• Title/Summary/Keyword: frequency measurement

Search Result 4,252, Processing Time 0.03 seconds

Evaluation of manual workload in repetitive wrist and finger motion (반복적인 손목 및 손가락 작업에서의 수작업 부하 평가)

  • Gwon, O-Chae;Yun, Myeong-Hwan
    • Journal of the Ergonomics Society of Korea
    • /
    • v.18 no.2
    • /
    • pp.103-120
    • /
    • 1999
  • The purpose of this study was to evaluate the manual workload in repetitive wrist and finger motion. To evaluate manual workload, angular displacement of the joint, EMG of the muscle and subjective rating were studied. Both wrist motion and finger motion were studied. A screw-driving task was used for the wrist motion experiment. A keyboard typing task was used for the finger motion experiment. All finger joint angles and wrist angles were measured by an angle-measuring glove($CyberGlove^{TM}$, Virtual Technologies, Inc.). Surface EMG was recorded from FCU muscle and FDS muscle simultaneously with the angle measurement. Subjective ratings of exertion were also recorded using the modified Borg's CR-10 scale. Repetition rates of 0.5, 1, 2 motions per second were used with each task. As a result, manual workload increased with increasing repetitiveness. Peak spectral magnitude and frequency components corresponded closely with joint angular displacement amplitudes and repetition rates. Results of the correlation analysis showed that there were significant correlation among EMG, frequency-weighted motion and subjective measurement. Both EMG and frequency-weighted filtering showed consistent workload estimation with increasing task frequency. Subjective ratings showed slight over-estimation of the workload as the task frequency is increased.

  • PDF

Measurement of the Biological Active Point using the Bio-electrical impedance analysis based on the Adaptive Frequency Tracking Filter (적응주파수추적필터기반의 생체임피던스분석을 통한 생물학적활성점측정에 관한 연구)

  • Park, Hodong;Lee, Kyoungjoung;Yeom, Hojun
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.6
    • /
    • pp.109-114
    • /
    • 2013
  • The biological active points (BAP) are known as low resistance spots or good electro-permeable points. In this paper, a new method for BAP detection using the bio-impedance measurement system based on the adaptive frequency tracking filter (AFTF) and the transition event detector is presented. Also, the microcontroller process continuous time demodulation of the modulated signal by multi frequency components using the AFTF. The transition event detector based on the phase space method is applied about each frequency using the BAP equivalent model which is proposed.

A Study on the Bandwidth Frequency of Directional Control Valves based on the Amplitude of the Metering-Orifice Pressure (미터링 오리피스 압력 진폭을 이용한 방향제어밸브 대역폭 주파수에 관한 연구)

  • Kim, Sungdong;Jeon, Sehyeong;Shin, Daeyoung
    • Journal of Drive and Control
    • /
    • v.14 no.2
    • /
    • pp.1-8
    • /
    • 2017
  • The spool displacement of a directional control valve can be considered as the standard signal for the measurement of its bandwidth frequency. When the spool displacement is not available, the metering-orifice system is suggested in this study as an alternative way to measure the - 3 dB amplitude-ratio bandwidth frequency of the hydraulic directional-control valve. The amplitude ratio of the metering-orifice pressure can be adjusted to equal that of the spool displacement through the controlling of the metering-orifice opening area. A series of experiments were conducted to verify the effectiveness of the metering-orifice system. The metering orifice was confirmed as adequate for the measurement of the - 3 dB amplitude-ratio bandwidth frequency.

Vector Network Analysis Using a One-Path, Frequency-Multiplied Photonic Link

  • Lee, Dong-Joon;Kwon, Jae-Yong;Kang, Jin-Seob;Whitaker, John F.
    • Journal of electromagnetic engineering and science
    • /
    • v.10 no.4
    • /
    • pp.282-289
    • /
    • 2010
  • A simplified, practical vector network analyzer (VNA) that uses mature radio-over-fiber technology has been designed and demonstrated. The measurement concept allows the full S-parameters of a microwave device (or antenna) to be obtained while minimizing the detrimental effects of electrical cables, which are replaced with a photonic link. A variety of high-frequency light modulation schemes with frequency sweeping capabilities are presented to realize a one-path (single, forward), frequency-multiplied optical link for VNA applications. Using the photonic one-path link, full two-port S-parameters have been extracted based on five-term error modeling, which has half the error terms compared with the standard duplex configuration. The S-parameters of a microwave filter and antenna measured using frequency-multiplied optical links are found to be in good agreement with those obtained using a conventional VNA.

A Study of Combustion Instability Mode in Dual Swirl Gas Turbine Combustor by PLIF and Chemiluminescence Measurement (PLIF 및 자발광 계측을 이용한 이중선회 가스터빈 연소기에서 연소불안정 모드 연구)

  • Choi, Inchan;Lee, Keeman;Juddoo, Mrinal;Masri, A.R.
    • Journal of the Korean Society of Combustion
    • /
    • v.19 no.1
    • /
    • pp.29-38
    • /
    • 2014
  • This paper described an experimental investigations of combustion instability mode in a lean premixed dual swirl combustor for micro-gasturbine system. When such the instability occurs, a strong coupling between pressure oscillations and unsteady heat release excites a self-sustained acoustic wave which results in a loud, annoyed sound and may also lead a structural damage to the combustion chamber. The detailed period of flame behavior and heat release in combustion instability mode have been examined with high speed OH and CH-PLIF system and $CH^*$ chemiluminescence measurement, flame tomography with operated at 10 kHz and 6 kHz each. Experiment results suggest that unstable flame behavior has a specific frequency with 200 Hz and this frequency is accords with about 1/2 sub-harmonic of combustor resonance frequency, not fundamental frequency. This is very interesting phenomenon that have not reported yet from other previous works. Therefore, when a thermo-acoustic instability with Rayleigh criterion occurs, the fact that the period of heat release and flame behavior are different each other was proposed for the first time through this work.

Application and Analysis of 1D FRI (Finite Rate of Innovation) Super-resolution Technique in FMCW Radar (FMCW 레이더에서의 1D FRI (Finite Rate of Innovation) 초고해상도 기법 적용 및 분석)

  • Yoo, Kyungwoo;Kong, Seung-Hyun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.7
    • /
    • pp.31-39
    • /
    • 2014
  • Recently, as Intelligent Transportation System (ITS) and self-driving system become influential in the ground transportation system, automotive radar systems have been actively studied among the various radar systems to implement the vehicle collision detection system and distance measurement system between vehicles. Most of the automotive radars are Frequency Modulated Continuous Wave (FMCW) radar type which can calculate distance and velocity of target by estimating the frequency difference between the transmitted signal and received signal. Therefore, accurate frequency estimation is very important in the FMCW radar system. For this reason, to improve the measurement accuracy of the FMCW radar, Reverse Directional FRI (RD-FRI) Super-Resolution technique which has high frequency estimation accuracy is applied to the FMCW radar system. The feasibility of the proposed technique is evaluated with simulation results and compared with FFT and conventional Super-Resolution techniques. The simulation results show that the proposed technique estimates the frequency with high accuracy and the distance with centimeter accuracy.

Improvements of Reverberation Chamber's Performance by using Active Noise Control (능동 소음제어를 이용한 잔향실의 저주파 특성 개선 가능성)

  • K. Kim, Young-Key;Oh, Shi-Whan;Moon, Sang-Mu;Im, Jong-Min;Kim, Hong-Bae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.857-861
    • /
    • 2004
  • An active method that improves low frequency characteristics of a reverberation chamber has been proposed. Spatial uniformity of sound pressure at low frequency has been increased by applying active noise control system. The system acts as frequency selective damping materials, which decreases resonance at low frequency and leave high frequency sound field as it is. Linearity of the chamber, which is essential for sound power measurement in the chamber, is guaranteed since fixed control logic has been adopted. Simple application and tests have been done in a small sized rectangular reverberation chamber which has 400Hz cutoff, Loud speakers were used to simulate a noise source and to construct an active noise control system. The spatial distribution of a sound field at 250Hz, 315Hz and 400Hz bands has been measured before and after control. The standard deviation of sound field has been decreased from 3.4dB to 2.5dB. The results show the possibility of active control system as a sound diffuser.

  • PDF

Confinement Effect Analysis Of Suction Pile In Ground Soil On The Basis Of Natural Frequency Measurement (고유진동수 기반 석션기초의 지반구속효과 분석)

  • Ryu, Moo Sung;Lee, Jun Shin;Lee, Jong Hwa;Seo, Yun Ho
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.1
    • /
    • pp.31-36
    • /
    • 2022
  • This paper presents the measuring process of dynamic properties of offshore wind power foundation and provides consideration of each step. This Guideline enables to maintain consistent measuring procedure and therefore increase the reliability of test results. Small scaled suction bucket foundation was fabricated to represent the commercial support structure installation mechanism and two cases(free-free, free-fixed) of dynamic tests were performed at workshop. From the tests, the importance of dynamic properties of connection part between suction bucket and tower was figured out. More over, types and configuration of measuring devices are recommended which can help find the natural frequency of wind turbine foundation correctly. In field test, it was found that the natural frequency of suction bucket foundation was increased linearly with the penetration depth due to the confining effect of ambient soil. Meanwhile, it was not easy to get an enough excitation force with normal impact hammer because the N.F of suction bucket model was in the lower range of 0 Hz ~ 5 Hz. Therefore, new excitation method which has enough force and can excite lower frequency range was devised. This study will help develop safety check procedure of suction bucket foundation in field at each installation stage using the N.F measurement.

Measurement of Multimode Fiber Bandwidth by the Fourth-Order Spectra of Amplified Spontaneous Emission

  • Moon, Sucbei;Kim, Dug Young
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.1
    • /
    • pp.15-22
    • /
    • 2014
  • We present a novel bandwidth measurement scheme for multimode optical fibers. Amplified spontaneous emission (ASE) radiation was utilized for a source of intrinsically modulated light with a wide modulation bandwidth. In our measurement scheme, the continuous-wave (CW) ASE light that passed through a multimode fiber (MMF) under test was analyzed by the fourth-order power with a high-speed photodetector and an electric spectrum analyzer. The modulation transfer function of the multimode fiber could be directly measured with the photoelectric spectra in the modulation frequency domain. The measurement result of our method was experimentally compared to that of the conventional measurement scheme based on the impulse response measurement. It has been found that our scheme provides a stable measurement means of MMF characterization that is suitable for the field testing due to the simplicity of the system.

The Effects of Imprecise Measurement on the Economic Asymmetric $\bar{X}$ and S Control Charts

  • Yang, Su-Fen
    • International Journal of Quality Innovation
    • /
    • v.3 no.2
    • /
    • pp.46-56
    • /
    • 2002
  • The presence of imprecise measurement may seriously affect the efficiency of process control and production cost. A cost model is derived to determine the design parameters of the economic asymmetric $\bar{X}$ and S control charts including measurement errors. The effects of imprecise measurement on the performance of the economic asymmetric $\bar{X}$ and S control charts and production cost are examined for the case where the process mean and process standard deviation may change. Application of the proposed control charts is demonstrated through an example. Numerical examples illustrate the effects of imprecise measurement on the design parameters of the proposed control charts. It shows that the imprecision measurement may seriously affrct the ability of the proposed control charts to detect process disturbances quickly, change the sampling frequency, and increase the production cost compared to the control charts excluding measurement errors.