• Title/Summary/Keyword: frequency of occurrence

Search Result 1,422, Processing Time 0.031 seconds

VSimulators: A New UK-based Immersive Experimental Facility for Studying Occupant Response to Wind-induced Motion of Tall Buildings

  • Antony Darby;James Brownjohn;Erfan Shahabpoor;Kaveh Heshmati
    • International Journal of High-Rise Buildings
    • /
    • v.11 no.4
    • /
    • pp.347-362
    • /
    • 2022
  • Current vibration serviceability assessment criteria for wind-induced vibrations in tall buildings are based largely on human 'perception' thresholds which are shown not to be directly translatable to human 'acceptability' of vibrations. There is also a considerable debate about both the metrics and criteria for vibration acceptability, such as frequency of occurrence or peak vs mean vibration, and how these might vary with the nature of the vibration. Furthermore, the design criteria are necessarily simplified for ease of application so cannot account for a range of environmental, situational and human factors that may enhance or diminish the impact of vibrations on serviceability. The dual-site VSimulators facility was created specifically to provide an experimental platform to address gaps in understanding of human response to building vibration. This paper considers how VSimulators can be used to inform general design guidance and support design of specific buildings for habitability, in terms of vibration, which allow engineers and clients to make informed decisions with regard to sustainable design, in terms of energy and financial cost. This paper first provides a brief overview of current vibration serviceability assessment guidelines, and the current understanding and limitations of occupants' acceptability of wind-induced motion in tall buildings. It then describes how the dual-site VSimulators facility at the Universities of Bath and Exeter can be used to assess the effects of motion and environment on human comfort, wellbeing and productivity with examples of how the facility capabilities have been used to provide new, human experience based experimental research approaches.

Prescription, Transcription and Administration Errors in Out-Patient Day Care Unit of a Regional Cancer Centre in South India

  • Mathaiyan, Jayanthi;Jain, Tanvi;Dubashi, Biswajit;Batmanabane, Gitanjali
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.5
    • /
    • pp.2611-2617
    • /
    • 2016
  • Background: Medication errors are common but most often preventable events in any health care setup. Studies on medication errors involving chemotherapeutic drugs are limited. Objective: We studied three aspects of medication errors - prescription, transcription and administration errors in 500 cancer patients who received ambulatory cancer chemotherapy at a resource limited setting government hospital attached cancer centre in South India. The frequency of medication errors, their types and the possible reasons for their occurrence were analysed. Design and Methods: Cross-sectional study using direct observation and chart review in anmbulatory day care unit of a Regional Cancer Centre in South India. Prescription charts of 500 patients during a three month time period were studied and errors analysed. Transcription errors were estimated from the nurses records for these 500 patients who were prescribed anticancer medications or premedication to be administered in the day care centre, direct observations were made during drug administration and administration errors analysed. Medical oncologists prescribing anticancer medications and nurses administering medications also participated. Results: A total of 500 patient observations were made and 41.6% medication errors were detected. Among the total observed errors, 114 (54.8%) were prescription errors, 51(24.5%) were transcribing errors and 43 (20.7%) were administration errors. The majority of the prescription errors were due to missing information (45.5%) and administration errors were mainly due to errors in drug reconstitution (55.8%). There were no life threatening events during the observation period since most of the errors were either intercepted before reaching the patient or were trivial. Conclusions: A high rate of potentially harmful medication errors were intercepted at the ambulatory day care unit of our regional cancer centre. Suggestions have been made to reduce errors in the future by adoption of computerised prescriptions and periodic sensitisation of the responsible health personnel.

Freshwater Algae in the Upstream of the Yongsan River System(1) -on the Drinking Water Supplying Area of Kwangju Districts- (영산강 상류의 담수조류 분포에 관한 연구(1) - 광주지역 상수원을 중심으로 -)

  • 최민규;김백호;최규철
    • Journal of environmental and Sanitary engineering
    • /
    • v.10 no.1
    • /
    • pp.45-65
    • /
    • 1995
  • Seasonal occurrences and dynamics on the freshwater algae were examined in the upstream of the Yongsan river system with the Kwangju service water area from 1993 to 1994. Three hundred and three taxi were totally collected and composed of 6 classes, 15 orders, 7 suborders, 31 families, 74 genera, 248 species, 48 varieties and 7 forma. Compositions in each algal class were divided in 136 taxi of Chlorophyceae(44.8% ), 109 taxi of Bacillariophyceae(36.0% ), 30 taxa of Cyanophyceae(10.1% ), 21 taxa of Euglenophyceae(6. 9% ),4 taxi of Chrysophyceae(1.3% ) and 3 taxa of Dinophyceae(1.0% ). The occurrence of taxa was a markedly decrease(-62) between summer and autumn, the critically increase(+43) between spring and summer. And also, it was indicated that the high frequency of taxa in summer, but the high standing biomass In winter in spite of low taxi. In general, it has much algal biomass in station 9 and 10, but low in station 4, 5 and 11, relatively. Through this survey, the major dominant taxa in algal biomass, Microcystis aeruginosa, Melosira varians, Synedra ulna and Navicula cryptocephala, they were all above 2.1×10$^{6}$ce11s/1, 13.2% of totals. There are about 10% of new emigrated taxa by season and they showed a remarkable succession. We may suggested that this system was well sustained for the habitat of freshwater algal community with low dominance and high diversity. Twenty three of nuisance algae including of Microcystis aeruginosa, Peridinium willei and Anabaena flos-aquae were distributed as if had low appearance. Of course, many of them were saprobiontic taxa, extraordinary growttung groups depend on organic loading in water system and also it was not showed severe algal blooming phenomenon.

  • PDF

Sectors from Phyricularia grisea Isolates on Edifenphos and Iprobenfos-Amended Media

  • Kim, Yun-Sung;Baik, Jong-Min;Kim, Eui-Nam;Kim, Ki-Deok
    • The Plant Pathology Journal
    • /
    • v.20 no.4
    • /
    • pp.244-246
    • /
    • 2004
  • Sectors of rice blast fungus, Pyricularia grisea, frequently appeared on potato dextrose agar amended with edifenphos and iprobenfos. Thus, we assessed the sector-forming frequency of isolates of P. grisea and compared the fungicide sensitivity between wild types and sectors against the fungicides. The 905 isolates of the fungus were obtained from rice-growing locations in Korea from 1997-1998. When the isolates were grown on potato dextrose agar amended with minimal inhibitory concentrations of edifenphos (20 ${\mu}$g a.i./ml)and iprobenfos (55 ${\mu}$g a.i./ml), they produced sectors that overcame the effect of the fungicides. Among the 905 isolates tested, 9.0% produced sectors against edifenphos and 5.6%, against iprobenfos. Different sector-forming frequencies were also observed among the 11 locations of Korea. Sectors obtained from the fungicide-amended media generally grew more than their counterpart wild types grown on the media with either edifenphos or iprobenfos, regardless of their origins. In this study, greater relative growth of sectors over wild types of tested isolates can support the resistant characteristic of the fungus to survive against the fungicides. Therefore, the results indicate that the sectoring in rice blast fungus, P. grisea, may play a role in the occurrence of fungicide resistance.

A Comparative Study of Medicinal and Acupuncture Treatment -Based on Terms of the Efficacy and the Method of Treatment- (한약 치료와 침구 치료에 대한 비교 연구 - 효능(혈성)·치법 용어를 중심으로 -)

  • Kim, Sanghyun;Oh, Yongtaek;Kim, An-na;Kim, Sangkyun;Seo, Jinsun;Jang, Hyunchul
    • The Journal of Korean Medicine
    • /
    • v.37 no.3
    • /
    • pp.87-96
    • /
    • 2016
  • Objectives: Through this study, it would be expected to compare the characteristics of medicinal and acupuncture treatment. Method: Ontology DB of traditional Korean medicine has been used comparing medicinal and acupuncture treatment. Terms of the efficacy and the method of treatment were divided to predicate and object. And two groups were compared through contrasting the frequency of occurrence of significant words. Results: Predicates utilized more in medicinal treatment are the character ryeom[斂], go[固], pa[破], nae[內], and tu [透]. Predicates utilized more in acupuncture treatment are the character so[疏], jo[調], and seo[舒]. Object utilized more in acupuncture treatment is the character gi[氣]. Object utilized more in medicinal treatment is the character jeong[精]. Conclusions: In terms about the efficacy of acupuncture, there are many expressions associated with Qi[氣]. But expressions associated with Jing[精] are rare compare to medicinal treatment. There is a difference in language that represents the efficacy between medicinal and acupuncture treatment. In addition, there are some terms about efficacy that are not shared with each other due to the differences in disease treatment and the different branches of the two theories.

Evaluation of HACCP system implementation in meat packaging industry (식육포장처리업의 HACCP 운용실태 분석)

  • Kang, Cheon-Kun;Hong, Chong-Hae
    • Korean Journal of Veterinary Service
    • /
    • v.36 no.4
    • /
    • pp.291-296
    • /
    • 2013
  • The purpose of this study was to determine food safety practices and procedures based on Hazard Analysis Critical Control Point (HACCP) system and to suggest more effective method of HACCP implementation in meat packaging industry in Korea. We used the non-compliance rate of each evaluation item to compare the weak points of prerequisite requirements and HACCP. The prerequisite items related to facility, equipment, and tools showed inadequate level of requirements or unsanitary conditions for proper HACCP operation. A lack of understanding of sanitation standard operation procedures was identified as a fundamental barrier to HACCP implementation. High rate of non-compliance in HACCP items compared to prerequisite requirements signify that small businesses have potential difficulties of applying HACCP due to lack of technical expertise, financial resources for prerequisite requirements, and available personnel to prepare and operate HACCP plan. Also we suggest to revise and minimize current critical control points (CCPs). Time-temperature control of cold-storage rooms for carcasses and final products could be performed by control points of prerequisite requirements. As the occurrence frequency getting lower, metal detector should be replaced by intensified training of sanitary handling and safety procedure. This will be more effective and preventive measures against physical contaminants including metal particles. In conclusion, control point of prerequisite requirement may replace CCP in the plant with simple processing line and no heating process such as meat packaging industry.

Effects of Lightning Surges on the Life of ZnO Varistors (뇌서지가 ZnO바리스터에 미치는 영향)

  • Lee, Bong;Lee, Su-Bong;Kang, Sung-Man;Lee, Bok-Hee
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.5
    • /
    • pp.257-262
    • /
    • 2006
  • To evaluate the change in protective levels of zinc oxide (ZnO) varistors after the surge absorption, this paper investigated the effects of the number of injection and amplitude of lightning surges on the life of ZnO varistors for low voltages. Leakage currents flowing through ZnO varistors subjected to the $8/20{\mu}s$ impulse currents under 60 Hz AC voltages were measured. The surge simulator system ECAT that can generate $8/20{\mu}s$ impulse currents with a peak short-circuit of 5 $[kA_p]$ was used. The ZnO varistor leakage current increases with exposure to impulse current, and the number of injection of $8/20{\mu}s$ impulse currents to breakdown was inversely proportional to the amplitude of the test current. Behaviors of ZnO varistor leakage currents were strongly dependent on the number of injection and amplitude of $8/20{\mu}s$ impulse currents. ZnO varistors degrade gradually when subjected to impulse current, and the resistive leakage current flowing through ZnO varistors subjected to the $8/20{\mu}s$ impulse currents under 60 Hz AC voltages was significantly increased after a certain number of injection that is dependent on the amplitude of the test impulse current. As a result, the life of ZnO varistors mainly depends on the amplitude and occurrence frequency of lightning surges.

Application of Coliform Bacterial Plasmid as a Trophic Indicator (콜리형 세균 Plasmid의 영양단계 지표 활용에 관한 연구)

  • Cho, Hong Bum
    • The Korean Journal of Ecology
    • /
    • v.11 no.1
    • /
    • pp.29-36
    • /
    • 1988
  • This present study has been carried out to examine the correlation between the distribution of the coliform bacterial plasmids and the viability test against heavy metals in the upper stream of Han river(Gapyung; clean water) and the its basin (Anyang Cheon; polluted water). And the distribution of plasmids were examined to be used as trophic indicator for analysis between the clean and polluted waters. 1. A total of 110 isolates were analyzed for the presence of plasmids by means of the boiling method and agarose gel techniques. Plasmids were significantly more frequent in the strains which had been isolated from the clean water (14.3%). Also, there were much higher multiplicity of plasmids at the polluted water(41.0%), compared with the clean water (33.0%). By the comparision between molecular weight of bacterial plasmids in the clean water and those of polluted water, there were no significant differences of the clean water from the polluted water, to such extent as 30.0%, 28.6%, respectively, in frequency for occurrence of high molecular weight plasmids iver 35.8% Mdal. 2. Each isolate was carried out the resistance test for mercury(10-5M), nickel(10-3M) and arsenic (0.1%). At the polluted site, the survival ability of the plasmid-carrying straings(Hg, 31.0%l Ni, 5.7%; As, 65.7%) was higher than that of the non plasmid-carrying strains(Hg, 12.1%; Ni, 3.0%; As, 54.6%). This trend was more remarkable in the clean site (plasmid-carrying strains: 16.7%,-,-). As a result it is suggested that plasmids could be used as an indicator of a certain types of water pollution. In addition, heavy metals might have inflyenced, some extent, to the distribution of plasmids in the environment which has been surveyed in the present study.

  • PDF

Analysis of characteristics of sediment transport in sewers by densimetric Froude number (밀도프루드수에 의한 하수관로 침전물 이송 특성 분석)

  • Park, Kyoohong;Lee, Taehoon;Yu, Soonyu;Kang, Byongjun;Hyun, Kirim
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.1
    • /
    • pp.45-52
    • /
    • 2020
  • Even though sewers have been conventionally designed to prevent from sediment deposition using a specified minimum velocity or shear stress at a particular depth of flow or with a particular frequency of occurrence, it was appreciated that these methods do not consider the characteristics and concentration of the sediment and the specific hydraulic conditions of the sewer with sediment. In this study, a densimetric Froude number formula was suggested considering particle diameter and volumetric concentration of the sediment as well as flow depth and flowrate, based on several domestic field inspections, which was compared with other formulas proposed by previous investigators. When the sediment concentration was not considered, the calibration coefficient of 0.125-1.5 to the densimetric Froude numbers of this study was needed to obtain the similar ones with previous investigators'. For the densimetric Froude number formula obtained with consideration of sediment concentration, the exponent value of term Cv was almost the same as that of previous results and that of d50/Rh was similar for Fr < 2.2.

Usefulness of Dexmedetomidine during Intracerebral Aneurysm Coiling

  • Lee, Hyoun-Ho;Jung, Young-Jin;Choi, Byung-Yon;Chang, Chul-Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.55 no.4
    • /
    • pp.185-189
    • /
    • 2014
  • Objective : General anesthesia is often preferred for endovascular coiling of intracranial aneurysm at most centers. But in the authors' hospital, it is performed under monitored anesthesia care (MAC) using dexmedetomidine. To determine the feasibility and safety of this approach, the authors reviewed our initial experience. Methods : Retrospective data was analyzed from July 2012 to November 2012. We performed coil embolization in 28 cases using this method. Among them, for statistical significance, we analyzed 12 cases in which the procedure time exceeded an hour. Vital signs were analyzed every 10 minutes. Depth of sedation was measured according to the Ramsay sedation scale and frequency of the repeated roadmap image(s) caused by movement of the patient's head during the procedure. Results : All procedures were completed without occurrence of procedure related complications. Under MAC using dexmedetomidine, vital signs of the patients were stable, no statistical significance regarding hemodynamic and respiratory parameters was observed between time points (p>0.05). Adequate sedation was achieved. Mean Ramsay sedation scale was $3.67{\pm}1.61$ (2 to 6). Repeated roadmap image(s) due to patient's factor occurred in only one case. The mean dosage of drug for adequate sedation for the procedure was $0.65{\pm}0.12mcg/kg/hr$ without loading doses. Conclusion : To the best of my knowledge, this is the first report published in English using the method of monitored anesthesia with dexmedetomidine for intracranial aneurysm coiling. Monitored anesthesia care using dexmedetomidine without loading dose for embolization of intracranial aneurysms appeared to be a safe and effective alternative to general anesthesia.