• 제목/요약/키워드: frequency measurement

검색결과 4,252건 처리시간 0.037초

헤테로다인 변위 측정 간섭계의 고속, 고분해능 위상 측정 (High-speed, High-resolution Phase Measuring Technique for Heterodyne Displacement Measuring Interferometers)

  • 김민석;김승우
    • 한국정밀공학회지
    • /
    • 제19권9호
    • /
    • pp.172-178
    • /
    • 2002
  • One of the ever-increasing demands on the performances of heterodyne interferometers is to improve the measurement resolution, of which current state -of-the-art reaches the region of sub-nanometers. So far, the demand has been met by increasing the clock speed that drives the electronics involved fur the phase measurement of the Doppler shift, but its further advance is being hampered by the technological limit of modem electronics. To cope with the problem, in this investigation, we propose a new scheme of phase -measuring electronics that reduces the measurement resolution without further increase in clock speed. Our scheme adopts a super-heterodyne technique that lowers the original beat frequency to a level of 1 MHz by mixing it with a stable reference signal generated from a special phase- locked-loop. The technique enables us to measure the phase of Doppler shift with a resolution of 1.58 nanometer at a sampling rate of 1 MHz. To avoid the undesirable decrease in the maximum measurable speed caused by the lowered beat frequency, a special form of frequency up-down counting technique is combined with the super-heterodyning. This allows performing required phase unwrapping simply by using programmable digital gates without 2n ambiguities up to the maximum velocity guaranteed by the original beat frequency.

Measurement of Electron Density and Electron-neutral Collision Frequency Using Cutoff Probe Based on the Plasma Reactance Measurement

  • 유광호;김대웅;나병근;서병훈;유신재;김정형;성대진;신용현;장홍영
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.184-184
    • /
    • 2012
  • We proposed a new measurement method of cutoff probe using the reactance spectrum of the plasma in cutoff probe system instead of transmission spectrum. The high accurate reactance spectrum of the plasma which is expected in previous circuit simulation of cutoff probe [1] was measured by using the automatic port extension method of the network analyzer. The measured reactance spectrum is good agreement with E/M wave simulation result (CST Microwave Studio). From the analysis of the measured reactance spectrum based on the circuit modeling, not only the electron density but also electron-neutral collision frequency can be simply obtained. The obtained results of electron density and e-n collision frequency were presented and discussed in wide range of experimental conditions, together with comparison result with previous methods (a previous cutoff probe using transmission spectrum and a single langmuir probe).

  • PDF

Diagnosis of Medium Voltage Cables for Nuclear Power Plant

  • Ha, Che-Wung;Lee, Do Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권4호
    • /
    • pp.1369-1374
    • /
    • 2014
  • Most accidents of medium-voltage cables installed in nuclear power plants result from the initial defect of internal insulators or the initial failure due to poor construction. However, as the service years of plants increase, the possibility of cable accidents is also rapidly increases. This is primarily caused by electric, mechanical, thermal, and radiation stresses. Recently, much attention is paid to the study of cable diagnoses. To date, partial discharge and Tan${\delta}$ measurements are known as reliable methods to diagnose the aging of medium-voltage cables. High frequency partial discharge measurement techniques have been widely used to diagnose cables in transmission and distribution systems. However, the on-line high frequency partial discharge technique has not been used in the nuclear power plants because of the plant shutdown risk, degraded measurement sensitivity, and application problems. In this paper, the partial discharge measurement with a portable device was tried to evaluate the integrity of the 4.16kV and 13.8kV cable lines. The test results show that the high detection sensitivity can be achieved by the high frequency partial discharge technique. The present technique is highly attractive to diagnose medium voltage cables in nuclear power plants.

Microwave Instantaneous Frequency Measurement (IFM) Approach Based on an Integrated Photonic Ti:LiNbO3 Y Branch

  • Zhang, Changsheng;Zhang, Jiahong;Zhao, Zhengang
    • Current Optics and Photonics
    • /
    • 제4권4호
    • /
    • pp.361-367
    • /
    • 2020
  • An approach based on an integrated photonic Ti:LiNbO3 Y branch has been proposed, designed, and analyzed for the microwave instantaneous frequency measurement (IFM). By designing the Y branch with length L = 6545 ㎛ and refractive index NTE - NTM = 0.0764, a complementary optical filter with free spectral range (FSR) of 600 GHz is constituted, which results in a maximum measureable frequency of 300 GHz being obtained. Theoretical analysis on the temperature stability of the Ti:LiNbO3 Y branch shows that the FSR variation of the complementary filter is 0.3% for the temperature change of 100 K, which indicates that the IFM approach will have a better stability. All these results demonstrate that the proposed IFM approach has potential capability to be used for the increasingly higher microwave IFM with better stability.

측정기의 효율적 운영에 관한 실증적 연구

  • 유현종;정수일
    • 건설안전기술
    • /
    • 통권48호
    • /
    • pp.64-74
    • /
    • 2009
  • Measurement is a essential part in all kinds of industry, especially in manufacturing. But until now, measurement hasn't been located to the core of manufacturing in domestic. This improvement guide line for the multilateral problems of measuring instrument investigation of small and medium-sized enterprises. To use measuring treat it must be accustomed with the structure, the performance, the method. must be corrected periodically. The correcting-schedule is established with accuracy, stability, purpose, condition, and frequency.

  • PDF

HVDC 시스템의 주파수 신호검출 위치 변경에 따른 새로운 주파수 제어기 특성 연구 (A Study on the Characteristics of New Frequency Controller According to Changing the Frequency Measurement Position of HVDC System)

  • 김찬기;한병성;박종광
    • 전력전자학회논문지
    • /
    • 제10권5호
    • /
    • pp.457-467
    • /
    • 2005
  • 본 논문은 해남에서 제주로 연결되어 운전중인 HVDC 시스템의 새로운 주파수 제어기에 대하여 연구하였다. 연구의 첫 번째 목적은 현재의 동기조상기를 제거하기 위하여 새로운 주파수 제어기를 개발하고, 평가를 수행하는 것이다. 모의실험 케이스를 만들기 위하여 PSCAD/EMTDC와 PSS/E를 혼합하여 사용하였고 주 시스템 연구는 과도상태 분석을 위하여 PSCAD/EMTDC을 사용하였다. 연구 케이스는 3상과 1상 지락 그리고 부하탈락에 대한 사고를 모의하였고 연구결과를 나타내었다. 결론적으로 AC 네트워크로부터 검출되는 새로운 주파수 측정 방법은 유효한 주파수 제어와 동적 성능을 나타냄을 알 수 있었다.

Fabrication of Hybrid Composite Plates with an Active Frequency Selective Surface

  • Seo, Yun-Seok;Chun, Heoung-Jae;Hong, Ic-Pyo;Park, Young-Bae;Kim, Yoon-Jae
    • Composites Research
    • /
    • 제30권5호
    • /
    • pp.273-279
    • /
    • 2017
  • This paper describes the fabrication techniques and analysis of hybrid composite plates with an active frequency selective surface (FSS). For fabricating hybrid composite plate with active FSS, an active FSS with a resonance frequency located in the C band can obtained using varactor diodes. The hybrid composite plate was first designed and simulated to determine its electromagnetic properties using the commercial software HFSS. After simulation, active FSSs and hybrid composite plates were fabricated by mounting with varactor diodes. After fabrication, free space measurement was used to determine the electromagnetic properties of active FSS and the hybrid composite plates. The simulation and experimental results were in good agreement.

실시간 공정신호를 통한 용접공정 알고리즘에 관한 연구 (A Study on Welding Process Algorithm through Real-time Current Waveform Analysis)

  • 윤진영;이영민;신순철;최해운
    • Journal of Welding and Joining
    • /
    • 제33권4호
    • /
    • pp.24-29
    • /
    • 2015
  • The current waveform was analysed to monitor the weld quality in real time process. The acquired current waveform was discretely analysed for the top and bottom limits of peaks as well as the pulse frequency measurement. Fast Fourier Transform was implemented in the program to monitor the pulse frequency in real time. The developed algorithm or program was tested for the validation purpose. The cross-section of weld profile was compared to the current waveform profile to correlate the monitored signal and the actual parts. Pulse frequency was also used as auxiliary tool for the quality monitoring. Based on the results, it was possible to evaluate the quality of welding by measure the current waveform profile and frequency measurement.

전자기파 부분방전 신호의 권선 투과 특성 (Partial Discharge Electromagnetic Wave Penetration Characteristics Throughout Transformer Winding)

  • 주형준;한기선;윤진열
    • 한국전기전자재료학회논문지
    • /
    • 제23권10호
    • /
    • pp.809-813
    • /
    • 2010
  • Frequency domain measurement of propagation loss for ultra high frequency (UHF) partial discharge in the winding of power transformer using a spectrum analyzer and pulse generator is presented. We compared the performance of the method using a network analyzer with and without a winding. Using a network analyzer simplifies the measurement and offers better dynamic range and frequency range. It also provides precise propagation loss within the winding in frequency domain at UHF range. We applied this method to measure UHF propagation loss of transformer mock-up, modeled 154 kV 20 MVA power in KEPCO substation.

작업부하에 따른 생리적 반응들에 관한 연구 (A Study of Physical Responses for Work Loads)

  • 김재현;김홍기
    • 산업경영시스템학회지
    • /
    • 제25권1호
    • /
    • pp.9-13
    • /
    • 2002
  • The objective of this study was to analyze and make comparison between the physical responses such as oxygen consumption rate, heart rate, and EMG-measurement for lifting tasks. Lifting activities with three different working frequencies(5, 8, 11 lifts/min) and two different weights(10, 20kg) for a lifting range(from floor to 76cm height) were studied. It was found that theme are positive correlations between the oxygen consumption rate and the EMG-measurements on the region of law back. Even though these physical responses were influenced by work weights and work frequency, it was found that the work frequency plays more important role in making muscle fatigue than the work weight. From these finding it is suggested that the work frequency should be considered as a more influencing factor than the work weight as long as the weight belongs to the permissible range based on the viewpoint of the biomechanical criterion for designing a job of manual materials handling tasks.