• 제목/요약/키워드: foundation height

검색결과 213건 처리시간 0.023초

3D Scanner를 이용한 foundation 착용시의 인체 변화 계측 (Body Shape Variations Measurements with 3D Scanner for Wearing Foundation)

  • 박지은;김희은
    • 한국의류산업학회지
    • /
    • 제9권6호
    • /
    • pp.651-657
    • /
    • 2007
  • This study was carried out to analyse body configuration and to observe any space between skin and foundation. A special 3D scanner was used to analyze this foundation. Experimental foundations were brassiere, girdle, and all-in-one. Four subjects volunteered, each subject was scanned while wearing foundation and not wearing foundation. Body shape variations were analyzed with an Auto CAD and ScanWax program which analyzes cross section of the skin surface to look for any changes. Height was increased all parts of body, circumference was increased in breast and bust while wearing the foundation. The hip thickness was not increased with wearing the foundation. Therefore this foundation makes people have a different appearance due to unexpected body shape variations. The effects of this foundation should be classified by observing height, circumference, and thickness changes in the body.

The dynamic response of adjacent structures with the shallow foundation of different height and distance on liquefiable saturated sand

  • Jilei Hu;Luoyan Wang;Wenxiang Shen;Fengjun Wei;Rendong Guo;Jing Wang
    • Earthquakes and Structures
    • /
    • 제25권2호
    • /
    • pp.135-148
    • /
    • 2023
  • The structure-soil-structure interaction (SSSI) effect in adjacent structures may affect the liquefaction-induced damage of shallow foundation structures. The existing studies only analysed the independent effects on the structural dynamic response but ignored the coupling effect of height difference and distance of adjacent structures (F) on liquefied foundations on the dynamic response. Therefore, this paper adopts finite element and finite difference coupled dynamic analysis method to discuss the effect of the F on the seismic response of shallow foundation structures. The results show that the effect of the short structure on the acceleration response of the tall structure can be neglected as F increases when the height difference reaches 2 times the height of the short structure. The beneficial effect of SSSI on short structures is weakened under strong seismic excitations, and the effect of the increase of F on the settlement ratio gradually decreases, which causes a larger rotation hazard. When the distance is smaller than the foundation width, the short structure will exceed the rotation critical value and cause structural damage. When the distance is larger than the foundation width, the rotation angle is within the safe range (0.02 rad).

불균일단면교각 주위의 사석 세굴 보호공 (Riprap Scour Countermeasures around Nonuniform Bridge Piers)

  • 윤태훈;박기두
    • 한국수자원학회논문집
    • /
    • 제33권4호
    • /
    • pp.385-392
    • /
    • 2000
  • 교각과 기초로 구성되는 불균일단면교각 주위의 사석보호공의 거동에 관련된 인자들의 영향에 관한 실험결과가 기술된다. 불균일단면교각은 교각의 전 길이에 대한 단면이 일정하지 않고 직경 bp의 원주가 보다 큰 직경 bf인 기초에 설치된 구조이다. 사석보호공의 안정은 기초의 높이에 따라 크게 영향을 받으며 한계기초높이, Zc가 존재함이 밝혀졌다. 한계기초높이는 균일단면교각의 한계유속과 같은 한계유속을 갖는 불균일단면교각의 기초높이로 정의되고 실험결과 Zc=0.8bf로 밝혀진다. 기초높이가 Zc보다 작으면 기초의 상류연장으로 작용하여 사석보호공은 더 안정하게 되고, 기초높이가 Zc보다 크게 되면 기초는 단면이 증대된 교각으로 작용하고 기초 자체의 하강류로 인하여 사석보호공은 불안정하게 되어 쉽게 움직이게 된다. 기초상단면적의 영향과 불균일단면교각의 사석보호공의 크기 결정방법이 또한 기술된다.

  • PDF

전통주거안채의 정면비례체계에 관한 연구 - 전남지방 중.상류 주택을 중심으로 - (A Study on the Front Elevation Proportion System in Traditional Housing 'An-Chae' - Focused on the Middle-High Classes' Housing in Jeonnam District -)

  • 박지민;천득염
    • 건축역사연구
    • /
    • 제14권4호
    • /
    • pp.73-86
    • /
    • 2005
  • The purpose of this study is to prove the correlations among various factors what determined to formation of front elevation proportion system through making an actual survey and investigating. According to the analysis of them, we make conclusions as follows; 1, On the assumption that average distance of 1Kan(間) is 1, the height of foundation is 0.21, the height of floor from foundation is 0.24, the height of normal column from floor is 0.85, the height of eaves from foundation is 1.10. 2. Southeast faced buildings are wider than southwest faced buildings in the distance of 1Kan (間) in the range of $110{sim}220mm$. The height of foundation and floor in the southeast faced buildings are higher than those in southwest faced buildings beside the height of normal column, eaves, high column in the southwest faced buildings are higher than those in southeast faced buildings. 3. As number of front Kan(間) increases, the distance of 1Kan(間) decrease and the height of eaves and high column(高柱) increases. This is cause of making a maximum needed inner space by increasing the distance of 1Kan(間). This is an wisdom for living from ancestors. 4. As number of Dori(道里) increases, the distances of 1Kan are nearly same but the height of eaves and high column(高柱) increases about 300mm, This is a natural result from an increasing of building scale. 5. The distance of 1Kan(間) in later 19C building is most wide but, the unit heights are minimal average values at year 1900 as a reference mark. After this, the height of normal column, eaves, high column are higher about $170{sim}330mm$. 6. The number of Kan in front elevation, Dori(道里), and direction of building have correlations each other in proportion system of traditional housing An-Chae with significant level, p<0.05.

  • PDF

Effect of Pasternak foundation: Structural modal identification for vibration of FG shell

  • Hussain, Muzamal;Selmi, Abdellatif
    • Advances in concrete construction
    • /
    • 제9권6호
    • /
    • pp.569-576
    • /
    • 2020
  • Employment of the wave propagation approach with the combination of Pasternak foundation equation gives birth to the shell frequency equation. Mathematically, the integral form of the Lagrange energy functional is converted into a set of three partial differential equations. A cylindrical shell is placed on the elastic foundation of Pasternak. For isotropic materials, the physical properties are same everywhere, whereas the laminated and functionally graded materials, they vary from point to point. Here the shell material has been taken as functionally graded material. The influence of the elastic foundation, wave number, length and height-to-radius ratios is investigated with different boundary conditions. The frequencies of length-to-radius and height-to-radius ratio are counter part of each other. The frequency first increases and gain maximum value in the midway of the shell length and then lowers down for the variations of wave number. It is found that due to inducting the elastic foundation of Pasternak, the frequencies increases. It is also exhibited that the effect of frequencies is investigated by varying the surfaces with stainless steel and nickel as a constituent material. MATLAB software is utilized for the vibration of functionally graded cylindrical shell with elastic foundation of Pasternak and the results are verified with the open literature.

Soil and structure uncertainty effects on the Soil Foundation Structure dynamic response

  • Guellil, Mohamed Elhebib;Harichane, Zamila;Berkane, Hakima Djilali;Sadouk, Amina
    • Earthquakes and Structures
    • /
    • 제12권2호
    • /
    • pp.153-163
    • /
    • 2017
  • The underlying goal of the present paper is to investigate soil and structural uncertainties on impedance functions and structural response of soil-shallow foundation-structure (SSFS) system using Monte Carlo simulations. The impedance functions of a rigid massless circular foundation resting on the surface of a random soil layer underlain by a homogeneous half-space are obtained using 1-D wave propagation in cones with reflection and refraction occurring at the layer-basement interface and free surface. Firstly, two distribution functions (lognormal and gamma) were used to generate random numbers of soil parameters (layer's thickness and shear wave velocity) for both horizontal and rocking modes of vibration with coefficients of variation ranging between 5 and 20%, for each distribution and each parameter. Secondly, the influence of uncertainties of soil parameters (layer's thickness, and shear wave velocity), as well as structural parameters (height of the superstructure, and radius of the foundation) on the response of the coupled system using lognormal distribution was investigated. This study illustrated that uncertainties on soil and structure properties, especially shear wave velocity and thickness of the layer, height of the structure and the foundation radius significantly affect the impedance functions, and in same time the response of the coupled system.

Evaluation of Dynamic Properties of Trackbed Foundation Soil Using Mid-size Resonant Column Test

  • Lim, Yujin;Nguyen, Tien Hue;Lee, Seong Hyeok;Lee, Jin-Wook
    • International Journal of Railway
    • /
    • 제6권3호
    • /
    • pp.112-119
    • /
    • 2013
  • A mid-size RC test apparatus (MRCA) equipped with a program is developed that can test samples up to D=10 cm diameter and H=20 cm height which are larger than usual samples used in practice. Using the developed RC test apparatus, two types of crushed trackbed foundation materials were tested in order to get the shear modulus reduction curves of the materials with changing of shear strain levels. For comparison purpose, large repetitive triaxial compression tests (LRT) with samples of height H=60cm and diameter D=30 cm were performed also. Resilient modulus obtained from the LRT was converted to shear modulus by considering elastic theory and strain level conversion and were compared to shear modulus values from the MRCA. It is found from this study that the MRCA can be used to test the trackbed foundation materials properly. It is found also that strain levels of $E_{v2}$ mostly used in the field should be verified considering the shear modulus reduction curves and proper values of $E_{v2}$ of trackbed foundation must be used considering the strain level verified.

대심도 부산점토에 적용된 종저말뚝(Belled Shaft foundation)의 수치해석 연구 (Numerical Analysis of Belled Shaft Foundation in Thick Pusan Clays)

  • Rao, K.G.
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.530-535
    • /
    • 2006
  • The Pusan clays are soft and thick deposits and in some places, they reach even up to 50-70m. So, the pile foundations are inevitable in almost all cases. But they are significantly expansive when the length of the pile reaches about 70m. In this study, a comprehensive parametric study has been carried out in order to reduce the pile length and number of piles required in turn the cost of the foundation for particular building. A belled shaft pile has been optimized for a typical soil profile using the PLAXIS (FEM code). These results have shown a new direction of the pile foundation in Pusan, Korea. The results including the variation of contact pressures at the bottom of the bell, optimization of the angle of the bell and height of the bell in terms of the diameter of the shaft. And also, the design curves have been generated so that they can be directly used for design of belled shaft foundations. However, the structural strength criterion is being checked in the concerned laboratory.

  • PDF

수변 공원녹지의 마운딩 유형 및 규모산정 연구 (A Study of Mounding Classification Analysis & Scale Calculation in Waterside Parks and Green Areas)

  • 안병철;반권수
    • 한국환경복원기술학회지
    • /
    • 제20권4호
    • /
    • pp.77-87
    • /
    • 2017
  • In this study, we investigated the physical form of planting foundation of the parks and green spaces in the waterside of Korea and classified them into groups showing common features. It was clssified into 7 kinds of parks and green spaces of 27 waterside parks in Korea including landscape, ecology, art, shields, site boundaries, windbreaks, and soundproofing. As a result, the study was carried out on the detailed type and size estimation through the sampling survey of planting foundation of landscape and ecological type mounding which can be statistically analyzed. Landscape and ecological mounding have the characteristics of securing the ecological stability of the waterside planting areas and the diversity of planting landscape. It is possible to create a green landscape through various terrain changes such as enclosing, focusing, and panoramic view. The physical characteristics of ecological and landscape type mounding can be expressed as height, width, and length And physical data can appear in various forms and sizes depending on the purpose and function of the buffer effect of the land use in the waterside planting areas, the landscape creation, the ecological buffer. In this study, the range of the physical scale for landscape and ecological mounding of waterside parks and green spaces was calculated. The range of the mounding height was analyzed to be less than 1.25m and more than 1.25m and the average height was 0.74~1.08m and 1.75~2.75m respectively. In addition, the range of width of mounding was less than 6.13m, 6.13~17.5m, and more than 17.5m, and the average width of each was 3.45~4.95m, 7.05~10.85m and 31.54~51.54m respectively. The range for the length of mounding was less than 50m, 50~500m, and more than 500m. The mean length of each mounding was 34.0m, 116.3m and 955.8m. It is difficult to distinguish the difference between the waterside planting areas and the urban greenery in the purpose and function of landscape and ecological mounding. However, considering the average distance of 60m from the waterside and the average height of 1.26m, we can conclud that opened planting foundation is prefered to high mounding designs in waterside planting areas. It is expected that the results presented for the improvement of the logical and spatial value of the waterside parks and green areas planting foundation design can be served as the basic data helpful for practical application in landscape architecture planning and design.

점토지반에 근입된 송전철탑 연결형 말뚝기초의 저항력증가계수 (Resistance Increasing Factor of Connected-pile Foundation for Transmission Tower in Clay)

  • 경두현;이준환;백규호;김대홍
    • 한국지반공학회논문집
    • /
    • 제28권8호
    • /
    • pp.31-41
    • /
    • 2012
  • 연약지반에 건설되는 송전철탑 말뚝기초는 부등침하로 인한 철탑구조체의 손상을 유발 할 수 있다. 이에 따라 일본과 미국에서는 철탑을 지지하는 각 기초부를 연결보로 연결한 연결형기초의 사용을 추천하고 있다(TEPCO 1988, IEEE 2001). 연결형 말뚝기초의 저항력증가계수는 연결체의 영향으로 인하여 증가되는 연결형 말뚝기초의 저항력의 증가량을 나타낸다. 본 연구에서는 점토지반에 근입된 송전철탑 연결형말뚝 기초의 모형수평재하시험을 수행하여 연결형 말뚝기초의 저항력증가계수를 도출하였다. 본 시험은 실트질 점토지반에서 수행되었으며, 수평하중의 재하높이와 재하각도, 말뚝기초를 연결하는 연결체의 강성을 변화시켜 다양한 조건상에서의 저항력 증가계수를 도출하였다. 본 연구에서 도출된 저항력 증가계수는 송전철탑의 하중작용높이와 기초를 연결하는 연결체의 강성에 대한 함수로 나타났으며, 도출된 증가계수를 통하여 연결형 말뚝기초의 저항력을 산정한 결과 측정결과와 비교적 일치하는 것으로 나타났다.