• 제목/요약/키워드: fossil fuel

검색결과 897건 처리시간 0.024초

산업배열 및 부산물을 활용한 1톤급 바이오수소 생산 시뮬레이터 동적 열설계 (Dynamic thermal Design of a 1-ton Class Bio-Hydrogen Production System Simulator Using Industrial Waste Heat and by-Products)

  • 김혜준;김석연;안준
    • 설비공학논문집
    • /
    • 제29권5호
    • /
    • pp.259-268
    • /
    • 2017
  • This paper proposes a hydrogen-based social economy derived from fuel cells capable of replacing fossil fuels and resolving global warming, It thus provides an entry for developing economically feasible social configurations to make use of bio-hydrogen production systems. Bio-hydrogen production works from the principle that microorganisms decompose water in the process of converting CO to $CO_2$, thereby producing hydrogen. This study parts from an analysis of an existing 157-ton class NA1 bio-hydrogen reactor that identifies the state of feedstock and reactor conditions. Based on this analysis, we designed a 1-ton class bio-hydrogen reactor process simulator. We carried out thermal analyses of biological heat reactions, sensible heat, and heat radiation in order to calculate the thermal load of each system element. The reactor temperature changes were determined by modeling the feed mixing tank capacity, heat exchange, and heat storage tank. An analysis was carried out to confirm the condition of the feed mixing tank, heat exchanger, heat storage tank capacity as well as the operating conditions of the system so as to maintain the target reactor temperature.

태양열 공기난방기에서 핀의 형상에 따른 열전달 성능 평가 (Research on Thermal Performance by Different Fins in a Solar Air Heater)

  • 최휘웅;홍부표;윤정인;손창효;최광환
    • 한국태양에너지학회 논문집
    • /
    • 제33권6호
    • /
    • pp.85-91
    • /
    • 2013
  • It is essential to reduce the amount of fossil fuel because facing with the natural problem such as a global warming. To achieve this goal, many of interests in the use of renewable energy is growing. Especially, as one of these renewable energy systems, a solar air heater invention has been conducted for enhancing the efficiency of solar air heater. According to this trend, scale-down sized experiment apparatus was constructed and performed for searching a proper fin and confirming the heat transfer performance by fin shape on constant heat condition to enhance efficiency of solar air heater. In this experiment, heat gain, convection heat transfer coefficient, number of transfer units, Nusselt number, Reynold's number, friction factor, performance factor were investigated in order to evaluate the thermal characteristics based on the real data obtained. By comparison with the each fin performance, a zigzag shape keeping a right angle to the plate had the highest value among them.

평지붕 PV거치 시스템의 형태에 따른 풍압영향에 관한 기초연구 (A Basic Study on the Effect of the Wind Pressure according to Form on the Flat Roof mounted PV System)

  • 윤두영;이응직
    • 한국태양에너지학회 논문집
    • /
    • 제33권5호
    • /
    • pp.105-112
    • /
    • 2013
  • The new renewable energy became popular as a clean and sustainable alternative energy under the circumstances that the entire world is facing severe abnormal climate due to the use of fossil fuel, and among which, solar energy can be obtained anywhere and is not difficult to apply it into the existing buildings, which makes it possible to be widely distributed. However, as PV module is installed into a single plate system, it shows structural weaknesses which are vulnerable to wind load and give loss to design elements in external appearance. Accordingly, this study planned one-step parallel system to complement the problems occurring from a single plate system and used STAR-CCM+ V.8 made by CD-Adapco, a computational fluid dynamics(CFD) simulation tool to measure wind load stability and support based on the design standards for a single plate system and one-step parallel system. Building height was limited to less than 10m and wind speed was given when increasing from 35m/s to 50m/s by 5m/s on PV system installed into the flat roof. In this case, our analysis suggested that step-one parallel system was in class 7-9 according to Beaufort's wind power classification, which did not have an impact on the fixed PV system, and the single plate system is considered to cause risks in designing wind speed in central districts because it is more than wind power class 12.

플러스에너지하우스 설계 및 에너지 성능 평가 (Design and Energy Performance Evaluation of Plus Energy House)

  • 김민휘;임희원;신우철;김효중;김현기;김종규
    • 한국태양에너지학회 논문집
    • /
    • 제38권2호
    • /
    • pp.55-66
    • /
    • 2018
  • South Korea aims to shift the 20 percent of electricity supplement from the fossil fuel including the nuclear to renewable energy systems by 2030. In order to realize this agenda in the buildings, the plus energy house is necessary to increase the renewable energy supplement beyond the zero energy house. This paper suggested KePSH (KIER Energy-Plus Solar House) and energy performance of house and renewable energy systems was investigated. The KePSH has the target of generating 40% surplus energy than the conventional house energy consumption. The plus energy house is the house that generates surplus energy from the renewable energy sources than that consumes. In order to minimize the cooling and heating load of the house, the shape design and passive parameters design were conducted. Based on the experimental data of the plug load in the typical house, the total energy consumption of the house was estimated. This paper also suggested renewable energy sources integrated HVAC system using air-source heat pump system. Two cases of renewable energy system integration methods were suggested, and energy performance of the cases was investigated using TRNSYS 17 program. The results showed that the BIPV (building integrated photovoltaic) system (i.e., CASE 1) and BIPV and BIST system (i.e., CASE 2) shows 42% and 29% of plus energy rate, respectivey. Also, CASE 1 can generate 59% more surplus energy compared with the CASE 2 under the same installation area.

보일러 내부 고온가스에 노출된 전열 튜브에서의 열유속 평가 방법 (Estimation method of heat flux at tube bank exposed to high temperature flue gas in large scale coal fired boilers)

  • 정재진;송정일
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.259-264
    • /
    • 2009
  • Most of the fossil power plants firing lower grade coals are challenged with maintaining good combustion conditions while maximizing generation and minimizing emissions. In many cases significant derate, availability losses and increase in unburned carbon levels can be attributed to poor combustion conditions as a result of poorly controlled local fuel and air distribution within the boiler furnace. The poor combustion conditions are directly related to the gas flow deviation in upper furnace and convection tube-bank but a less reported issue related to in large-scale oppose wall fired boilers. In order to develop a on-line combustion monitoring system and suggest an alternative heat flux estimation method at tube bank, which is very useful information for boiler design tool and blower optimizing system, field test was conducted at operating power boiler. During the field test the exhaust gases' temperature and tube metal temperature were monitored by using a spatially distributed sensors grid which located in the boiler's high temperature vestibule region. At these locations. the flue gas flow is still significantly stratified, and air in-leakage is minimal which enables tracing of poor combustion zones to specific burners and over-fire air ports. Test results showed that the flue gas monitoring method is more proper than metal temperature distribution monitoring for real time combustion monitoring because tube metal temp. distribution monitoring method is related to so many variables such as flue gas, internal flow unbalance, spray etc., Heat flux estimation at the tube bank with flue gas temp. and metal temp. data can be alternative method when tube drilling type sensor can't able to use.

  • PDF

태양광 인버터의 한국형 전력변환 효율에 관한 연구 (A Study of Korean Efficiency of PV PCS)

  • 김정환;유병규;소정훈;이기옥;유권종
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.356-360
    • /
    • 2009
  • Recent global environmental pollution and contamination and depletion of limited fossil energy prices surge as an energy source to replace it depending on wind, fuel cells and solar power and other renewable and pollution free renewable energy is of interest in increase. The photovoltaic systems are pollution-free, unlimited energy source, and easy to install because it is rated as the most valuable renewable energy sector and the prevalence is spreading throughout the world. Photovoltaic systems at one end of the stable development of the role that solar power inverter applications can be the most important. No matter how much power the solar arrays, even if the inverter output in the normally if he's no use. These photovoltaic inverters to evaluate the performance of the inverter efficiency measures that can be called directly. This way of measuring the efficiency of solar inverters in Europe efficiency and CEC efficiency is currently being used. In this paper, until now about how to measure the efficiency of solar power inverter technology and the new Korean Meteorological Solar Insolation data analysis to derive weights based on this inverter efficiency for Korea is to offer.

  • PDF

강수 함유 자성물질에 대한 환경자기학적 분석 (Magnetic Particles in Rainfalls: An Environmental Magnetic Evaluation)

  • 암알잘갈;유용재
    • 한국광물학회지
    • /
    • 제23권2호
    • /
    • pp.99-106
    • /
    • 2010
  • 금번 연구에서는 2009년 1월 1일부터 12월 31일 사이에 대전광역시 유성구 지역에서 확보한 강수 시료를 대상으로 강수에 의한 오염 희석 규명을 시도하였다. 강수여과물에 대해 등온잔류자화(Isothermal remanent magnetization) 측정과 현미경 분석 및 정성적인 화학 성분 분석을 실시하였다. 비강수일에 포집한 먼지 시료와 황사발생일에 채취한 먼지 시료도 비교를 위해 실험에 사용하였다. 자화특성 실험과 현미경 관찰 결과를 바탕으로 판단하면, 강수에서 여과된 고체 시료에 존재하는 자성 물질은 자철석이다. 관찰된 자성 물질의 특이한 형태(구형/타원체형)와 탄소 함유를 고려하면, 인위적인 연소에 의해 형성된 자철석이라 해석된다. 강수에서 여과된 고체 시료의 등온잔류자화는 일반 먼지보다도 낮고 황사에 비해서는 현저히 낮은데, 이는 강수에 의해 발생하는 상당한 양의 자성물질 희석 효과라 판단된다.

Changes of Landscape Structure for the Recent 20 Years in the Wangsuk Stream Basin of the Central Korea

  • Lee, Chang-Seok;Cho, Yong-Chan;Shin, Hyun-Chul;Lee, Seon-Mi
    • Journal of Ecology and Environment
    • /
    • 제29권4호
    • /
    • pp.405-410
    • /
    • 2006
  • Landscape changes for 20 years between 1981 and 2001 in the Wangsuk stream basin located on the central Korea were investigated on the basis of physiognomic vegetation map made from the aerial photograph interpretation and field check. Changes of landscape structure were noticeable in agricultural field and forest landscape elements. Changes in the agricultural fields due to transformation of agricultural pattern into the institutional agriculture dominated landscape change, although urbanization also contributed to such change. The former change due to change of food production structure originated from socio-economic development during this period and the latter to the overpopulation of Seoul. As energy sources for heating and cooking, fertilizer, and fodder for livestock transform from plant materials to fossil fuel, manufactured one, and grain, succession of forest escaped from direct human disturbance dominated change of landscape structure in forested land. Differently from the positive landscape change in the upper area, change in the lower area deteriorated landscape quality by increasing artificial land. It was estimated that such landscape deterioration in the Wangsuk stream basin would influence water quality of the stream. In order to realize sustainable land-use against such environmental degradation, systematic environmental management based on landscape ecological perspective such as "an eco-plan for creating riparian vegetation belt," which is under preparation by Ministry of Environment, was recommended.

Development and Utilization of Wind Energy in Korea

  • Son, Choong-Yul;Byun, Hyo-In
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.349-353
    • /
    • 2001
  • Korea has a variety of favorable conditions for utilizing wind as energy. First of all, as a geographical characteristic, it is a peninsular country with its three frontiers surrounded by sea. Such a location makes the country influenced, all the year round, both by sea winds and by seasonal winds, so that it has a good possibility of putting its rich wind resources to use as an energy source. Particularly, in view of the results of observations and analysis of actual data about wind sources, it is quite possible to build wind paver plants in many regions across the country, such as inhabited islands dotted on its southern and western coasts around the Korean peninsular, a number of uninhabited islets attached the main islands, large-scaled reclaimed lands, and major inland areas. In Korea, the attempt to develop the technology of wind paver generation started in the 1970's. It was since 1988, when the Law on the promotion of Alternative Energy Development was enacted, that research and development activities for employing the wind force as a part of energy source have got into full swing. At that moment, however, due to the low level of domestic technological development, such efforts were mainly focused on the attainment of basic technologies with regard to wind power generation. Recently, there have been many noticeable changes in the international as well as domestic environments, such as the conclusion of the International Climate Treaty and the increase in public concerns of natural environment. It is quite possible to predict that the demand for wind paver generation will increase in the near future. Therefore, recognizing that wind, as a clean energy source, can be a promising method for coping with the International Climate Treaty and for replacing the fossil fuel, oil, this essay investigates the development history of wind paver generation systems and the status of technological development in Korea and presents an appropriate model for the development of the paver generation system that can compete with other energy sources.

  • PDF

산업폐기물 소각로에서 SNCR공정에 의한 NOx 제거효율에 관한 연구 (A Study on NOx Removal Efficiency using SNCR Process in the Industrial Waste Incineration Plant)

  • 류해열;김민철;정종현;이강우;정진도
    • 한국환경보건학회지
    • /
    • 제31권4호
    • /
    • pp.332-339
    • /
    • 2005
  • The environmental regulations in the world has been reinforced and many nations has devoted themselves to the development of cost-effective technology. Selective catalyst reduction(SCR) and selective non-catalyst reduction (SNCR) processes are mainly used to treat nitrogen oxidants generated from fossil-fuel combustion. One of these typical technologies for reduction of do-NOx is SNCR process has increased continuously because of the low cost for building and maintenance. Nevertheless the researches on the application to real scale plant by the reductant like Urea are rarely studied. In this paper, an experimental investigations were performed on the SNCR process in the industrial waste incineration plant. With no reducing agent, the concentration of NOx stayed in around 180 ppm $(O_2\;12\%)$ with the exhausting temperature of $950^{\circ}C$ and changed within the range of 20 ppm to remain relatively consistent. When $10\;wt\%)$ of a solution was added, the efficiency of denitrification reached above $61.4\%$ with the NSR of 2.0 and the exhausting temperature of $950^{\circ}C.$ When the concentration of the urea solution was set to $10\;wt\%$ and the sprinkling to four nozzles, the reaction temperature was reduced to about $50~100^{\circ}C$ with a mixture of $10\;wt\%\;CH_3OH\;and\;5wt\%\;Na_2CO_3$ in $40\;wt\%$ of the solution. The NOx removal efficiency increased to $78.4\%,$ achieving a broader and expansive range of reaction temperatures than the addition of an unmixed pure solution.