• 제목/요약/키워드: freezing-thaw test

검색결과 61건 처리시간 0.03초

ALC 의 내구성 및 물성개선에 관한 연구

  • 이범재;홍성수;황의환;조헌영;노재성
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1993년도 가을 학술발표회 논문집
    • /
    • pp.65-70
    • /
    • 1993
  • The effect of particle size of Al powder, water repellent agent and finishing agent on frost resistance, absorption ratio and structure of micropore was examined to improve the physical properties and durability of ALC. According as the amount added of water repellent agent was increased, frost resistance was improved and absorption ratio was decreased. From one side freezing /thaw test, finishing agent which has a low vapor permeation located the crack at close indoor point of ALC specimen. ALC produced from fine Al powder has a low volume reduction by scalling and a sound appearance after freezing/thawing test and top surface freezing test, The crystal of tobermorite in ALC matrix was converted to calcium carbonate by carbonation which was accelerated with the decreasing of water content. Since the micropore of ALC was filled up by calcium carbonate, void ratio was reduced and crack was detected after complete carbonation.

  • PDF

A Numerical Model for the Freeze-Thaw Damages in Concrete Structures

  • Cho Tae-Jun
    • 콘크리트학회논문집
    • /
    • 제17권5호
    • /
    • pp.857-868
    • /
    • 2005
  • This paper deals with the accumulated damage in concrete structures due to the cyclic freeze-thaw as an environmental load. The cyclic ice body nucleation and growth processes in porous systems are affected by the thermo-physical and mass transport properties, and gradients of temperature and chemical potentials. Furthermore, the diffusivity of deicing chemicals shows significantly higher value under cyclic freeze-thaw conditions. Consequently, the disintegration of concrete structures is aggravated at marine environments, higher altitudes, and northern areas. However, the properties of cyclic freeze-thaw with crack growth and diffusion of chloride ion effects are hard to be identified in tests, and there has been no analytic model for the combined degradations. The main objective is to determine the driving force and evaluate the reduced strength and stiffness by freeze-thaw. For the development of computational model of those coupled deterioration, micro-pore structure characterization, pore pressure based on the thermodynamic equilibrium, time and temperature dependent super-cooling with or without deicing salts, nonlinear-fracture constitutive relation for the evaluation of internal damage, and the effect of entrained air pores (EA) has been modeled numerically. As a result, the amount of ice volume with temperature dependent surface tensions, freezing pressure and resulting deformations, and cycle and temperature dependent pore volume has been calculated and compared with available test results. The developed computational program can be combined with DuCOM, which can calculate the early aged strength, heat of hydration, micro-pore volume, shrinkage, transportation of free water in concrete. Therefore, the developed model can be applied to evaluate those various practical degradation cases as well.

Effect of Fiber Hybridization on Durability Related Properties of Ultra-High Performance Concrete

  • Smarzewski, Piotr;Barnat-Hunek, Danuta
    • International Journal of Concrete Structures and Materials
    • /
    • 제11권2호
    • /
    • pp.315-325
    • /
    • 2017
  • The purpose of the paper is to determine the influence of two widely used steel fibers and polypropylene fibers on the sulphate crystallization resistance, freeze-thaw resistance and surface wettability of ultra-high performance concrete (UHPC). Tests were carried out on cubes and cylinders of plain UHPC and fiber reinforced UHPC with varying contents ranging from 0.25 to 1% steel fibers and/or polypropylene fibers. Extensive data from the salt resistance test, frost resistance test, dynamic modulus of elasticity test before and after freezing-thawing, as well as the contact angle test were recorded and analyzed. Fiber hybridization relatively increased the resistance to salt crystallization and freeze-thaw resistance of UHPC in comparison with a single type of fiber in UHPC at the same fiber volume fraction. The experimental results indicate that hybrid fibers can significantly improve the adhesion properties and reduce the wettability of the UHPC surface.

비중의 변화와 발수제 첨가가 경량기포콘크리트의 물성에 미치는 영향 (Effect of the Variation of Speccfic Gravity and the Addition of Water Repellent Agent on the Physical Properties of Autoclaved Lightweight Concrete)

  • 노재성;황의환;홍성수;이범재
    • 콘크리트학회지
    • /
    • 제9권2호
    • /
    • pp.137-144
    • /
    • 1997
  • 발수제의 유무와 알루미늄분말의 분말도 및 첨가량을 조절하여 비중을 0.4에서 0.7로 변화시켜 비중과 ALC의 기초물성, 내동해성 및 내구성과의 관계를 조사하였다. 압축 및 인장강도는 비중이 0.4에서 0.7로 증가함에 따라 발수제의 첨가량에 관계없이 증가하였고 발수제의 첨가량이 증가하면 내동해성은 개선되었으며 흡수율은 감소하였다. 입경이 작은 AI분말을 이용항 제조한 ALC의 박리에 의한 체적감소율은 낮게 나타났으며 일면동결지속시험 및 기중동결수중융해시험에서도 내동해성이 우수한 것으로 나타났다.

제설제 종류에 따른 제설성능 평가 (Deicing Performance with Deicer Types)

  • 이병덕;이찬영;윤병성;이주광;정영환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.371-374
    • /
    • 2005
  • In this study, calcium chloride($CaCl_2$), sodium chloride (NaCl), organic acids-containing deicer(NS 40, NS 100), mixed deicier($NaCl\;70\%\;+\;CaCl_{2}\;30\%,\;NS\;40\;70\%\;+\;CaCl_{2}\;30\%,\;NaCl\;70\%\;+\;NS\;40\;30\%,\;NS\;40\;70\%\;+\;NaCl\;30\%$) is investigated based on the laboratory test for deicing performance. Test items for deicing performance were ice melting and ice penetration, freezing point depressions and eutectic points, pH, thermal properties for selected deicing chemicals. As a test results, in case of the use chloride-containing deicier in area that concrete structures has subjected to freez-thaw reaction in winter season, it showed desirable method that use deicing chemicals mixed with optimum ratio rather than use one deicing chemicals when is consider to deicing performance and effects, corrosion of steel materials, freez-thaw resistance of concrete. When use various deicing chemicals mixed, NS40($70\%$)+Calcium chloride($30\%$) showed the best effective method.

  • PDF

고강도콘크리트의 동결융해저항에 미치는 기포조직의 영향 (Effect of Air Void System of High Strength Concrete on Freezing and Thawing Resistance)

  • 김생빈
    • 콘크리트학회지
    • /
    • 제4권1호
    • /
    • pp.89-96
    • /
    • 1992
  • 콘크리트의 내동해성은 일반적으로 공기량이나 기포조직 및 분포에 따라 크게 영향을 받으며 콘크리트의 강도와도 관련이 있는 것으로 알려져 있다. 본 연구에서는 고강도콘크리트의 동결융해 저항성에 미치는 공기량 및 기포조직 특히 간격계수의 영향에 관한 실험적 연구로서 우선 압축강도는 Non-AE콘크리트를 대상으로 400-500kg/$\textrm{cm}^2$를 목표로 하였고, 실험결과 내구성지수가 10~20%정도에 불과하므로 다음단계로 공기량 2~12%인 AE콘크리트로 하여 내구성 향상을 도모하였다. 이 때 단위시멘트량, 물\ulcorner시멘트비등을 변화시킨 20종류의 콘크리트 배합에 대해 500cycle까지 동결융해시험을 실시하였다. 결론적으로 동결융해의 저항성은 물\ulcorner시멘트비 보다는 공기량과 더 밀접한 관계가 있었고 임계내구성지수에 대응하는 간격계수는 물\ulcorner시멘트비에 따라 다르다는 사실을 알 수 있었다.

Improvement of rooster semen freezability and fertility rate after sericin supplementation in freezing semen extender

  • Ruthaiporn Ratchamak;Supakorn Authaida;Wuttigrai Boonkum;Vibuntita Chankitisakul
    • Animal Bioscience
    • /
    • 제36권10호
    • /
    • pp.1530-1535
    • /
    • 2023
  • Objective: Semen cryopreservation result in decreased sperm parameters and fertilization ability. Sericin exhibits antioxidant activity by reducing lipid peroxidation resulting from free radicals, which can potentially improve cryopreservation outcomes. The present study aimed to examine the efficacy of various sericin concentrations supplemented with a rooster semen-freezing extender on post-thaw semen quality and fertilizing ability of sperm after cryopreservation. Methods: Semen samples were collected from 40 roosters (5 reps), then were pooled, and divided into four groups by the levels of sericin supplementation (0%, 0.25%, 0.50%, and 0.75%) in a freezing extender. Semen suspensions were loaded in medium straw (0.5 mL) and cryopreserved with the traditional liquid nitrogen vapor method. Post-thawed semen was evaluated for sperm motility, sperm viability, and lipid peroxidation. Also, the fertility test was determined. Results: The results showed that supplementation of the freezing extender with 0.50% to 0.75% sericin resulted in greater total motility and progressive motility and lower malondialdehyde levels than the other groups after cryopreservation (p<0.05). However, the viability of 0.75% decreased compared with the value of 0.50% sericin supplementation (p<0.05). Moreover, the fertility and hatchability of total eggs were significantly higher in the 0.50% sericin group than in the other groups (p<0.05). Conclusion: In conclusion, 0.50% sericin is recommended as an alternative component of the freezing extender to improve cryopreserved rooster semen.

Performance of cement-stabilized sand subjected to freeze-thaw cycles

  • Jumassultan, Assel;Sagidullina, Nazerke;Kim, Jong;Ku, Taeseo;Moon, Sung-Woo
    • Geomechanics and Engineering
    • /
    • 제25권1호
    • /
    • pp.41-48
    • /
    • 2021
  • In cold regions, the integrity of the infrastructures built on weak soils can be extensively damaged by weathering actions due to the cyclic freezing and thawing. This damage can be mitigated by exploiting soil stabilization techniques. Generally, ordinary Portland cement (OPC) is the most commonly used binding material for investigating the chemo-hydromechanical behavior. However, due to the environmental issue of OPC producing a significant amount of carbon dioxide emission, calcium sulfoaluminate (CSA) cement can be used as one of the eco-sustainable alternatives. Although recently several studies have examined the strength development of CSA treated sand, no research has been concerned about CSA cement-stabilized sand affected by cyclic freeze and thaw. This study aims to conduct a comprehensive laboratory work to assess the effect of the cyclic freeze-thaw action on strength and durability of CSA cement-treated sand. For this purpose, unconfined compressive strength (UCS) and ultrasonic pulse velocity (UPV) tests were performed on the stabilized soil specimens cured for 7 and 14 days which are subjected to 0, 1, 3, 5, and 7 freeze-thaw cycles. The test results show that the strength and durability index of the samples decrease with the increase of the freeze-thaw cycles. The loss of the strength and durability considerably decreases for all soil samples subjected to the freeze-thaw cycles. Overall, the use of CSA as a stabilizer for sandy soils would be an eco-friendly option to achieve sufficient strength and durability against the freeze-thaw action in cold regions.

실링 테이프 적용에 따른 시공조인트 균열 저항성 평가 (Evaluation of Crack Resistance of Cold Joint as Usage of Sealing Tape)

  • 이재준;이선행;김두병;이진욱
    • 한국도로학회논문집
    • /
    • 제20권3호
    • /
    • pp.1-9
    • /
    • 2018
  • PURPOSES : In order to evaluate a crack resistance at cold joint, sealing tape was adopted to apply at cold joint instead of typical tack coat material(RSC-4). The sealing tape was made by hot sealing material. The crack resistance as function of environmental and traffic loading was measured with visual observation. METHODS : In this study, the crack resistance was evaluated as function of environmental and traffic loading. The freeze-thaw method was adopted for environmental loading of asphalt pavement. condition. The damage of cold joint under freeze-thaw action is initiated by ice expansion load and accelerated by the interfacial damage between new and old asphalt pavement. The traffic loading was applied with wheel tracking machine on the cold joint area of the asphalt pavement for 3 hours at $25^{\circ}C$. The evaluation of crack resistance was measured with visual observation. The freeze-thaw results shows that the sealing tape was significantly increased the crack resistance based on. RESULTS : To estimate the crack resistance at cold joint area due to the environmental loading, the Freeze-thaw test was conducted by exposing the product to freezing temperature(approximately $-18^{\circ}C$) for 24 hours, and then allowing it to thaw at $60^{\circ}C$ for 24 hours. The tack coat material(RSC-4) was debonded after 21 cycles of the Freeze-thaw test. The first crack was observed after 14 freeze-thaw cycle with RSC-4 material. But, the sealing tape was not debonded after 24 cycle test. Also, the sealing tape shows the better performance of the crack resistance under the traffic loading with wheel track test. The crack was generated the under traffic loading with RSC-4(tack coating), however, the crack was not shown with sealing tape. It indicates that the sealing tape has a strong resistance of tensile stress due to traffic loading. CONCLUSIONS :Based on limited laboratory test result, a performance of crack resistance using the sealing tape is better than that of general tack coat material(RSC-4). It means that the sealing tape is possible to extend a pavement service life because the crack, one of the main pavement distresses, will be delayed.

The effect of acid environment and thawing and freezing cycles on the mechanical behavior of fiber-reinforced concrete

  • A.R. Rahimi Chakdel;S.M. Mirhosseini;A.H. Joshagani;M.R.M. Aliha
    • Structural Engineering and Mechanics
    • /
    • 제90권5호
    • /
    • pp.481-492
    • /
    • 2024
  • This research examined the mechanical behavior of fiber-reinforced concrete at unstable environmental conditions. Concrete composites with varying percentages of steel and glass fibers were analyzed. Compressive, indirect tensile, and fracture toughness properties were evaluated using the Edge Notched Disc Bend (ENDB) test under freezing-thawing and acidic environments and the results were compared with normal conditions. Steel fibers decreased the strength in the specified cycles, while glass fibers showed a normal strength trend. The compressive, tensile and fracture toughness of the samples containing 1.5 vol.% fibers showed a 1.28-, 2.13- and 4.5-fold enhancement compared to samples without fibers, after 300 freezing-thawing cycles, respectively.