• 제목/요약/키워드: force system

검색결과 7,850건 처리시간 0.03초

산업용 로봇의 힘측정 시스템을 위한 힘측정 및 통신장치 개발 (Development of a Force Measurement and Communication System for the Force Measuring System in Industrial Robots)

  • 이경준;김갑순
    • 제어로봇시스템학회논문지
    • /
    • 제22권2호
    • /
    • pp.89-96
    • /
    • 2016
  • This paper describes the design of a force measurement and communication system for the force measuring system in industrial robots. The force measurement and communication system is composed of a multi-axis force sensor and a controller for measuring the forces (x-direction force, y-direction force and z-direction force) and sending the measured forces to the robot's controller (PLC: Programmable Logic Controller). In this paper, the force measurement and communication system was designed and fabricated by using a DSP (Digital Signal Processor). An environment test and a grinding and deburring test using an industrial robot with the force measurement and communication system with three-axis force sensor were carried out to characterize the system. The tests showed that the system could safely measure the forces from the three-axis force sensor and send the measured forces to the industrial robot's controller while the grinding and deburring test was performed. Thus, it is thought that the fabricated force measurement and communication system could be used for controlling the force for an industrial robot's grinding and deburring.

Build-up 기법을 이용한 대용량 힘 측정 시스템 개발 (Large Force Measuring System Using Build-up Technique;)

  • 강대임;송후근
    • 대한기계학회논문집A
    • /
    • 제21권3호
    • /
    • pp.477-484
    • /
    • 1997
  • This paper describes the build-up force measuring system of 9.9 MN capacity which consists of nine force transducers of each having 1.1 MN capacity. We have specially designed a force transducer for a build-up force measuring system to reduce the uncertainty of a build-up system and to accomodate the new test procedure for a build-up system. It reveals that the relative uncertainty of the force measuring system is less than 1.5*10$^{-4}$ in the ran9e of 1-4.5 MN irrespective of loading direction. The force measuring system may be used to calibrate a 10 MN force standard machine to be used as a large force standard in Korea.

힘센서를 이용한 후크형 손가락 힘 측정 장치 개발 (Development of a Hook-type Finger Force Measuring System with Force Sensors)

  • 김갑순
    • 제어로봇시스템학회논문지
    • /
    • 제20권6호
    • /
    • pp.663-668
    • /
    • 2014
  • This paper presents a hook-type finger force measuring system with force sensors. The system is composed of a body, two three-axis force sensors, a hook, and so on. The two three-axis force sensors system was specially designed using FEM(Finite Element Method) and fabricated using strain-gages. The sensors measure the finger forces of both normal people and handicapped people in the system, and the forces are combined. The developed hook-type finger force measuring system can measure the pulling finger force of both normal and handicapped people. The pulling force tests of men and women were performed using the developed the system. It is thought that the developed system can be used to measure the pulling force of fingers.

웹기반 힘관리시스템의 구현 (Implementation of Web-based Force Management System)

  • 박철호;강철구;남현도
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.835-839
    • /
    • 2004
  • For factory automation using force/torque control, we need a networked-force management system as well as good force sensing and force generation. In this paper, we present a web-based force management system including 6-axis force/torque sensing system. Performance of the force-torque sensor is affected significantly by analog noise that is included in a sensor signal, and the noise should be reduced appropriately to obtain an adequate performance of the sensor. Moreover, the sensor itself should be convenient to install to a real application system. It should be compact in size and also easy to wire in real situation. In this viewpoint, we developed usb-based compact sensor system which is well communicated using web between two computers that exist far away. Software is programmed using LabVIEW and CCS-C. PIC microcontrollers are used for implementing a compact hardware. The proposed system is verified through experimental works.

  • PDF

3축 힘센서를 이용한 두 손가락 힘측정장치 개발 (Development of Force Measuring System using Three-axis Force Sensor for Measuring Two-finger Force)

  • 김현민;윤정원;신희석;김갑순
    • 제어로봇시스템학회논문지
    • /
    • 제16권9호
    • /
    • pp.876-882
    • /
    • 2010
  • Stroke patients can't use their hands because of the paralysis their fingers. Their fingers are recovered by rehabilitating training, and the rehabilitating extent can be judged by measuring the pressing force to be contacted with two fingers (thumb and first finger, thumb and middle finger, thumb and ring finger, thumb and little finger). But, at present, the grasping finger force of two-finger can't be accurately measured, because there is not a proper finger-force measuring system. Therefore, doctors can't correctly judge the rehabilitating extent. So, the finger-force measuring system which can measure the grasping force of two-finger must be developed. In this paper, the finger-force measuring system with a three-axis force sensor which can measure the pressing force was developed. The three-axis force sensor was designed and fabricated, and the force measuring device was designed and manufactured using DSP (Digital Signal Processing). Also, the grasping force test of men was performed using the developed finger-force measuring system, it was confirmed that the grasping forces of men were different according to grasping methods.

BUILD-UP 힘측정 시스템의 출력거동 (Output Behavior of Build-Up Force Measuring System)

  • 강대임;송후근;홍창선
    • 대한기계학회논문집
    • /
    • 제19권9호
    • /
    • pp.2194-2205
    • /
    • 1995
  • In order to reduce the systematic error of a build-up system, we have proposed a new test procedure in which all force transducers in a build-up system are rotated by 90.deg. with a base platen fixed on a force standard machine. The setting positions of force transducers on the output of a build-up system were investigated using an orthogonal array. The effects of the parallelism of a build-up system and of the bending moment sensitivity of a force transducer were considered. The experimental results show that the setting position of the base platen hardly affects the output of the build-up system, but the setting positions of force transducers affects it strongly. It reveals that the new test procedure reduces effectively the systematic error of a build-up system.

Continuous straight archwire에 의하여 발생하는 force system의 분석 (Analysis of force system developed by continuous straight archwire)

  • 최광철;손병화
    • 대한치과교정학회지
    • /
    • 제26권3호
    • /
    • pp.281-290
    • /
    • 1996
  • Edgewise bracket에 continuous straight archwire를 장착 했을 때 각 bracket에 발생 하는 force system은 statically indeterminate system이기 때문에 임상적으로 측정이 어렵다. 이에 본 연구는 linear beam theory를 도입하여 full arch에 straight wire가 장착된 경우 geometry(a/b), 재질, 단면의 모양, interbracket distance에 관계없이 발생 가능한 모든 상태를 설명할 수 있는 식을 유도하고 일례의 분석을 통하여 다음과 같은 결과를 얻었다. 1. Bilateral fixed beam의 양끝에서 발생하는 force system을 알 수 있는 계산식을 얻었다. 2. 이를 이용하여 continuous straight archwire가 장착된 경우 각 치아에 발생하는 force system을 알 수 있다. 3. Continuous straight archwire장착시 영구변형의 발생여부와 발생위치를 예측 할 수 있다.

  • PDF

수완계 진동 평가에 영향을 미치는 작용력의 측정 (Measurement of Grip and Feed Force in the Evaluation of Hand-arm Vibration)

  • 최석현;장한기
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.1038-1042
    • /
    • 2003
  • In order to evaluate dynamic impedance of a hand-arm system it is necessary to measure the hand-transmitted vibration and the reaction force at the same time while gripping the vibrating handle. In the study a device was developed to measure both the vibration and the force. The device consists of a measurement handle with four strain gauge and two accelerometers and a PC based control system with a program for the signal processing and evaluation of the hand-transmitted vibration and reaction force. The handle was installed on the vibration shaker so that it can move by the generated signal from the control system. As an application of the system dynamic reaction force and the frequency weighted acceleration at the handle attached to the shaker were measured at various grip force and feed force. This system will be very useful in the area of impedance measurement and the evaluation of performance of anti-vibration gloves.

  • PDF

햅틱기술을 이용한 뇌졸중환자의 원통물체잡기 힘측정장치 개발 (Development of Cylindrical-object Grasping Force Measuring System with Haptic Technology for Stroke's Fingers)

  • 김현민;김갑순
    • 한국정밀공학회지
    • /
    • 제30권3호
    • /
    • pp.300-307
    • /
    • 2013
  • This paper describes the development of a cylindrical-object grasping force measuring system applied haptic technology to measure the grasping force of strokes patients' fingers and other patients' paralyzed fingers. Because the cylindrical-object and the force measuring device of the developed cylindrical-object grasping force measuring system are connected with the electrical wires, patients and their families have difficulty not only measuring the patients' grasping force using the system but also knowing their rehabilitation extent when using it. In this paper, the cylindrical-object grasping force measuring system applied haptic technology was developed, and the cylindrical-object grasping force measuring device sends data to the rehabilitation evaluating system applied haptic technology by wireless communication. The grasping force measurement characteristic test using the system was carried out, and it was confirmed that the rehabilitation extent of the patients' paralyzed fingers and normal people fingers can be evaluated.

2축 힘/모멘트센서를 이용한 원통형 손가락 힘측정장치 개발 및 특성평가 (Development of Cylindrical-type Finger Force Measuring System Using Two-axis Force/Moment Sensor and its Characteristic Evaluation)

  • 김갑순
    • 제어로봇시스템학회논문지
    • /
    • 제17권5호
    • /
    • pp.484-489
    • /
    • 2011
  • Some patients can't use their hands because of inherent and acquired paralysis of their fingers. Their fingers can recover with rehabilitative training, and the extent of rehabilitation can be judged by grasping a cylindrical-object with their fingers. At present, the cylindrical-object used in hospitals is only a cylinder which cannot measure grasping force of the fingers. Therefore, doctors must judge the extent of rehabilitation by watching patients' fingers as they grasp the cylinder. A cylindrical-type finger force measuring system which can measure the grasping force of patients' fingers should be developed. This paper looks at the development of a cylindrical-type finger force measuring system with two-axis force/moment sensor which can measure grasping force. The two-axis force/moment sensor was designed and fabricated, and the high-speed force measuring device was designed and manufactured by using DSP (digital signal processing). Also, cylindrical-type finger force measuring system was developed using the developed two-axis force/moment sensor and the high-speed force measuring device, and the grasping force tests of men were performed using the developed system. The tests confirm that the average finger forces of right and left hands for men were about 186N and 172N respectively.