• Title/Summary/Keyword: forearm skin

Search Result 165, Processing Time 0.027 seconds

Evaluation of Biomechanical Properties of Fractured Adjacent Soft Tissue Due to Fracture Site Spacing During Closed Reduction After Forearm Fracture: Finite Element Analysis (전완 골절 후 도수 정복 시 골절 부위 간격에 따른 골절 인접 연부 조직의 생체역학적 특성 평가: 유한요소해석)

  • Park, Jun-Sung;Lee, Sang Hyun;Song, Chanhee;Ro, Jung Hoon;Lee, Chiseung
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.5
    • /
    • pp.308-318
    • /
    • 2022
  • The purpose of this study is to evaluate the biomechanical properties of fractured adjacent soft tissue during closed reduction after forearm fracture using the finite element method. To accomplish this, a finite element (FE) model of the forearm including soft tissue was constructed, and the material properties reported in previous studies were implemented. Based on this, nine finite element models with different fracture types and fracture positions, which are the main parameters, were subjected to finite element analysis under the same load and boundary conditions. The load condition simulated the traction of increasing the fracture site spacing from 0.4 mm to 1.6 mm at intervals of 0.4 mm at the distal end of the radioulnar bone. Through the finite element analysis, the fracture type, fracture location, and displacement were compared and analyzed for the fracture site spacing of the fractured portion and the maximum equivalent stress of the soft tissues adjacent to the fracture(interosseous membrane, muscle, fat, and skin). The results of this study are as follows. The effect of the major parameters on the fracture site spacing of the fractured part is negligible. Also, from the displacement of 1.2 mm, the maximum equivalent stress of the interosseous membrane and muscle adjacent to the fractured bone exceeds the ultimate tensile strength of the material. In addition, it was confirmed that the maximum equivalent stresses of soft tissues(fat, skin) were different in size but similar in trend. As a result, this study was able to numerically confirm the damage to the adjacent soft tissue due to the fracture site spacing during closed reduction of forearm fracture.

In vitro cell recovery methoc as an altermative to human damaged skin recovery test

  • An, Su-Sun;Nam, Ki-Taek;Park, Jong-Ho;Koh, Jae-Sook
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.23 no.3
    • /
    • pp.97-100
    • /
    • 1997
  • These days, the raw materials that have the cell recovering effect are used commonly in cosmetics. In this study, six materials were rested for the characteristics of recovering effect both on vivo and in vitro. Tested raw materials were Soypol, 3-APPA, Apple extract, Polygonatum japonicum extract, Scutellarkd baicalensis extract, Aloe extract. Among these materials, Soypol and 3-APPA were synthesized and others were made by extraction at the Pacific R&D Center. Human forearm skin and cultured skin cell were damaged by sodium lauryl sulfare and then raw materials were applied for open treatment on SLS damaged human skin or cells. The recovering effects of raw materials in vivo were evaluated by measuring transepidermal water loss, skin hydration and erythema and in vitro effects of proliferationg cells were assessed by neutral red uptake assay. In the in vivo study, only the evaluation by TEWL showed correlation with the visual score. Our of six materials, 3-APPA had the most positive effect in both in vivo and in vitro studies and the correlation was r=0.8286 (p=0.042).

  • PDF

Scanning Electron Microscopic Observation of Human Skin Replica

  • Rhyu, Yeon-Seung;Chung, Ye-Ji;Uhm, Chang-Sub
    • Applied Microscopy
    • /
    • v.40 no.4
    • /
    • pp.267-270
    • /
    • 2010
  • The skin is the largest organ of the integument system whose surface is closely related with many physiological and pathological conditions. Various methods are used to understand the structural and functional status of human skin. We would like to present usefulness of scanning electron microscopic (SEM) observation of skin replica and its significance of training module for a novice. The silicon replicas from several regions of the body (hand, finger, forearm, lip, and face) were casted by applying Exafine$^{(R)}$ mixture. The positive replicas were prepared by applying EPON 812 mixture on negative silicon replicas. Some of the negative silicon replicas were cut with a razor blade and surface profiles were observed. The negative and positive replicas were coated with platinum and were observed under the scanning electron microscope. We could investigate the detailed structures of the human skin surface without any physical damage to the subject. The positive replicas depicted real surface structure of the human skin vividly. The cross sectional view of the negative silicon replicas provided surface profile clearly. The scanning electron microscopic observation of the human skin replicas would be useful to study skin surface structures and to evaluate medical and esthetical applications.

Design of myoelectrical sensor for myoelectric hand prosthesis (전동의수용 근전위 센서 설계)

  • Choi, Gi-Won;Choe, Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.247-249
    • /
    • 2007
  • This paper proposes a dry-type surface myoelectric sensor for the myoelectric hand prosthesis. The designed surface myoelectric sensor is composed of skin interface and processing circuits. The skin interface has one reference and two input electrodes, and the reference electrode is located in the center of two input electrodes. Considering the conduction velocity and the median frequency of the myoelectric signal, the inter-electrode distance (IED) between two input electrodes as 18mm, 20mm, and 22mm is selected. The signal processing circuit consists of a differential amplifier with a band pass filter, a band rejection filter for rejecting 60㎐ power-line noise, amplifier, and a level circuit. Using SUS440, six prototype skin interface with different reference electrode shape and IED is fabricated, and their output characteristics are evaluated by output signal obtained from the forearm of a healthy subject. The experimental results show that the skin interface with parallel bar shape and the 18mm IED has a good output characteristics. The fabricated dry-type surface myoelectric sensor is evaluated for the upper-limb amputee.

  • PDF

Evaluation for the Improving Effect of Skin Surface by Image Analyzer (Image Analyser를 이용한 화장품 사용전후의 피부표면 개선에 대한 평가)

  • Baek, Byeong-Gi;Han, Chang-Gyu;Lee, Yeong-Un
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.16 no.1
    • /
    • pp.18-29
    • /
    • 1990
  • In this report, the variation of skin surface between before treatment and after treatment was investigated by skin image analyzer. The 30 volunteers were applied cream and lotion on the forearm Inside for 4 weeks, and the measurement parameter of skirl surface was adopted peak, length, height, and width. The results were as follows ; 1. variation trends of parameters was showed that number of peaks were increased, but length, height and width were decreased. 2. The order of improvement for skin surface are as follow ; height > length > peak > width. 3. And also disclosed that the number of peak has a correlation with width, and length has a correlation with height.

  • PDF

Analysis of Skin Micro-relief on Healthy Korean Youth According to Sex (건강한 한국인 청년에서 성별에 따른 피부표면 미세지형 분석)

  • Kim, Hyun-Wook;Oh, Seung-Hak;Kim, Nam-Sook;Na, Ji-Eun;Lee, Sang-Hoon;Park, In-Sung;Kwon, Soon-Wook;Rhyu, Im-Joo
    • Applied Microscopy
    • /
    • v.42 no.1
    • /
    • pp.35-42
    • /
    • 2012
  • The skin is the largest organ of the integument system whose surface is closely related to many physiological and pathological conditions. The skin surface is closely related to functional status of the epidermis and dermis. The outermost surface of the skin shows characteristic pattern defined by small furrows are called micro-relief. The micro-relief change is according to physiological and pathological conditions of the skin. But, there is no data on health Korean skin micro-relief yet. This study presents some aspect of health Korean skin micro-relief from the twenties. The silicon replicas obtained from forearm, dorsum hand and finger were analyzed by profiles were accessed by stereoscopy. We measured density of furrow, width of furrow, and depth of furrow in micro-relief with sectioned silicon replica sample using stereoscope. Stereoscopic analysis showed that male group has a larger density of furrow and depth furrow in finger significantly. The densities of furrow were shown different not only between forearm and finger but also between finger and hand in male with female group. In conclusion, there were differences results between sex different and regional difference in skin replica profile. These quantitative data can be used for basis of further skin research for Korean.

Foot Reconstruction using Radial Forearm Free Flap - Review of 21 Cases - (요측 전완부 피판을 이용한 족부 재건 - 21례에 대한 임상적 고찰 -)

  • Lee, Kwang-Suk;Lee, Seoung-Joon;Song, Hyung-Suk;Kim, Sang-Bum
    • Archives of Reconstructive Microsurgery
    • /
    • v.12 no.2
    • /
    • pp.119-124
    • /
    • 2003
  • Introduction : The purpose is a retrospective evaluation of the clinical results of the radial forearm flap transfer for foot reconstruction. Materials and methods : We evaluated 21 cases with medical records including etiology, wound dimension, presence of infection, associated fracture, ischemic time of free flap, complication of donor and recipient site. The final results were evaluated with our clinical score (walking, shoe-in, cosmetic). Results : Defects were located on the heel (12 cases), dorsum of foot (4 cases) and sole (5 cases). Mean wound dimension was $7.56{\times}6.0cm$, and mean ischemic time of free flap was 94.5minute. There were superficial skin necrosis (1 case), recurrent ulceration (2 cases) in recipient site, and no complication in donor site but complaint about cosmetic problem (3 cases). The clinical score showed excellent in 14 cases, good in 4 cases, fair in 1 case and poor in 2 cases. Conclusion : We consider the radial forearm flap could provid the stable and durable restoration of normal foot contour without debulking in the foot reconstruction and achieved normal ambulation and cosmetic satisfaction.

  • PDF

Effects of Oral Intake of Kimchi-Derived Lactobacillus plantarum K8 Lysates on Skin Moisturizing

  • Kim, Hangeun;Kim, Hye Rim;Jeong, Bong jun;Lee, Seung Su;Kim, Tae-Rahk;Jeong, Ji Hye;Lee, Miyeong;Lee, Sinai;Lee, Jong Suk;Chung, Dae Kyun
    • Journal of Microbiology and Biotechnology
    • /
    • v.25 no.1
    • /
    • pp.74-80
    • /
    • 2015
  • Skin is the soft outer covering of vertebrates that provides protection from pathogenic infection, physical damage, or UV irradiation, and controls body temperature and water content. In this study, we examined the effects of oral intake of kimchi-derived Lactobacillus plantarum K8 lysates on skin moisturizing. In an in vitro study, we observed that the hyaluronic acid content increased in HaCaT cells treated with L. plantarum K8 lysates. Oral administration of L. plantarum K8 lysates effectively attenuated the horny layer formation and decreased epidermal thickening in DNCB-treated SKH-1 hairless mice skin. The damage to barrier function was reduced after 8 weeks of oral administration of L. plantarum K8 lysates as compared with that in the atopic dermatitis mice. For the test with volunteers, we manufactured experimental candy containing 2.1% L. plantarum K8 lysates, while control candy did not contain bacterial lysate. A significant increase in hydration in the experimental candy-administered group as compared with the control candy-administered group was observed on the face after 4 and 8 weeks, and on the forearm after 4 weeks. Decreases in horny layer thickness and TEWL value were observed on the face and forearm of the experimental group. Together, the in vitro cell line and in vivo mouse studies revealed that L. plantarum K8 lysates have a moisturizing effect. A clinical research study with healthy volunteers also showed an improvement in barrier repair and function when volunteers took L. plantarum K8 lysates-containing candy. Thus, our results suggest that L. plantarum K8 lysates may help to improve skin barrier function.

Study on the Classification and Improvement of Dehydrated Skin under Warm Air Heating Condition (온풍 조건에서 수분 탈락 정도에 따른 피부 분류 및 개선 방안에 대한 연구)

  • Kwon, Oh Sun;Kang, Hyun Jong;Han, Seu ng Min;Yoon, Ji Seon;Cho, Woong Hee;Oh, Joo You ng;Lim, Jun Man;Song, Young Sook;Park, Sun Gyoo
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.46 no.2
    • /
    • pp.179-184
    • /
    • 2020
  • Elasticity and softness of the skin depend on the level of moisture present in the stratum corneum, which is known to be affected by various environmental changes, such as cold and hot winds and dry environments. However, not many studies have been conducted on changes in skin moisture and the degree of recovery due to individual skin differences. In the present study, we aimed to investigate the effect of warm air heating on skin hydration levels and develop moisturizing formulas to improve lowered skin hydration levels. In order to deliver warm air heating condition, heating dryer (40 ℃, 6 m/s, 30 cm apart from forearm) was applied into inner forearm of healthy subjects (male: 10, female: 39, age: 25 - 63) Among 49 subjects, 26 subjects showed significantly lowered skin hydration levels until 30 min after warm air heating exposure (lowered group). In addition, moisturizing cream with high water holding capacity was applied to forearm of 10 subjects in lowered group for 3 weeks and skin hydration levels after warm air heating were significantly improved at the levels of before application of warm air heating. From this study, we found out that there is a skin type that skin hydration levels are significantly decreased under warm air heating condition (dehydrated skin) and this dehydrated skin can be improved by moisturizing formulas with high water holding capacity.

Evaluation of Thermal Physiological Responses and Comfort in Dox Fabric (한지닥 섬유제품의 인체 생리 반응 및 쾌적성 평가)

  • Im, Soon
    • Journal of the Korean Society of Costume
    • /
    • v.63 no.5
    • /
    • pp.102-114
    • /
    • 2013
  • This study performed the evaluation of skin temperature, heart rate, humidity and temperature inside clothing, and subjective sensation to estimate the physiological responses of the human body and its feeling of comfort for developing value-added dox fabric. Experiments were performed on five healthy adult women whose average age was 21, at climate chamber in which temperature, relative humidity and air current were set up below $28{\pm}5^{\circ}C$, $50{\pm}10%$, 0.2m/s, respectively. Two kinds of clothes were used for the experiments: 100% cotton and dox clothes. The clothes were identical in size and form, and the attire consisted of long-sleeved shirts, long trousers, and socks. The experiment was performed for 30 minutes using ergometer. The results are as follows. 1) It showed low skin temperature of forearm, breast, back, forehead and lower leg in exercise, but high skin temperature of them in recovery. However skin temperature of thigh and foot increased from rest to recovery. 2) It showed significant difference (p<0.001, p<0.01) in average skin temperature between cotton and dox clothes. Cotton clothes had a higher average skin temperature compared to dox. Not only was there a significant difference in temperature inside clothing (p<0.001), this was also the case with humidity inside the clothing (p<0.001).