• 제목/요약/키워드: fractures

검색결과 2,660건 처리시간 0.023초

Mapping the Posterior Ledge and Optic Foramen in Orbital Floor Blowout Fractures

  • Yu Cong Wong;Doreen S.L. Goh;Celine S.Y. Yoong;Cowan Ho;Elijah Z. Cai;Angela Hing;Hanjing Lee;Vigneswaran Nallathamby;Yan L. Yap;Jane Lim;Sundar Gangadhara;Thiam C. Lim
    • Archives of Plastic Surgery
    • /
    • 제50권4호
    • /
    • pp.370-376
    • /
    • 2023
  • Background The posterior ledge (PL) is a vital structure that supports the implant posteriorly during orbital floor reconstruction. This study describes a technique for mapping the PL in relation to the infraorbital margin (IM) in patients with orbital floor blowout fractures. This study establishes the location of the optic foramen in relation to the PL. Methods Facial computed tomography (FCT) scans of 67 consecutive patients with isolated orbital floor blowout fractures were analyzed using Osirix. Planes of reference for orbital fractures, a standardized technique for performing measurements on FCT, was used. Viewed coronally, the orbit was divided into seven equal sagittal slices (L1 laterally to L7 medially) with reference to the midorbital plane. The distances of PL from IM and location of optic foramen were determined. Results The greatest distance to PL is found at L5 (median: 30.1 mm, range: 13.5-37.1 mm). The median and ranges for each slice are as follows: L1 (median: 0.0 mm, range: 0.0-19.9 mm), L2 (median: 0.0 mm, range: 0.0-21.5 mm), L3 (median: 15.8 mm, range: 0.0-31.7 mm), L4 (median: 26.1 mm, range: 0.0-34.0 mm), L5 (median: 30.1 mm, range: 13.5-37.1 mm), L6 (median: 29.0 mm, range: 0.0-36.3 mm), L7 (median: 20.8 mm, range: 0.0-39.2 mm). The median distance of the optic foramen from IM is 43.7 mm (range: 37.0- 49.1) at L7.

Clinical characteristics of patients with the hardware failure after surgical stabilization of rib fractures in Korea: a case series

  • Na Hyeon Lee;Sun Hyun Kim;Seon Hee Kim;Dong Yeon Ryu;Sang Bong Lee;Chan Ik Park;Hohyun Kim;Gil Hwan Kim;Youngwoong Kim;Hyun Min Cho
    • Journal of Trauma and Injury
    • /
    • 제36권3호
    • /
    • pp.196-205
    • /
    • 2023
  • Purpose: Surgical stabilization of rib fractures (SSRF) is widely used in patients with flail chests, and several studies have reported the efficacy of SSRF even in multiple rib fractures. However, few reports have discussed the hardware failure (HF) of implanted plates. We aimed to evaluate the clinical characteristics of patients with HF after SSRF and further investigate the related factors. Methods: We retrospectively reviewed the electronic medical records of patients who underwent SSRF for multiple rib fractures at a level I trauma center in Korea between January 2014 and January 2021. We defined HF as the unintentional loosening of screws, dislocation, or breakage of the implanted plates. The baseline characteristics, surgical outcomes, and types of HF were assessed. Results: During the study period, 728 patients underwent SSRF, of whom 80 (10.9%) were diagnosed with HF. The mean age of HF patients was 56.5±13.6 years, and 66 (82.5%) were men. There were 59 cases (73.8%) of screw loosening, 21 (26.3%) of plate breakage, 17 (21.3%) of screw migration, and seven (8.8%) of plate dislocation. Nine patients (11.3%) experienced wound infection, and 35 patients (43.8%) experienced chronic pain. A total of 21 patients (26.3%) underwent reoperation for plate removal. The patients in the reoperation group were significantly younger, had fewer fractures and plates, underwent costal fixation, and had a longer follow-up. There were no significant differences in subjective chest symptoms or lung capacity. Conclusions: HF after SSRF occurred in 10.9% of the cases, and screw loosening was the most common. Further longitudinal studies are needed to identify risk factors for SSRF failure.

Automatic Detection and Classification of Rib Fractures on Thoracic CT Using Convolutional Neural Network: Accuracy and Feasibility

  • Qing-Qing Zhou;Jiashuo Wang;Wen Tang;Zhang-Chun Hu;Zi-Yi Xia;Xue-Song Li;Rongguo Zhang;Xindao Yin;Bing Zhang;Hong Zhang
    • Korean Journal of Radiology
    • /
    • 제21권7호
    • /
    • pp.869-879
    • /
    • 2020
  • Objective: To evaluate the performance of a convolutional neural network (CNN) model that can automatically detect and classify rib fractures, and output structured reports from computed tomography (CT) images. Materials and Methods: This study included 1079 patients (median age, 55 years; men, 718) from three hospitals, between January 2011 and January 2019, who were divided into a monocentric training set (n = 876; median age, 55 years; men, 582), five multicenter/multiparameter validation sets (n = 173; median age, 59 years; men, 118) with different slice thicknesses and image pixels, and a normal control set (n = 30; median age, 53 years; men, 18). Three classifications (fresh, healing, and old fracture) combined with fracture location (corresponding CT layers) were detected automatically and delivered in a structured report. Precision, recall, and F1-score were selected as metrics to measure the optimum CNN model. Detection/diagnosis time, precision, and sensitivity were employed to compare the diagnostic efficiency of the structured report and that of experienced radiologists. Results: A total of 25054 annotations (fresh fracture, 10089; healing fracture, 10922; old fracture, 4043) were labelled for training (18584) and validation (6470). The detection efficiency was higher for fresh fractures and healing fractures than for old fractures (F1-scores, 0.849, 0.856, 0.770, respectively, p = 0.023 for each), and the robustness of the model was good in the five multicenter/multiparameter validation sets (all mean F1-scores > 0.8 except validation set 5 [512 x 512 pixels; F1-score = 0.757]). The precision of the five radiologists improved from 80.3% to 91.1%, and the sensitivity increased from 62.4% to 86.3% with artificial intelligence-assisted diagnosis. On average, the diagnosis time of the radiologists was reduced by 73.9 seconds. Conclusion: Our CNN model for automatic rib fracture detection could assist radiologists in improving diagnostic efficiency, reducing diagnosis time and radiologists' workload.

텐던 파단 음파의 분석 (Analysis of Acoustic Signals of Tendon Fractures)

  • 윤석구;김은겸;최민석;김현겸
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.243-246
    • /
    • 2005
  • Using long-tenn monitoring AE techniques, two acoustic signals of wire fractures in a PSC beam are obtained. These data are compared to other noise signals. Based on the test results, the characteristics of the AE signals are classified and wire fracture signals are figured out among the other AE signals.

  • PDF

하악골 과두경부 골절의 정복술 시 retromandibular approach의 유용성에 관한 고찰 (RETROMANDIBULAR APPROACH FOR OPEN REDUCTION & INTERNAL FIXATION OF MANDIBULAR CONDYLAR NECK FRACTURE)

  • 백진아
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제33권6호
    • /
    • pp.625-630
    • /
    • 2007
  • Fractures of the mandibular condyle are account for between 26% and 57% of all mandibular fractures. Clinicians should decide how to treat the fractured condyle with many factors considered. Many surgical methods have been developed to reduction of fractured condyle and it' s internal fixation. In open reduction of fractured condylar neck and subcondyle, retromandibular approach offers a safe and effective approach for direct fixation due to easy access and low surgical morbidity.

Pulmonary Thromboembolism during Acetabular Fracture Operation

  • Seo, Il;Oh, Chang-Wug;Kim, Joon-Woo;Park, Kyeong-Hyun
    • Journal of Trauma and Injury
    • /
    • 제31권2호
    • /
    • pp.72-75
    • /
    • 2018
  • Acetabular and Pelvic ring fractures are major high-energy trauma injuries and are often combined with other injuries. In particular, cause of long duration of immobilization and combined injuries, venous thromboembolism is a common complication in trauma patients with pelvic or acetabular fractures. We report a case of a fatal pulmonary thromboembolism during the acetabulum fracture operation in a 62-year-old male patient.

악안면 골절후 발생된 상안와열증후군;증례보고 (Traumatic Superior orbital fissure syndrome complicating fractures of the facial skeleton;Report of a Case)

  • 김수관
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제22권3호
    • /
    • pp.356-359
    • /
    • 2000
  • Superior orbital fissure syndrome is characterized by ophthalmoplegia, ptosis of the eye, reflex dilation of the pupil, and anesthesia of the upper eyelid and forehead. This syndrome may be the result of craniofacial fractures as well as neoplasms of the retrobulbar space, hematomas in the orbital muscle cone and retrobulbar space, and hematoma and infection of the cavernous sinus. A case of superior orbital fissure syndrome is described.

  • PDF

Successful use of Gasserian ganglion block for maxillo-mandibular fixation in a patient with severe pulmonary dysfunction-a case report

  • Vadhanan, Prasanna
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제20권5호
    • /
    • pp.331-335
    • /
    • 2020
  • Various anesthetic techniques have been utilized for maxillo-mandibular fixation. We report the case of a patient with bilateral condylar and zygomatic arch fractures who had severe pulmonary dysfunction. The patient was administered bilateral image-guided Gasserian ganglion block through the foramen ovale to achieve surgical anesthesia. The technical details, advantages, and disadvantages of this rather unusual technique are discussed. The procedure could be a feasible technique when performed meticulously in cases where other approaches are deemed difficult.

Odontoid Synchondrosis Fracture Treated by C1-2 Polyaxial Screw-Rod Fixation

  • Muthukumar, Natarajan
    • Journal of Korean Neurosurgical Society
    • /
    • 제55권4호
    • /
    • pp.212-214
    • /
    • 2014
  • The synchondrosis between the dens and the body of axis normally fuses between 5 and 7 years of age. Until this age, synchondrosis fractures can occur in children. Most synchondrosis fractures are conventionally treated by external immobilization alone. We report a 10-year-old child with odontoid synchondrosis fracture who was treated by C1 lateral mass and C2 pars screw rod fixation with a successful outcome and discuss the possible reasons for occurrence of odontoid synchondrosis fracture in this older child as well as the indications for surgery in this condition.