A new rotational force model for quasi-steady theory of plate-like windborne debris in uniform flow

  • Lin, Huatan;Huang, Peng;Gu, Ming
    • Wind and Structures
    • /
    • 제35권2호
    • /
    • pp.109-120
    • /
    • 2022
  • The force coefficients of rotating plates in the acceleration stage will vary with rotation rate from 0 to stable rotation rate w0, which are important for quasi-steady theory of plate-like windborne debris to simulate the trajectory. In this paper, a wind tunnel experiment is carried out to study the effects of geometry and the Reynolds number on the variations of mean force coefficients of rotating plates. The rotational lift coefficients are sensitive to both geometry effect and Reynolds number effect, while the rotational drag and moment coefficients are only sensitive to geometry effect. In addition, new empirical formulas for the rotational lift coefficient and moment coefficients are proposed. Its accuracy is verified by comparing the predicted results with existing test data. Based on the experimental data of rotating plates, a new rotational force model for quasi-steady theory, which can be applied to a wider scope, is proposed to calculate the trajectory of plate-like windborne debris. The results show that the new model provides a better match with the tested trajectories than previous quasi-steady theories.

몰수체의 원추형시험에 관한 연구 (Study on Coning Motion Test for Submerged Body)

  • 박종용;김낙완;이기표;윤현규;김찬기;정철민;안경수;이성균
    • 한국해양공학회지
    • /
    • 제29권6호
    • /
    • pp.436-444
    • /
    • 2015
  • A submerged body is sensitive to changes in the roll moment because of the small restoring moment and moment of inertia. Thus, a method for predicting the roll-related hydrodynamic coefficients is important. This paper describes a deduction method for the hydrodynamic coefficients based on the results of a coning motion test. A resistance test, static drift test, and coning motion test were performed to obtain the coefficients in the towing tank of Seoul National University. The sum of the hydrodynamic force, inertial force, gravity, and buoyancy was measured in the coning motion test. The hydrodynamic force was deduced by subtracting the inertial force, gravity, and buoyancy from the measured force. The hydrodynamic coefficients were deduced using the regression method.

비행시험 자료를 이용한 경항공기의 조종력 시뮬레이션 (Simulation of the control force of the light aircraft using flight test data)

  • 김정환;황명신;이정훈
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.203-206
    • /
    • 1996
  • The purpose of this paper is to find how to determine the parameters of the basic control system design such as hinge moment coefficients and to display the controllability of the ChangCong-91. Since the estimation from the flight test of real aircraft is the most reliable, we performed the flight test of ChangGong-91 to get the various parameters such as velocity, height, control force, control surface deflection, 3 axis acceleration, 3 axis angular rate, pitch angle, angle of attack temperature and so on. We recorded the flight test data in VHS tapes and stored them to personal computer using A/D(analog to digital) converter. Flight test was done in various conditions, and the acquired data was processed with parameter identification method such as least square method. These data will be utilized for the development of Autopilot System design and Control Loading System design.

  • PDF

방음벽의 유무에 따른 박스형 거더교의 풍력계수 평가 (Evaluation of Wind Force Coefficients of a Box-Type Girder Bridge with Noise Barriers)

  • 정승환;이영기
    • 대한토목학회논문집
    • /
    • 제38권5호
    • /
    • pp.627-634
    • /
    • 2018
  • 본 연구에서는 바람의 영향을 받는 박스형 콘크리트 거더교에 대한 풍력계수를 산정하기 위하여 전산유체해석(CFD)를 수행하였다. 방음벽이 없는 교량 단면에 대한 항력계수, 양력계수 및 비틀림모멘트계수를 산정하였고, 이 풍력계수 값들을 다양한 높이의 방음벽을 갖는 교량 단면에 대한 풍력계수 값들과 비교하였다. 전산유체해석에서 풍력계수들을 산정할 때 전단응력수송(SST) $k-{\omega}$ 난류 모델을 적용하였고, 마찰 항력계수가 전체 항력계수에 미치는 기여도를 조사하였다. 연구 결과, 바람이 수평으로 불 때 항력계수는 방음벽의 높이가 커질수록 증가하였고, 마찰 항력의 기여도는 교량 단면에 방음벽이 없을 때 가장 높았다. 따라서 교량설계에서 풍력을 산정할 때 방음벽의 높이의 영향을 고려할 필요가 있으며, 벽면 마찰력은 교량에 작용하는 풍력을 산정할 때 중요한 역할을 하였다.

Effect of corner modifications on 'Y' plan shaped tall building under wind load

  • Sanyal, Prasenjit;Dalui, Sujit Kumar
    • Wind and Structures
    • /
    • 제30권3호
    • /
    • pp.245-260
    • /
    • 2020
  • Wind load and responses are the major factors which govern the design norms of tall buildings. Corner modification is one of the most commonly used minor shape modification measure which significantly reduces the wind load and responses. This study presents a comparison of wind load and pressure distribution on different corner modified (chamfered and rounded) Y plan shaped buildings. The numerical study is done by ANSYS CFX. Two turbulence models, k-epsilon and Shear Stress Transport (SST), are used in the simulation of the building and the data are compared with the previous experimental results in a similar flow condition. The variation of the flow patterns, distribution of pressure over the surfaces, force and moment coefficients are evaluated and the results are represented graphically to understand the extent of nonconformities due to corner modifications. Rounded corner shape is proving out to be more efficient in comparing to chamfered corner for wind load reduction. The maximum reduction in the maximum force and moment coefficient is about 21.1% and 19.2% for 50% rounded corner cut.

상호 작용 계수를 이용한 측추력 제트와 초음속 자유류 상호 작용에 관한 연구 (Analysis of the Interaction Between Side Jet and Supersonic Free Stream Using K-factor)

  • 김민규;이광섭
    • 한국군사과학기술학회지
    • /
    • 제15권1호
    • /
    • pp.101-110
    • /
    • 2012
  • The side jet effects between jet flow and free-stream on a missile body were investigated by experimentally and numerically for modeling aerodynamic coefficients in pitch plane. K-factors for normal force and pitching moment were introduced to estimate the side jet effects. The main parameters of the jet interaction phenomena were angle of attack, jet pressure ratio, Mach number and jet bank angle. The K-factors for normal force coefficient and pitching moment coefficients in pitch plane were analysed.

FLOWING OF THE SYSTEM THE UNDERWATER VEHICLES HULL THE NOZZLE OF PUMP-JET PROPELLER WITH AMOLES OF ATTACK

  • Lee, Kwi-Joo;Nikushchenko, Dmitry V.;Park, Weon-Me
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.275-280
    • /
    • 2002
  • Results of a numerical simulation of a flowing of the underwater vehicles hull with the pump-jet nozzle are presented. It was calculate velocity distributions and coefficients of the lift force and the longitudinal moment of the hull with the pump-jet nozzle and isolated hull for some values of angle of attack. It was shown that the area of tile influence of the nozzle on the velocities distribution of the hull and character of changing of coefficients of the lift force and the longitudinal moment and their derivatives depending on angle of attack.

  • PDF

On the Instantaneous and Average Piston Friction of Swash Plate Type Hydraulic Axial Piston Machines

  • Jeong, Heon-Sul;Kim, Hyoung-Eui
    • Journal of Mechanical Science and Technology
    • /
    • 제18권10호
    • /
    • pp.1700-1711
    • /
    • 2004
  • Piston friction is one of the important but complicated sources of energy loss of a hydraulic axial piston machine. In this paper, two formulas are derived for estimating instantaneous piston friction force and average piston friction moment loss. The derived formula can be applicable for piston guides with or without bushing as well as for axial piston machines of motoring and pumping operations. Through the formula derivation, a typical curve shape of friction force found from several experimental measurements during one revolution of a machine is clearly explained in this paper that it is mainly due to the equivalent friction coefficient dependent on its angular position. Stribeck curve effect can easily be incorporated into the formula by replacing outer and inner friction coefficients at both edges of a piston with the coefficient given by Manring (1999) considering mixed/boundary lubrication effects. Novel feature of the derived formula is that it is represented only by physical dimensions of a machine, hence it allows to estimate the piston friction force and loss moment of a machine without hardworking experimental test.

아치형 단동온실의 최적설계를 위한 풍력계수분포도의 분석 (An Analysis of Wind Force Coefficient Distributions for Optimum Design of Single-Span Arched Greenhouse)

  • 이석건;이현우;권무남
    • 생물환경조절학회지
    • /
    • 제4권1호
    • /
    • pp.1-8
    • /
    • 1995
  • One of the most destructive forces around greenhouses is wind. Wind loads can be obtained by multiplying velocity pressure by dimensionless wind force coefficient. Generally, wind force coefficients can be determined by wind tunnel experiments. The wind force coefficient distribution on a single - span arched greenhouse was estimated using experimental data and compared with reported values from various countries. The results obtained are as follows : 1. The coefficients obtained from this study agree with the values proposed by G. L. Nelson except about 0.5 of difference in the middle region of roof section. This discrepancy is mainly attributed to the dissimilarity of experimental conditions (or wind tunnel test such as Reynolds number, type of terrain, surface roughness of model, location of the lapping and measuring methods. 2. Considering that the wind force coefficients are varied along the height of a wall at wind direction perpendicular to wall, structural analysis using subdivided wind force coefficient distribution is more resonable for wall. 3. It is recommendable that wind force coefficient distribution on a roof should take more subdivision than the existing four equal divisions for more accurate structural design. 4. Structural design using wind forces close to real values is more advantageous in safety and expense.

  • PDF

Effects of vertical ribs protruding from facades on the wind loads of super high-rise buildings

  • Quan, Yong;Hou, Fangchao;Gu, Ming
    • Wind and Structures
    • /
    • 제24권2호
    • /
    • pp.145-169
    • /
    • 2017
  • The auxiliary structures of a high-rise building, such as balconies, ribs, and grids, are usually much smaller than the whole building; therefore, it is difficult to simulate them on a scaled model during wind tunnel tests, and they are often ignored. However, they may have notable effects on the local or overall wind loads of the building. In the present study, a series of wind pressure wind tunnel tests and high-frequency force balance (HFFB) wind tunnel tests were conducted on rigid models of an actual super high-rise building with vertical ribs protruding from its facades. The effects of the depth and spacing of vertical ribs on the mean values, fluctuating values and the most unfavorable values of the local wind pressure coefficients were investigated by analyzing the distribution of wind pressure coefficients on the facades and the variations of the wind pressure coefficients at the cross section at 2/3 of the building height versus wind direction angle. In addition, the effects of the depth and spacing of vertical ribs on the mean values, fluctuating values and power spectra of the overall aerodynamic force coefficients were studied by analyzing the aerodynamic base moment coefficients. The results show that vertical ribs significantly decrease the most unfavorable suction coefficients in the corner recession regions and edge regions of facades and increase the mean and fluctuating along-wind overall aerodynamic forces.