• Title/Summary/Keyword: frequency domain design

Search Result 607, Processing Time 0.026 seconds

Numerical Analyses on the Aerodynamic Characteristics of an Axial Type In-line Duct Fan (축류식 In-line duct fan의 공력특성에 관한 전산해석)

  • Cho, Lee-Sang;Ahn, Kwang-Weon;Cho, Jin-Soo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.4
    • /
    • pp.1-11
    • /
    • 2004
  • Numerical analyses on the aerodynamic characteristics of a counter rotating axial flow fan were conducted for the development of an axial type in-line duct fan. The counter rotating fan has a front rotor and a rear rotor which are counter rotating each other. Blade design of the counter rotating fan was done by extension of design method for axial flow fan which consists of rotor and stator blades. Through flow analysis was performed using matrix method which is applied for flow fields prediction of compressors or turbines. Aerodynamic characteristics and characteristic curves of the counter rotating fan were analyzed by expansion of the frequency domain panel method with duct modeling. Pressure losses were higher at leading edge and hub region of rotor blades. Characteristic curve of the counter rotating fan was overpredicted without consideration of viscous effect.

Analysis and Design Optimization of Interconnects for High-Speed LVDS Applications (고속 LVDS 응용을 위한 전송선 분석 및 설계 최적화)

  • Ryu, Jee-Youl;Noh, Seok-Ho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.10
    • /
    • pp.70-78
    • /
    • 2009
  • This paper addresses the analysis and the design optimization of differential interconnects for high-speed Low-Voltage Differential Signaling (LVDS) applications. Thanks to the differential transmission and the low voltage swing, LVDS offers high data rates and improved noise immunity with significantly reduced power consumption in data communications, high-resolution display, and flat panel display. We present an improved model and new equations to reduce impedance mismatch and signal degradation in cascaded interconnects using optimization of interconnect design parameters such as trace width, trace height and trace space in differential printed circuit board (FPCB) transmission lines. We have carried out frequency-domain full-wave electromagnetic simulations, and time-domain transient simulations to evaluate the high-frequency characteristics of the differential FPCB interconnects. We believe that the proposed approach is very helpful to optimize high-speed differential FPCB interconnects for LVDS applications.

Analysis and Design Optimization of Interconnects for High-Speed LVDS Applications (고속 LVDS 응용을 위한 전송 접속 경로의 분석 및 설계 최적화)

  • Ryu, Jee-Youl;Noh, Seok-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.761-764
    • /
    • 2007
  • This paper addresses the analysis and the design optimization of differential interconnects for Low-Voltage Differential Signaling (LVDS) applications. Thanks to the differential transmission and the low voltage swing, LVDS offers high data rates and improved noise immunity with significantly reduced power consumption in data communications, high-resolution display, and flat panel display. We present an improved model and new equations to reduce impedance mismatch and signal degradation in cascaded interconnects using optimization of interconnect design parameters such as trace width, trace height and πace space in differential flexible printed circuit board (FPCB) transmission lines. We have carried out frequency-domain full-wave electromagnetic simulations, time-domain transient simulations, and S-parameter simulations to evaluate the high-frequency characteristics of the differential FPCB interconnects.

  • PDF

A Study on the Fault Diagnosis of Roller-Shape Using Frequency-Domain Analysis of Tension Signals (장력신호의 주파수 해석을 이용한 롤 형상 이상 진단에 관한 연구)

  • Sin, Gi-Hyeon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.12
    • /
    • pp.107-114
    • /
    • 2000
  • Rollers and rolls in the continuous process systems are noes of key components that determine the quality of web products. The condition of rollers and rolls(ex. eccentricity wear) should be consistently monitored in order to maintain the process conditions (ex. tension, edge position) within a required specification. In this paper, a new diagnosis technique is suggested to detect the defect of rollers/rolls (ex. eccentricity, wear) based on frequency domain analysis of web tension signal. The kernel of this technique is to use the spectrum amplitude of tension signal which allows to identify the fault rollers/rolls and to also diagnose the degree of fault in corresponding rollers and rolls. The experimental results proved that the suggested diagnosis technique can be successfully used to identify the defect rollers and rolls as well as to diagnose the degree of the defect of those rollers. The suggested technique can be applied to monitor and diagnose the shape of rollers and rolls in various multi-span web transport systems.

  • PDF

Numerical analysis for the development of a Mixed-flow In-line duct fan with a high performance (고성능 사류식 In-line duct fan의 개발을 위한 전산해석)

  • Kim, Sung-Kon;Cho, Lee-Sang;Cho, Jin-Soo;Won, Eu-Pil
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.604-609
    • /
    • 2001
  • This numerical analysis uses the lifting surface method and frequency-domain panel method based on the linear compressible aerodynamic theory. Increased knowledge of flow conditions within mixed-flow fan should indicates means of improving performance of these turbomachines. Thus, only an approximate solution is obtained whose prime intent is to recognize the most significant characteristics of the "ideal" geometry. For a given set of operating condition, the flow conditions within mixed-flow fan depend on the geometry of the machine (three-dimensional flow effects) and on the properties of the fluid. But most treatments of the problem have been concerned with the two-dimensional flow effects for incompressible, non-viscous fluids. Interest in the field of mixed-flow fan resulted in the undertaking of a program to develop reliable design procedures that would avoid the need for lengthy development work.

  • PDF

Performance assessment of bridges using short-period structural health monitoring system: Sungsu bridge case study

  • Kaloop, Mosbeh R.;Elsharawy, Mohamed;Abdelwahed, Basem;Hu, Jong Wan;Kim, Dongwook
    • Smart Structures and Systems
    • /
    • v.26 no.5
    • /
    • pp.667-680
    • /
    • 2020
  • This study aims at reporting a systematic procedure for evaluating the static and dynamic structural performance of steel bridges based on a short-period structural health monitoring measurement. Sungsu bridge located in Korea is considered as a case study presenting the most recent tests carried out to examine the bridge condition. Short-period measurements of Structural Health Monitoring (SHM) system were used during the bridge testing phase. A novel symmetry index is introduced using statistical analyses of deflection and strain measurements. Frequency Domain Decomposition (FDD) is implemented to the strain measurements to estimate the bridge mode shapes and damping ratios. Furthermore, Markov Chain Monte Carlo (MCMC) is also implemented to examine the reliability of bridge performance while ambient design trucks are in static or moving at different speeds. Strain, displacement and acceleration were measured at selected locations on the bridge. The results show that the symmetry index can be an efficient and useful measure in assessing the steel bridge performance. The results from the used method reveal that the performance of the Sungsu bridge is safe under operational conditions.

Wigner-Ville Distribution Applying the Rotating Window and Its Characteristics (회전 창문함수를 적용한 위그너-빌 분포함수와 그 특성)

  • 박연규;김양한
    • Journal of KSNVE
    • /
    • v.7 no.5
    • /
    • pp.747-756
    • /
    • 1997
  • Wigner-Ville distribution which is a time-frequency analysis has a fatal drawback, when the signal has multiple components. This is the cross-talk and often causes a neagative value in the distribution. Wingner-Ville distriution is an expression of power, therefore the cross-talk must be avoided. Smoothing the Wigner-Ville distribution by convoluting it with a window, is most commonly used to reduce the cross-talk. There can be infinite number of distributions depending on the windows. But, the smoothing reduces resolution in time-frequency plane; this motives to design a more effective window in reducing cross-talk while remaining resolution. The domain in which the cross-talk and legitimate components can be easily distinguished, is the ambiguity function. In the ambiguity function domain, the legitimate components appear as linear lines passing through the orgine. But, the cross-talk is widely distributes in the ambiguity function plane. Based on the relative distributions of cross-talk and legitimate components, rotating window can be designed to minimize cross-talk. Applying the rotating window to the ambiguity function corresponds to smoothing the Wigner-Ville distribution. Therefore, the effects of rotating window is estimated in terms of the bias error due to smooting the Wigner-Ville distribution. By applying the rotating window, not only the Wigner-Ville distribution but also its properties are changed. The properties of the new distribution are checked, in order to complete analyzing the rotating window.

  • PDF

A Study on Longline Type Aquaculture Facilities in the Open Sea : Frequency Domain Analysis of Cable-Buoy-Weight Mooring System (내파성 가리비 연승식 양식시설에 관한 연구 - 케이블-부이-중량물 계류시스템의 주파수 영역 해석 -)

  • Shin, H.;Kim, D.S.
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.33 no.4
    • /
    • pp.162-174
    • /
    • 1996
  • Longline type aquaculture facilities in the open sea are based on the cable-buoy-weight mooring system. For their optimal design it is necessary to estimate tensions along the mooring lines including the attachment points of buoys and weights. However, the dynamic analysis is very complicated due to the nonlinear behaviors of the mooring lines and the effects of wave and current. In this paper, parametric studies for various buoy-weight cases are shown. Finite difference scheme is employed in obtaining eigenfrequencies in the frequency domain. Nonlinear hydrodynamic drag forces are equivalently linearized.

  • PDF

The Response to Impulse Signal on Three Phase Transformer using Vector Network Analyzer (벡터 회로망 분석기 측정을 기반으로 한 3상 변압기의 시간영역 펄스 신호에 대한 응답 분석)

  • Kim, Kwangho;Jung, Jongman;Nah, Wansoo
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.1 no.1
    • /
    • pp.79-84
    • /
    • 2015
  • Transformer is widely used element on power system and industrial area. Especially the transformers installed at power system are exposed to an environment of arbitrary changed. Thus the prediction of degradation and the analysis of response to impulse are important. To conduct those works, the electrical characteristics of system should be analyzed, effectively. But the analysis of electrical characteristic in electric machine level such as pole and pad-mounted transformer is almost no, thus commercial VNA (Vector Network Analyzer) is used to getting the response in wide frequency range. However, the output power of VNA is usually under 10mW, so verification for effectiveness of measuring electrically large component should be conducted, firstly. Next, after getting total S-parameter of transformer, predicting impulse response can be performed in time-domain with circuit simulator. In this paper, it is introduced that verification effectiveness of VNA using transfer function from SFRA (Sweep Frequency Response Analyzer), firstly. Next, total S-parameter, six by six matix form, was built using measured 2 port S-parameter from vector network analyzer. To get the response to impulse which is defined by IEC 60060-1, time-domain simulation is conducted to ADS (Advenced Design System) circuit simulator.

A Study on Design and Fabrication of Complex Type EM Wave Absorber with Super Wide-band Characteristics

  • Kim Dae-Hun;Kim Dong-Il;Choi Chang-Mook;Son Jun-Young
    • Journal of Navigation and Port Research
    • /
    • v.30 no.2
    • /
    • pp.161-166
    • /
    • 2006
  • In order to construct an Anechoic Chamber satisfying international standards for EMI testing, it has been recognized that the absorption characteristics of the EM wave absorber must be higher than 20 dB over the frequency band from 30 MHz to 18 GHz. In this paper, an EM wave absorber with super wide-band frequency characteristics was proposed and designed in order to satisfy the above requirements by using the Equivalent Material Constant Method(EMCM) and Finite Difference Time Domain(FDTD). The proposed absorber is to attach a pyramidal absorber onto a hemisphere-type absorber on a cutting cone-shaped ferrite. As a result, the proposed absorber has absorption characteristics higher than 20 dB over the frequency band from 30 MHz to more than 20 GHz.