• Title/Summary/Keyword: frequency component analysis

Search Result 812, Processing Time 0.032 seconds

Suppression of Cavitation Instabilities in an Inducer by Circumferential Groove and Explanation of Higher Frequency Components

  • Kang, Dong-Hyuk;Arimoto, Yusuke;Yonezawa, Koichi;Horiguchi, Hironori;Kawata, Yutaka;Hah, Chunill;Tsujimoto, Yoshinobu
    • International Journal of Fluid Machinery and Systems
    • /
    • v.3 no.2
    • /
    • pp.137-149
    • /
    • 2010
  • The purpose of the present research is to suppress cavitation instabilities by using a circumferential groove. The circumferential groove was designed based on CFD so that the tip leakage vortex is trapped by the groove and does not interact with the next blade. Experimental results show that the groove can suppress rotating cavitation, asymmetric cavitation and cavitation surge. However, weak instabilities with higher frequency could not be suppressed by the groove. From the analysis of pressure pattern similar to that for rotor-stator interaction, it was found that the higher frequency components are caused by the interaction of backflow vortices with the inducer blades.

Ac Hysteresis Loop Depending on the Phase Angle of the Higher Harmonic Induction

  • derac Son;Eun Kyoung Kim
    • Journal of Magnetics
    • /
    • v.1 no.2
    • /
    • pp.90-93
    • /
    • 1996
  • For the design of high efficiency electric machines, analysis of higher harmonic frequency components of the magnetic induction is necessary. We have measured ac magnetic properties of non-oriented silicon steel under harmonic frequencies ranging from $3^rd$ (180 Hz) to $9^th$(540 Hz) and harmonic amplitude components from 10% to 50% of the total amplitude ($B_max$=1.5T). From the experiment, it is found that, if the magnetic induction waveform has above $9^th$ harmonic frequency components of the magnetic induction, the core losses only depended on the harmonic amplitude component, but if harmonic frequency becomes lower than 9th harmonic frequency, the core losses depend on the phase angle and the harmonic amplitude, and phase angle should be considered in the design of electric machine.

  • PDF

High Frequency Inverter for Induction Heating with Multi-Resonant Zero Current Switching (다중공진 영전류 스위칭을 이용한 고주파 유도가열용 인버터)

  • Ra, B.H.;Suh, K.Y.;Lee, H.W.;Kim, K.T.
    • Proceedings of the KIEE Conference
    • /
    • 2002.06a
    • /
    • pp.38-40
    • /
    • 2002
  • In the case of conventional high frequency inverter, with damage of switch by surge voltage when switch gets into compulsion extinction by load accident and so on because reactor is connected by series to switch, or there was problem of conduction loss by reactor's resistivity component, Also, it has controversial point of that can not ignore conduction loss of switch in complete work kind action of soft switching. In this paper, as high frequency induction heating power supply, we propose half bridge type multi resonance soft switching high frequency inverter topology that can realize high amplitude operation of load current with controlling switch current by multiplex resonance, mitigating surge voltage when switch gets into compulsion extinction and to be complete operation of zero current switching by opposit parallel connected reactor to inverter switch. and do circuit analysis for choice of most suitable circuit parameter of circuit

  • PDF

Analysis of Phase Error Effects Due to Grid Frequency Variation of SRF-PLL Based on APF

  • Seong, Ui-Seok;Hwang, Seon-Hwan
    • Journal of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.18-26
    • /
    • 2016
  • This paper proposes a compensation algorithm for reducing a specific ripple component on synchronous reference frame phase locked loop (SRF-PLL) in grid-tied single-phase inverters. In general, SRF-PLL, which is based on all-pass filter to generate virtual voltage, is widely used to estimate the grid phase angle in a single-phase system. In reality, the estimated grid phase angle might be distorted because the phase difference between actual and virtual voltages is not 90 degrees. That is, the phase error is caused by the difference between cut-off frequency of all-pass filter and grid frequency under grid frequency variation. Therefore, the effects on phase angle and output current attributed to the phase error are mathematically analyzed in this paper. In addition, the proportional resonant (PR) controller is adapted to reduce the effects of phase error. The validity of the proposed algorithm is verified through several simulations and experiments.

Analysis of the Grounding Impedance of a Ground Rod Considering the Frequency-Dependent Resistivity and Relative Permittivity of Soil (토양의 저항률 및 비유전율의 주파수의존성을 고려한 접지봉의 접지임피던스의 해석)

  • Ahn, Chang-Hwan;Choi, Jong-Hyuk;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.1
    • /
    • pp.54-60
    • /
    • 2012
  • When the transient current with high frequency components such as lightning surges are injected the grounding electrodes, the performance of grounding electrodes should be evaluated as grounding impedance. It is restricted to analyze the grounding impedance by measurement approach since the grounding impedance is very different with the shape and size of grounding electrodes, resistivity and relative permittivity of soil and the frequency component of the injected current. So a variety of simulation approaches have been developed. Typically, the soil resistivity measured with low frequency and relative permittivity between 1 and 80 are used for simulation of the grounding impedance. However, the resistivity and relative permittivity of soil are changed with frequency of injected current. In this paper, the frequency-dependent resistivity and relative permittivity of soil are measured and these parameters are reflected in the simulation of the grounding impedance of a ground rod. The simulated results are compared with the measured results. As a result, the simulated results with frequency-dependent soil parameters show capacitive aspect like measured results in the frequency of lower than 100[kHz] and they are more consistent with the measured results in wide frequency range.

Overlapped Subband-Based Independent Vector Analysis

  • Jang, Gil-Jin;Lee, Te-Won
    • The Journal of the Acoustical Society of Korea
    • /
    • v.27 no.1E
    • /
    • pp.30-34
    • /
    • 2008
  • An improvement to the existing blind signal separation (BSS) method has been made in this paper. The proposed method models the inherent signal dependency observed in acoustic object to separate the real-world convolutive sound mixtures. The frequency domain approach requires solving the well known permutation problem, and the problem had been successfully solved by a vector representation of the sources whose multidimensional joint densities have a certain amount of dependency expressed by non-spherical distributions. Especially for speech signals, we observe strong dependencies across neighboring frequency bins and the decrease of those dependencies as the bins become far apart. The non-spherical joint density model proposed in this paper reflects this property of real-world speech signals. Experimental results show the improved performances over the spherical joint density representations.

Vibration Analysis of Large Structures by the Component-Mode Synthesis (부분구조진동형 합성방법에 의한 대형구조계의 진동해석)

  • B.H. Kim;T.Y. Chung;K.C. Kim
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.30 no.3
    • /
    • pp.116-126
    • /
    • 1993
  • The finite element method(FEM) has been commonly used for structural dynamic analysis. However, the direct global application of FEM to large complex structures such as ships and offshore structures requires considerable computational efforts, and remarkably more in structural dynamic optimization problems. Adoption of the component-mode synthesis method is an efficient means to overcome the above difficulty. Among three classes of the component-mode synthesis method, the free-interface mode method is recognized to have the advantages of better computational efficiency and easier implementation of substructures' experimental results, but the disadvantage of lower accuracy in analytical results. In this paper, an advanced method to improve the accuracy in the application of the free-interface mode method for the vibration analysis of large complex structures is presented. In order to compensate the truncation effect of the higher modes of substructures in the synthesis process, both residual inertia and stiffness effects are taken into account and a frequency shifting technique is introduced in the formulation of the residual compliance of substructures. The introduction of the frequency shrift ins not only excludes cumbersome manipulation of singular matrices for semi-definite substructural systems but gives more accurate results around the specified shifting frequency. Numerical examples of typical structural models including a ship-like two dimensional finite element model show that the analysis results based on the presented method are well competitive in accuracy with those obtained by the direst global FEM analysis for the frequencies which are lower than the highest one employed in the synthesis with remarkably higher computational efficiency and that the presented method is more efficient and accurate than the fixed-interface mode method.

  • PDF

Discrimination of Natural Earthquakes and Explosions in Spectral Domain (주파수 영역에서의 인공지진과 자연지진의 식별)

  • 김성균;김명수
    • Economic and Environmental Geology
    • /
    • v.36 no.3
    • /
    • pp.201-212
    • /
    • 2003
  • Recently, the ability of earthquake detection in the Kyungsang Basin of southeastern Korean Peninsula is greatly improved since seismic stations including seismic network of KIGAM(Korea Institute of Geoscience and Mineral Resources) have been significantly increased. However, a large number of signals from explosions are recorded because of frequent medium to large chemical explosions. The discrimination between natural earthquakes and explosions in the Basin has become an important issue. High frequency local records from 43 earthquakes and 43 explosions with comparable magnitude are selected to establish a reliable discrimination technique in the Basin. Several discrimination techniques in spectral domain using spectral amplitude ratios among Pg, Sg, and Lg waves are widely examined with tile selected data. Among them the Pg/Lg spectral ratio method is appeared to be a good discrimination technique to improve the discrimination power. Multivariate discriminant analysis is also applied to the Pg/Lg spectral ratios. The discrimination power of the Pg/Lg ratios for distance corrected three component record compared to uncorrected vertical component one shows distinct improvement. In the frequency band 4 to 14 Hz, Pg/Lg spectral ratio for distance corrected three component record provides discrimination power with a total misclassification probability of only 0.89%.

A Study on the Regionalization of Point Rainfall by Multivariate Analysis Technique (다변량 분석기법에 의한 지점강우의 권역화 연구)

  • Park, Sang-Woo;Jun, Byong-Ho;Jang, Suk-Hwan
    • Journal of Korea Water Resources Association
    • /
    • v.36 no.5
    • /
    • pp.879-892
    • /
    • 2003
  • This study has performed the regionalization of point rainfall which has the hydrological homogeneity for regional frequency analysis of the rainfall. For the study, the recorded rainfall data were collected from 60 rainfall gauge stations distributed all over country of the Korea Meteorological Administration, and 32 rainfall characteristic elements were analyzed from the collected data. Using the principal component analysis to be data reduction technique of the multivariate analysis and the cluster analysis to be grouping technique about many of rainfall characteristic elements of each station, the regionalization of point rainfall was accomplished rationally and efficiently. As the result, hydrological homogeneous regions of point rainfall were divided by 5 regions and 3 other regions, and rainfall characteristics of divided each region were analyzed and compared relatively using regional mean values of each rainfall element data.

Analysis of Decoupling Method in DQ Transform-based for Grid Connected Inverter

  • Windarko, Novie Ayub;Lee, Jin-Mok;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.924-925
    • /
    • 2008
  • There are many types of grid-connected inverter controllers, PI controller based is the most popular methods. But, a common PI control is produced zero-steady state error and phase delay in sinusoidal reference. Synchronous reference frame or DQ transform based controller is capable for reducing both of zero-steady state error and phase delay is. But DQ transform based controller has cross-coupling component which difficult to analyze the system in single phase model. In this paper, to obtained single phase model of the system, DQ transform based controller is analyzed in two techniques. The first is by neglecting cross-coupling. The second is eliminated cross-coupling component by decoupling method. By these two techniques, single phase model is obtained. Then, the single phase model is analyzed to evaluate its performance in stability and frequency response, through Root Locus and Bode diagram, respectively. MATLAB and PSIM simulation is used to verify the analysis. Simulation result is shown; cross-coupling component has no significant influent to the controller.

  • PDF