• Title/Summary/Keyword: frequency control

Search Result 8,950, Processing Time 0.034 seconds

Independent PRF Generation and Control for Frequency Phase Calibration on Mono-pulse Radar at a Remote Location (원격지에서 모노펄스 레이더의 주파수 위상 교정을 위한 독립된 펄스반복주파수 생성 및 제어)

  • Yang, Jaewon;Yoo, Seungoh;Yoon, Jaehyuk;Lee, Dongju
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.24 no.4
    • /
    • pp.368-373
    • /
    • 2021
  • This paper presents a method of independent pulse repetition frequency(PRF) generation and control for frequency phase calibration on mono-pulse radar at a remote location. In order to generate an independent PRF signal of 320[Hz], pulse width modulation(PWM) of 16-bit timer/counter was applied. For a precision control of PRF signal, 16-bit timer/counter interrupt was changed for each period. Therefore, average frequency of PRF could be controlled by 0.0001[Hz]. To calibrate a frequency phase of mono-pulse radar at a remote location, the proposed PRF generator with a precision control of frequency was used regardless of receiving PRF signal from a radar. For the verification of the proposed PRF generator, theoretical analysis and experimental results are included.

Power Control of the DFIG Using the Rotor Exciting Control (회전자 여자제어를 이용한 풍력발전 DFIG의 출력제어)

  • 이우석;오철수
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.3
    • /
    • pp.93-100
    • /
    • 1999
  • Wide operating range and speed control is needed for wind power generating and a Doubly Fed Induction Generator(DFlG) has good adaptivity for that purpose. Ths paper investigates speed and output stator power control using a grid connected to a DFlG in super-synchronous speed regions, by control of both magnitude and frequency of the voltage fed to the rotor. For the speed control analysis, torque simulation is perforrred whereby the different slip between qJernting rmtor driving frequency and synchronous frequency of M-G system awlied. To keep the output rating of the generator, the exciting frequency and voltage attenuation are arolied.rolied.

  • PDF

Performance Enhancement of Pneumatic Vibration Isolator in Low Frequency by Time Delay Control (시간지연 제어기법을 이용한 공압 제진대의 저주파 영역에서의 진동 절연 성능 향상)

  • Oh, Ki-Yong;Shin, Yun-Ho;Lee, Jeung-Hoon;Kim, Kwang-Joon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.11 s.116
    • /
    • pp.1100-1107
    • /
    • 2006
  • As environmental vibration requirements on precision equipment become more stringent, use of pneumatic isolators has become more popular and their performance is subsequently required to be further improved. Performance of passive pneumatic isolators is related to various design parameters in a complicated manner and, hence, is very limited especially in low frequency range by chamber volume. In this study, transmissibility behavior of the pneumatic isolators depending on frequency and dynamic amplitude are presented. Then, an active control technique, time delay control, which is adequate for a low frequency nonlinear system, is applied. A procedure of applying the time delay control law to a pneumatic isolator is presented and it's effectiveness in the transmissibility performance is shown. Comparison between passive and active pneumatic isolators is made based on simulation.

Stand-Alone Wind Energy Conversion System with an Asynchronous Generator

  • Singh, Bhim;Sharma, Shailendra
    • Journal of Power Electronics
    • /
    • v.10 no.5
    • /
    • pp.538-547
    • /
    • 2010
  • This paper deals with a stand-alone wind energy conversion system (WECS) with an isolated asynchronous generator (IAG) and voltage and frequency (VF) control feeding three-phase four-wire loads. The reference generator currents are estimated using the instantaneous symmetrical component theory to control the voltage and frequency of an IAG system. A three-leg voltage source converter (VSC) with an isolated star/delta transformer is used as an integrated VSC. An integrated VSC with a battery energy storage system (BESS) is used to control the active and reactive powers of the WECS. The WECS is modeled and simulated in MATLAB using the Simulink and the Sim Power System (SPS) toolboxes. The proposed VF controller functions as a voltage and frequency regulator, a load leveler, a load balancer and a harmonic eliminator in the WECS. A comparison is made on the rating of the VSC with and without ac capacitors connected at the terminals of an IAG. Simulation and test results are presented to verify the control algorithm.

A Study on the New Control Scheme of Class-I Inverter for IH-Jar Applications with Clamped Voltage Characteristics Using Pulse frequency Modulation (주파수 변조 기법을 이용한 전압 클램프 특성을 갖는 유도가열용 Class-E 인버터의 새로운 제어에 관한 연구)

  • 이동윤;최영덕;현동석
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.3
    • /
    • pp.133-139
    • /
    • 2003
  • In this paper, a new control scheme of Class-E inverter for Induction Heating (IH) Jar applications with clamped voltage characteristics using Pulse-Frequency-Modulation (PFM) is introduced. To reduce the voltage stress of switch, the proposed PFM control scheme doesn't need any auxiliary circuit in comparison to a family of Active Clamped Class-E (ACCE) inverter. It can decrease voltage stress of switch through modulation of switching frequency. The Class-E inverter using the proposed control scheme has the advantage of not only the same output power when it is compared with a Hybrid-Active Clamped Class-E (Hybrid-ACCE) inverter but also Zero-Voltage-Switching (ZVS), which are characteristics of conventional Class-E and ACCE inverter. The control principles and analysis of proposed method are explained in detail and its validity is verified through simulation and experimental results.

Performance Enhancement of Pneumatic Vibration Isolator in Low Frequency by Time Delay Control (시간지연 제어기법을 이용한 공압 제진대의 저주파 영역에서의 진동 절연 성능 향상)

  • Oh, Ki-Yong;Shin, Yun-Ho;Lee, Jeung-Hoon;Kim, Kwang-Joon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.837-843
    • /
    • 2006
  • As environmental vibration requirements on precision equipment become more stringent, use of pneumatic isolators has become more popular and their performance is subsequently required to be further improved. Performance of passive pneumatic isolators is related to various design parameters in a complicated manner and, hence, is very limited especially in low frequency range by chamber volume. In this study, transmissibility behavior of the pneumatic isolators depending on frequency and dynamic amplitude are presented. Then, an active control technique, time delay control, which is adequate for a low frequency nonlinear system, is applied. A procedure of applying the time delay control law to a pneumatic isolator is presented and it's effectiveness in the transmissibility performance is shown. Comparison between passive and active pneumatic isolators is made based on simulation.

  • PDF

Application of FESS Controller for Load Frequency Control

  • Lee, Jeong-Phil;Kim, Han-Guen
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.2 no.3
    • /
    • pp.361-366
    • /
    • 2013
  • This paper presents the effect on application of the flywheel energy storage system (FESS) for load frequency control (LFC) of an interconnected 2 area power system. To do this, the control characteristics with the FESS were compared with that of the conventional governor controller. The controller for the FESS control and the governor control used a PID type controller. Both the FESS PID controller and the governor PID controller using genetic algorithm (GA) were designed to optimize the PID parameters. The frequency and generation output characteristics with the only FESS controller and with the only conventional governor controller were compared. To verify robust performance of the FESS controller, the computer simulations were performed under various disturbances. The simulation results showed that the FESS controller provided better dynamic responses in comparison with the conventional governor controller.

Permanent magnet excitation generator Voltage fluctuation suppression control method (영구자석 여자기형 발전기의 전압변동 억제 제어방식)

  • Jo, YeongJun;Kwak, YunChang;Lee, Dong-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.74-75
    • /
    • 2017
  • This paper proposes a control scheme of the voltage ripple suppression for the permanent magnet exciter generator. The output voltage of the permanent magnet excitation generator is affected by the field current, load current and the engine speed. The engine speed can be controlled by the governor. But, the actual frequency is changed at the starting and a sudden load variation. As a result, output voltage overshoot and undershoot can decrease the power quality in the grid system. The proposed control scheme uses a frequency factor to control the field current of the generator for the voltage ripple reduction. Because of the linkage flux is proportional to the frequency, the instantaneous frequency can consider the linkage flux. The proposed control method shows the improved control performance for the permanent magnet excitation generator through simulation.

  • PDF

Robust Stability eEaluation of Multi-loop Control Systems Based on Experimental Data of Frequency Response

  • Chen, Hong;Okuyama, Yoshifumi;Takemori, Fumiaki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1995.10a
    • /
    • pp.360-363
    • /
    • 1995
  • In this paper, we describe the composition of frequency response bands based on experimental data of plants (controlled systems) with uncertainty and nonlinearity, and the robust stability evaluation of feedback control systems. Analysis and design of control systems using the upper and lower bounds of such experimental data would be effective as a practicable method which is not heavily dependent upon mathematical models such as the transfer function. First, we present a method to composite gain characteristic bands of frequency response of cascade connected plants with uncertainty and a recurrent inequality for the composition. Next, evaluation methods of the robust stability of multi-loop control systems obtained through feedback from the output terminals and multi-loop control systems obtained through feedback into the input terminals are described. In actual control systems, experimental data of frequency responses often depends on the amplitude of input. Therefore, we present the evaluation method of the nominal value and the width of the frequency response band in such a case, and finally give numerical examples based on virtual experimental data.

  • PDF

Hybrid Sensor-less Control of Permanent Magnet Synchronous Motor in Low-speed Region

  • Yamamoto, Yasuhiro;Funato, Hirohito;Ogasawara, Satoshi
    • Journal of Power Electronics
    • /
    • v.8 no.4
    • /
    • pp.301-308
    • /
    • 2008
  • This paper proposes a method of improving the stability in sensor-less control of permanent magnet synchronous motors. The control method for low-speed region is divided into two: One is a high frequency method, which involves a problem of reverse rotation once misdetection of the permanent magnet polarity should occur, and another one is a current drive method, which has a problem that phase and speed oscillations are caused by quick speed changes. Hence, authors propose adoption of the current drive method for the basic control system with added compensation of stabilization by means of the high frequency method. This combination secures stable control with no risk of reversal and less vibration. In addition, authors have also considered a frequency separation filter of a shorter delay time so that current control performance will not lower even when high frequencies are introduced. This filter has achieved simplified compensation using repetitive characteristic through the utilization of the periodicity of high frequency current. Simulation and experiment have been conducted to verify that the stable performance of this system is improved.