• Title/Summary/Keyword: fractured zone

Search Result 147, Processing Time 0.026 seconds

Dual-Porosity Models with Linear Flow Pattern (매트릭스 블록선형유동에 관한 이중공극 모델)

  • 함세영;성익환
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.6 no.1
    • /
    • pp.1-7
    • /
    • 1999
  • This study deals with linear flow pattern in steady-state or transient dual-porosity media with a vertical geologic structure such as fault, fracture zone, etc. A pumping well is located in the vertical structure of infinitesimal or finite width with high hydraulic conductivity and negligible specific storage. Selected type curves on a pumping well and observation wells in the fractured system and the matrix block are provided. The type curves on the pumping well considers both wellhole and well-loss effects.

  • PDF

Characteristics of Welded Zone Using Solar Energy Concentration (태양광선을 이용한 용접부 특성)

  • Prasad, K.D.V.;Kim, I.S.;Sung, B.S.;Kim, B.C.
    • Journal of the Korean Solar Energy Society
    • /
    • v.21 no.2
    • /
    • pp.9-17
    • /
    • 2001
  • In this paper the attempts made by the authors to explore the feasibility of utilising concentrated solar beam radiation for joining engineering thermoplastics such as Acrylonitrilc/Butadiene/Styrene (ABS), Polycarbonate(PC) and Polymethylmethacrylate(PMMA) are presented. In addition, to study the joining of the materials, necessary experimentation with applying primer was performed. Tensile tests were conducted to determine the bond strength achieved at the specimen joint interface. Microscopic examinations of the fractured joints were performed in order to analyse the overall bond quality. Finally, the results in terms of bond strength achieved at the joint interface and energy consumed in the process were compared with those obtained with similar thermoplastic joining technique utilising microwave energy. In conclusion some advantages and limitations were outlined and necessary improvements of the jointing technique were recommended.

  • PDF

Stability evaluation of foundation settlement of power transmission tower (송전철탑의 기초침하에 대한 안정성 평가)

  • Lee, Dae-Soo;Cho, Hwa-Kyung;Kim, Dae-Hong;Ham, Bang-Uk
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.687-696
    • /
    • 2005
  • Safety diagnosis was conducted to evaluate the long-term stability evaluation of power transmission tower of which deformation of the upper structural elements occurred. To assess the cause of the structural deformation, field investigation including BIPS, down-hole test, concrete pile coring and finite element analysis were carried out. From these studies, the major cause of deformation was found due to the heavily fractured layer and weathered soil topography at the pile tip area. The cement-milk grouting method was proposed to reinforce these weak zone around the pile tip area. Also, the increase of cross-section and stiffness for steel members of upper tower structures was suggested. Instrumental monitoring was proposed as well to verify reinforcing effect.

  • PDF

Induced Polarization Prospecting at the Dongjeom Copper Mine (동점광산(銅店鑛山) 동광상(銅鑛床)에 대(對)한 I.P물리탐사(物理探査))

  • Bang, Ki Yual;Lee, Seung Jong;Han, Min Ho;Lee, Kyong Yong
    • Economic and Environmental Geology
    • /
    • v.18 no.4
    • /
    • pp.301-308
    • /
    • 1985
  • I.P exploration is conducted mainly at the alluvium covered granodiorite stock of the Red Hill area at the Dongjeom coal mine, employing Canadian Mcphar equipments of variable frequencies-domain method along a total of 8.5 survey line. Mineralization zone is found by LP anomalies along the I.P the profile of frequency mode. Comparing with the past drilling data, the cause of each anomly is furthermore identified as copper bearing mineralized zones. As alteration and mineralization cover all over the Red-Hill altered grandiorite, copper bearing sulfide veinlets and strings filled out the fractured and altered zones.

  • PDF

An experimental study on the unequal thickness joint using FSW with $4mm^{t}$ and $6mm^{t}$ Al 6061 T6 plates (Al 6061 T6 합금의 이두께 마찰교반 용접에 관한 연구)

  • Ryu, Deok-Hui;Kim, Jae-Seong;Jin, Hyeong-Guk;Lee, Jae-Hun;Lee, Bo-Yeong
    • Proceedings of the KWS Conference
    • /
    • 2005.06a
    • /
    • pp.223-225
    • /
    • 2005
  • In order to demonstrate the friction stir weldability of the Al 6061 T-6 unequal thickness joint and determine optimum welding parameters, the relations between welding parameters and properties of the joints have been studied in this paper. The experimental results showed that the tensile properties of the joints are affected by the welding heat inputs and tool shape. In this study, the maximum ultimate strength of the as-welded joint is equivalent to 78% and 18hour aged joint is equivalent to 93% that of the base metal. Though the voids-free joints are fractured at the thermally affected zone on the advancing side, the fracture occurs at the weld center when the void defects exist in the joints.

  • PDF

Groundwaterflow analysis of discontinuous rock mass with probabilistic approach (통계적 접근법에 의한 불연속암반의 지하수 유동해석)

  • 장현익;장근무;이정인
    • Tunnel and Underground Space
    • /
    • v.6 no.1
    • /
    • pp.30-38
    • /
    • 1996
  • A two dimensional analysis program for groundwater flow in fractured network was developed to analyze the influence of discontinuity characteristics on groundwater flow. This program involves the generation of discontinuities and also connectivity analysis. The discontinuities were generated by the probabilistic density function(P.D.F.) reflecting the characteristics of discontinuities. And the fracture network model was completed through the connectivity analysis. This program also involves the analysis of groundwater flow through the discontinuity network. The result of numerical experiment shows that the equivalent hydraulic conductivity increased and became closer to isotropic as the density and trace length increased. And hydraulic head decreased along the fracture zone because of much water-flow. The grouting increased the groundwater head around cavern. An analysis of groundwater flow through discontinuity network was performed around underground oil storage cavern which is now under construction. The probabilistic density functions(P.D.F) were obtained from the investigation of the discontinuity trace map. When the anisotropic hydraulic conductivity is used, the flow rate into the cavern was below the acceptable value to maintain the hydraulic containment. But when the isotropic hydraulic conductivity is used, the flow rate was above the acceptable value.

  • PDF

Estimation of the Groundwater Discharges in Masan Bay Watershed (마산만 유역의 지하수 유출량 추정)

  • Yang Jeong-Seok;Cho Hong Yeon;Jeong Shin Taek;Kim Sang Jun
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.16 no.4
    • /
    • pp.213-223
    • /
    • 2004
  • The discharges of groundwater flow were estimated using Darcy's method along the coastal zone in the Masan Bay. The estimates using the information, i.e., groundwater level, location of the observation well, hydraulic conductivity, the thickness of the aquifer, and coastline length, were 1.65% of the precipitation of the watershed. The estimated groundwater discharges through fractured rock aquifer and the aquifer with sedimentary material were $0.7\times10^4$$m^2/year$and $1.0\times10^7$$m^3/year$ respectively. Whereas, the discharge estimated by KORDI (2003) using isotopes method is about 20 times larger than the estimates from this study because of the influence of the re-circulated seawater through the coastal zone aquifer. In order to quantify this effect in detail, the groundwater levels and salinity changes in the observation wells located in the coastal zone should be continuously monitored and analyzed.

A Study on Analysis for the Characteristics of Fault Zone at Mica-schist for Reinforcement of Large-Span Tunnel (대단면 터널 보강을 위한 운모편암 단층대 특성 분석에 관한 연구)

  • Chung, Hoi-Yong;Kim, Young-Geun;Park, Yeon-Jun;You, Kwang-Ho
    • Tunnel and Underground Space
    • /
    • v.19 no.2
    • /
    • pp.132-145
    • /
    • 2009
  • Faults in rock mass have strong influences on the behaviors of rock structure such as rock slope, tunnel and underground space. Thus, it is very important to analyse for the characteristics of fault rocks in design for tunnel. But, due to the limitation of geotechnical investigation in design stages, tunnel engineers have to carry out the face mapping and additional geological survey during tunnel excavation to find the distribution of faults and the engineering properties of faults for support and reinforcement design of tunnel. In this study, various geological survey and field tests were carried out to analyse the characteristics of the large thrust fault zone through the large sectional tunnel is constructed in mica-schist region. Also, the distribution of structural geology, the shape of thrust faults and the mechanical properties of fault rock were studied for the reasonable design of the reinforcement and support method for the highly fractured fault zone in the large-span tunnel.

Characteristics of $CO_2$ or Nd:YAG Laser Welded 600MPa Grade TRIP Steel (600MPa급 TRIP강의 $CO_2$ 및 Nd:YAG 레이저 용접부의 특성)

  • Han, Tae-Kyo;Kim, Seung-Jun;Lee, Bong-Keun;Kim, Dae-Up;Kang, Chung-Yun
    • Journal of Welding and Joining
    • /
    • v.24 no.1
    • /
    • pp.56-63
    • /
    • 2006
  • The characteristics of $CO_2$ or Nd:YAG laser welded 600MPa ade TRIP steel was investigated. He or Ar gas was used as a shield gas in case of $CO_2$ laser welding, but the shield gas was not used in case of Nd:YAG laser welding. Bead on plate welding was performed with various welding conditions. Defects in the joints of both welding type occurred at 1.8m/min but were not observed over the welding speed of 2.1m/min in case of Nd:YAG laser welding. However, porosity occurred in $CO_2$ laser welding and the tendency of decreasing with the increase of welding speed. The hardness was the highest at heat affected zone near fusion zone as well as at the fusion zone and decreased on approaching the base metal. In a perpendicular tensile test to the weld line, all specimens that have been welded at optimum conditions were fractured at the base metal, and the tensile properties showed the rather higher than those of raw material. In a parallel tensile test, the strength of the joints was higher than that of the base metal. Elongation was found to be lower than that of the raw material. Forming height by Erichsen test and elongation were deeply related with the ratio of base metal/weld metal and the maximum hardness of the weld metal. Also porosity induced to decrease the strength and the elongation. The maximum formability was recorded at approximately 80% as compared with that of the raw material with the optimum condition.

Construction of Hydrogeological Model for KURT Site Based on Geological Model (KURT 연구지역에서 지질모델을 이용한 수리지질모델의 구축)

  • Park, Kyung-Woo;Ko, Nak-Yeol;Ji, Sung-Hoon
    • Economic and Environmental Geology
    • /
    • v.51 no.2
    • /
    • pp.121-130
    • /
    • 2018
  • The KURT (KAERI Underground Research Tunnel) is a research tunnel which is located in KAERI (Korea Atomic Energy Research Institute) site. At KURT, researches on engineering and natural barrier system, which are the most important components for geological disposal system for high level radioactive waste, have been conducted. In this study, we synthesized the site characteristics obtained by various types of site investigation to introduce the geological model for KURT site, and induced the 3-D hydrogeological model for KURT site from the geological model. From the geological investigation at the surface and boreholes, four geological elements such as subsurface weathered zone, upper fractured rock, lower fractured rock and fracture zones were determined for the geological model. In addition, the geometries of these geological elements were also analyzed for the geological model to be three-dimensional. The results from 3-D geological model were used to construct the hydro-geological model for KURT site, which is one of the input data for groundwater flow modeling and safety assessment.