• Title/Summary/Keyword: foundation soil properties

Search Result 163, Processing Time 0.02 seconds

Characteristics of Vertical Stress Distribution in Sandy Soil According to the Relative Compaction and Composition of the Soil Layer (사질토 지반의 상대다짐도 및 토층에 따른 연직지중응력 분포 특성)

  • Nam, Hyo-Seok;Lee, Sang-Ho
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.52 no.2
    • /
    • pp.43-50
    • /
    • 2010
  • This study was carried out to evaluate the vertical stress properties in sandy soil according to changes of foundation condition in soil bin compacted three layers. The following conclusions and comparisons have been made based on careful analysis from theoretical and experimental methods. : When sandy soil subjected to circular uniform load, the vertical stress increments ($\Delta\sigma_z$) was increased as load increasing, the maximum values of $\Delta\sigma_z$ was achieved at the point loading axis, and $\Delta\sigma_z$ was not shown over at a distance of three times of loading plate width (B). The vertical stress increments were achieved largely at 80 % relative compaction (Rc) compared to 95 % relative compaction due to stress concentration in sandy soil. When sandy soil subjected to circular uniform load, the $\Delta\sigma_z$ differences between theoretical and experimental values as load increased were more increased and its maximum differences were achieved at stress axis. When gravel surface macadamized over sandy soil subjected to load, the $\Delta\sigma_z$ was concentrated to load axis as load increasing, so that macadamization will be decreased load transmission.

Wave Propagation Analysis of a Strip Foundation in Layered Soils using Infinite Elements (무한요소를 사용한 층상지반에 놓인 스트립기초의 진동전파해석)

  • 윤정방;김두기;김유진;박종찬
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1996.10a
    • /
    • pp.202-209
    • /
    • 1996
  • In this paper, two dimensional vertical and comer infinite elements which can include multiple wave components to model underlying half space are developed. These elements are natural and economical to model underlying stiff half space or rock. To verify the behavior of these infinite elements, vertical, horizontal, and rocking compliances of a rigid strip foundation on a viscoelastic soil profile are analyzed and compared with those of Tzong and Penzien who used the boundary solution method. Good agreements are noticed between the two methods. The influence of material properties like Poisson's ratio, material damping, and stiffness ratio of layers as well as the influence of geometrical properties such as layer thicknesses and depth of foundation embedment are studied. Example analysis is carried out for the shaking table which is located in KIMM(Korea Institute of Machinery and Materials), and the vertical and horizontal displacements of the analysis are compared with the measured, and show good results and demonstrate the efficiency of the proposed method.

  • PDF

The Evaluation of the Allowable Bearing Capacity of Foundations using N-Value (N-Value를 이용한 기초의 지지력 산정)

  • 이강운;박택규;정해운
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.10a
    • /
    • pp.281-292
    • /
    • 2001
  • The evaluation of the allowable bearing capacity is the most important step in the design of a foundation. An accurate evaluation of the effect of all factors such as the physical properties of the soil located beneath the area, the size of the area, the depth of foundation, and the position of the water table is impracticable Therefore, the designer is compelled to estimate the allowable bearing capacity on the basis of simple semiempirical rules under cohesionless soils. This paper deals with semiemperical rules for determining allowable bearing capacity based on observed relations between the results of standard penetration test. Additional comparisions between the results of the theoretical methods and the emperical rules are performed to suggest more conservative design for the engineer.

  • PDF

Effect of domestic sewage on macro-micro physical and mechanical properties of soil

  • Zhi-Fei Li;Wei Liu;Yu-Ao Li;Yi Li;Shu-Chang Zhang;Yin-Lei Sun
    • Structural Monitoring and Maintenance
    • /
    • v.11 no.3
    • /
    • pp.247-262
    • /
    • 2024
  • Domestic sewage can greatly affect the macro-micro physical-mechanical properties of building foundation soils. In order to investigate the effect of domestic sewage on physical and mechanical properties of soils, the physicochemical properties of three groups of different concentrations of domestic sewage contaminated soil were tested through indoor experiments. Combined with scanning electron microscopy, X-ray diffraction experiments, and grey relational analysis, the degree of influence of different concentrations of domestic sewage on the physicochemical properties of soil was compared and analyzed from multiple perspectives such as microstructure and mineral composition, revealing the influencing mechanism of soil pollution by domestic sewage. The results showed that under the immersion of contaminated water, the color of the soaking water turned black first and then yellow, and brownish yellow secretions appeared on the surface of the soil samples. The moisture content, specific gravity, density, and pore ratio index of the soil samples immersed in 50% and 100% domestic sewage decreased with the increase of sewage concentration, while the liquid limit of the soil samples changed in the opposite direction. The immersion time had little effect on the slope of the compression curve of the soil samples soaked in tap water. For the soil samples immersed in domestic sewage, the slope of the compression curve and the compression coefficient increased with the increase of domestic sewage concentration and immersion time, while the compression modulus showed the opposite trend. In the soil samples immersed in tap water, there were a large number of small particles and cementitious substances, and the structure was relatively dense. With the increase of domestic sewage concentration, the microstructure of the soil changed significantly, with the appearance of sigle particle structure, loose and disorderly arrangement of particles, increased and enlarged pores, gradual reduction of small particle substances and cementitious substances, and the soil structure transformed from compact to loose. The research findings can provide theoretical reference for contaminated geotechnical engineering.

Effectiveness of Reinforcement by Geogrid & Pile in Soft Clay (지오그리드와 말뚝에 의한 연약지반 보강효과)

  • 신은철;이상혁;이명원
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.09a
    • /
    • pp.61-69
    • /
    • 2000
  • It is not easy to find a good soil condition due to the shortage of suitable land for construction work. The earth structure and buildings can be constructed over the soft soil. The soft soil must be treated either using the reinforcement element or dewatering. Most of land reclamation projects are being implemented along the south coast or west coast of the Korean Peninsula. The soils in these areas are covered with the soft marine clay, so soil and site improvement is the most important things to do. Pile foundation at the bottom of embankment can be constructed either in the soft ground or in the soil contaminated area. The purpose of this research is to develop "geogrid-reinforced piled embankment method" to prevent the differential settlement and increase the bearing capacity of soil. In this study, the effectiveness of the geogrid-reinforcement was studied by varying the space between piles and reinforcement conditions. Also, the geotechnical engineering properties of the embankment material and foundation soil were determined through the laboratory tests as well as the field tests. As a result, the site that the pile-spacing S = 3b with geogrid reinforcement is the most effective to reduce the differential settlement and increase load bearing capacity.

  • PDF

Investigation of linear and nonlinear of behaviours of reinforced concrete cantilever retaining walls according to the earthquake loads considering soil-structures interactions

  • Gursoy, Senol;Durmus, Ahmet
    • Structural Engineering and Mechanics
    • /
    • v.31 no.1
    • /
    • pp.75-91
    • /
    • 2009
  • It is known that retaining walls were severely damaged as well in the most recent earthquakes having occurred in the countries in the active seismic belts of the world. This damage can be ascribed to the calculation methods used for the designs of retaining walls in the event of their constructions and employment having been accurately carried out. Generally simplified pseudo-static methods are used in the analysis of retaining walls with analytical methods and soil-structure interaction are not considered. In view of these circumstances, in this article by taking soil interaction into consideration, linear and nonlinear behaviours of retaining walls are analyzed with the assistance of LUSAS which is one of the structural analysis programs. This investigations are carried out per LUSAS which employs the finite element method as to the Erzincan (1992) Earthquake North-South component and the obtained findings are compared with the ones obtained from the method suggested in Eurocode-8, which is still effective today, and Mononobe-Okabe method. Not only do the obtained results indicate the distribution and magnitude of soil pressures are depend on the filling soil but on the foundation soil as well and nonlinear effects should be considered in designs of these walls.

Soil Chemical Properties of Reclaimed Tide Lands Under Government Management in Korea: Results of 4-years monitoring (한국의 국가관리 간척지 토양의 화학성 변동: 4년 모니터링 결과)

  • Ryu, Jin-Hee;Lee, Su-Hwan;Oh, Yang-Yeol;Lee, Jeong-Tae
    • Korean Journal of Environmental Agriculture
    • /
    • v.38 no.4
    • /
    • pp.273-280
    • /
    • 2019
  • BACKGROUND: The reclaimed lands for agricultural use managed by the Korean government is consisted of 17,145 hectares of lands under construction and 13,384 hectares of completed lands. In order to utilize these reclaimed lands as competitive agricultural complexes, the government is preparing to develop comprehensive development plans for multiple purposes. For rational land-use planning and soil management, information of the soil chemical properties is necessary. METHODS AND RESULTS: From 2013 to 2016, soil samples were collected from 85 representative sampling sites of the reclaimed lands and analyzed for soil chemical properties including electric conductivity (EC), pH, soil organic matter (SOM), and nutrients. The annual mean soil EC ranged from 5.1 to 8.3 dS m-1 and have continued to decrease over the years (estimation equation with EC as dependent and year as independent variable was y =0.0736x2 - 1.4985x + 9.8305, R2 = 0.9753). The pH ranged from 7.3 to 7.6, which was higher than the optimum range (5.5~7.0) for agricultural soils. Soil organic matter (8 to 11 g kg-1) was lower level than the optimum range (20~30 kg-1). Available silicate (Av.SiO2) ranged from 169 to 229 mg kg-1, which was close to the minimum content (≥157 mg kg-1) for rice paddy field. Available phosphate (Av.P2O5) content (24~39 mg kg-1) was lower than the optimum range (80~120 mg kg-1) for rice paddy field. CONCLUSION: For efficient agricultural use of reclaimed lands under government management, our results suggest that the application of organic matter and supplying deficient nutrients as well as desalinization is required.

Stabilization of cement-soil utilizing microbially induced carbonate precipitation

  • Shuang Li;Ming Huang;Mingjuan Cui;Peng Lin;Liudi Xu;Kai Xu
    • Geomechanics and Engineering
    • /
    • v.35 no.1
    • /
    • pp.95-108
    • /
    • 2023
  • Soft soil ground is a crucial factor limiting the development of the construction of transportation infrastructure in coastal areas. Soft soil is characterized by low strength, low permeability and high compressibility. However, the ordinary treatment method uses Portland cement to solidify the soft soil, which has low early strength and requires a long curing time. Microbially induced carbonate precipitation (MICP) is an emerging method to address geo-environmental problems associated with geotechnical materials. In this study, a method of bio-cementitious mortars consisting of MICP and cement was proposed to stabilize the soft soil. A series of laboratory tests were conducted on MICP-treated and cement-MICP-treated (C-MICP-treated) soft soils to improve mechanical properties. Microscale observations were also undertaken to reveal the underlying mechanism of cement-soil treated by MICP. The results showed that cohesion and internal friction angles of MICP-treated soft soil were greater than those of remolded soft soil. The UCS, elastic modulus and toughness of C-MICP-treated soft soil with high moisture content (50%, 60%, 70%, 80%) were improved compared to traditional cement-soil. A remarkable difference was observed that the MICP process mainly played a role in the early curing stage (i.e., within 14 days) while cement hydration continued during the whole process. Micro-characterization revealed that the calcium carbonate filling the pores enhanced the soft soil.

Seismic Response of Structure on Flexible Foundation (유연한 기초 위에 세워진 구조물의 지진거동)

  • 김용석
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.1 no.1
    • /
    • pp.11-17
    • /
    • 1997
  • Seismic analyses of structures were carried out in the past assuming a right base and Ignoring the characteristics of foundations and the properties of the underlying soil. Resent soil-structure interaction studies show that seismic response of structure can be affected significantly by these fators. Typical effects of the soil-structure interaction are the kinematic interaction of a rigid massiess foundation and the inertial interaction between underlying soil and structure. The kinematic interaction effect is particularly important for embedded foundations and can be ignored for surface foundations with vertically propagating waves. In this study, seismic response of structure was investigated with four buildings in Mexico City considering only the inertial interaction effect and using the E-W components of the 1985 Mexico City earthquake records. The study was carried out for surface foundations and pile foundations with linear and nonlinear soil conditions, comparing the results with those of the rigid base.

  • PDF

Seismic Responses of Wall-Slab Apartment Building Structures Built on the Soft Soil Layer Considering the Stiffnesses of a Foundation-Soil System (연약지반의 기초지반강성을 고려한 벽식구조 아파트의 지진응답)

  • 김지원;김용석
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.3
    • /
    • pp.19-27
    • /
    • 2001
  • In this seismic analyses of structures, it is well recognized that the effects of soil-structure interaction can not be ignored and seismic responses of a structure taking into account the stiffnesses of a foundation-soil system show the significant difference from those with a rigid base. However, current seismic analyses of apartment building structures were carried out with the rigid base ignoring the characteristics of the foundation and the properties of the underlying soil. In this study, seismic analyses of wall-slob type apartment buildings which have a particular structural type were carried out taking into account the soft soil layer comparing seismic response spectra of a flexible base with those of a rigid base and UBC-97. Low-rise or middle height wall-slab type apartment buildings built on the deep soft soil layer showed a rigid body motion with the reduced seismic responses due to the base isolation effect, indicating that it is considerably safe but uneconomical to utilize the design spectra of UB-97 for the seismic design of wall-slab type apartment buildings due to conservative design.

  • PDF