• 제목/요약/키워드: foot measurement experiments

검색결과 18건 처리시간 0.026초

Survey of Shoes Wearing Reality and Old Males Foot Types

  • Shim, Boo-Ja;Yoo, Hyun
    • 패션비즈니스
    • /
    • 제11권3호
    • /
    • pp.1-14
    • /
    • 2007
  • This research to reveal the foot types of old males consisted of two parts. First, a questionnaire was given for 180 old men in their 60s and above who live in Busan. Second, based on this survey on the reality of shoes wearing, direct and indirect measurement were held for 200 old gentlemen. The findings are as follows: 1. Survey Results of Shoes Wearing Reality In the investigation into the reality of shoes possession and wearing, most of old males favored active casual shoes with comfortable materials (40.8%). Hardened skin (23.6%) was the greatest in foot deformation and side effects resulting from shoes wearing, while the big toe (20.1%) was most uncomfortable. The greatest requirement for comfortable shoes was shoes making feet comfortable with a good sense of wear (41.0%), followed by shoes with the soft sole to absorb shock (31.7%), shoes with diverse sizes according to shoes width (13.7%), and shoes made of soft materials in consideration of various foot shapes. 2. Results of Foot Measurement Experiments Busan's males in their 60s and above were 166.31cm (Height), 63.51kg (weight), 23.94cm (foot length), 9.75cm (foot width), and 24.26cm (instep girth). The big toe angle of old males was $11.22^{\circ}$ and the little toe angle $14.70^{\circ}$. Four foot types were classified: 1 (long big foot), 2 (small inside-developed foot), 3 (toe-tip-gathered foot), and 4 (thin flat foot).

Shoe Recommendation System by Measurement of Foot Shape Imag

  • Chang Bae Moon;Byeong Man Kim;Young-Jin Kim
    • 한국컴퓨터정보학회논문지
    • /
    • 제28권9호
    • /
    • pp.93-104
    • /
    • 2023
  • 현대 사회의 서비스 방식은 대면 방식보다 비대면 방식을 선호하는 추세이다. 하지만 신발과 같이 상품을 추천하는 서비스는 대면 방식의 서비스가 불가피하다. 본 논문에서는 비대면 서비스를 목적으로 자동으로 발의 사이즈를 측정하고, 측정 결과를 기반으로 신발을 추천하는 시스템을 제안한다. 제안방법의 성능을 분석하기 위해 사이즈 측정 오차율과 추천성능을 분석하였다. 추천성능 실험에 사용한 방법은 총 10가지이고, 이의 방법 중 가장 좋은 성능을 보이는 추천 방법을 시스템에 적용하였다. 오차율에 대한 실험결과, 사이즈 관련 오차가 작음을 알 수 있었고, 추천성능에 대한 실험결과, 추천에 대한 유의한 결과를 도출할 수 있었다. 본 논문에서의 제안방법은 실험실 수준으로 향후 실제 환경으로 확대 적용할 필요가 있다.

발 보조기 착용이 요통환자의 골반 변위와 통증 변화에 미치는 영향 (The Effect of Low Back Pain and Pelvic Displacement on Foot Orthosis)

  • 이완희;박대성
    • 대한물리치료과학회지
    • /
    • 제12권4호
    • /
    • pp.57-67
    • /
    • 2005
  • The purpose of this study is to investigate the effect of low back pain(LBP) and pelvic displacement on foot orthosis. Before and after experiments were designed to compare the effect. 21 LBP patients who were the subjects diagnosed of applying foot orthosis for 3 weeks after, investigated about pelvic obliquity angle, displacement of ilium, lumbo-sacral angle by x-ray test which is one of pelvic displacement tests, visual analogue scale is used for LBP measurement. The result show the followings; First, Pelvic obliquity angle was significantly reduced after applying foot orthosis compared before using it(p<.05). Second, Displacement of ilium was significantly reduced after applying foot orthosis compared before using it(p<.05). Third, Lumbo-sacral angle was significantly reduced after applying foot orthosis compared before using it(p<.05). Fourth, LBP was significantly reduced after applying foot orthosis compared before using it(p<.05). This study tries to suggest new LBP treatment to reduce pelvic displacement by apply foot orthosis. In conclusion, foot orthosis reduces pelvic obliquity angle, displacement of ilium, lumbo-sacral angle and also decrease LBP. Further more, It needs of biomechanical study which can recognize relation between foot arch and pelvic displacement. This study will serve as a clinically useful data for diagnosis and treatment of LBP and biomechanical analysis of lower limb.

  • PDF

압력분포 측정시스템의 개발 (Development of a Pressure Distribution Measurement System)

  • 정진호;이기원;김영호
    • 대한의용생체공학회:의공학회지
    • /
    • 제21권2호
    • /
    • pp.213-218
    • /
    • 2000
  • Pressure distributions of the soft tissue are valuable for understanding and diagnosing the disease characteristics due to the mechanical loading. Our system measures dynamic pressure distributions in real-time under the general PC environment, and analyzes various foot disorders. Main features of the developed system are as follows: (1) With the resistive pressure sensor matrix of 40${\times}$40 cells, the data is sent to the PC with the maximum sampling rate of 40 frames/sec. (2) For each frame, contact area, pressure and force are analyzed by graphic forms. Thus, various biomechanical parameters are easily determined at specific areas of interests. (3) A certain stance phase can be chosen for the analysis from the continuous walking, and the detailed biomechanical analysis can be done according to an arbitrary line dividing anterior/posterior or medial/lateral plantar areas. (4) The center of pressure (COP) is calculated and traced from the pressure distribution data, and thus the movement of the COP is monitored in detail. A few experiments revealed that our system successfully measured the dynamic plantar distribution during normal walking.

  • PDF

The Wearing Sense of Male Adult Shoes - Comparison of Common Shoes with Elevated Shoes -

  • Shim, Boo-Ja;Yoo, Hyun
    • 패션비즈니스
    • /
    • 제11권6호
    • /
    • pp.35-51
    • /
    • 2007
  • This research was administered in order to know the effects of heels on the foot by comparing the foot environmental characteristics when common shoes and elevated shoes are worn. First, 157 male adults in their 20s through 40s living in Busan were the inquiry subjects to reveal the shoes-wearing reality of adult males. Second, 7 male adults in their early 20s became the subjects for the experiments of wearing common shoes and elevated shoes. 1. Inquiry Results of Shoes-Wearing Reality Common-shoes wearers were in the order: 20s (43.9%) > 30s (24.8%) > 40s (8.3%). Elevated-shoes wearers were mostly 20s (12.1%), followed by 30s (8.3%) and 40s (2.5%). Among the wearing effects of elevated shoes were 'looking taller' (66.7%), 'no height complex & more confidence' (30.6%), and 'higher work efficiency' (2.8%). In sum, 97.3% of the male subjects believed in great positive effects by wearing elevated shoes. 2. Shoes-Wearing Experiment Results In foot skin temperature, significant differences between the two groups were admitted in outer foot a (p<0.05) and other areas (p<0.001), except in the instep. Elevated-shoes group had bigger skin temperature, while the order of temperature was the instep, the big toe, inner foot a/b/c and outer foot a/b/c. Significant difference was accepted in total sweat rate (p<0.05) and local sweat rate (p<0.01). Elevated-shoes group appeared higher in both rates. Significant difference (p<0.001) between the two groups was recognized in fatigue degrees after wearing, whereas significance (p<0.05) in elevated-shoes group was approved in fatigue before and after exercise. So elevated-shoes group experienced more fatigue, especially after exercise.

시변 상보필터와 보행상태 추정을 이용한 경골의 기울어짐 각도추정 (Estimation of Tibia Angle through Time-Varying Complementary Filtering and Gait Phase Detection)

  • 송석기;우한승;공경철
    • 제어로봇시스템학회논문지
    • /
    • 제21권10호
    • /
    • pp.944-950
    • /
    • 2015
  • Recent studies on ankle-foot prostheses used for transtibial amputees have focused on the adaptation of the ankle angle of the prosthesis according to ground conditions. For adaptation to various ground conditions (e.g., incline, decline, and step conditions), ankle-foot prostheses should first recognize the ground conditions as well as the current human motion pattern. For this purpose, the ground reaction forces and orientation angle of the tibia provide fundamental information. The measurement of the orientation angle, however, creates a challenge in practice. Although various sensors, such as accelerometers and gyroscopes, can be utilized to measure the orientation angles of the prosthesis, none of these sensors can be solely used due to their intrinsic drawbacks. In this paper, a time-varying complementary filtering (TVCF) method is proposed to incorporate the measurements from an accelerometer and a gyroscope to obtain a precise orientation angle. The cut-off frequency of TVCF is adaptively determined according to the human gait phase detected by a fuzzy logic algorithm. The performance of the proposed method is verified through experiments.

운동효과 증진을 위한 Arch Support 효과에 관한 연구 (A Study on the Effect of Arch Support for Improvement of Muscle Activity)

  • 이창민;김진훈;오연주;김대웅
    • 대한인간공학회지
    • /
    • 제27권3호
    • /
    • pp.71-79
    • /
    • 2008
  • Walking shoes for walking and jogging have been used to enjoy lots of leisure time. Functional shoes such as walking shoes have special functions to improve body motility by changing of shoe shapes. The walking shoes could improve the motility by structural transformation of outsole as increase degrees of heel and toe. The study on insoles has not been conducted enough on the contrary of the study of outsole. The purpose of this study is to perform ergonomics analysis whether the Arch Supported insoles have an improving effect of muscle activities or not. Experiments were performed with 6 subjects who are health and haven't experienced any diseases past. EMG(Electromyography) and Foot Pressures were measured repeatedly for 5 seconds at 0 hour, after 1 hour and after 2 hours of walking. Insoles used for experiment are normal insole, insole inserted Arch Support and pad. The electrodes for EMG measurement were set on waist (erector spinae), and thigh (vastus lateralis), calf (gastrocnemius). Evaluations of EMG were analyzed by shift of MF (Median Frequency) and MPF (Mean Power Frequency). Foot Pressure was analyzed by mean pressure of feet and change of walking time. As results, Arch Support insole had larger frequency shift value than that of normal insole. Frequency shift between Arch Support insoles and normal insole showed significant difference on 95% confidence interval. And insole 1 has the highest value of frequency shift. For results of foot pressure, Arch Support insoles show continuous decreasing tendency when comparing with normal insoles by changing of times. Also, insole 1 has the highest decreasing value of foot pressure. Therefore, this study presented that the Arch Support insole can promote muscle activities and improves comfort for a prolonged walking.

지능형 발목 근력 보조 로봇의 개발 (Development of an Intelligent Ankle Assistive Robot)

  • 정우철;김창순;박진용;현정근;김정엽
    • 제어로봇시스템학회논문지
    • /
    • 제21권6호
    • /
    • pp.538-546
    • /
    • 2015
  • This paper describes an intelligent ankle assistive robot which provides assistive power to reduce ankle torque based on an analysis of ankle motion and muscle patterns during walking on level and sloped floors. The developed robot can assist ankle muscle power by driving an electric geared motor at the exact timing through the use of an accelerometer that detects gait phase and period, and a potentiometer to measure floor slope angle. A simple muscle assistive link mechanism is proposed to convert the motor torque into the foot assistive force. In particular, this mechanism doesn't restrain the wearer's ankle joint; hence, there is no danger of injury if the motor malfunctions. During walking, the link mechanism pushes down the top of the foot to assist the ankle torque, and it can also lift the foot by inversely driving the linkage, so this robot is useful for foot drop patients. The developed robot and control algorithm are experimentally verified through walking experiments and EMG (Electromyography) measurements.

구두 상부용 가죽의 인장 회복량 측정실험 (Measurement of Tensile Relaxation of Leather for Shoe Uppers)

  • 이정민;배민철;김영우;최승명;백성관;이형욱
    • 융복합기술연구소 논문집
    • /
    • 제7권1호
    • /
    • pp.7-10
    • /
    • 2017
  • In general, the shoe stretcher is utilized to stretching the leather of shoe upper in the longitudinal direction. In the capstone design class, we tried to make a shoe leather stretcher for the ball of foot. Since a natural cow leather was recovered in length according to relaxation time after stretched, it was difficult to predict the initial amount of set up of stretching. In this paper, tensile and relaxation experiments were conducted in order to predict the amount of initial stretching for appropriate tensile length. Apparatus of leather stretching was designed and strains of leather were measured according to relaxation times of 12, 18, 24 hours after stretching of 24 hours. It was revealed that the ratio of the final relaxed strain and the initial applied strain was about 0.404 with R-square of 0.990 for a shoe cow leather.

지반조건과 신발의 종류에 따른 족저압 분포 (Plantar foot pressure distribution depending on ground conditions and shoe type)

  • 김상환;이혜윤;김연덕
    • 한국산학기술학회논문지
    • /
    • 제16권4호
    • /
    • pp.2899-2905
    • /
    • 2015
  • 본 논문은 지반 조건에 따른 족저압의 압력분포에 대한 연구이다. 실내화, 실외화, 걷기화, 운동화의 네 가지 카테고리의 신발이 본 연구에 사용되었으며, 260mm(유럽 코드 EU40)를 착용하는 45명의 20대 남성을 대상으로 콘크리트, 모래 지반에서의 실험을 실시하였다. 보행 시 응력과 압력의 측정은 Techstorm사의 Insole System을 사용하여 측정하였으며 발의 발가락, 전족, 중족, 후족 네 가지 영역에서 족저압을 측정하였다. 연구 결과 신발과 지반 조건에 따라 다른 응력 및 압력의 분포를 나타냈으며 본 연구 결과는 모래 지반에서 착용 가능한 신발의 개발에 유용하게 사용될 것으로 기대된다.