• 제목/요약/키워드: flux decline

검색결과 97건 처리시간 0.026초

Effects of Surface Modification of the Membrane in the Ultrafiltration of Waste Water

  • Cho Dong Lyun;Kim Sung-Hyun;Huh Yang Il;Kim Doman;Cho Sung Yong;Kim Byung-Hoon
    • Macromolecular Research
    • /
    • 제12권6호
    • /
    • pp.553-558
    • /
    • 2004
  • An ultrafiltration membrane (polyethersulfone, PM 10) was surface-modified by treating it with low-tem­perature plasmas of oxygen, acrylic acid (AA), acetylene, diaminocyolohexane (DACH), and hexamethyldisiloxane (HMDSO). The effects that these modifications have on the filtration efficiency of a membrane in waste water treat­ment were investigated. The oxygen, AA, and DACH plasma-treated membranes became more hydrophilic. The water contact angles ranged from < $10^{\circ}\;to\;55^{\circ}$ depending on the type of plasma and the treatment conditions. The oxygen plasma-treated membranes displayed a higher initial flux $(312-429\%),$ but lower rejection $(6-91\%),$ than did an untreated membrane. The AA plasma-treated membranes displayed lower or higher initial flux $(42-156\%),$ depending upon the treatment conditions, but higher rejection $(224-295\%)$ in all cases. The DACH plasma-treated membranes displayed lower initial flux. All of them, especially the AA plasma-treated membrane, displayed improved fouling resistance with either a slower or no flux decline. Acetylene and HMDSO plasma-treated membranes became more hydrophobic and displayed both lower initial flux and lower fouling resistance.

Reuse of treated wastewater from steel industry by reverse osmosis membrane: flux decline study

  • Kwon, Tea-Ouk;Lee, Jae-Wook;Moon, Il-Shik
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 2004년도 Proceedings of the second conference of aseanian membrane society
    • /
    • pp.199-202
    • /
    • 2004
  • Membrane technology is widely employed as a means of producing various qualities of water from surface water, well water, brackish water and seawater. This is also used in industrial wastewater treatment and its recycling process. A large volume of wastewater is generated by the steel industry. Presently, the treated wastewater from the steel industry cannot be recycled, because some of its components cause either direct or indirect problems.(omitted)

  • PDF

Si 함유용액에 의한 한외여과막의 투과유속 감소 특성 (Flux Decline during Ultrafiltration of the Silicon Colloidal Solution)

  • 여호택;이석기;전재홍;남석태;최호상
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1998년도 추계 총회 및 학술발표회
    • /
    • pp.163-165
    • /
    • 1998
  • 한외여과 분리막을 이용한 공정은 화학공업을 비롯하여 의약품, 식품, 폐수 처리 및 반도체산업 등의 여러 분야에서 이용되고 있다. 그러나 한외여과 분리 공정에 잇어서 해결되어야 할 중요한 문제점은 투과유속의 감소현상이다. 용액의 투과유속이 순수의 투과유속보다 낮아지는 투과유속의 감소현상은 크게 농도분극과 막오염 현상에 기인한다. 농도분극에 의한 투과유속의 감소는 보통 1분 이내의 매우 짧은 시간 안에 일어나지만 시간이 지속됨에 따라 투과유속이 감소하는 현상은 막오염에 기인한다.

  • PDF

Performance of fouled NF membrane as used for textile dyeing wastewater

  • Abdel-Fatah, Mona A.;Khater, E.M.H.;Hafez, A.I.;Shaaban, A.F.
    • Membrane and Water Treatment
    • /
    • 제11권2호
    • /
    • pp.111-121
    • /
    • 2020
  • The fouling of Nanofiltration membrane (NF) was examined using wastewater containing reactive black dye RB5 of 1500 Pt/Co color concentrations with 16890 mg/l TDS collected from El-alamia Company for Dying and Weaving in Egypt. The NF-unit was operated at constant pressure of 10 bars, temperature of 25℃, and flowrate of 420 L/min. SEM, EDX, and FTIR were used for fouling characterization. Using the ROIFA-4 program, the total inorganic fouling load was 1.07 mM/kg present as 49.3% Carbonates, 10.1% Sulfates, 37.2% Silicates, 37.2% Phosphates, and 0.93% Iron oxides. The permeate flux, recovery, salt rejection and mass transfer coefficients of the dye molecules were reduced significantly after fouling. The results clearly demonstrate that the fouling had detrimental effect on membrane performance in dye removal, as indicated by a sharp decrease in permeate flux and dye recovery 68%. The dye mass transfer coefficient was dropped dramatically by 34%, and the salt permeability increased by 14%. In this study, all the properties of the membrane used and the fouling that caused its poor condition are identified. Another study was conducted to regeneration fouled membrane again by chemical methods in another article (Abdel-Fatah et al. 2017).

하수처리수 재이용을 위한 막분리 공정시 응집조건에 따른 투과효율 변화에 관한 연구 (A Study on Flux Efficiency on Membrane for Water Reclamination according to Coagulations)

  • 정진희;장성호;최영익
    • 한국환경과학회지
    • /
    • 제20권6호
    • /
    • pp.767-773
    • /
    • 2011
  • The objectives of this research are to investigate the proper coagulation conditions which are a type and doses of coagulants, mixing conditions (velocity gradients and mixing times), pH and so on through Jar-test, to evaluate the flux variations, permeate, backwashing according to characteristics of pretreatment of the wastewater by means of MF membranes for river maintenance water reuse. The effluent water from B-city K-sewage treatment plant are used for this research. Turbidity and suspended solids(SS) are 14.2 NTU and 10.4 mg/L respectively. This condition causes fouling for membrane process. The flux decline could be reduced when coagulation pretreatment was carried out. Optimal coagulations PAC which are commonly used in the sewage treatment plant was observed in this research. The results indicate that an optimal coagulation dose and pH are 80 ppm and pH of 7 respectively, but coagulation efficiency was lower at strong acid or strong base. Results showed that continuous and steady operations in membrane separation process by means of the effective removal of organic matter and turbidity with coagulation pretreatment of sewage secondary effluent were achieved.

PACl 및 Alum 응집제 특성이 정밀여과막 투과수량 및 막오염에 미치는 영향 (Impact of Characteristics of Polymeric Al Coagulants PACl and Alum on Membrane Flux and Fouling of Microfiltration)

  • 진용철;최양훈;권지향
    • 상하수도학회지
    • /
    • 제25권2호
    • /
    • pp.231-240
    • /
    • 2011
  • The objectives of this research are to investigate coagulation efficiencies of two coagulants l.e., alum and polyaluminum chloride and to understand effects of the coagulants on membrane fouling in microfiltration. The turbidity of supernatant from alum coagulation was increased with increasing doses whereas the turbidity from PACl coagulation was maintained at the low values. The observed injection volume of PACl for the same removal was approximately 30 percent less than alum, which produced a low sludge volume. The settling velocity of PACl flocs was greater than alum flocs. The results corresponded well with floc size measurements. Flux decline from alum coagulation was significant due in part to small sizes of flocs. At the low dose, alum floc had less specific cake resistance than PACl floc. However, as the dosage was increased, the increases in specific cake resistances of alum was substantial. Alum coagulation pretreatment needs careful operation to reduce membrane fouling by flocs. In general, PACl coagulants were more effective than alum coagulants for pretreatment of membrane processes because PACl showed the better performance in coagulation and membrane fouling.

Separation and flux characteristics in cross-flow ultrafiltration of bovine serum albumin and bovine hemoglobin solutions

  • Hsiao, Ruey-Chang;Hung, Chia-Lin;Lin, Su-Hsia;Juang, Ruey-Shin
    • Membrane and Water Treatment
    • /
    • 제2권2호
    • /
    • pp.91-103
    • /
    • 2011
  • The flux behavior in the separation of equimolar bovine serum albumin (BSA) and bovine hemoglobin (HB) in aqueous solutions by cross-flow ultrafiltration (UF) was investigated, in which polyacylonitrile membrane with a molecular weight cut-off (MWCO) of 100 kDa was used. BSA and HB have comparable molar mass (67,000 vs. 68,000) but different isoelectric points (4.7 vs. 7.1). The effects of process variables including solution pH (6.5, 7.1, and 7.5), total protein concentration (1.48 and 7.40 ${\mu}M$), transmembrane pressure (69, 207, and 345 kPa), and solution ionic strength (with or without 0.01 M NaCl) on the separation were examined. It was shown that the ionic strength had a negligible effect on separation performance under the conditions studied. Although BSA and HB are not rigid bodies, the flux decline in the present cross-flow UF did not result from the mechanism of cake filtration with compression. In this regard, the specific cake resistance when pseudo steady-state was reached was evaluated and discussed.

Understanding the physical environment of relativistic jet from 3C 279 using its spectral and temporal information

  • Yoo, Sung-Min;Lee, Sang-Sung;An, Hongjun;Kim, Sang-Hyun;Lee, Jee Won;Hodgson, Jeffrey A.;Kang, Sincheol
    • 천문학회보
    • /
    • 제44권1호
    • /
    • pp.35.3-35.3
    • /
    • 2019
  • Blazars are a subclass of active galactic nuclei (AGNs) with relativistic jets aligned with our line of sight. The jet physics is yet to be understood, but can be studied with blazar variability (e.g., flares). The highly variable blazar 3C 279 has shown a general decline of its radio flux density since 2013, but the flux density has been increasing since 2017. To better understand physical properties of 3C 279 related with the flux variations, we analyze multi-frequency new radio data obtained with Korean VLBI Network (KVN), as well as archival data from Owens Valley Radio Observatory (OVRO) and Submillimeter Array (SMA). We measure the radio spectral variability and infer the relativistic jet properties of 3C 279. The high-cadence OVRO and SMA observations are used to construct detailed light curves of the source, and KVN data supplement the spectral coverage and allow us to locate the spectral break frequencies precisely. In this talk, we present our analysis results and interpret them using a blazar jet model.

  • PDF

알루미늄 수화물 나노여과 막오염에 대한 공존염의 영향에 관한 연구 (Influence of inorganic compounds on nanofiltration membrane fouling with Al hydrolysis products)

  • 최양훈;권지향
    • 상하수도학회지
    • /
    • 제25권4호
    • /
    • pp.479-488
    • /
    • 2011
  • Nanofiltration was performed with polyaluminium chloride solutions at different pH conditions to understand effects of inorganic compounds on aluminum hydrolysis products, i.e., three distinctive groups of aluminum species: polymeric Al at low pH; $Al(OH)_3$ at neutral pH; and ${Al(OH)_4}^-$ at high pH. The PACl solution was prepared to be approximately 4.0mM and adjusted to the designated pH. The influence of inorganic compounds on Al species fouling was investigated with 4.9mM $CaCl_2$ and 3.5mM $MgSO_4$ because $Ca^{2+}$, $Mg^{2+}$, $Cl^-$, ${SO_4}^{2-}$ are the most common inorganics in the drinking water. NF membrane fouling was measured by flux decline rate. The impact of $CaCl_2$ was not significant on the individual Al hydrolysis products fouling. However, the flux decline rate was drastically changed in the presence of $MgSO_4$. The concentration of particulate matters was considerably increased possibly due to interaction between Al species and ${SO_4}^{2-}$ where $MgSO_4$ was introduced. The particulates were accumulated on the membrane and enhanced the hydraulic resistance of the cake layer. In addition, conductivity removal of the membrane was decreased when Al-hydroxide was dominant due to reduction of membrane surface charge. The rejection of $Ca^{2+}$and $Mg^{2+}$ were considerably different, which implys that composition of inorganics paly a role on conductivity removal.