• Title/Summary/Keyword: fracture/fracture criteria

Search Result 333, Processing Time 0.028 seconds

Measurement of rock fracture toughness under mode I, II & mixed-mode conditions by using disc-typed specimens (인장, 전단 및 혼합모드에서 디스크 시험편을 이용한 암석의 파괴인성 측정에 관한 연구)

  • 장수호;이정인
    • Tunnel and Underground Space
    • /
    • v.9 no.4
    • /
    • pp.315-327
    • /
    • 1999
  • Rock fracture mechanics has been widely applied to blasting, hydraulic fracturing, rock slope and many other practical problems in rock engineering. But a measuring method for the fracture toughness of rock, one of the mort important parameters in fracture mechanics as an intrinsic property of rock, has not been yet well established. To obtain mode I rock fracture toughness, the more favorable disc-typed specimens such as CCNBD, SCB, chevron-notched SCB and BDT were used in this study. Rock fracture toughness under mixed-mode and mode II conditions was measured by using the STCA applied to the CCNBD specimen. Size effects such as specimen thickness, diameter and notch length on fracture toughness were investigated. From the mixed-mode results, fracture envelops were obtained by applying various regression curves. The mixed-mode results were also compared with three mixed-mode failure criteria. In each fracture toughness test, acoustic emission was measured to get the data for determining the load levels of different crack propagation patterns.

  • PDF

Comminuted Radial Head Fracture in All-arthroscopic Repair of Elbow Fracture-dislocation: Is Partial Excision of the Radial Head an Acceptable Treatment Option?

  • Yang, Hee Seok;Kim, Jeong Woo;Lee, Sung Hyun;Yoo, Byung Min
    • Clinics in Shoulder and Elbow
    • /
    • v.21 no.4
    • /
    • pp.234-239
    • /
    • 2018
  • Background: In elbow fracture-dislocation, partial excision of the comminuted radial head fracture that is not amenable to fixation remains controversial considering the accompanying symptoms. This study was undertaken to evaluate the results of radial head partial excision when the comminuted radial head fracture involved <50% of the articular surface in all-arthroscopic repair of elbow fracture-dislocation. Methods: Patients were divided into two groups based on the condition of the radial head fracture. In Group A, the patients had a radial head comminuted fracture involving <50% of the articular surface, and underwent arthroscopic partial excision. Group B was the non-excision group comprising patients with stable and non-displacement fractures. Follow-up consultations were conducted at 6 weeks and at 3, 6, 12, and 24 months after surgery. Results: In all, 19 patients (Group A: 11; Group B: 8) met the inclusion criteria and were enrolled in the study. At the final follow-up, all 19 patients showed complete resolution of elbow instability. No significant differences were observed in the range of motion, visual analogue scale score, and Mayo elbow performance score between groups. Radiological findings did not show any complications of the radiocapitellar joint. However, nonunion of the coracoid fracture was observed in 3 patients (Group A: 1; Group B: 2), without any accompanying instability and clinical symptoms. Conclusions: Considering that the final outcome is coronoid fracture fixation and lateral collateral ligament complex repair for restoring elbow stability, arthroscopic partial excision for radial head comminuted fractures involving <50% of articular surface is an effective and acceptable treatment for elbow fracture-dislocation.

Study on Design Parameter of Aluminum Micro V-notched Component with Thin Sheet Metal (알루미늄 박판 미세 V-notching 가공부위의 성형 Parameter 관한 연구)

  • Kim, S.M.;Park, J.W.;Lee, H.M.;Ku, T.W.;Kim, J.;Kang, B.S.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2008.10a
    • /
    • pp.249-252
    • /
    • 2008
  • Micro V-notching process has been used to manufacturing the safety component in Li-Ion battery. These kinds of safety component in Li-Ion battery plays an important role in the explosion from excessive overheating. Therefore, it is very crucial to estimate accurately the working pressure range of the safety component with micro V-notch. In this study, the relationship with the working internal pressure in Li-Ion battery and fracture phenomenon in micro V-notch was investigated through the numerical analysis. The numerical analysis is especially adopted the finite element method with ductile fracture criteria.

  • PDF

Analysis of Risk Factors for Infection in Orthopedic Trauma Patients

  • Moon, Gi Ho;Cho, Jae-Woo;Kim, Beom Soo;Yeo, Do Hyun;Oh, Jong-Keon
    • Journal of Trauma and Injury
    • /
    • v.32 no.1
    • /
    • pp.40-46
    • /
    • 2019
  • Purpose: We perform an analysis of infection risk factors for fracture patients and confirm that the risk factors reported in previous studies increase the risk of actual infection among fractured patients. In addition, injury severity score (ISS) which is used as an evaluation tool for morbidity of trauma patients, confirms whether there is a relationship with infection after orthopedic fracture surgery. Methods: We retrospectively reviewed 1,818 patients who underwent fixation surgery at orthopedic trauma team, focused trauma center from January 1, 2015 to December 31, 2017. Thirty-five patients were infected after fracture surgery. We analyzed age, sex, open fracture criteria based on Gustilo-Aderson classification 3b, anatomical location (upper extremity or lower extremity) of fracture, diabetes, smoking, ISS. Results: Of 1,818 patients, 35 (1.9%) were diagnosed with postoperative infection. Of the 35 infected patients, nine (25.7%) were female and five (14.0%) were upper extremity fractures. Three (8.6%) were diagnosed with diabetes and eight (22.8%) were smokers. Thirteen (37.1%) had ISS less than nine points and six (17.1%) had ISS 15 points or more. Of 1,818 patients, 80 had open fractures. Surgical site infection were diagnosed in 12 (15.0%) of 80. And nine of 12 were checked with Gustilo-Aderson classification 3b or more. Linear logistic regression analysis was performed using statistical analysis program Stata 15 (Stata Corporation, College Station, TX, USA). In addition, independent variables were logistic regression analyzed individually after Propensity scores matching. In all statistical analyzes, only open fracture was identified as a risk factor. Conclusions: The risk factors for infection in fracture patients were found to be significantly influenced by open fracture rather than the underlying disease or anatomical feature of the patient. In the case of ISS, it is considered that there is a limitation. It is necessary to develop a new scoring system that can appropriately approach the morbidity of fracture trauma patients.

Fatigue Life Evaluation of Butt-Welded Tubular Joints

  • Kim, Dong-Su;Nho, In-Sik
    • Journal of Ocean Engineering and Technology
    • /
    • v.17 no.2
    • /
    • pp.34-39
    • /
    • 2003
  • Recent deepwater offshore structures in the Gulf of Mexico utilize butt welded tubular joints. Application of a welded tubular joint includes tendons, production risers, and steel catenary risers. Fatigue life assessment of these joints becomes more critical, as the structures to which they are attached are allowed to undergo cyclic and sometimes large displacements around an anchored position. Estimation of the fatigue behavior of these tubular members in the design stage is generally condrcted by using S-N curves, as specified in the codeds and standards. Applying the stress concentration factor of the welded structure to the S-N approach often results in a very conservative assessment, because the stress field acting on the tubular has a non-uniform distribution through the thickness. Fatigue life analysis using fracture mechanics has been applied in the design of the catenary risers. This technology enables the engineer to establish proper requirements on weld quality and inspection acceptance criteria to assure satisfactory structural integrity during its design life. It also provides guidance on proper design curves and a methodology for accounting for the effects of non-uniform stress distribution through the wall thickness. Still, there is inconsistency when designing tubular joints using a conventional S-N approach and when specifying weld flaw acceptance criteria using fracture mechanics approach. This study developed fatigue curves that are consistent with both the S-N approach and the fracture mechanics approach. Accounting for non-uniform stress distribution and threshold stress intensity factor were key parameters in relating both approaches. A series of S-N curves, generated from the fracture mechanics approach, were compared to the existing S-N curves. For flat plate butt joint, the S-N curve generated from fracture mechanics matches with the IIW class 100 curve when initial crack depth was 0.5 mm (0.02 ). The new curves for tubular joint agree very well with the experimental results. The comparison also indicated the degree of conservatism built into the API X design curve.

Finite Element Based Multi-Scale Ductile Failure Simulation of Full-Scale Pipes with a Circumferential Crack in a Low Carbon Steel (유한요소기반 다중스케일 연성파손모사 기법을 이용한 원주방향 균열이 존재하는 탄소강 실배관의 파손예측 및 검증)

  • Han, Jae-Jun;Bae, Kyung-Dong;Kim, Yun-Jae;Kim, Jong-Hyun;Kim, Nak-Hyun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.7
    • /
    • pp.727-734
    • /
    • 2014
  • This paper describes multi-scale based ductile fracture simulation using finite element (FE) damage analysis. The maximum and crack initiation loads of cracked components were predicted using proposed virtual testing method. To apply the local approach criteria for ductile fracture, stress-modified fracture strain model was adopted as the damage criteria with modified calibration technique that only requires tensile and fracture toughness test data. Element-size-dependent critical damage model is also introduced to apply the proposed ductile fracture simulation to large-scale components. The results of the simulation were compared with those of the tests on SA333 Gr. 6 full-scale pipes at $288^{\circ}C$, performed by the Battelle Memorial Institute.

Fatigue Life Evaluation of Butt-Welded Tubular Joints

  • Kim, Dong-Sup;Nho, In-Sik
    • International Journal of Ocean Engineering and Technology Speciallssue:Selected Papers
    • /
    • v.6 no.1
    • /
    • pp.69-74
    • /
    • 2003
  • Recent deepwater offshore structures in the Gulf of Mexico utilize butt welded tubular joints. Application of a welded tubular joint includes tendons, production risers, and steel catenary risers. Fatigue life assessment of these joints becomes more critical, as the structures to which they are attached are allowed to undergo cyclic and sometimes large displacements around an anchored position. Estimation of the fatigue behavior of these tubular members in the design stage is generally conducted by using S-N curves, as specified in the codes and standards. Applying the stress concentration factor of the welded structure to the S-N approach often results in a very conservative assessment, because the stress field acting on the tubular has a non-uniform distribution through the thickness. Fatigue life analysis using fracture mechanics has been applied in the design of the catenary risers. This technology enables the engineer to establish proper requirements on weld quality and inspection acceptance criteria to assure satisfactory structural integrity during its design life. It also provides guidance on proper design curves and a methodology for accounting for the effects of non-uniform stress distribution through the wall thickness. Still, there is inconsistency when designing tubular joints using a conventional S-N approach and when specifying weld flaw acceptance criteria using fracture mechanics approach. This study developed fatigue curves that are consistent with both the S-N approach and the fracture mechanics approach. Accounting for non-uniform stress distribution and threshold stress intensity factor were key parameters in relating both approaches. A series of S-N curves, generated from the fracture mechanics approach, were compared to the existing S-N curves. For flat plate butt joint, the S-N curve generated from fracture mechanics matches with the IIW class 100 curve when initial crack depth was 0.5 mm (0.02). The new curves for tubular joint agree very well with the experimental results. The comparison also indicated the degree of conservatism built into the API X design curve.

  • PDF

Limited internal fixation for the treatment of the Ovadia and Beals type II or III Pilon fracture (Ovadia와 Beals 제2형 또는 3형 경골 천정 골절의 제한적 내고정술을 이용한 치료)

  • Kim, Hyoung-Chun;Kim, Kwang-Yul;Lim, Mun-Sup;Kim, Jin-Hyoung;Kwon, Joon-Hyoung
    • Journal of Korean Foot and Ankle Society
    • /
    • v.7 no.2
    • /
    • pp.250-257
    • /
    • 2003
  • Purpose: Pilon fracture is caused by high energy and axial compression forces, and it is often associated with severe comminution and soft tissue injury. Recently, limited internal fixation of this fracture may avoid the soft tissue complications associated with formal open reduction and internal fixation and avoid incongruity of joint margin associated with conservative treatment. We have treated Ovadia and Beals type II or III pilon fracture with limited internal fixation and the results were satisfactory. Materials and Methods: We analyzed 15 cases of Ovadia and Beals type II or III fractures who were treated by limited internal fixation(K-wire or screw fixation) from January 1995 to December 2000. The average follow up period was 20 months(range, 12 to 38 months). According to the Ovadia and Beals classification, seven cases were type II, and eight cases were type III. Radiographic results were assessed by Ovadia and Beals criteria. We also assessed the functional results by Mast and Teipner criteria. Results: Radiographic results showed good in 67% and fair in 33% of cases. Clinical results showed good in 73% and fair in 27% of cases. There were no complications such as wound infection and skin necrosis, but traumatic arthritis were 2 cases. Conclusion: Pilon fractures are high energy injuries with significantly associated soft tissue damage and traumatic arthritis. Limited internal fixation offers good solution to Ovadia and Beals type II or III fracture.

  • PDF

TRAUMATIC TMJ INJURY (외상성 악관절 손상)

  • Kim, Young-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.19 no.2
    • /
    • pp.191-199
    • /
    • 1997
  • Mandibular trauma is developed due to traffic accident, fall down, industrial injury, and others. TMJ disorder is usually also developed after facial traumatic injury. Many authors suggested that disc displacement or tearing, acute synovitis, TMJ ankylosis, traumatic arthritis, or effusion are developed after facial trauma. It is still very controversible what is the best treatment of TMJ injury such as condylar fracture and meniscal injury. In TMJ injury, synovial inflammation is developed and pain mediators such as prostaglandin E2 or leukotriene B4 are released from the synovial membrane. This can be a cause of TMJ disorder. I present a variety of experimental study about the condylar fracture and meniscal injury and enzyme-immunoassay of synovial fluid after mandibular trauma that have been studied since 1992 and establish the treatment criteria of traumatic TMJ injury. I think that the treatment option of condylar fracture depends upon the surgeon's criteria exclusively. There are no significant differences between conservative and surgical treatment. If the aggressive functional physical therapy and long-term followup be performed, the favorable functional recovery of TMJ can be obtained. And I think that the initial surgical management of meniscus of TMJ is unnecessary in condylar fracture. And also arthrocentesis can be available to release the patient's subjective symptoms and improve the healing of injured TMJ.

  • PDF

Evaluation of Adhesive Properties Using Cohesive Zone Model : Mode I (Cohesive Zone Model을 이용한 접착제 물성평가 : 모드 I)

  • Lee, Chan-Joo;Lee, Sang-Kon;Ko, Dae-Cheol;Kim, Byung-Min
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.5
    • /
    • pp.474-481
    • /
    • 2009
  • Fracture models and criteria of adhesive with two parameters, namely $G_C$ and ${\sigma}_{max}$, have been developed to describe the fracture process of adhesive joints. Cohesive zone model(CZM) is a representative two parameter failure criteria approach. In CZM, ${\sigma}_{max}$ is a critical, limiting maximum value of the stress in the damage zone ahead of the crack and is assumed to have some physical significance in adhesive failure. Based on CZM and finite element analysis method, the relationship between fracture load and adhesive properties, as $G_{IC)$ and $({\sigma}_{max})_I$, was investigated in adhesively bonded joint tensile test and T-peel test. The two parameters in tensile mode loading were evaluated by using the relationship. The value of $G_{\IC}$ evaluated by proposed method showed close agreement with analytical solution for tapered double cantilever beam(TDCB) test which proposed in an ASTM standard.