• Title/Summary/Keyword: force approximation

Search Result 136, Processing Time 0.023 seconds

A Three-Dimensional Galerkin-FEM Model with Density Variation (밀도 변화를 포함하는 3차원 연직함수 전개모형)

  • 이호진;정경태;소재귀;강관수;정종율
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.8 no.2
    • /
    • pp.123-136
    • /
    • 1996
  • A three-dimensional Galerkin-FEM model which can handle the temporal and spatial variation of density is presented. The hydrostatic approximation is used and density effects are included by means of conservation equation of heat and the equation of state. The finite difference grids are used in the horizontal plane and a set of linear-shape functions is used for the vertical expansion. The similarity transform is introduced to solve resultant matrix equations. The proposed model was first applied to the density-driven circulation in an idealized basin in the presence of the heat exchange between the air and the sea. The advection terms in the momentum equation were ignored, while the convection terms were retained in the heat equation. Coefficients of the vertical eddy viscosity and diffusivity were fixed to be constant. Calculation in a non-rotating idealized basin shows that the difference in heat capacity with depth gives rise to the horizontal gradient of temperature. Consequently, there is a steady new in the upper layer in the direction of increasing depth with compensatory counter flow .in the lower layer. With Coriolis force, geostrophic flow was predominant due to the balance between the pressure gradient and the Coriolis force. As a test in region of irregular topography, the model is applied to the Yellow Sea. Although the resultant flow was very complex, the character of the flow Showed to be geostrophic on the whole.

  • PDF

Centrifugal Test on Behavior of the Dolphin Structure under Ship Collision (선박충돌 시 돌핀 구조물의 거동에 대한 원심모형실험)

  • Oh, SeungTak;Bae, WooSeok;Cho, SungMin;Heo, Yol
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.1
    • /
    • pp.61-70
    • /
    • 2011
  • The impact protection system consists of an arrangement of circular sheet pile cofferdams-denoted dolphin structuredeeply embedded in the seabed, filled with crushed rock and closed at the top with a robust concrete cap. Centrifuge model tests were performed to investigation the behaviors of dolphins in this study. Total 7 quasi-model tests and 11 dynamic model tests were performed. The main experimental results can be summarized as follows. Firstly, The experimental force-displacement results for quasi-static tests show a limited influence on the initial stiffness of the structure from the change in fill density and the related change in the stiffness of the fill. And by comparing the dissipation at the same dolphin displacement it was found that the denser fill increase the dissipation by 16% for the 20m dolphin and by 23% for the 30m dolphin. The larger sensitivity for the large dolphin is explained by a larger contribution to the dissipation from strain in the fill. In low level impacts the dynamic force-response is up to 26~58% larger than the quasi-static and the dissipation response is showed larger in small displacement. Hence, it is concluded conservative to use the quasi-static response characteristics in the approximation of the response, and it is further concluded that the dolphin resistance to low level impacts is demonstrated to be equivalent and even superior to the high level impacts.

MANAGEMENT OF DIASTEMA AFTER REMOVAL OF MESIODENS (정중 과잉치 발거 이후 정중 이개의 폐쇄)

  • Cho, Eun-Ju;Choi, Yeong-Chul;Lee, Keung-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.3
    • /
    • pp.348-353
    • /
    • 2003
  • Early detection and prudent management of mesiodens or supernumerary tooth should be considered essential in reducing disturbance in the eruption and position of the adjacent permanent incisor. While it is true that the presence of diastema may be regarded as normal at the early mixed dentition stage, the early detection and removal of the mesiodens is a prerequisite to facilitate spontaneous alignment or subsequent approximation of the permanent central incisors. In many cases, diastema due to mesiodens can be physiologically corrected spontaneously after the extraction of mesiodens. The best choice of treatment of diastema may be observation. Orthodontic intervention is required only spontaneous closing of diastema does not occur within observation period. In orthodontic intervention, careful treatment plan should be established. Clinician gives considerations to angulation of central and lateral incisor, proximity of lateral incisor, developmental stage and position of canine, pattern and extent of anterior crowding. Orthodontic movement should be done slowly with light force. In addition, periodic radiographic observation are needed to monitor the root development and root resorption. Case 1, 2 and 3 showed physiologic closures after the extraction of mesiodens. In these cases, acceptable alignment of central and lateral incisors was obtained. In case 4, orthodontic correction for diastema was performed successfully after the extraction of mesiodens. After the orthodontic closure of the diastema, it was decided that a retainer was not needed, because the dentition was under a dynamic stage in exchanging teeth and also developing arches.

  • PDF

Reduction of Chattering Error of Reed Switch Sensor for Remote Measurement of Water Flow Meter (리드 스위치 센서를 이용한 원격 검침용 상수도 계량기에서 채터링 오차 감소 방안 연구)

  • Ayurzana, Odgerel;Kim, Hie-Sik
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.4 s.316
    • /
    • pp.42-47
    • /
    • 2007
  • To reduce the chattering errors of reed switch sensors in the automatic remote measurement of water meter a reed switch sensor was analyzed and improved. The operation of reed switch sensors can be described as a mechanical contact switch by approximation of permanent magnet piece to generate an electrical pulse. The reed switch sensors are used mostly in measurement application to detect the rotational or translational displacement. To apply for water flow measurement devices, the reed switch sensors should keep high reliability. They are applied for the electronic digital type of water flow meters. The reed switch sensor is just mounted simply on the conventional mechanical type flow meter. A small magnet is attached on a pointer of the water meter counter rotor. Inside the reed sensor two steel leaf springs make mechanical contact and apart repeatedly as rotation of flow meter counter. The counting electrical contact pulses can be converted as the water flow amount. The MCU sends the digital flow rate data to the server using the wireless communication network. But the digital data is occurred difference or won by chattering noise. The reed switch sensor contains chattering error by it self at the force equivalent position. The vibrations such as passing vehicle near to the switch sensor installed location causes chattering. In order to reduce chattering error, most system uses just software methods, for example using filter algorithm and also statistical calibration methods. The chattering errors were reduced by changing leaf spring structure using mechanical characteristics.

The Electronic Structure and Magnetism of bcc Rh(001) Surface (체심 입방구조 Rh(001) 표면의 전자구조와 자성)

  • Cho, L.H.;Bialek, B.;Lee, J.I.
    • Journal of the Korean Magnetics Society
    • /
    • v.18 no.6
    • /
    • pp.206-210
    • /
    • 2008
  • According to the recent reports the bulk bcc Rh is ferromagnetic with a small difference of energy compared to paramagnetic state. In this study, the electronic structure and magnetism for bcc Rh(001) surface are investigated by means of the all-electron full potential linearized augmented plane wave method within the generalized gradient approximation. It is found that the surface ferromagnetic state is preferable over the paramagnetic one. For unrelaxed system, the magnetic moment of the surface layer, $0.48{\mu}B$, is slightly increased comparing with the bulk value, $0.41{\mu}B$ while the value of the subsurface layer, $0.23{\mu}B$, is much smaller than the bulk value. The total energy and atomic force calculations show that the surface layer is relaxed downward and the subsurface layer moves upward to reduce the layer distance between the surface and subsurface layers by 7.0 %. The relaxation effect leads to weakening the surface magnetic properties. Specifically, the value of the magnetic moment of the surface atom is decreased to $0.36{\mu}B$. Since the spin polarization of the subsurface layer is only $0.14{\mu}B$, it is concluded that the bcc Rh(001) surface is rather weakly ferromagnetic.

Study of new adsorption isotherm model and kinetics of dissolved organic carbon in synthetic wastewater by granular activated carbon (입상활성탄에 의한 합성폐수의 용존유기물질의 새로운 흡착등온 모델 및 운동학적 흡착 연구)

  • Kim, Seoung-Hyun;Shin, Sunghoon;Kim, Jinhyuk;Woo, Dalsik;Lee, Hosun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.4
    • /
    • pp.2029-2035
    • /
    • 2014
  • In this study, we conducted the adsorption equilibrium and batch experiments of dissolved organic carbon (DOC) in the wastewater by granular activated carbon (GAC). The components of organic compound were Beef extract (1.8 mg/L), Peptone (2.7 mg/L), Humic acid (4.2 mg/L), Tannic acid (4.2 mg/L), Sodium lignin sulfonate (2.4 mg/L), Sodium lauryle sulfate (0.94 mg/L), Arabic gum powder (4.7 mg/L), Arabic acid (polysaccharide) (5.0 mg/L), $(NH_4)_2SO_4$ (7.1 mg/L), $K_2HPO_4$ (7.0 mg/L), $NH_4HCO_3$ (19.8 mg/L), $MgSO_4{\cdot}7H_2O$ (0.71 mg/L), The adsorption characteristics of DOC in synthetic wastewater was described using the mathematical model through a series of isotherm and batch experiments. It showed that there was linear adsorption region in the low DOC concentration (0~2.5 mg/L) and favorable adsorption region in high concentration (2.5~6 mg/L). The synthetic wastewater used was prepared using known quantities of organic and/or inorganic compounds. Adsorption modelling isotherms were predicted by the Freundlich, Langmuir, Sips and hybrid isotherm equations. Especially, hybrid isotherm of Linear and Sips equation was a good adsorption equilibrium in the region of the both the low concentration and high concentration. In applying carbon adsorption for treating water and wastewater, hybrid adsorption equation plus linear equation with Sips equation will be a good new adsorption equilibrium model. Linear driving force approximation (LDFA) kinetic equation with Hybrid (linear+Sips) adsorption isotherm model was successfully applied to predict the adsorption kinetics data in various GAC adsorbent amounts.