• 제목/요약/키워드: flux-gate

검색결과 51건 처리시간 0.022초

Concept Development of a Simplified FPGA based CPCS for Optimizing the Operating Margin for I-SMRs

  • Randiki, Francis;Jung, Jae Cheon
    • 시스템엔지니어링학술지
    • /
    • 제17권2호
    • /
    • pp.49-60
    • /
    • 2021
  • The Core Protection Calculator System (CPCS) is vital for plant safety as it ensures the required Specified Acceptance Fuel Design Limit (SAFDL) are not exceeded. The CPCS generates trip signals when Departure from Nucleate Boiling Ratio (DNBR) and Local Power Density (LPD) exceeds their predetermined setpoints. These setpoints are established based on the operating margin from the analysis that produces the SAFDL values. The goal of this research is to create a simplified CPCS that optimizes operating margin for I-SMRs. Because the I-SMR is compact in design, instrumentation placement is a challenge, as it is with Ex-core detectors and RCP instrumentation. The proposed CPCS addresses the issue of power flux measurement with In-Core Instrumentation (ICI), while flow measurement is handled with differential pressure transmitters between Steam Generators (SG). Simplification of CPCS is based on a Look-Up-Table (LUT) for determining the CEA groups' position. However, simplification brings approximations that result in a loss of operational margin, which necessitates compensation. Appropriate compensation is performed based on the result of analysis. FPGAs (Field Programmable Gate Arrays) are presented as a way to compensate for the inadequacies of current systems by providing faster execution speeds and a lower Common Cause Failure rate (CCF).

ICP Poly Etcher를 이용한 RF Power와 HBr Gas의 변화에 따른 Polysilicon의 건식식각 (Dry Etching of Polysilicon by the RF Power and HBr Gas Changing in ICP Poly Etcher)

  • 남상훈;현재성;부진효
    • 한국진공학회지
    • /
    • 제15권6호
    • /
    • pp.630-636
    • /
    • 2006
  • 플래시 메모리 반도체의 고집적화와 고밀도화가 진행함에 따라 플래시 메모리의 트랜지스터 안 선폭을 중심으로 게이트 패턴의 미세화가 진행 중이다. 최근 100 nm 이하의 선폭을 구현하기 위해서 ONO(oxide-nitride-oxide)를 사용하기 위한 연구가 개발 중이고, 이러한 100 nm이하의 미세 선폭으로 갈수록 식각 속도와 식각의 프로파일은 중요한 요인으로 작용하고 있다. ICP 식각 장비를 이용하여, power를 50 W 증가 하였을 때, 각각 식각 속도와 포토레지스트와의 선택비를 확인 한 결과 platen power를 100 W로 올렸을 경우 가장 좋은 결과를 나타내었다. 100 W에서 HBr가스의 유량에 변화를 주었을 경우 가스의 양을 증가 할수록 식각 속도는 감소하였지만, 포토레지스트와의 선택비는 증가함을 보였다. 유도결합 플라즈마 식각 장비를 가지고 platen power를 100 W, HBr gas를 35 sccm 공급하여 하부 층에 노치가 형성이 안되고, 식각 속도 320 nm/min, 감광액과의 선택비 3.5:1, 측면식각 프로파일이 수직인 공정 조건을 찾았다.

반폐쇄된 무안만에서 부유물질의 계절적 변동 및 운반양상 (Seasonal Variation and Transport Pattern of Suspended Matters in semiclosed Muan Bay, Southwestern Coast of Korea)

  • 류상옥;김주용;유환수
    • 한국지구과학회지
    • /
    • 제21권2호
    • /
    • pp.128-136
    • /
    • 2000
  • 반폐쇄된 무안만에서 동계와 하계 동안 부유물질의 변동 및 이동양상을 규명하기 위해 염분과 조류, 부유물질의 특성이 조사되었다. 무안만에서 부유물질 함량은 계절적으로 크게 변하여 동계에 낮고 수직적으로 균질한 반면, 하계에 높고 수직적으로 성층화되는 경향을 보였다. 특히, 하계에는 영산강하구언의 갑문조작에 따라 유입되는 담수와 부유물질이 남쪽을 따라 흐르던 연안류가 약화되면서 북측으로 확산되는 경향을 보였다. 또한, 부유물질의 잔여이동은 서측 만입구에서는 하구언과 방조제 건설에 따라 창조류의 지속시간이 길어지면서 계절에 무관하게 만 내로 유입되는 경향을 보인 반면, 남측 만입구에서는 낙조우세와 서측 만입구에서 조석의 비대칭 현상에 의해 만 외부로 유출되는 경향을 보인다. 부유물질의 잔여이동량은 서측 만입구에서 0.0078kg/m ${\cdot}$ sec, 남측 만입구에서 -0.0955kg/m ${\cdot}$ sec로 무안만이 전반적으로 침식되는 경향을 보였으며, 이와 같은 침식현상은 만 내의 조간대를 중심으로 진행된 것으로 여겨진다.

  • PDF

PCB 다층 적층기술을 이용한 마이크로 플럭스게이트 자기 센서 (Micro fluxgate magnetic sensor using multi layer PCB process)

  • 최원열;황준식;최상언
    • 센서학회지
    • /
    • 제12권2호
    • /
    • pp.72-78
    • /
    • 2003
  • 본 논문은 마이크로 플럭스게이트 자기 센서 (micro fluxgate magnetic sensor)의 여자코일 선폭에 따른 자계 검출 특성 변화에 관한 것이다. 센서 제작을 위해 PCB 다층 적층기술을 사용하였으며, 연자성 코어를 둘러싼 여자코일 선폭을 각각 $260\;{\mu}m$$520\;{\mu}m$로 센서를 구현하였다. 센서는 모두 5층의 기판을 적층 하였으며, 가운데 (3번째)기판을 자성체 코어로, 자성체 코어 외부 (2번째와 4번째)기판을 여자코일로, 최외부 (1번째와 5번째)기판을 검출코일로 제작하였다. 연자성 코어로는 약 100,000의 큰 DC 투자율 (permeability)을 갖는 코발트 (Co)가 주성분인 아몰퍼스 재료를 사용하였으며, 자속 누설을 최소화하기 위해 사각 링 형태를 유지하였다. 솔레노이드 형태의 여자코일과 검출코일은 구리 재질로 제작되었다. $260\;{\mu}m$ 여자코일 선폭을 갖는 자기센서는 여자조건이 360 kHz, $3\;V_{p_p}$의 정현파일 경우에 780 V/T로 매우 우수한 감도를 보이고 있으며, $-100\;{\mu}T\;{\sim}\;+100\;{\mu}T$ 영역에서 매우 우수한 선형특성을 보이고 있다. 자기 센서의 크기는 $7.3\;{\times}\;5.7\;mm^2$이며, 소비전력은 약 8 mW이다. 이런 초소형 자기센서는 휴대용 네비게이션 시스템, telematics, VR 게임기 등 다양한 응용분야에 적용할 수 있다.

새만금 내부개발이 체류시간 및 수질변화에 미치는 영향 (Impacts on Residence Time and Water Quality of the Saemangeum Reservoir Caused by Inner Development)

  • 유상철;서승원;이화영
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제15권3호
    • /
    • pp.186-197
    • /
    • 2012
  • 새만금호 내부개발에 따른 호 내측의 수리특성과 수질환경 영향을 분석하기 위해 EFDC 모형을 이용한 심층적인 수치모의가 수행되었다. 개발이 진행되면서 방수제 및 준설 영향으로 표 저층간의 흐름특성이 변화된다. 특히 관리수위 적용에 따른 제한적인 배수갑문 운영은 기존과 다르게 표 저층간 성층발달을 심화시켜 새만금호 내측의 수질환경을 악화시키는 주요 인자로 확인되었다. 무작위행보에 의한 입자추적방법을 이용한 내부 체류시간 분석을 통해 확인된 특성은 평수시와 홍수시 그 특성이 크게 다르지만, 만경호 북측구역은 일종의 사대로 변화되어 오염물질이 장기간 체류되면서 침적된 저니층의 용출로 인해 수질환경이 악화되는 주요 원인으로 작용할 것으로 추론되었다.

Pulsed Ferrite Magnetic Field Generator for Through-the-earth Communication Systems for Disaster Situation in Mines

  • Bae, Seok;Hong, Yang-Ki;Lee, Jaejin;Park, Jihoon;Jalli, Jeevan;Abo, Gavin S.;Kwon, Hyuck M.;Jayasooriya, Chandana K.K.
    • Journal of Magnetics
    • /
    • 제18권1호
    • /
    • pp.43-49
    • /
    • 2013
  • A pulsed ferrite magnetic field generator (FMFG) was designed for the use in the 1000 m long through-the-earth (TTE) communication system for mining disaster situations. To miniaturize the TTE system, a ferrite core having 10,000 of permeability was used for the FMFG. Attenuation of the magnetic field intensity from the FMFG (200-turn and 0.18 m diameter) was calculated to be 89.95 dB at 1000 m depth soil having 0.1 S/m of conductivity. This attenuation was lower than 151.13 dB attenuation of 1 kHz electromagnetic wave at the same conditions. Therefore, the magnetic-field was found to be desirable as a signal carrier source for TTE communications as compared to the electromagnetic wave. The designed FMFG generates the magnetic field intensity of $1{\times}10^{-10}$ Tesla at 1000 m depth. This magnetic field is detectable by compact magnetic sensors such as flux gate or magnetic tunneling junction sensor. Therefore, the miniature FMFG TTE communication system can replace the conventional electromagnetic wave carrier type TTE system and allow reliable signal transmission between rescuer and trapped miners.

조력발전소 가동 후 시화호 내 조간대의 면적 변화 (The Intertidal Area in Lake Sihwa After Operation of the Tidal Power Plant)

  • 김민규;구본주
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제18권4호
    • /
    • pp.310-316
    • /
    • 2015
  • 본 연구의 목적은 시화호 조력발전소 가동 후에 새롭게 형성된 시화호 조간대의 면적과 시기별 면적변화를 분석하는 것이다. 조간대 면적 분석을 위해 원격탐사기법을 이용하여 수치표고모델(Digital Elevation Model, DEM)을 추출하여 14.4 cm의 root mean square (rms) 오차를 갖는 정밀한 수준의 자료를 생산하였다. 시화호 조간대의 면적은 1910년대에는 $165.1km^2$, 방조제 완공 전인 1991년에는 $115.2km^2$, 2010년의 배수갑문 운영시기에는 $5.6km^2$, 조력발전소 가동 후인 2013년에는 $20.3km^2$의 시기별 변화를 보였다. 시화호 조간대는 시화방조제가 완공된 후에 거의 소멸되었으나, 2012년에 조력발전소가 가동되면서 규칙적인 조석환경 형성과 해수 유동량 증가로 인해 그 넓이가 크게 증가되었다. 조력발전소의 가동으로 형성된 시화호 조간대는 유례를 찾기 힘든 조간대 복원의 좋은 예이며, '훼손된 생태계 복원'의 전형적인 사례로서 활용될 수 있을 것이다.

$Cl_2/BCl_3$/Ar 유도 결합 플라즈마에서 온도에 따른 $ZrO_2$ 박막의 식각 (Temperature Dependence on Dry Etching of $ZrO_2$ Thin Films in $Cl_2/BCl_3$/Ar Inductively Coupled Plasma)

  • 양설;김동표;이철인;엄두승;김창일
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.145-145
    • /
    • 2008
  • High-k materials have been paid much more attention for their characteristics with high permittivity to reduce the leakage current through the scaled gate oxide. Among the high-k materials, $ZrO_2$ is one of the most attractive ones combing such favorable properties as a high dielectric constant (k= 20 ~ 25), wide band gap (5 ~ 7 eV) as well as a close thermal expansion coefficient with Si that results in good thermal stability of the $ZrO_2$/Si structure. During the etching process, plasma etching has been widely used to define fine-line patterns, selectively remove materials over topography, planarize surfaces, and trip photoresist. About the high-k materials etching, the relation between the etch characteristics of high-k dielectric materials and plasma properties is required to be studied more to match standard processing procedure with low damaged removal process. Among several etching techniques, we chose the inductively coupled plasma (ICP) for high-density plasma, easy control of ion energy and flux, low ownership and simple structure. And the $BCl_3$ was included in the gas due to the effective extraction of oxygen in the form of $BCl_xO_y$ compounds. During the etching process, the wafer surface temperature is an important parameter, until now, there is less study on temperature parameter. In this study, the etch mechanism of $ZrO_2$ thin film was investigated in function of $Cl_2$ addition to $BCl_3$/Ar gas mixture ratio, RF power and DC-bias power based on substrate temperature increased from $10^{\circ}C$ to $80^{\circ}C$. The variations of relative volume densities for the particles were measured with optical emission spectroscopy (OES). The surface imagination was measured by scanning emission spectroscope (SEM). The chemical state of film was investigated using energy dispersive X-ray (EDX).

  • PDF

급격한 저니토 교란이 인공 하구호 수질에 미치는 영향 (Impacts on Water Quality to an Artificial Lake Due to Sudden Disturbance of Sediments)

  • 서승원;김정훈
    • 한국해안해양공학회지
    • /
    • 제15권1호
    • /
    • pp.39-50
    • /
    • 2003
  • 시화호 북측확장단지 조성을 위하여 반월천과 동화천이 유입되는 상류에서 호안 축조 공사가 진행되는 경우 침적된 오열도가 실한 이 지역에서 저니토가 급격하게 교란될 때 시화호 수질에 미치는 영향을 평가하기 위하여 본 연구를 수행하였다. 3차원 수동역학 모델인 TIDE3D를 수질모델인 CE-QUAL-ICM과 결합하고 4개의 $\sigma$층을 사용하여 수체와 저질사이의 상호작용과 층별 변화를 모의하였다. 1년 이상의 장기적인 수질모의결과, 교란된 지점 인근에서는 저층에만 수질의 악화철상이 나타나고 시화호의 형상 및 외부 하천 유입의 복합적인 특성 상 약 5km를 지나면서 저질 교란의 영향이 표층에 나타난다. 현재의 상황에서는 겨울과 봄에 상류 오염유입이 많아서 COD와 TP수질이 좋지 않으나 이에 비해 저질의 교란으로 야기되는 수질 변화는 여름과 가을에 크게 저하되는 것으로 나타나 현존 상태와 반전된 결과를 제시한다. 선행연구(서 등, 2002)에서 취하였던 격자망보다 배정밀도로 상세화 하여 150m${\times}$150m의 격자에서 수치실험 한 결과는 계산시간의 증대를 유발하지만, 격자의존도가 수치해에 미치는 영향이 있는 것으로 판단되며 특히 유동이 배수갑문 인근의 영역에서 신을 통과하는 유량의 차이를 줄여 만족스러운 결과를 제공한다.

하구둑이 낙동강 하구 표층 퇴적물 생규소(BSi) 분포에 미치는 영향 (The Impact of Nakdong Estuarine Barrage on Distribution of Biogenic Silica (BSi) in Surface Sediment)

  • 김윤지;안순모
    • 한국해양학회지:바다
    • /
    • 제22권4호
    • /
    • pp.172-186
    • /
    • 2017
  • 본 연구는 하구둑으로 인한 육상으로 부터의 규소(Si) 플럭스의 변화가 하구 및 연안생태계에 미치는 영향을 알아보기 위한 사전연구로, 하구둑이 존재하지 않는 섬진강 하구와 하구둑이 존재하는 낙동강 하구 표층퇴적물 및 퇴적물 코어 분석을 통해 하구둑이 입도와 유기물, 그리고 BSi 분포에 어떠한 영향을 미쳤는지 알아보았다. 2014년 11월과 2015년 3월 낙동강과 섬진강 표층 퇴적물의 입도, 유기물, BSi 분포를 조사하였고, 퇴적물 코어를 이용하여 낙동강 하구둑 건설 전 후의 퇴적상의 변화를 알아보았다. 전반적으로 BSi 농도 변화는 퇴적환경에 따른 입도 변화와 좋은 상관관계를 보였다. 자연하구인 섬진강 하구 표층 퇴적물은 상류에서 하류로 갈수록 니질(실트질과 점토질), 유기물, BSi 함량이 점진적으로 증가하였으며, 특히 조석의 영향이 미치는 중부하구 정점부터 그 변화가 뚜렷하게 나타났다. 낙동강 하구 표층 퇴적물은 하구둑을 기준으로 내측과 외측의 입도와 유기물 분포가 뚜렷한 차이를 보였다. 하구둑 내측은 정점 간 차이가 크지 않았으나, 우안배수문 내측은 높은 니질, 유기물, BSi 함량을 보여 하구둑에 의한 물질 정체 현상이 두드러지게 나타났다. 하구둑 외측은 전체적으로 사주 쪽으로 갈수록 표층 퇴적물 내 니질과 유기물, BSi 함량이 감소하는 경향을 보였다. 낙동강 퇴적물 코어 분석 결과, 하구둑 건설 이후 입도와 유기물, BSi 함량이 급격히 감소하였으며, 대규모 공사에 의한 퇴적물 교란 및 하구둑에 의한 물질 유입량 감소가 원인으로 보인다. 우안배수문 인근 정점(ND2) 코어는 을숙도 대교 건설과 우안배수문 증설의 영향으로 약 38 cm 부근에서 퇴적상이 한 번 더 급격히 변하였다. 하구둑으로 인한 물리적 환경의 변화가 BSi 분포에 미치는 영향을 제거하고 정체효과를 보기 위하여 $BSi_{exc}$를 구한 결과, 자연하구인 섬진강 하구는 연구지역의 상류에서 하류로 갈수록 $BSi_{exc}$가 점차 감소하였으며, 중부하구 정점부터 음의 값을 보였다. 낙동강 하구는 하구둑을 기준으로 내측은 양의 값을, 외측은 음의 값을 보였다. 이는 하구둑에 의한 외측의 규소 플럭스 감소와 내측과 외측의 규조 종조성의 급격한 변화 등을 원인으로 볼 수 있다. 우안배수문 외측 정점(ND2) 코어의 $BSi_{exc}$는 하구둑 건설 이후 일정한 음의 값을 보였으며, 이는 낮은 유속으로 인한 니질 퇴적의 증가가 원인으로 판단된다. 그러나 하구둑 건설 이후 $BSi_{exc}$가 크게 변동하였으며, 이는 을숙도 대교 및 우안배수문 건설로 인한 것으로 추정된다.