the RFA values decreased and the PTV values increased until 6 weeks in comparison to initial values. 2) At 3 weeks, no significant difference was found from bone-to-implant contact ratio and bone area ratio of three different surface treatment methods(P>0.05). However, at 6 weeks, different surface treatment methods showed significantly different bone-toimplant contact ratio and bone area ratio(P<0.05). 3) In the implants with the IBAD on the anodic oxidization, significant difference was found between the 3 weeks and the 6 weeks bone area ratio(P<0.05). 4) Correlation was found between the RFA values and the bone area ratio at 3 and 6 weeks with significant difference(P<0.05). Conclusions. These results indicate that the implants with the IBAD on the anodic oxidization may have a high influence on the initial stability of implant.

Live Lines Tracing Method in Power Distribution System with 3-phase-4 wires (삼상 다중 접지 배전계통에서 활선로 추적 방법)

  • Zheng, Yan-peng;Byun, Hee-Jung;Shon, Sugoog
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.559-562
    • /
    • 2017
  • In city, tracing of power transmission lines is difficult due to compound installation of overhead and underground lines, transposition, bad view caused by trees or big buildings. It is hard problem for electrical technician on site to trace power transformers or power lines to serve customers in 3 phase -4 wires power distribution systems. It is necessary that the correct and fast tracing method is required for load balancing among distribution lines. Old technology use to trace off-lines with high power impulse injection. Our proposed method use to trace live lines with very small power high frequency signal injection. Typical power transformers in the distribution system prevent propagating the higher frequency carrier signal. The proposed method uses the limited propagation ability to identify the power transformer to serve customers. Two end communication terminals are required to be synchronized between them for determination on electrically same phases. Challenging issue is to achieve synchronization without GPS providing synchronizing time. A novel power transformer and wire identification system is designed and implemented. The system consists of a transmitter and a receiver with power-line communication module. Some experiments are conducted to verify the theoretical concepts in a big commercial building. Also some simulations are done to help and understand the concepts by using MATLAB Simulink simulator.

  • PDF

A Tag Flow-Driven Deployment Simulator for Developing RFID Applications (RFID 애플리케이션 개발을 위한 태그 흐름기반 배치 시뮬레이터)

  • Moon, Mi-Kyeong
    • The KIPS Transactions:PartD
    • /
    • v.17D no.2
    • /
    • pp.157-166
    • /
    • 2010
  • More recently, RFID (Radio Frequency Identification) systems have begun to find greater use in various industrial fields. The use of RFID system in these application domains has been promoted by efforts to develop the RFID tags which are low in cost, small in size, and high in performance. The RFID applications enable the real-time capture and update of RFID tag information, while simultaneously allowing business process change through real-time alerting and alarms. These be developed to monitor person or objects with RFID tags in a place and to provide visibility and traceability of the seamless flows of RFID tags. In this time, the RFID readers should be placed in diverse locations, the RFID flows between these readers can be tested based on various scenarios. However, due to the high cost of RFID readers, it may be difficult to prepare the similar environment equipped with RFID read/write devices. In this paper, we propose a simulator to allow RFID application testing without installing physical devices. It can model the RFID deployment environment, place various RFID readers and sensors on this model, and move the RFID tags through the business processes. This simulator can improve the software development productivity by accurately testing RFID middleware and applications. In addition, when data security cannot be ensured by any fault, it can decide where the problem is occurred between RFID hardware and middleware.