• Title/Summary/Keyword: forearm

Search Result 630, Processing Time 0.026 seconds

Electromyographic Analysis of Isometric and Isotonic Contraction in the Forearm. (전완(前腕)에서 등장성수축(等長性收縮)과 등력성(等力性) 수축(收縮)의 근전도적(筋電圖的) 분석(分析))

  • Yeum, Cheol-Ho;Yoon, Pyung-Jin
    • The Korean Journal of Physiology
    • /
    • v.17 no.1
    • /
    • pp.37-43
    • /
    • 1983
  • Electromyographic analysis was made in the forearm to clarify the prime mover of the wrist joint in flexion and extension. Loads of 5 and 10 pounds were given to the hand during isometric and isotonic contraction. The results of this study were summarized as follows: 1) M. flexor carpi ulnaris and m. extensor carpi radialis acted as the prime mover during flexion and extension, respectively, of the wrist joint. 2) The flexor and the extensor of the forearm showed synergistic activities under isotonic contraction, but under isometric contraction the flexor only acted. 3) Muscular activity during the isotonic contraction slightly increased compared with the isometric contraction. 4) EMGs and integrated EMGs were somewhat enhanced as the load increased, but there was no significant difference between 5 and 10 pounds load.

  • PDF

The Functional Results of Forearm and Upper Arm Replantation: Report on Two Cases

  • Yu, Chang Eun;Chae, Young Ju;Lee, Jun-Mo
    • Archives of Reconstructive Microsurgery
    • /
    • v.23 no.2
    • /
    • pp.82-85
    • /
    • 2014
  • Upper extremity replantation is relatively less commonly performed than finger or hand replantation. We have experienced one case of forearm replantation and one case of upper arm replantation. After the replantation, limb volume at the biceps brachii muscle level below the replantation level appeared to be appropriate, however, the motor function of the muscles and the sensitivity were disappointing. For replantation of forearm and upper arm, restoration of the motor function and sensitivity of the extremity below the amputation level as well as the morphologic reconstruction have to be considered.

A Schwannoma Originating from Median Nerve at Proximal Forearm Caused Ulnar Nerve Symptom by Compression

  • Yoo, Jeong Hyun;Kim, Joon Yub;Kim, Hyoung Soo;Kim, Joo Hak;Sung, Ki Hyuk;Song, Sang Hun;Kwak, Ho Il
    • Archives of Reconstructive Microsurgery
    • /
    • v.23 no.2
    • /
    • pp.86-88
    • /
    • 2014
  • A schwannoma is a benign soft tissue tumor arising from the nerve sheath of a Schwann cell. Clinically, a schwannoma is an asymptomatic mass rarely causing neurologic deficits. However, it can cause discomfort as well as motor and sensory disturbances by compressing the nerve of its origin. The authors encountered a huge schwannoma arising from the median nerve at the proximal forearm, which caused symptoms mainly in the ulnar nerve. The tingling sensation along the ulnar nerve disappeared completely after enucleation of the schwannoma originating from the median nerve.

One more many more criteria for a design of ergonomic keyboard-slope angle (Keyboard Frame의 평면경사각과 측면경사각 및 Keypad 평면회전각의 변화가 Typing 수행도에 미치는 영향에 관한 연구)

  • 이면우;전영호;장성록;이도준;최재호;김대철;지철규;박현규
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1990.04a
    • /
    • pp.151-162
    • /
    • 1990
  • Occupational disease among typists such as Carpal Tunnel Syndrome(CTS) and tendonitis has increased along with rapid expansion of office automation. During typing, the posture can be defined as forearm pronation, ulnar abduction, wrist extension and finger flexion. The CTS results from awkward posture between forearm-wrist-hand and the keyboard arrangement. Therefore, ergonomic principles should be emphasized in keyboard design. The objective of the study is to improve keyboard design by analyzing anatomical posture of forearm and hand during typing. An experimental study was performed to investigate relationships between a keyboard and typing performance. Results showed that typing performance is dependent to angles and slopes of a keyboard. Statistical analysis indicated that the suggested ergonomic keyboard improved typing speed significantly(17%).

  • PDF

The Validity Test of Upper·Forearm Coordinate System and the Exploratory Analysis of the Interactive Effect between Flexion/Extension and Pronation/Supination during Elbow Joint Motion (주관절 운동의 상완·전완좌표계 타당도 및 굴곡/신전과 회내/회외의 상호작용)

  • Kim, Jin-Uk
    • Korean Journal of Applied Biomechanics
    • /
    • v.20 no.2
    • /
    • pp.117-127
    • /
    • 2010
  • The axes of upper forearm coordinate system have been considered as principal axis of each segment which was component of elbow joint. The purpose of this study was to verify whether the mean direction(principal axis) of instantaneous axes of rotation for pure flexion/extension motion coincided with the flexion/extension axis of upper forearm coordinate system. The same procedure was done for pronation/supination motion. Furthermore, it was tested indirectly that there was an interaction effect between the two rotational motions. The results showed that most segment coordinate axes statistically were not consistent with the mean directions of flexion/extension and pronation/supination axes of rotation. From the results, it would be concluded that the ISB coordinate systems was proved to be a little valid for human movement analysis. There also was an effect of pronation/supination angles on flexion/extension motion.

Revisiting radial forearm free flap for successful venous drainage

  • Cha, Yong Hoon;Nam, Woong;Cha, In-Ho;Kim, Hyung Jun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.39
    • /
    • pp.14.1-14.4
    • /
    • 2017
  • Tissue defect reconstruction using radial forearm free flap (RFFF) is a common surgical technique whose success or failure is mainly dependent on venous drainage. RFFF has two major venous outflow systems, superficial and deep vein. Drainage methods include combining both systems or using one alone. This review aims to recapitulate the vascular anatomy and network of RFFF as well as shed light on deep vein as a reliable venous drainage system. We also discuss basic evidence for and advantages of single microanastomosis with coalesced vein to overcome technical difficulties associated with the deep vein system.

Immediate Fasciotomy for Acute Thermal Contact Burn Combined with Compression Injury of the Right Forearm and Hand: A Case Report (우측 전완부와 수부에 화상과 압궤손상을 입은 환자에서 즉시 근막절제술: 증례보고)

  • Jung, Sung Won;Lee, Seungje;Yoo, Kyung-Tak
    • Journal of the Korean Burn Society
    • /
    • v.23 no.1
    • /
    • pp.13-19
    • /
    • 2020
  • Treatment of compartment syndrome is early decompressive fasciotomy to prevent dreadful sequelae of ischemic necrosis of muscles and nerves. We experienced one patient of impending or early compartment syndrome of right forearm and hand caused by a hot compress machine. We did immediate fasciotomy on forearm and late flap coverage with skin graft in this patient with good results.

An accessory muscle of flexor digitorum profundus with bipennate first lumbrical: a unique variation of clinical significance

  • Rohini Motwani;Ariyanachi Kaliappan;Mrudula Chandrupatla
    • Anatomy and Cell Biology
    • /
    • v.56 no.1
    • /
    • pp.150-154
    • /
    • 2023
  • During the deep dissection of the front of the forearm, an anomalous accessory muscle in relation to the flexor digitorum profundus (FDP) muscle was observed in the right forearm. The accessory muscle consisted of a spindle-shaped muscle belly with a long tendon underneath the flexor pollicis longus muscle. When followed distally, the accessory muscle tendon was found lateral to the FDP tendon for the index finger and entered the palm deep to the flexor retinaculum. In the palm, we encountered the first lumbrical muscle as a bipennate muscle taking origin from the adjacent sides of the middle of the tendons of FDP and accessory muscle tendon. After giving origin to first lumbrical muscle, the accessory muscle got merged with the tendon of FDP for index finger. Understanding this kind of variation is required for radiologists and hand surgeons for diagnostic purposes and while performing corrective surgical procedures.

Functional Results of Soft Palate Defect Reconstruction using Radial Forearm Free Flap after Tonsil Cancer Surgery (편도암 절제술후 전완유리피판술을 이용한 연구개 결손부 재건의 기능적 결과)

  • Kim, Min-Sik;Sun, Dong-Il;Park, Hae-Sup;Cho, Seung-Ho;Jai, Hyeon-Soon
    • Korean Journal of Bronchoesophagology
    • /
    • v.5 no.2
    • /
    • pp.191-197
    • /
    • 1999
  • Background and Objective : Soft palate plays a great role in function of speech and swallowing. Ablation of tonsil cancer results in multi-demensional defect including soft palate in most cases and restoration of the postoperative oral cavity function is a continuing surgical challenge. Although a variety of techniques are available, radial forearm free flap has been known as an effective method for these defect, which offers a thin, pliable, and relatively hairless skin, and a long vascular pedicle. The aim of the present study is to report the speech and swallowing function test results of our 5 consecutive radial forearm free flaps used for tonsil cancers. Materials and Methods : We reviewed the medical records of 5 patients who were offered intraoral reconstruction with a radial forearm free flap after ablative surgery for tonsil cancers, from Dec. 1997 to Oct. 1998, and analyzed the surgical methods, complications, and speech and swallowing function test results. We have examined with modified barium swallow to evaluate postoperative wallowing function and articulation and resonance test for speech. Results : The tumor sizes by TNM stage(AJCC, 1997) were T1(1), T2(2), and T4(3). The paddles of flaps were tailored in multilobed designs from oval shape to pentalobed design and in variable size from 24$cm^2$ to 108$cm^2$(average size = 78.4$cm^2$), according to the defect after ablation. This procedures resulted in satisfactory flap success and functional results all but 1 case of flap contracture in 2 postoperative week, achieved early oral diet until 16-57 postoperative day(average, 28 days) and social speech. The oropharyngeal defect including soft palate reconstruction with radial forearm free flap might be an excellent method for the maximal functional results, after ablative surgery of tonsil cancer that results in multidimensional defect.

  • PDF

PRELAMINATED FREE FLAP FOR THE RECONSTRUCTION OF MAXILLARY DEFECTS (전판상화 유리조직판을 이용한 상악결손 재건)

  • Kim, Ji-Youn;Pang, Kang-Mi;Park, Jong-Chul;Kim, Sung-Min;Myoung, Hoon;Kim, Myung-Jin;Lee, Jong-Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.1
    • /
    • pp.13-20
    • /
    • 2009
  • Background In contrast to defects of the mandible and mouth floor region, in the defect of maxilla, the availability of firmly attached oral and nasal mucosal linings is needed. In addition to it, in consider of operation field, operating convenience, and esthetics, reconstruction using prelaminated flap is strongly recommended. Therefore we consider the prelaminated flap through the cases that is reconstructed using prelaminated forearm flap and prelaminated scapular flap. Patients and Methods From 2001 to 2008, in OMFS SNUDH, there were 6 cases that had reconstruction using prelaminated forearm free flap and other 3 cases that had reconstruction using prelaminated scapular flap of maxilla. The average age of patients that were reconstructed using prelaminated forearm free flap was 47.5 years, the average prelaminated period (after $1^{st}$ operation ${\sim}$ until $2^{nd}$ operation) was 51.8 days and the average follow-up period after $2^{nd}$ operation was 35.3 months. As well, the average age of patients that were reconstructed using prelaminated scapular free flap was 37 years, the average prelaminated period (after $1^{st}$ operation ${\sim}$ until $2^{nd}$ operation) was 57 days and the average follow-up period after $2^{nd}$ operation was 42.3 months. Results Except 1 case that were reconstructed using prelaminated scapular flap, we could get firmly attached oral and nasal stable skin(mucosal like) lining, more adequate thickness flap than any other flap and improved esthetic and functional results in the other 8 cases that were reconstructed using prelaminated flap. The complications of the prelaminated forearm flap cases were inconvenient swallowing, sputum, limitation of mouth opening and difficult mastication. It came from flap shrinkage of the flap in some aspect, as well as other combined operations such as mass resection or RND. The difficult point of the reconstruction of prelaminated scapular flap was the possibility of vascular damage at preparation of flap in $2^{nd}$ surgery. The damage could cause the failure of the prelaminated scapular flap. And the skin-lining of the prelaminated flap had limitations, so it is needed to study about the cultured oral epithelium-lining flap instead of the skin-lining flap. Conclusion We considered about advantages, complications and notable things of prelaminated flap through maxillary reconstruction cases using prelaminated forearm flap and prelaminated scapular flap so far. Furthermore, we should go on studying for functional reconstruction of prelaminated fasciomucosal flap using cultured oral epithelium.