• 제목/요약/키워드: free tissue

검색결과 1,442건 처리시간 0.033초

백서 상복부 혈관의 동결시간에 따른 변화에 대한 연구 (STUDY OF RAT EPIGASTRIC VESSELS ACCORDING TO THE FREEZING TIME : HISTOLOGIC, HISTOMORPHOMETRIC, IMMUNOHISTOCHEMICAL & SCANNING ELECTRON MICROSCOPIC STUDY)

  • 김우찬;이종헌;김경욱;김창진
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제21권2호
    • /
    • pp.89-109
    • /
    • 1999
  • Vascular spasm which has been reported to occur in 25% of clinical cases continues to be a problem in microvascular surgery; When prolonged and not corrected, it can lead to low flow, thrombosis, and replant or free flap failure. Ischemia, intimal damage, acidosis and hypovolemia have been implicated as contributors to the vascular spasm. Although much work has been done on the etiology and prevention of vasospasm, a spasmolytic agent capable of firmly protecting against or reversing vasospasm has not been found. Therefore vascular freezing was introduced as a new safe method that immediately and permanently relieves the vasospasm and can be applied to microsurgical transfers. Cryosurgery can be defined as the deliberate destruction of diseased tissue or relief the vascular spasm in microvascular surgery by freezing in a controlled manner. 96 Sprague Dawley rats each weighing within 250g were used and divided into 2 group, experimental 1 and 2 group. In the experimental 1 group, right epigastric vessels (artery and vein) were freezed with a cryoprobe using $N_2O$ gas for 1 min. In the experimental 2 group, after freezing for 1 min, thawing for 30 secs and repeat freezing for 30 secs. Left side was chosen as control group in both group. We sacrified the experimental animals by 1 day, 3 days, 1 week, 2 weeks, 4 weeks & 5 months and observed the sequential change that occur during regeneration of epigastric vessels using a histologic, histomorphometric, immunohistochemical and SEM study after the vascular freezing. The results were as follows1. In epigastric arteries, internal diameters had statistically significant enlargement in 1 day, 3 days of Exp-1 group and 1 day, 3 days, 1 week & 2 weeks of Exp-2 group. Wall thickness had statistically significant thinning in 2 weeks of Exp-2 group. 2. In epigastric veins, internal diameters had enlargement of statistical significance in 1 day of Exp-1 and Exp-2 group. 3. The positive PCNA reactions in smooth muscle appeared in 1 week and increased until 2 weeks, decreased in 4 weeks. There was no statistical significance between Exp-1 and Exp-2 group. 4. The positive ${\alpha}$-SMA reaction in smooth muscles showed weak responses until 1 week and slowly increased in 2 weeks and showed almost control level in 4 weeks. 5. The positive S-100 reactions in the perivascular nerve bundles showed markedly decrease in 1 day, 3 days and increased after 1 week and showed almost control level in 4 weeks. Exp-1 group had stronger response than Exp-2 group. 6. In SEM, we observed defoliation of endothelial cell and flattening of vessel wall. Exp-2 group is more destroyed and healing was slower than Exp-1 group. To sum up, relief of vasospasm (vasodilatation) by freezing with cryoprobe was originated from the damage of smooth muscle layer and perivascular nerve bundle and the enlargement of internal diameter in vessels was similar to expeimental groups, but Exp-2 group had slower healing course and therefore vessel freezing in microsurgery can be clinically used, but repeat freezing time needs to be studied further.

  • PDF

후두결절 및 폴립의 후두미세 수술에 관한 임상연구 (Clinical Study on Laryngo - Microscopic Surgery For Vocal Nodules and Polyps)

  • 문영일
    • 대한기관식도과학회:학술대회논문집
    • /
    • 대한기관식도과학회 1983년도 제17차 학술대회연제순서 및 초록
    • /
    • pp.11.2-11
    • /
    • 1983
  • 성대결절 및 성대폴립은 성악인, 교사, 무대예술인 등 음성직업인에게 많이 발생하고 있는 것은 주지의 사실이다. 후두에 경한 염증성 변화가 있을 때 목소리를 남용하면 성대결절이 호발하기 때문에 음성 직업인은 감기 등의 상기도염증이 있을 때는 특히 음성사용에 주의를 기우려야 한다. 성대결절과 폴립이 염증성산물이며 성대의 상피하층의 결체직에서 기원한다는 것은 이미 알려져 있다. 성대의 전 1/3과 중 1/3의 경제부위에 주로 발생하는 것은 그 부위가 진동의 중심부가 되기 때문이다. 이화여자대학교 의과대학부속병원 이비인후과에서 시행한 70예의 후두미세수술 환자를 대상으로 하여 다음과 같은 임상적 고찰을 행하였기에 그 결과를 문헌적 고찰과 함께 보고하는 바이다. 1) 발생초기의 성대결절은 간단한 음성치료로 치유되므로 반드시 결제수술을 시행할 필요는 없다. 2) 소아의 성대결절은 사춘기를 지남에 따라 자연히 소실되는 수가 많으므로 결제수술을 시행하지 않는 것이 좋다. 3) 진행된 성대결절이라 할지라도 음성직업인에게는 우선 3개월 동안 음성치료를 시행하는 것이 좋다. 4) 3개월 동안의 보존적 치료에도 불구하고 성대소견의 개선이 없고 음성장애가 지속되면 후두미세수술을 고려하여야 한다. 5) 수술시에 작은 기도내 삽입관을 사용하여 마취하는 것은 피열간격을 유지하면서 외전된 성대를 유지하는데 필요하다. 6) 성대결절을 제거시 결절을 후방으로 견인하고 그 전방에서부터 제거한다. 7) 어떤 경우에는 결절을 신장시킨 상태에서 감자로 잡고 미세가위나 메스로 절제한다. 8) 음성의 침묵은 술후 일주일동안 시행하며 그 후 일주일은 두사람이 대화할 정도의 약한 목소리를 사용하는 것은 허용해도 좋다.일이내 내원하였으며 25 일 경과후 내원한 경우도 1례가 있었다. 7)식도 및 기도이물의 전례에서 단순 흉부 방사선 촬영을 시행하였고, 이에 나타나지 않은 56례 식도이물을 대상으로 34례에서 식도조영술을 시행하였으며 이중 23례가 양성 소견을 나타냈다. 8) 식도경술에 의해 이물을 제거한 경우는 54례(96.4 %) 였으며, 기관지경술에 의해 이물을 제거한 경우는 14례 (77.8%) 였다. 9 ) 식도 이물에 의한, 또는 식도경술에 의한 합병증이 초래한 경우는 식도점막열상 1례 (1.8 %), 식도 천공 1례 (1.8 %) 였으며, 기도이물에 의한, 또는 기관지경술에 의한 합병증이 초래한 경우는 무기폐 2례 (11.1 %), 폐렴 3례 (16.7 %)로 나타났다.5예에서 소실되었다. 5 ) 청각심리검사 (Psychoacoustic evaluation)에서 폴립은 술전에 Grade 1∼2의 사성이 있었던 11예중 술후 10예에서 Grade 0로 되었으며 Grade 1∼2의 사성이 있었던 3예의 결절에서도 모두 Grade 0로 정상화되었다.>치를 측정한 결과 투여전과 차이가 없었다. 7) 이상의 결과로 볼때 Cis-platinum 사용으로 인한 이중독증은 신장기능이 정상일때는 충분한 hydration으로써 예방이 가능하며 동시에 금기로 알려져왔던 감음성난청이 있는 두경부악성종양환자에서도 세심한 주의하에 적절히 사용한다면 좋은 결과를 얻을 수 있을 것으로 사려된다.은 결과를 얻었기에 문헌고찰과 함께 보고하는 바이다. 1) 이관폐쇄술후 18시간에 최초로 삼출액이 확인되었으며 그 이후는 전실험군에서 삼출성중이염이 유발되다. 2) 도말표본의 세포학적 검사에서 호산구는 전혀 발견되지 않았으며

  • PDF

비소세포 폐암에서 단클론항체 M30를 이용한 세포자멸사 측정 (Detection of Apoptosis by M30 Monoclonal Antibody in Non-small Cell Lung Carcinomas)

  • 김광일;이건;임창영;이헌재
    • Journal of Chest Surgery
    • /
    • 제40권2호
    • /
    • pp.114-121
    • /
    • 2007
  • 배경: 종양 발생기전에 있어서 세포자멸사가 중요한 역할을 한다. 조직 내의 세포자멸사 측정은 TUNEL (terminal deoxyribonucleotidyl transferase mediated nick end lagbelling), ISEL (in situ nick end labelling) 등의 방법을 쓰지만, 반응 세포의 비특이성 및 결과 판독의 주관성 등이 논란의 대상이 되어왔다. 최근 이러한 단점을 보완할 수 있는 단클론항체 M30이 소개되어, 인체 조직의 대장암, 가슴 샘종, 유방암, 자궁내막암 등에서 M30 면역염색을 이용한 세포자멸사 연구가 있었으나 폐암에 대한 연구는 없었다. 저자들은 비소세포 폐암에서 M30 면역염색에 의해 발현되는 세포자멸사 양상이 세포주기 핵심조절자인 p53 면역염색 발현양상 및 임상양상과 갖는 연관성을 살펴보고자 하였다. 대상 및 방법: 비소세포 폐암으로 근치적 절제수술을 받은 환자 45명을 대상으로 하였다. M30과 P53 면역조직화학염색에 실시하여 각 항체의 발현양상과 임상 병리학적 특성을 비교 분석하였다. 술 후 생존기간과 무병 생존기간을 구하였고, 단변량 분석을 실시하여 생존기간에 영향을 미치는 인자를 알아보았다. 다변량 분석을 실시하여 M30과 p53 발현양상이 술 후 사망위험도 및 재발위험도에 미치는 영향을 알아보았다. 결과: M30 양성세포 수는 p53 양성군이 p53 음성군보다 유의하게 많았고(p53 양성군 $61.7{\pm}26.8$개 vs. p53 음성군 $45.6{\pm}29.6$개, p=0.005), 세포사멸사 지수가 1 이상(Apoptosis Index, $Al{\ge}1$)인 환자 수도 p53 양성군에서 유의하게 많았다(p53 양성군 52.4% (l1/21) vs. p53 음성군 16.7% (4/24), p=0.025). 단변량 분석에서는 흡연량, 활동도(Performance Status, PS), 그리고 AI가 술 후 생존기간에 유의한 차이를 보였다. 다변량 분석에서는 AI가 높은 군에서 수술 후 암사망 위험도(Relative risk, R.R 7.482; 95% Confidence Interval, CI $1.886{\sim}29.678$; p=0.004)와 재발 위험도(R.R 3.795; 95% CI $1.184{\sim}12.158$; p=0.025)가 유의하게 증가하였다. p53 발현양상은 수술 후 생존기간과 암사망 위험도 및 재발 위험도에 영향을 미치지 않았다. 결론: 이상의 연구에서 단클론 항체 M30을 이용한 면역조직화학염색이 비소세포 폐암의 세포자멸사를 관찰하는 데 매우 유용한 방법임을 확인하였으며, 환자의 예후를 예측하는 데에도 도움이 될 수 있음을 알 수 있었다.

B형간염(型肝炎) 표면항원(表面抗原)의 주면역원(主免疫原) 결정기(決定基)에 특이(特異)한 합성(合成) Peptide의 면역원성(免疫原性)에 관한 연구(硏究) (Immunogenicity of Synthetic Peptide Specific for Major Immunogenic Determinat of Hepatitis B Surface Antigen)

  • 신광순;한수남
    • 대한수의학회지
    • /
    • 제25권1호
    • /
    • pp.7-17
    • /
    • 1985
  • Many investigators have been pursuing various attempts so far to produce hepatitis B surface antigen(HBsAg) vaccines using the techniques such as isolation from plasma of chronic HBsAg carrier, recombinant DNA technique or preparation of synthetic peptides specific for immunogenic determinants. Hepatitis B virus can not grow on any cell lines by the tissue culture technique at the present time. The plasma of chronic HBsAg carrier is expensive and its source is limited. The HBsAg from the recombinant DNA technique gave still very low yield. Another approach, therefore, has been initiated to develop a synthetic hepatitis B virus vaccine. The possible use of several distinct synthetic vaccines in prophylaxis can be facilitated by availability of full synthetic immunogens. Peptides synthesized for potential application as antiviral vaccines have been mostly tested in the form of conjugates with carrier proteins, although the free synthetic peptide can be immunogenic. To understand basic knowledges on the antigenicity and immunogenicity of a synthetic peptide specific for major immunogenic determinant of HBsAg, a nonapeptide, $H_2N^{139}Cys-Thr-Lys-Pro-Thr-Asp-Gly-^{146}Asn-Aba$ COOH, which corresponds to HBsAg amino acid residues 139 to 147, was synthesized by the Merrifield's solid-phase method with a slight modification. The antigenicity and immunogenicity of this specific synthetic peptide were examined comparing with purified plasma-derived natural HBsAg. The results obtained are as follows; 1. The peptide synthesized showed the identical amino acid composition to the theoretical value. The degree of purification and molecular weight were acertained by methods of high performance liquid chromatography and mass spectrometry. 2. Using m-maleimidobenzoyl-N-hydroxysuccinimide ester as a conjugating agent, the synthetic peptide was conjugated to rabbit albumin and ${\gamma}$-globulin, tetanus and diphtheria toxoids, and keyhole limpet hemocyanin. Their conjugation yields were 8.3, 9.5, 15.8, 13.5, and 11.2%, respectively. 3. The natural HBsAg was purified from plasma of chronic HBsAg carrier. By the electron microscopic observation of the purified natural HBsAg preparation, no Dane particles were observed and the preparation showed negative DNA polymerase activity. 4. Antigenicity of the synthetic peptide and the plasma-derived natural HBsAg was determined by competition radioimmunoassay using $^{125}I$-natural HBsAg. Their 50% inhibitions appeared as $90{\mu}g/ml$ and $0.12{\mu}g/ml$ for the synthetic peptide and the natural HBsAg, respectively. This indicates that the former was about 750-fold less antigenic than the latter. 5. Immunogenicity of the synthetic peptide was determined by administering the peptide-carrier conjugates into rabbits with and without Freund's complete adjuvant. Regardless the carrier proteins and adjuvant, positive immune responses to the synthetic peptide were observed. The higher antibody titers, however, were shown in the groups administered with Freund's complete adjuvant. 6. Immunizing dose 50% in mice of the various peptide-carrier conjugates was 5.47, 6.00, 65.16, 31.25 and $13.03{\mu}g/dose$ for rabbit albumin and ${\gamma}$-globulin, tetanus and diphtheria toxoids, and keyhole limpet hemocyanin, respectively, while the natural HBsAg showed $0.65{\mu}g/dose$. 7. It was postulated that homologous proteins prefer to heterologous ones as the carriers.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

목본식물(木本植物)의 약배양(葯培養)에 관(關)한 연구(硏究) (Studies on the Anther Culture of Some Woody Species)

  • 김재생
    • 한국산림과학회지
    • /
    • 제13권1호
    • /
    • pp.25-39
    • /
    • 1971
  • 약배양(葯培養)에 의(依)한 반수체식물(半數體植物)의 유기(誘起)가 돌연변이(突然變異), 유전학등(遺傳學等)의 기초연구(基礎硏究)나 실지육종사업(實地育種事業)에 혁신(革新)을 갖져올 수 있다는 사실(事實)이 알려지자 최근(最近) 2-3년간(年間) 이에 대(對)하여 많은 연구(硏究)가 시도(試圖)되었지만 현재(現在)까지 성공(成功)된 식물(植物)의 종류(種類)는 수종(數種)에 불과(不過)하다. 식물(植物)의 여러조직배양법(組織培養法) 중(中)에서도 약배양(葯培養)이 특(特)히 힘든것은 이 경우(境遇)에는 환원소포자(還元小胞子)에서 Callus가 embryoid를 유기(誘起)하여야만 되기 때문이다. 과수(果樹)와 화목류(花木類) 4속(屬) 7종(種)의 식물(植物)을 대상(對象)으로 약배양(葯培養)을 시도(試圖)하였다. 배양약(培養葯)은 대개(大槪) 4분자(分子)에서 늦은 소포자기(小胞子期)의 것을 혼합(混合)하여 사용(使用)하였고 배양기(培養基)는 Modified murashige and skoog의 배지(培地)를 기본배지(基本培地)로 하고 여기에 NAA, $2{\cdot}4$-D, YE, Kinetin등(等) 생장조절물질(生長調節物質)을 농도(濃度)와 조합(組合)을 달리한것을 첨가(添加)하여 만들었다. 재료(材料)의 취급(取扱), 멸균배양(滅菌培養)에 따른 여러조작(操作), 조직표본작성등(組織標本作成等) 모든것은 상법(常法)에 의(依)하였다. 이제 성적(成績)을 요약(要略)하면 다음과 같다. 1. Callus는 개나리, 진달래, 산철쭉, 살구 등(等)에서 형성(形成)되었고 복숭아, 배, 자두에서는 안생긴다. 2. Auxin Kinetin의 종류(種類)와 농도(濃度)를 달리한 여러 배양기(培養基)를 사용(使用)하였지만 Callus형성(形成)은 어느 것에서나 잘된다. 3. 개나리에서는 Callus는 약표면(葯表面), 약격부위(葯隔部位)에서 체세포기원(體細胞起源)의 2배성(倍性) Callus가 생기고 소포자(小胞子)에서는 안생긴다. 오래 배양(培養)된 소포자(小胞子)에서는 대부분(大部分) 전분(澱粉)이 축적(蓄積)된다. 4. 진달래에서는 화사(花絲), 약격(葯隔), 약내동(葯內童) 등(等)에서 체세포성(體細胞性) Callus가 형성(形成)되고 소포자기원(小胞子期源)의 Callus는 안생기고 소포자(小胞子)에는 전분(澱粉)이 축적(蓄積)된다. 5. 산철쭉은 Callus형성(形成)이 화사(花絲), 약격등(葯隔等)에서도 생기지만 주(主)로 화사반대편(花絲反對便)의 약이첨단(葯耳尖端)에서 잘생긴다. 소포자기원(小胞子期源)의 Callus는 안생기고 소포자(小胞子) 전분(澱粉)이 축적(蓄積)되는 점(點)은 진달래와 같다. 6. 살구는 체세포성(體細胞性) 약조직기원(葯組織起源)의 Callus는 거이 안생기고 Callus는 약강내부(葯腔內部)에서 형성(形成)되어 약봉합부(葯縫合部)를 헤치고 나온다. 오래 배양(培養)된 소포자(小胞子)에도 전분(澱粉)은 축적(蓄積)되지 않는다. 7. 복숭아, 배, 자두 들에서는 60여일배양(餘日培養)된 약(葯)의 어느 부위(部位)에서도 Callus는 형성(形成)되지 않는다. 반면(反面) 소포자(小胞子)에 전분축적(澱粉蓄積)도 안되는것이 특징(特徵)이다. 8. 체세포(體細胞) Callus는 주(主)로 약벽내피(葯壁內被), 두 약강(葯腔)사이의 격막(隔膜), 약격(葯隔) 및 약이유조직등(葯耳柔組織等)에서 생긴다. 9. 살구의 약조직(葯組織)은 배양중(培養中) 별(別)로 변화(變化)가 안되지만 소포자(小胞子)는 변화(變化)하야 다핵소포자(多核小胞子), 다조포체(多組胞體)들이 약강내(葯腔內)에 출현(出現)한다. 이런 현상(現像)은 살구의 Callus는 소포자기원(小胞子期源) 이라는것을 표시(表示)해준다. 10. 7종(種)의 식물중(植物中) 살구만은 환원성(還元性) 소포자(小胞子) Callus가 생기고 기타(基他)의 식물(植物)들은 약(葯)의 체세포성(體細胞性) 조직(組織)에서 Callus가 형성(形成)되기 때문에 반수체육종(半數體育種)의 가능성(可能性)은 살구에서만 있다.

  • PDF

관상동맥우회술 시 사용된 박동성펌프$(T-PLS^{TM})$와 비박동성펌프$(Bio-pump^{TM})$의 비교연구 (The Comparative Study of on Pump CABG during Pulsatile $(T-PLS^{TM})$ and Nonpulsatile $(Bio-pump^{TM})$ Perfusion)

  • 박영우;허균;임재웅;신화균;원용순
    • Journal of Chest Surgery
    • /
    • 제39권5호
    • /
    • pp.354-358
    • /
    • 2006
  • 배경: 체외순환에 사용되는 박동성 펌프는 비박동성 펌프에 비해 조직관류가 좋지만 혈구손상이 많다고 알려져 왔다. 관상동맥우회술 시 박동성 펌프인 $T-PLS^{TM}$(이중 박동성 인공심폐기)와 비박동성 펌프인 $Bio-pump^{TM}$의 임상결과를 비교하여 $T-PLS^{TM}$의 안전성 및 장단점을 알아보고자 하였다. 대상 및 방법: 2003년 4월부터 2005년 6월까지 관상동맥우회술을 시행 받은 40명을 대상으로 하였다. $T-PLS^{TM}$을 이용하여 관상동맥 우회술을 시행 받은 환자는 20명이었고 $Bio-pump^{TM}$을 이용하여 관상동맥우회술을 시행 받은 환자는 20명이었다. 수술은 모든 환자에서 심폐체외순환하에서 박동하여 시행하였다. 수술 전 위험인자와 수술 중 상태, 술 후 결과를 비교하였다. 결과: 두 군 간 연령, 남녀비, 당뇨, 고혈압, 흡연력 및 폐쇄성 폐질환, 심근경색, 신부전 등 술 전 위험요소는 차이가 없었다. 수술시간, 심폐기 사용시간, 사용한 우회도관 및 문합한 관상동맥분지는 두 군에서 차이가 없었다. 수술 중 수축기 동맥압, 이완기 동맥압, 평균동맥압은 두 군 간 차이는 없었지만 맥박압은 $T-PLS^{TM}$군에서 높게 측정되었다$(46{\pm}15\;mmHg\;in\;T-PLS^{TM}\;vs\;35{\pm}13\;mmHg\;in\;Bio-pump^{TM},\;p<0.05)$. 수술 중 소변량은 $T-PLS^{TM}$군에서 높은 경향이 있었지만 통계적 의미는 없었다$(9.7{\pm}3.9\;in\;T-PLS^{TM}\;versus\;8.9{\pm}3.6\;in\;Bio-pump^{TM},\;p=0.20)$. 수술 후 평균 호흡기 사용시간, 24시간 실혈량은 두 군간 차이는 없었다. 수술 후 유리혈장색소는 $T-PLS^{TM}$군에서 유의하게 낮게 측정되었다$(24.5{\pm}21.7\;mg/dL\;in\;T-PLS^{TM}\;vs\;46.8{\pm}23.0\;in\;Bio-pump^{TM},\;p<0.05)$. 수술 후 심근경색, 부정맥, 신부전, 뇌혈관질환 이환율은 두 군에서 차이가 없었다. 수술 후 사망은 $T-PLS^{TM}$군에서 1예(5%) 발생하였으나 통계적 유의성은 없었다. 결론: 박동성 혈류펌프인 $T-PLS^{TM}$를 이용하여 심폐기하 관상동맥 우회술을 시행하였다. 수술 중 기계오류에 의한 사고는 없었고 수술 후 임상경과가 $Bio-pump^{TM}$를 이용하여 수술한 경우와 차이가 없었다. 또한 박동성 혈류의 문제점이었던 혈구손상은 감소하였다. 저자들은 본 연구를 통해 $T-PLS^{TM}$의 안정성을 확인하였다.

$TiO_2$로 처치된 백서에서 기도내 배상세포 증식과 염증에 대한 Dexamethasone의 효과 (The Effect of Dexamethasone on Airway Goblet Cell Hyperplasia and Inflammation in $TiO_2$-Treated Sprague-Dawley Rats)

  • 임건일;김도진;박춘식
    • Tuberculosis and Respiratory Diseases
    • /
    • 제49권1호
    • /
    • pp.37-48
    • /
    • 2000
  • 연구배경 : 기관지 천식등과 같은 만성 기도질환의 병태생리는 점액의 과분비, 배상세포의 과형성, 평활근의 비후와 호산구등의 염증세포의 침윤등으로 설명되고 있다. 배상세포의 증식에 대한 생화학적 기전은 이러한 양상을 만드는데 필요한 시간이 길고, 기도염증과 연관된 매우 복잡함 때문에 아직 잘 알려지지 않고 있다. 이에 본 저자들은 배상세포증식과 기도염증의 상관성을 알고자 그 첫 단계로 백서의 기관을 통한 $TiO_2$의 주입으로 단시간 내에 형성되는 배상세포증식의 동물 모형을 만들어 기도내 주로 어느 부위에서 배상세포의 과형성이 나타나는지 관찰하고 염증세포의 침윤 여부 및 dexamethasone 이 과형성된 배상세포 및 침윤된 염증세포에 대해 영향을 평가해 보고자 하였다. 방법 : 8주된 21마리의 수컷 Sprague-Dawley를 세 군으로 나누어서 첫 번째 군(group 1) 은 endotoxin-free water를 기관내 주입하고 두 번째 군(group 2)은 $TiO_2$를 주입을 하고 세 번째 군(group 3)은 $TiO_2$를 주입하고 dexamethasone을 $TiO_2$ 투여전날부터 희생전날까지 투여하였다. 흰쥐를 희생시켜 기관, 기관지와 폐 부위를 각각 절제하여 paraffin bloc을 만든 후 $4{\mu}m$의 section을 하여 PAS 염색한 후 각 부위에서의 상피세포에 대한 배상세포의 비를 구하여 각 군별로 비교하였고, Luna 염색으로 호산구의 침윤을 비교하였다. 결과 : 1. 기관에서의 배상세포의 비의 평균은 1군에서는 4.09$\pm$8.28%, 2군은 10.19$\pm$11.33%로 $TiO_2$를 주입한 2군에서 배상세포의 과형성을 관찰할 수 있었다 (P<0.01). 2. 주 기관지에서의 배상세포의 비의 평균은 1군에서 3.61$\pm$4.84%, 2군에서는 34.09$\pm$23.91%로 $TiO_2$를 주입한 2군에서 배상세포의 과형성을 관찰 할 수 있었다(P<0.01). 3. 세기관지 부위에서의 배상세포의 양성 incidence와 severity (R$\times$S)로 표시를 하였으며 이는 각각 1 군은 0, 2군은 0.3 이었다. 4. 침윤된 호산구는 1군(1.99$\pm$3.84%)에서보다 2군 (21.43$\pm$23.85%)에서 유의하게 증가되었다(p<0.05). 5. 1군, 2군, 3군의 주기관지내에서 배상세포의 과형성과 호산구 침윤간에는 의미있는 상관관계를 보였다(p=0.001). 6. dexamethasone이 배상세포의 과형성과 호산구의 침윤을 억제함을 관찰하였다. 결론 : 백서에서 $TiO_2$로 처치시 기도에서 배상세포의 과형성이 5일내에 주로 주 기관지에서 발생하였으며 호산구 침윤이 동반하는 배상세포 증식의 동물 모형이 만들어졌다. 배상세포의 과형성은 염증과 동반되며 dexamethasone 투여시 억제되므로, 배상세포의 증식기전 에서 기도내 염증과정이 주요한 역할을 하는 것으로 생각된다. 향 후 이러한 동물 모형은 배상세포 증식의 기전을 이해하는데 유용한 도구가 될 것으로 사료된다.

  • PDF

흰쥐 폐동맥의 내피세포의존성 혈관이완과 급성 저산소성 폐동맥수축에서 산화질소의 역할 (A Study of Endothelium-dependent Pulmonary Arterial Relaxation and the Role of Nitric oxide on Acute Hypoxic Pulmonary Vasoconstriction in Rats)

  • 인광호;이진구;조재연;심재정;강경호;유세화
    • Tuberculosis and Respiratory Diseases
    • /
    • 제41권3호
    • /
    • pp.231-238
    • /
    • 1994
  • 연구배경: 저산소증에 의한 폐동맥수축의 기전은 저산소증 자체가 폐혈관 평활근에 직접 작용하여 수축을 유발한다는 것과, 저산소증에 의해 조직으로 부터 여러 매개물질이 유리되어 혈관평활근을 수축시킨다는 설이 제시되고 있지만 정확히 밝혀져있지 않다. 최근에는 저산소증이 EDRF의 생성을 억제하여 혈관수축을 유발시킨다고하여 관심이 되고 있다. 본 연구에서는 흰쥐 폐동맥에서 내피세포 의존형 혈관이완을 조사하고, 저산소증에 의한 폐동맥수축에 EDRF의 작용을 조사하였다. 방법 : 300~350g의 수컷 흰쥐(Sprague Dawley)의 폐동맥을 박리하여 길이가 2mm되는 폐동맥고리를 Krebs용액으로 채워져 있으며, 95% $O_2$/5% $CO_2$(산소상태)와 95% $N_2$/5% $CO_2$(저산소상태)가 각각 공급되는 magnus관에서 가는 stainless 갈고리로 고정한 다음 Gilson사의 polygraph에 부착된 isometric transducer(FT.03 Grass, Quincy, USA)에 의해 등장성 수축곡선을 그리도록 장치하였다. 결과: 1) 내피세포가 있는 폐동맥에서 PE($10^{-6}M$)에 의한 혈관수축은 Ach($10^{-9}-10^{-5}M$) 및 SN($10^{-9}-10^{-5}M$)의 농도에 비례해서 이완되어 거의 기초장력까지 이완되었으나, 내피세포를 제거한 폐동맥에서는 Ach($10^{-9}-10^{-5}M$)에 의한 혈관이완은 거의 상실되었다. 2) L-NMMA($10^{-4}M$)으로 전처치한 경우 Ach($10^{-9}-10^{-5}M$)에 의한 혈관이완은 전처치하지 않은 경우보다 의미있게 감소하였다. 3) L-arginine($10^{-4}M$)과 L-NMMA($10^{-4}M$)을 전처치 하였을 경우 Ach($10^{-9}-10^{-5}M$)에 의한 혈관이완은 L-NMMA에 의해 거의 영향을 받지 않았다. 4) PE($10^{-6}M$)에 의한 폐동맥 수축은 산소상태보다 저산소 상태에서 훨씬 강했으며, Ach($10^{-9}-10^{-5}M$)에 의한 혈관이완은 산소상태보다 저산소상태에서 의미있게 감소하였다. 5) L-arginine($10^{-4}M$)을 전처치 하였을 경우 저산소상태에서의 Ach($10^{-9}-10^{-5}M$)에 의한 혈관이완은 산소상태에서의 Ach 에 의한 혈관이완 정도로 회복되었다. 결론: 흰쥐 폐동맥에서 내피세포의존성 혈관이완은 NO가 관여하며, 저산소증에 의한 폐동맥 수축은 내피세포내의 EDRF 생성의 저하와 관련이 있을 것으로 사료된다.

  • PDF