• Title/Summary/Keyword: frequency measurement

Search Result 4,257, Processing Time 0.031 seconds

A Study on the Portable Micro Displacement Measurement Using Laser Interferometer (레이저 간섭계를 이용한 이동형 미세 변위 측정에 관한 연구)

  • Choi, K.H.;Yang, H.C.
    • Journal of Power System Engineering
    • /
    • v.10 no.2
    • /
    • pp.99-103
    • /
    • 2006
  • The laser interferometer has been used for measurement of the micro displacement error. Although the laser interferometer is widely accepted as a tool for measurement of motion accuracy, the set-up procedure is time-consuming because of the strict requirement on alignment between a laser head and optic units. This paper addresses the development of a laser interferometer to measure the micro displacement for a micro machine. The portable laser interferometer which integrates a laser probe and optics, is developed for the convenient measurement. For the experiment, moving mirror set up on the micro stage. The velocity decoding board is also added to calculate doppler shift frequency directly. The output signal is obtained and analyzed by LabView. Finally experiments are found out the relation between micro displacement and output signal.

  • PDF

Measurement of Static and Dynamic Displacement by Image Processing and Study for Prediction Method of Velocity and Acceleration (영상처리를 이용한 정적·동적 변위 계측과 속도·가속도 추산방식 연구)

  • Heo, Seok;Lee, Bum-Ho;Jang, Il-Young
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.2
    • /
    • pp.112-119
    • /
    • 2011
  • This paper is concerned with the measurement of static and dynamic displacement by image processing(IP) and study for prediction method of velocity and acceleration. To measure the displacement visually, the measurement system consists of a telephoto zoom camera, CCD(charge coupled device) image device and a computer. The specific target on the white board is used to calculate the displacement of the structure. The captured image is then converted into a pixel-based data and then analyzed numerically. The limitation of the system depends on the image capturing speed and the pixel-size of image. In this paper, we developed for the displacement measurement using the image processing method. The proposed method enables us to measure the vibration displacement, velocity and acceleration directly without any contact. The current resolution for the displacement measurement can be seen from the results.

Measurement of the hand-transmitted vibration using a miniature 3-axes accelerometer (초소형 3축 가속도계를 이용한 수전달 진동 측정에 관한 연구)

  • 송치문;장한기;김승한;채장범
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.1043-1047
    • /
    • 2003
  • Most of the measurement and the evaluation of hand-transmitted vibration have been performed by using a small size single axis accelerometer between the handle and the hand palm or a three axis accelerometer attached on an adapter outside the hand(indirect measurement). It is most desirable for the correct evaluation of hand-transmitted vibration form the power tool handle to measure the acceleration between the handle surface and the hand palm in the three axis(direct measurement) as recommended in ISO 5349-1. In the study three axes acceleration measurement device was developed of which the thickness was less than 7mm so that it can be placed between the handle and the palm without any inconvenience during the measurement. To verify the performance of the developed device, measured acceleration by the two methods, direct and indirect, were compared in the study.

  • PDF

Development of channel characteristics measurement system for Medium Voltage Power Line Grid (고압전력선 통신 채널 특성 측정 시스템 개발)

  • Lee, Jae-Jo;Lee, Won-Tae;Oh, Hui-Myoung;Kim, Kwan-Ho;Lee, Dae-Young
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2640-2642
    • /
    • 2002
  • In this paper, we show the channel characteristics measurement system the frequency range up to 30MHz for medium voltage Power Line Grid. Power line channel characteristics are investigated by means of various measurement instruments. Measurement system consists of medium voltage coupler, impedance measurement part, noise measurement part, voltage sensing part and communication part. Measured data will be used for PLC channel modeling and PLC network system design.

  • PDF

A Measurement and Analysis of Low Level Radiated-Noise Using Vertical Line Array (수직선배열을 이용한 저소음 함정음향 측정 및 분석기법)

  • Choi, Jae-Yong;Son, Kweon;Dho, Kyeong-Cheol
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.6 no.2
    • /
    • pp.55-64
    • /
    • 2003
  • Underwater acoustic noise measurement is an essential element for vulnerability assessment of modern naval platforms. But during the last few decades environmental conditions have drastically changed due to the gradually increasing sea ambient noise level and decreasing submarine radiated noise level. A real-time underwater acoustic measurement system with vertical line array is designed for the quiet submarine radiated noise assessment in challenging environment. This system has a constant directivity index in measurement frequency range and accurate tracking capability for the transmission loss compensation and navigation aids inside the submarine. This system has been validated at sea and used several times for the submarine noise measurement.

Implementation of a Labview Based Time-Frequency Domain Reflectometry Real Time System for the Load Impedance Measurement (부하 임피던스 측정을 위한 랩뷰기반 시간-주파수 영역 반사파 실시간 시스템 구현)

  • Park, Tae-Geun;Kwak, Ki-Seok;Park, Jin-Bae;Yoon, Tae-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.1803-1804
    • /
    • 2006
  • The purpose of this paper is to implement a Labview based TFDR Real Time system through the instruments of Pci eXtensions for Instrumentation(PXI). The proposed load impedance measurement algorithm was verified by experiments via the implemented real time system. The TFDR real time system consisted of the reference signal design, signal generation, signal acquisition, algorithm execution and results display parts. To implement real time system, all of the parts wore programmed by the Labview which is one of graphical programming languages. In the application software implemented by the Labview we were able to design a suitable reference signal according to the length and frequency attenuation characteristics of the target cable and controled the arbitrary waveform generator(ZT500PXI) of the signal generation part and the digital storage oscilloscope(ZT430PXI) of the signal acquisition part. By using the TFDR real time system with the terminal resistor on the target cable, we applied to the load impedance measurements. In the proposed load impedance algorithm a normalized time-frequency cross correlation function and a cross time-frequency distribution function was employed to calculate the reflection coefficient and phase difference between the input and the reflected signals.

  • PDF

Development of an Acoustic Velocity Profiler by Using Pulse Repetition Frequency Technique (펄스반복주파수 기법을 이용한 초음파 유속 프로파일러 개발)

  • Lee, Chan-Joo;Kim, Dong-Gu;Lee, Jae-Hoon;Kim, Won
    • Journal of Korea Water Resources Association
    • /
    • v.44 no.9
    • /
    • pp.731-740
    • /
    • 2011
  • An acoustic velocity profiler is developed, which is able to be used for open-channel flow measurement. It measures flow velocity based Doppler effect on acoustic signals, which is estimated by using pulse repetition frequency technique. Laboratory and field tests were made to verify velocity measuring performance of the developed device. It is confirmed that the acoustic velocity profiler can normally measure vertical velocity profile in the range above 0.1 m from the bottom and has equivalent performance to commercial acoustic velocity measuring devices.

Corrosion of Quartz Crystal Sensors in Sea Water (항만센서용 수정진동자의 해수에 의한 부식)

  • ;;;A. Egawa;H. Muramatsu
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 1998.10a
    • /
    • pp.183-188
    • /
    • 1998
  • A quartz crystal analyzer is utilized to monitor the cmsion process of an aluminum surface of a quartz crystal by sea water. A quartz crystal having 2000${\AA}$ of aluminum layer is installed in a spedally designed cell and is in contact with an electrolyte solution. While a constant potential is applied to the cell, the resonant frequency and resonant resistance are simultaneously measured using the quartz crystal analyzer. In addition, surface topographs are taken with an atomic force microscope(AFM) and the element analysis of the surface is conducted using an energy dispersive X-ray spectrornetedEDX). The simultaneous measurement of resonant frequency and resonant resistance during the corrosion process explains the change of surface structure caused by the corrosion. The variation of resonant frequency addresses the amount surface metal dissolution. As a conclusion, it is found that a simple measurement using the quartz crystal analyzer can replace the complex monitoring employing large equipments in the investigation of a corrosion process of metal surface.

  • PDF

Analysis of sEMG Median frequency and Ultrasound Image Echodensity of Normal Skeletal Muscle (정상 골격근의 근전도 중앙주파수 및 초음파 영상 밀도 분석)

  • Jeong, Jin-Gyu;Kim, Yong-Nam;Hwang, Tae-Yeun;Lee, Jeong-Woo;Kim, Tae-Youl
    • The Journal of Korean Physical Therapy
    • /
    • v.18 no.1
    • /
    • pp.83-94
    • /
    • 2006
  • Purpose: This study conducts quantitative evaluation or structural and functional characteristics or normal skeletal muscle with ultrasound image and surface electromyography, and is to provide basic materials for utilizing ultrasound image analysis in physical therapy diagnosis and assessment of skeletal muscle. Methods: Measurement of three stages was conducted with 88 normal adults between their twenties and seventies, correlations and differences using collected data according to age and gender were compared and correlations among measured items were analyzed and then the following conclusions were obtained. Results: Analysis of ultrasound image of normal skeletal muscle showed that density, median frequency had the closest relations with age. In addition, it was found that there were high correlations between density explaining structural characteristics of skeletal muscle and median frequency explaining functional characteristics. Conclusion: Analysis of ultrasound image makes complex evaluation of structure and function of skeletal muscle possible when it is connected with functional evaluation method using physical measurement surface electromyography as well as quantitative evaluation of structural changes of skeletal muscle and is effective in complementing physical therapy diagnosis centering around functionality evaluation.

  • PDF

Characteristics of Isolator for material parameter (페라이트 소재변수에 따른 아이솔레이터 특성 연구)

  • Jun, Dong-Suk;Lee, Hong-Yeol;Kim, Dong-Young;Lee, Sang-Seak
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.119-122
    • /
    • 2003
  • This paper describes characteristics for insertion losses of Isolator have an effect on material parameter. One purpose of the paper is to present insertion loss on this resonator for magnetic loss, dielectric loss, magnetic field and saturation magnetization. Another is to study the effect of propeller resonator on response characteristics. In this paper, the analysis and measurement of the response characteristics were carried out for the isolator prototype. The measurement results agreed on the simulation results and acquire insertion loss $0.18\;{\sim}\;0.24dB$, return loss 27dB, isolation 27dB and bandwidth 500MHz on this condition saturation magnetization 550G, dielectric loss 0.0004, magnetic loss 20 and dielectric constant 14.

  • PDF