• Title/Summary/Keyword: foot scanner

Search Result 31, Processing Time 0.02 seconds

A 3D Foot Scanner Using Mirrors and Single Camera (거울 및 단일 카메라를 이용한 3차원 발 스캐너)

  • Chung, Seong-Youb;Park, Sang-Kun
    • Korean Journal of Computational Design and Engineering
    • /
    • v.16 no.1
    • /
    • pp.11-20
    • /
    • 2011
  • A structured beam laser is often used to scan object and make 3D model. Multiple cameras are inevitable to see occluded areas, which is the main reason of the high price of the scanner. In this paper, a low cost 3D foot scanner is developed using one camera and two mirrors. The camera and two mirrors are located below and above the foot, respectively. Occluded area, which is the top of the foot, is reflected by the mirrors. Then the camera measures 3D point data of the bottom and top of the foot at the same time. Then, the whole foot model is reconstructed after symmetrical transformation of the data reflected by mirrors. The reliability of the scan data depends on the accuracy of the parameters between the camera and the laser. A calibration method is also proposed and verified by experiments. The results of the experiments show that the worst errors of the system are 2 mm along x, y, and z directions.

Classification of Elderly Women's Foot Type (노년 여성의 발 유형분류)

  • Kim, Nam-Soon;Do, Wol-Hee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.38 no.3
    • /
    • pp.305-320
    • /
    • 2014
  • This study identifies the foot shapes of elderly women by classifying foot type according to the 3D shape of the foot and 2D sole type analyzing individual characteristics. The subjects were 295 elderly women over 60 years of age who live in Gwangju. A foot scanner (K&I Technology $Nexcan^{(R)}$) was used to obtain three-dimensional shapes of feet and a flat bad scanner (HP Scanjet G2410) was used to obtain the two-dimensional shapes of soles. The anthropometric measuring items consisted of 59 items estimated on the right foot of each subject. Data were analyzed by various statistical methods such as factor analysis, ANOVA and cluster analysis using the SPSS 19.0 statistical program. To classify the side type of elderly women's feet, three-dimensional measurement data were analyzed for the 27 measurement items using factor analysis and 6 factors were extracted (inside height and side gradient, ankle thickness, toe height and midfoot size, lateral malleolus height, instep, and heel height and gradient). A cluster analysis resulted in three types: 36.5% belonged to Type 1 (high forefoot and high midfoot), 31.1% belonged to Type 2 (high forefoot and low midfoot), and 32.4% belonged to Type 3 (low forefoot and high midfoot). The distribution was relatively even. For the sole, 8 factors were extracted (ball width and medial foot protrusion, lateral foot protrusion, forefoot and hindfoot length ratio, ball gradient, heel size, toe breadth, lateral ball length, and foot length) and a cluster analysis resulted in three Types (Type H, Type D, and Type A). The largest proportion (42.7%) belonged to Type H, which is the same as the elderly men's case.

The Comparison of Foot Shape Classification Methods (발 형태 분류 방법 비교 연구)

  • Choi, Sun-Hui;Chun, Jong-Suk
    • The Research Journal of the Costume Culture
    • /
    • v.15 no.2 s.67
    • /
    • pp.252-264
    • /
    • 2007
  • The purpose of this study was to compare two analytical methods classifying foot shape. The methods compared were cluster analysis method and foot index analysis method. This study defined the women's foot shape by these methods. 39 foot measurements which were automatically collected using the three dimensional foot scanner were analyzed. 203 Korean women in age 20s were participated in the anthropometric survey. Their foot shapes were classified into 5 foot types by cluster analysis: short & slim shape, flat shape, short & slender shape with slightly distorted toe, long and big shape, and short & wide shape. The foot measurements were also analyzed by the ratio of foot width and length. Five foot types that were classified by cluster analysis and three foot types that were classified by the foot index were compared. The comparison shows that cluster analysis precisely defined foot shapes. It was suggested that made-to-measure shoes making industry may adopt the foot shape analysis method utilizing cluster analysis.

  • PDF

Classification of Elderly Men's Sole from the 2D Scanning Method

  • Kim, Nam Soon;Do, Wol Hee
    • Fashion & Textile Research Journal
    • /
    • v.15 no.3
    • /
    • pp.414-422
    • /
    • 2013
  • This study identifies the foot shapes of elderly men by classifying foot types according to the shapes of sole of foot and analyzing individual characteristics. The subjects were 269 elderly men over 60 years of age. Their right feet were measured indirectly with a 2D scanner. The anthropometric measuring items consisted of 38 items that were estimated on the right foot of each subject. The 2D scan data were analyzed by various statistical methods such as factor analysis, ANOVA and cluster analysis using the statistical program SPSS 19.0. A total of 8 factors were extracted through a factor analysis and these factors represent 77.83% of total variance. The 8 factors were: ball and lateral foot protrusion, ball gradient, medial foot protrusion, anterior and posterior foot length ratio, lateral ball length, heel size, toes breadth, and foot length, that explained 77.83% of the total variance. A total of 4 clusters (as their sole type) were categorized using 8 factor scores by cluster analysis. Type 1 was classified as H-type(toes width, foot width, heel width uniform and medial malleolus and lateral malleolus almost no protrusion). Type 2 was classified as V-type(foot width and toes width, wide and heel width narrow). Type 3 was classified as A-type(foot width and heel width, wide but toes width narrow, protruded inside). Type 4 was classified as D-type(protruded outside).

Development of a Noncontact Three Dimensional Foot Form Measurement System with Optical Triangulation (광삼각법을 이용한 비접촉 3차원 족형 측정 시스템 설계)

  • 박인덕;안형회;송강석;이희만;김시경
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.5
    • /
    • pp.368-373
    • /
    • 2003
  • This paper presents a cost-effective 3D foot scanner system that provides the 3-dimensional point cloud foot data to design the custom footwear. To measure the 3-dimensional point cloud data of the foot, a CCD camera, a Non-Gaussian laser line projector and optical triangulation method are employed. Furthermore, the integrated system employs a measurement base, a frame grabber, a CCD moving cart, a stepping motor and a computer. The measurement result is saved as 3D dxf format and it could be converted to 2D essential data fer a shoe design. The experimental results demonstrate that the proposed system have the decent resolution of 1mm which is enough for last and shoe design.

The Study on the Foot Type of Female Farmers (여성 농업인 발 유형에 관한 연구)

  • Jung, Myoung-Sook;Hwang, Kyoung-Sook
    • Journal of the Korean Society of Costume
    • /
    • v.62 no.1
    • /
    • pp.76-89
    • /
    • 2012
  • This study was performed to offer the basic data for the design of farm shoes. 265 Korean female farmers aging between the 40s to the 80s volunteered for this study and we measured 40 items on each foot with the 3D foot scanner. First, the differences between farmers' feet and non-farmers' feet were analyzed. Farmers' feet were thicker in the instep areas, but had lower arch height than non-farmers' feet. In addition, farmer's feet were tilted to the inside. Next, eight factors were extracted among the 40 measuring items, and the classification criteria of the foot shape was analyzed. The important factors were: size of foot length and volume of ankle, malleolus height and size, volume of the front part of ankle, medial & lateral ball width, and vertical size of foot. Third, three clusters according to the foot shapes were categorized by cluster analysis of eight factor scores. Foot type 1 was medium in foot length, big in thickness, large in lateral ball width, small in toe 1 angle, and tilted to the inside. Foot type 2 was long and slim, and big in toe 5 angle. Foot type 3 was short in foot length, medium in volume of the front part of ankle, large in medial ball width, and big in toe 1 angle. Despite its shortness, foot type 3 was thick and showed severe deformation in toe 1. Lastly, the frequency distributions of the foot types in each age group were analyzed. Female farmers of the forties showed high frequency in type 1 and other age groups showed high frequency in type 2. The older female farmers showed higher frequency of type 3.

Classification of Elderly Men's Foot Side Type from 3D Scan Data (3차원 스캔 데이터에 의한 노년 남성의 발 측면유형 분류)

  • Kim, Nam-Soon;Do, Wol-Hee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.38 no.4
    • /
    • pp.427-439
    • /
    • 2014
  • This study identifies the foot side shapes of elderly men by classifying foot types according to 3D foot shapes and analyzing individual characteristics. The subjects were 284 elderly men over 60 years of age who lived in Gwangju and did not have foot related diseases. They were measured with a scanner (Nexcan$^{(R)}$ of K&I Technology) to obtain three dimensional feet shapes. Anthropometric measuring items consisted of 28 items estimated on the right foot of each subject. 3D scan data were analyzed by various statistical methods such as factor analysis, ANOVA and cluster analysis using the statistical program SPSS 19.0. A total of 7 factors were extracted through a factor analysis and these factors represent 77.56% of total variance. The 8 factors were: inside height and side gradient, ankle thickness, size from foot center to ankle, lateral malleolus height, forefoot height, instep and heel height and gradient. A total of 3 clusters (as foot type) were categorized using 7 factor scores by cluster analysis. Type 1 was classified as high forefoot and low midfoot compared to the length. Type 2 was classified as low forefoot and high midfoot, and type 3 was classified as low forefoot and low midfoot.

Correlation between Chronic Ankle Instability and Center of Pressure Using Pedobrarograph (족압검사를 이용한 만성 발목 불안정성과 압력중심의 연관성)

  • Park, Eun Soo;Seo, Sang Gyo;Lee, Ho Seong
    • Journal of Korean Foot and Ankle Society
    • /
    • v.24 no.1
    • /
    • pp.14-18
    • /
    • 2020
  • Purpose: Chronic ankle instability is a very common abnormality of the ankle, but there is still controversy regarding its evaluation criteria. The stress view has difficulties in reflecting the patient's symptoms and treatment progress. Therefore, this study examined the relationship between the center of pressure (COP) measured by a pedobarograph and the symptoms of the patient. Materials and Methods: Thirty patients with chronic ankle instability from February to August 2018 were included. Each patient was surveyed with the foot and ankle outcome score (FAOS). The COP was measured with a foot pressure scanner, and the travel distance and ellipse area of the COP were calculated. Each patient was measured on one foot and on two feet with his or her eyes closed and open. The relationship between the COP measurement and FAOS score was analyzed using the Pearson correlation coefficient. Results: The participants were consisted of 21 male and nine female, with a mean age of 30 years, mean weight of 72 kg, and mean foot size of 259 mm. With the eyes open, the correlation coefficient between the FAOS and travel distance of the affected side was -0.394 (p<0.05) and that between the FAOS and the ellipse area of the affected side was -0.425 (p<0.05). On the other hand, no significant correlations were found between the travel distance and ellipse area of the affected side when patients closed their eyes. Conclusion: Measurement of the COP using foot pressure scanner could evaluate objectively patients with chronic ankle instability, with measurements in patients with their eyes open being more significant. Based on the findings of this study, an analysis of the COP with the patients with their eyes open and standing on one foot may help determine the management strategy and assess the progress of the patients.

The Relationship between Shoe Wearing Trait and Foot Shape of Women in Their Twenties (20대 여성의 구두 착용 특성과 발 유형의 관계)

  • Choi, Sun-Hui;Chun, Jong-Suk
    • The Research Journal of the Costume Culture
    • /
    • v.17 no.1
    • /
    • pp.68-75
    • /
    • 2009
  • The purpose of this study is to find the relationship between women's shoes wearing trait and their foot shape. 203 women in their twenties were participated in the experiment. The subjects' feet were measured with a 3D foot scanner and their foot shapes were classified into five types by factor analysis and cluster analysis in the previous study. In addition to the five foot types, three foot types classified by foot index were also utilized for this study. This study analyzed the trait of their shoe wearing and the areas of discomfort on the foot when they wore shoes. The results of the experiment show that the size of shoe size-foot size mismatching and the foot areas of discomfort wearing shoes were differentiate by foot types. It shows that the subjects with long foot, wide fore foot shape, or fore foot angle deformity wore larger size shoes than their foot size. The foot areas of discomfort with wearing shoes were different according to the foot types. Subjects with wide fore foot shape or fore foot angle deformity had discomfort at the front shoe area. The subjects with straight toes had the least discomfort. The foot discomfort areas differentiated according to foot index type. The foot types with wide ball width experienced discomfort at the front of the ball and the top of the foot.

  • PDF