• Title/Summary/Keyword: freeT_3\

Search Result 1,624, Processing Time 0.026 seconds

농업용수의 수온 상승에 관한 연구

  • 황은;김철규;이상범
    • 물과 미래
    • /
    • 제5권2호
    • /
    • pp.17-29
    • /
    • 1972
  • The persent study aims at finding out a means of prevention cool spell damages on the hilly areas. The irrigation plots of 24 hour stored water warm water way and warm water plots, cool water way are respectively established to find out water temperature and influnce on the growing rice plants. The results obtained are summed up as follows. 1. Warm water areas consisted of $5 m^2 Q=0.93 1{\ell}/sec$, V=31 cm/sec, S=1/1, 000, L=81.6m, B=5cm, h=6cm, t=4min 33sec, drops=9 areas, are constructed to help the water temperature of $14.5^{\circ}C$ rise to that of $21.6^{\circ}C$. This indicates lower temperature than $23^{\circ}C$ of critical water temperature in irrigation facilities by $1.45^{\circ}C$ and than $26.2^{\circ}C$ of balanced water temperature of Seoul arears by $4.6^{\circ}C$. But this does not give much influance on rice plant cultivation. 2. The rising of water temperature is influened according to the temperature, solar radiation but the water temperature changes according to the heat absorption of organized materials, weather and terraces. The difference of water temperature could be found in the first growing stage. 3. Through the warm water way of water rises to the temperature of $21.6^{\circ}C$ which also rises to the temperature of around $30^{\circ}C$ in the paddy field of submerged irrigation. The rice plants are comparatively free from prolonged cool damage, reproduction abstructive damage. 4. The water temperature in rice field in proportion to temperature influence of weather condition but the water temperature approaches to that of weather in the days of later growing stage and water temperature become lower than the air temperature in the fruit stage. 5. The water in the submreged field is $10^{\circ}C$ warmer than in the warm water way during the first growing stage period but the water temperature in the warm water way is warmer in the later growing stage period. The cool water of $14.5^{\circ}C$ is warmed to $30.1^{\circ}C$ and rice plants cultivation is free from other damages. 6. The 12% increased production or 570.98kg/10a is made cool water plot by rising the temperature of water from $14.5^{\circ}C$ to $21.6^{\circ}C$ making the water run through warm water way. 7. The damage inflicted by the cool water irrigation during the first growing stage period is the obstruction of peak tillering stage and the obstruction of heading the later growing stage period and the obstruction of fruiting and number of panides per fill.

  • PDF

L-카르니틴 섭취와 복합운동이 비만여고생의 신체조성, 혈중지질 및 아디포넥틴에 미치는 영향 (Combined Effects of L-Carnitine Supplementation and Exercise on the Body Composition, Serum Lipids and Adiponectin in the High School Obese Female Students)

  • 신원배;서대윤;백영호
    • 생명과학회지
    • /
    • 제20권1호
    • /
    • pp.33-39
    • /
    • 2010
  • 본 연구는 10주간 주 3회, 1회 운동시간 50분을 한 결과, 비만여고생을 대상으로 L-카르니틴 섭취와 복합운동이 신체조성, 혈중지질 및 아디포넥틴에 미치는 영향을 구명하기 위하여 체지방률 35% 이상 비만여고생을 대상으로 실험하였다. 신체조성에서는 운동과 카르니틴 섭취를 병행한 군에서 체중, 체지방량 및 체지방률이 유의하게 감소하였고, 제지방량이 유의하게 증가하였다. 혈중지질변화에서는 T-C는 대조군에서 집단 내 변화를 보였으며, TG는 복합운동과 카르니틴섭취를 병행한 군에서 유의하게 감소하였다. 아디포넥틴의 변화에서는 복합운동과 카르니틴섭취를 병행한 군이 유의하게 증가하였다. 이러한 연구결과를 토대로 보다 효과적인 운동프로그램과 적절한 식이요법으로 비만을 개선하는데 효과가 있을 것으로 사료된다.

부분구조진동형 합성방법에 의한 대형구조계의 진동해석 (Vibration Analysis of Large Structures by the Component-Mode Synthesis)

  • 김병현;정태영;김극천
    • 대한조선학회논문집
    • /
    • 제30권3호
    • /
    • pp.116-126
    • /
    • 1993
  • 대형구조계의 진동해석에 효율적인 방법으로 알려진 부분구조 진동형 합성방법을 방법론적 관점에서 분류하면 부분구조계간의 연결부 경계조건을 어떻게 가정하는가에 따라 구속모드방법, 불구속 모드방법 및 혼합방법으로 대별할 수 있다. 이 방법들 중에서 불구속 모드방법이 보다 효율적이고 또 특정 부분구조의 실험결과 이용이 용이한 장점이 있으나 정확도가 떨어진다는 단점이 있다. 본 연구에서는 대형 구조계의 진동해석에 효율적이면서 정확도 높은 결과를 얻을 수 있는 불구속 모드방법을 정식화하였다. 불구속 모드방법의 정확도 향상 방안으로서 모드합성시 배제된 고차진동형의 영향을 잉여강성과 더불어 잉여관성 효과도 고려하여 보상하였고, 또 주파수이동기법을 도입하므로써 주관심 주파수 부근에서 더욱 정확도가 높은 결과를 얻을 수 있도록 함과 동시에 부분구조계가 semi-definite system일 경우 특이매트릭스를 처리해야 하는 문제점도 해결하였다. 상기방법의 정확도 및 계산효율성은 선체 2차원 단순화 모델을 포함한 일련의 유한요소모델에 대해 검증되었다. 상기방법에 의한 계산결과는 정확도에 있어서 진동형 합성에 이용된 부분구조계의 최고차 진동수 이하에서는 전체계를 직접 유한요소해석한 경우와 대등하고, 구속모드방법보다 효율적이면서 정확도가 더 높은 결과를 얻을 수 있음이 확인되었다.

  • PDF

Effect of keratinase on ileal amino acid digestibility in five feedstuffs fed to growing pigs

  • Huang, Chengfei;Ma, Dongli;Zang, Jianjun;Zhang, Bo;Sun, Brian;Liu, Ling;Zhang, Shuai
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제31권12호
    • /
    • pp.1946-1955
    • /
    • 2018
  • Objective: This study was conducted to evaluate the effect of keratinase (KE) on the apparent ileal digestibility (AID) and standardized ileal digestibility (SID) of amino acids (AA) in rice bran, cottonseed meal (CSM), rapeseed meal (RSM), corn distillers dried grains with solubles (DDGS), and peanut meal (PNM). Methods: Twelve crossbred barrows (Duroc${\times}$Landrace${\times}$Yorkshire, $50.5{\pm}1.4kg$ body weight [BW]) fitted with T-cannulas at the terminal ileum were allotted to a $12{\times}6$ Youden Square design with 12 diets and 6 periods. The treatment diets included rice bran, CSM, RSM, corn DDGS, PNM, or corn-soybean meal (cSBM) supplemented with 0.05% KE or not. Diets were given to pigs at a level of 3% BW in two equal meals. The endogenous AA losses were the mean results of three previously experiments determined by a same nitrogen-free diet fed to pigs. Pigs had free access to water during the experiment. Results: The KE supplementation improved (p<0.05) the AID and SID of Met, Thr, Val, Asp, Cys, and Tyr in rice bran. Inclusion of KE increased (p<0.05) the AID and SID of Met and Val in CSM. The KE supplementation decreased (p<0.05) the AID and SID of His in RSM and all measured AA except for Arg, Met, Trp, Val, Gly, and Pro in corn DDGS. There was an increase (p<0.05) in AID and SID of Leu, Ile, Met, Ala, Cys, Ser, and Tyr in PNM supplemented with KE compared with that without KE. Inclusion of KE increased (p<0.05) the AID and SID of crude protein, Leu, Ile, Phe, Thr, Asp, and Ser in cSBM. Conclusion: This study indicated that KE had different effects on ileal AA digestibility of feedstuffs for growing pigs, which can give some usage directions of KE in swine feed containing those detected feedstuffs.

원주 분극 압전 링 트랜스듀서 해석을 위한 방사 분극 링 유효 물성 도출 (Effective material properties of radially poled piezoelectric ring transducer for analysis of tangentially poled piezoelectric ring)

  • 이학수;조치영;박성철;조요한;이정민
    • 한국음향학회지
    • /
    • 제38권2호
    • /
    • pp.184-192
    • /
    • 2019
  • 33-모드 링은 31-모드 링에 비하여 결합상수와 압전상수 d가 높기 때문에 광대역 수중 음향 트랜스듀서로 활용성이 높다. 반면 31-모드 링은 축대칭 구조이므로 수치해석 수행시 2차원 축대칭 모델로 간략히 해석이 가능하지만, 33-모드 링은 3차원 수치해석을 수행해야 한다. 즉, 특성 예측을 위해 많은 전산자원과 계산시간이 소요된다. 따라서 33-모드 링의 전기-기계-음향 응답을 모사할 수 있는 등가의 31-모드 링의 유효 물성을 도출할 수 있다면 소나 트랜스듀서 설계 등에 실용적일 것이다. 본 연구에서는 응답 특성을 모사하기 위해 각 링의 전기, 기계 임피던스 및 변환계수(${\phi}$)가 동일하다고 가정하여 등가 31-모드 링의 유효 밀도(${\rho}_{31_{-}eff}$), 컴플라이언스($s^E_{11_{-}eff}$), 압전 상수($d_{31_{-}eff}$), 유전 상수(${\varepsilon}^T_{33_{-}eff}$)를 유도했다. 도출한 유효 물성을 이용하여 진공상태의 링, 수중에서 공기 배킹의 링, 그리고 수중에서 링 내부에 자유롭게 유체가 드나드는 링에 대하여 수치해석을 하였고 이를 33-모드 링의 응답특성과 비교하였다.

Oncological and functional outcomes following robot-assisted laparoscopic radical prostatectomy at a single institution: a minimum 5-year follow-up

  • Kang, Jun-Koo;Chung, Jae-Wook;Chun, So Young;Ha, Yun-Sok;Choi, Seock Hwan;Lee, Jun Nyung;Kim, Bum Soo;Yoon, Ghil Suk;Kim, Hyun Tae;Kim, Tae-Hwan;Kwon, Tae Gyun
    • Journal of Yeungnam Medical Science
    • /
    • 제35권2호
    • /
    • pp.171-178
    • /
    • 2018
  • Background: To evaluate mid-term oncological and functional outcomes in patients with prostate cancer treated by robot-assisted laparoscopic radical prostatectomy (RALP) at our institution. Methods: We retrospectively reviewed the medical records of 128 patients with prostate cancer who underwent RALP at our institution between February 2008 and April 2010. All patients enrolled in this study were followed up for at least 5 years. We analyzed biochemical recurrence (BCR)-free survival using a Kaplan-Meier survival curve analysis and predictive factors for BCR using multivariate Cox regression analysis. Continence recovery rate, defined as no use of urinary pads, was also evaluated. Results: Based on the D'Amico risk classification, there were 30 low-risk patients (23.4%), 47 intermediaterisk patients (38.8%), and 51 high-risk patients (39.8%), preoperatively. Based on pathological findings, 50.0% of patients (64/128) showed non-organ confined disease (${\geq}T3a$) and 26.6% (34/128) had high grade disease (Gleason score ${\geq}8$). During a median follow-up period of 71 months (range, 66-78 months), the frequency of BCR was 33.6% (43/128) and the median BCR-free survival was 65.9 (0.4-88.0) months. Multivariate Cox regression analysis revealed that high grade disease (Gleason score ${\geq}8$) was an independent predictor for BCR (hazard ratio=4.180, 95% confidence interval=1.02-17.12, p=0.047). In addition, a majority of patients remained continent following the RALP procedure, without the need for additional intervention for post-prostatectomy incontinence. Conclusion: Our study demonstrated acceptable outcomes following an initial RALP procedure, despite 50% of the patients investigated demonstrating high-risk features associated with non-organ confined disease.

Alternative Immunossays

  • Barnard, G.J.R.;Kim, J.B.;Collins, W.P.
    • 한국가축번식학회지
    • /
    • 제9권2호
    • /
    • pp.133-139
    • /
    • 1985
  • An immunoassay may be defined as an analytical procedure involving the competitive reaction between a limiting concentration of specific antibody and two populations of antigen, one of which is labelled or immobillized. The advent of immunoassay has revolutionised our knowledge of reproductive physiology and the practice of veterinary and clinical medicine. Radioimmunoassay (RIA) was the first of these methods to be developed, which meausred the analyte with good sensitivity, accuracy and precision (1,2). The essential components of RIA are:-(i) a limited concentration of antibodies, (ii) a reference preparation, and (iii) an antigen labelled with a radioisotope (usually tritium or iodine-125). Most procedures invelove isolating the antibody-bound fraction and measuring the amount of labelled antigen. Good facilities are available for scintilltion counting, data reduction nd statistical analysis. RIA is undergoing refinement through:-(i) the introduction of new techniques to separate the antibody-bound and free fractions which minimize the misclassification of labelled antigen into these compartments, and the amount of non-specfic binding. (3), (ii) the development of non-extration for the measurement of haptens (4), (iii) the determination of a, pp.rent free (i.e. non-protein bound) analytes (5), and (iv) the use of monoclonal antibodies(6). In 1968, Miles and Hales introduced in important new type of immunoassay which they termed immunora-diometric assay (IRMA) based on t도 use of isotopically labelled specific antibodies(7) in a move from limited to excess reagent systems. The concept of two-site IRMAs (with a capture antibody on a solid-phase, and a second labelled antibody to a different antigenic determinant of the analyte) has enabled the development of more sensitive and less-time consuming methods for the measurement of protein hormones ovar wide concentration of analyte (8). The increasing use of isotopic methos for diverse a, pp.ications has exposed several problems. For example, the radioactive half-life and radiolysis of the labelled reagent limits assay sensitivity and imposes a time limit on the usefulness of a kit. In addition, the potential health hazards associated with the use and disposal of radioactive cmpounds and the solvents and photofluors necessary for liquid scientillation counting are incompatable with the development of extra-laboratory tests. To date, the most practical alternative labels to radioisotopes, for the measurement of analytes in a concentration > 1 ng/ml, are erythrocytes, polystyrene particiles, gold sols, dyes and enzymes or cofactors with a visual or colorimetric end-point(9). Increased sensitivity to<1 pg/ml may be obtained with fluorescent and chemiluminescent labels, or enzymes with a fluorometric, chemiluminometric or bioluminometric end-point. The sensitivity of any immunoassay or immunometric assay depends on the affinity of the antibody-antigen reaction, the specific activity of the label, the precision with which the reagents are manipulated and the nonspecific background signal (10). The sensitivity of a limited reagent system for the measurement of haptens or proteins is mainly dependent upon the affinity of the antibodies and the smalleest amount of reagent that may be manipulated. Consequently, it is difficult in practice to improve on the sensitivity obtained with iodine-125 as the label. Conversely, with excess reagent systems for the measurement of proteins it is theoretically possible to increase assay sensitivity at least 1000 fold with alternative luminescent labels. To date, a 10-fold improvement has been achieved, and attempts are being made to reduce the influence of other variables on the specific signal from the immunoreaction.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

Standardized ileal digestibility of amino acids in cereal grains and co-products in growing pigs

  • Lee, Su A;Ahn, Jong Young;Son, Ah Reum;Kim, Beob Gyun
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제33권7호
    • /
    • pp.1148-1155
    • /
    • 2020
  • Objective: The objective was to determine standardized ileal digestibility (SID) of crude protein (CP) and amino acids (AA) in cereal grains and various co-products fed to growing pigs. Methods: Ten feed ingredients tested were barley (9.3% CP), lupin kernels (31.1% CP), and wheat (11.3% CP) as cereal grains, and 2 sources of corn gluten feed produced in China (21.6% CP) and Korea (24.6% CP), corn gluten meal (65.3% CP), lupin hulls (11.6% CP), rice bran (14.5% CP), soybean meal (44.8% CP), and wheat bran (15.4% CP) as co-products. Ten experimental diets were formulated to contain each ingredient as a sole source of N and an N-free diet was used to correct basal endogenous losses of CP and AA. All diets also contained 0.5% Cr2O3 as an indigestible index. A replicated 11×6 incomplete Latin square design with 11 dietary treatments, 6 periods, and 22 animals was employed. Twenty-two barrows with an initial body weight of 64.6±4.9 kg were equipped with a T-cannula in the distal ileum. An experimental period consisted of a 4-d adaptation period and a 2-d collection period. Results: The SID of CP in the barley, lupin kernels, wheat, 2 sources of corn gluten feed, corn gluten meal, lupin hulls, rice bran, soybean meal, and wheat bran were 84.7%, 90.5%, 90.4%, 77.4%, 74.6%, 89.5%, 90.4%, 74.4%, 86.9%, and 63.4% (standard error of the mean [SEM] = 5.3, p = 0.006), respectively. The respective SID values of Lys were 75.5%, 88.4%, 83.9%, 74.7%, 62.4%, 80.3%, 83.9%, 78.5%, 88.0%, and 71.2% (SEM = 3.3, p<0.001), and the SID values of Met were 83.6%, 88.7%, 89.4%, 85.7%, 78.3%, 88.9%, 89.4%, 85.3%, 91.1%, and 77.0% (SEM = 2.4, p<0.001), respectively. Conclusion: The ileal digestibility of protein and amino acids varies among the feed ingredients fed to pigs.

Ochratoxin A의 신장독성감소 방법에 대한 연구 (Study of Antidotes on the Nephrotoxicity of Ochratoxin A)

  • 서경원;김준규;김태완;정세영;김효정
    • 한국식품위생안전성학회지
    • /
    • 제13권2호
    • /
    • pp.121-128
    • /
    • 1998
  • 곰팡이 독소인 ochratoxin A(OA)는 신장독성, 최기형성, 발암성 및 면역독성을 나타내며, 식품, 곡류 및 정육등에 잔류한다고 알려져 있다. 최근 우리나라의 된장, 간장등 발효식품에서도 OA가 검출되었다는 보고가 있어 OA에 대한 관심이 높아지고 있다. 본 연구에서는 OA의 전반적인 위해성 평가의 일환으로 OA의 독성 표적장기인 신장에 초점을 맞추어 신장독성 감소방법을 제시하고자 한다. 신장독성을 감소시키기 위한 대상 물질로는 1) 기존에 독성감소 물질로 알려진 phenylalanine(Phe), 2) phenylalanime과 asparitc acid로 구성된 감미료인 아스파탐(Asp), 3) 녹차의 성분이며 free radical scavenger 및 ntioxidant 작용이 있는 polyphenol(PP), 4) 최근 수명연장 효과가 있고 특히 신장 질환에 대한 예방 효과가 있다고 알려진 aloe 추출물(AE)을 선택하였다. 신장독성을 유발시키기 위하여 OA를 2.0 mg/kg의 용량으로 2주간 연속 경구 투여하였다. Phe(40 mg/kg, i.p.)과 Asp(25 mg/kg, p.o.)은 OA(2.0 mg/kg, p.o.)와 병용 투여하였으며, PP(200 mg/kg, p.o)는 OA 투여 2주전부터, AE(50 mg/kg, i.v.) 은 3일전부터 전처리하여 OA(2.0 mg/kg, p.o.)와 2주간 병용 투여하였다. 신장독성의 확인은 혈청중 BUN, creatinine 치 및 뇨중 ${\gamma}-glutamyltranspeptidase와\;N-acetyl-{\beta}-D-glucosaminidase$의 활성을 측정하였고, 신장에 대한 조직 병리 검사를 실시하였다. 실험결과, OA를 2주간 2.0 mg/kg용량으로 투여한 결과 신장독성이 유발되었으며, 독성 감소 물질로 사용한 4개의 화합물 모두 혈액 및 뇨중 신장독성 지표를 유의성 있게 감소시켰다. 조직 병리 검사결과 OA에 의하여 신장의 근위 세뇨관에 변성이 유발되었으며, 4개의 혼합물 처리군에서는 변성이 관찰되지 않았다. 이러한 결과로부터 Phe, Asp, PP 및 AE는 모두 OA에 의한 신장독성을 감소시킬 수 있으며, OA에 의한 신장독성 유발에는 Phe에 대한 경쟁작용 및 free radical 생성이 관여되어 있음을 알 수 있다.

  • PDF