• Title/Summary/Keyword: fluorescent film

Search Result 84, Processing Time 0.03 seconds

Development of the Imaging Optical System for the 545 nm Fluorescent Plate of X-ray (X선용 545 nm 형광판 결상광학계 개발)

  • Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.2
    • /
    • pp.17-22
    • /
    • 2008
  • To develop an imaging optical system for the 545 nm fluorescent plate of X-ray. Methods: We designed and manufactured a new imaging optical system for the 545 nm fluorescent plate of X-ray by Sigma 2000 program after deciding the design comparison standards referred to Canon CX2-70 model. Results: The characteristics of the new imaging optical system for the 545 nm fluorescent plate of X-ray have the magnification of -0.225x, the image field size of $90mm{\times}90mm$, and the 0.033 mm resolution line width at the 30% MTF value criterion. These mean that the new model has a capability of deciphering for the more large screen and the resolution of deciphering is superior to that of Canon CX2-70 model. Also the image side NA (-0.196) of the new model is about $\sqrt{2}$ times than that (-0.139) of CX2-70 and the object side NA (0.044) of the new model is about 2 times than that (0.022) of CX2-70. These mean that the sensitivity of the film in the new design model is able to be increased to about 4 times and there is the possibility of reducing the bombed time of X-ray to 1/4 times. Conclusions: We could design and manufacture the imaging optical system for the 545 nm fluorescent plate of X-ray having the possibility of reducing the bombed time of X-ray to 1/4 times in comparision to Canon CX2-70 model, the characteristics of which have the image field size of $90mm{\times}90mm$ and the MTF of 30% or more at 15 lines/mm criterion.

  • PDF

Surface Modification of TiO2 Thin Films by N2 Atmospheric Plasma and Evaluation of Photocatalytic Activity (질소 상압플라즈마를 이용한 TiO2 박막의 표면개질 및 광활성 평가)

  • Lim, Gyeong-Taek;Kim, Kyung Hwan;Park, Jun;Kim, Kyoung Seok;Park, Yu Jeoung;Song, Sun-Jung;Kim, Jong-Ho;Cho, Dong Lyun
    • Applied Chemistry for Engineering
    • /
    • v.20 no.4
    • /
    • pp.402-406
    • /
    • 2009
  • $TiO_2$ thin films were surface-modified with atmospheric plasma and their photocatalytic activities were evaluated. The films were deposited on glass plates by dip-coating in a $TiO_2$ sol-gel solution and sintered at various temperatures for various times. Nitrogen plasma was used for the modification and the experiments were carried out varying operational parameters such as discharge power and treatment time. Photocatalytic activity was evaluated based on the degradation efficiency of methylene blue (MB) under irradiation of UV-A and fluorescent light. According to XPS analysis, a little amount of nitrogen was found to be doped in the film surface after the modification. As a result, photocatalytic activity increased under irradiation of UV-A and fluorescent light, especially fluorescent light.

A Study of Real Time Verification System or Radiation Therapy (방사선치료 위치 실시간 검증시스템에 관한 연구)

  • Kim, Y.J.;Ji, Y.H.;Lee, D.H.;Lee, D.H.;Hong, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.164-167
    • /
    • 1997
  • The treatment setup of patients during irradiation is an important aspect in relation to the success of radiotherapy. Imaging with the treatment beam is a widely used method or verification of the radiation field position relative to the target area, prior to or during irradiation. In this paper, Real time digital radiography system was implemented or verification of local error between simulation plan and radiation therapy machine. Portal image can be acquired by CCD camera, image board and pentium PC after therapy Radiation was converted into light by a metal/fluorescent Screen. The resulting image quality is comparable to film, so the imaging system represents a promising alternative to film as a method of verifying patient positioning in radiotherapy. Edge detection and field size measurement were also implemented and detected automatically for verification of treatment position. Field edge was added to the original image or checking the anatomical treatment verification by therapy technicians. By means of therapy efficiency improvement and decrease of Radiation side effects with these techniques, Exact Radiation treatments are expected.

  • PDF

The Electroluminescence Display using fluorescent material thin film (형광체 박막을 이용한 전계발광 표시장치)

  • Hur, Chang-Wu
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.05a
    • /
    • pp.705-708
    • /
    • 2008
  • ZnS는 전기적 에너지를 받으면 전자와 정공이 무수히 발생하며 이들이 평형상태로 갈 때 보다 높은 준위로 여기 되면 빛이 생성 될 수 있다. 전계발광(EL) 표시장치를 제작하기 위하여 일본의 High purity 사의 제품이 비교적 Electron Beam으로 증착하기에 우수하였고, 휘도도 상용화된 800fL에 80% 수준으로 제작과정을 개선하여 더욱 우수한 결과를 얻을 수 있고 본 연구는 Yellow의 경우 650fL의 휘도를 얻었고, Green의 경우 350 fL의 휘도를 얻었다. Electron Beam 제작용으로 자체 제작된 기판 홀더로 막을 제작한 결과 두께 균일도는 6% 내외의 결과로 상당히 우수한 특성을 나타내었다.

  • PDF

Assembly and electrical property of GFP/Cytochrome b562 Fusion Protein ontothe Au Substrate

  • Jeong, Seong-Cheol;Choe, Jeong-U;Lee, Won-Hong;Nagamune, T.
    • 한국생물공학회:학술대회논문집
    • /
    • 2003.04a
    • /
    • pp.630-633
    • /
    • 2003
  • Transfer of an electron from one site to another in a molecular or between molecules and/or electrodes is one of the most fundamental and ubiquitous processes in chemistry, biology and physics. In this study fusion proteins composed by green fluorescent protein(GFP) and cytochrome b562 were used in fabricating molecular array as an electron sensitizer and electron acceptor, Protein formation onto the substrate was performed by the self-assembly technique. The fusion protein film were analyzed using scanning probe microscope(SPM), Surface Plasmon Resornance(SPR) and hybrid STM/I-V. The results suggest that the proposed molecular photodiode can be used as a basic unit of the memory device.

  • PDF

Ultra-thin Film Assembly of a Novel Biomaterial Containing Protein and Functionalized Polymer for Sensor Application

  • Lim, Jeong-Ok;Sohn, Byung-Ki;Huh, Jeung-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.4 no.4
    • /
    • pp.81-87
    • /
    • 1995
  • A novel biomaterial capable of incorporating biotinylated biomolecule has been synthesized. Our strategy is to biotinylate one-dimensional electroactive polymers and use a bridging streptavidin protein on Langmuir-Blodgett (LB) organized films. These copolymers are derivatized with long alkyl chains and biotin moieties to bind, respectively, to the hydrophobic surface and the biotinylated species, through the biotin and streptavidin complexation. We utilize the polymer assembly approach to attach a signal transducing biomolecule biotinylated phycoerythrin (B-PE) into this novel biomaterial by binding the unoccupied biotin binding sites on the bound streptavidin (4 sites total). The pressure-area isotherm of the protein injected monolayer showed area expansion. A characteristic fluorescent emission peak at 576nm was detected from the monolayer transferred onto a solid substrate. These observations demonstrated the promise of the organized thin polymer assemblies for their application to the sensor system.

  • PDF

Interrelation on the Electronic Structure and Spectroscopic-Photoeletric Characteristics in the Cyanine and Merocyanine Dye(II) (Cyanine 및 Merocyanine색소의 분광특성 및 광전특성에 대한 전자구조의 상관관계(II))

  • 손세모
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.13 no.2
    • /
    • pp.1-17
    • /
    • 1995
  • Organic thin film electroluminescene devices were fabricated using by molecularly doped method with N,N`-diphenyl-N,N`-bis(3-methylphenyl)-1,1`-biphenyl-4,4`-diamine(TPD) as a hole transport material, tris(8-quinolinolate) aluminium(III)(Alq3) as an emitting and electron transport agent, fluorescent squarylium(SQ) dye as a dopant, and poly(methylmethacrylate) as polymer materials. A cell structure of ITO/TPD-PMMA/Alq3-dopant/Mg was employed. The EL spectrum covers a wide range of the visible region and orange emission os observed. Two peaks at 520 and 660nm correspond to the emissions 620nm Alq3 and SQ dye, respectively.

  • PDF

Dependence of the Gain Factor of the Reflective Polarizer on the Configuration of Optical Sheets

  • Lee, Byung-Woo;Yu, Mi-Yeon;Ko, Jae-Hyeon
    • Journal of Information Display
    • /
    • v.10 no.1
    • /
    • pp.28-32
    • /
    • 2009
  • The correlation between the optical performance of the reflective polarizer, which is a key optical component for the brightness enhancement of the liquid crystal display (LCD), and the configuration of optical sheets was investigated in a direct-lit CCFL (cold-cathode fluorescent lamp) backlight. The optical gain of the reflective polarizer, the polarization state of the light emitted from each film, and the loss factor for the polarization conversion process occurring in the lower part of the backlight were determined using a phenomenological approach for the polarization recycling process. The present study suggests that the correlation between the optical performance of the brightness enhancement films and the backlight configuration should be carefully considered in the optimization of the backlight structure.

Apparatus for Monitoring Oil Oxidation Using a Plurality of UV Fluorescence Light-reflecting Members (복수 경로를 지닌 자외선 형광측정기를 이용한 오일 산화도 측정장치)

  • Kong, H.;Han, H.G.;Markava, L.V.
    • Tribology and Lubricants
    • /
    • v.26 no.3
    • /
    • pp.167-174
    • /
    • 2010
  • An apparatus for measuring oil oxidation was developed, which is capable of being mounted to mechanical devices for detecting power of fluorescent light reflected from oil in real time as an indication of the oil oxidation. This device has an advantage over conventional fluorescence spectrometers where the thin film is required for the measurement. Clean and used oil samples (mineral and synthetic oils) were tested by the developed apparatus that calculates a fluorescence quantum yield and a light absorption coefficient of the oil based upon the signals from the two light-receiving members and evaluates the degree of oil oxidation of test oils based on the fluorescence quantum yield. Results generally show that the developed device is able to effectively evaluate oil oxidation characteristics on-site in the field.

Characteristics of Outgas from Heated Barrier Rib for POP (PDP용 격벽재의 승온 탈가스 특성)

  • 김선호;주정훈;이석영;이강욱;오상진
    • Journal of Surface Science and Engineering
    • /
    • v.37 no.3
    • /
    • pp.185-190
    • /
    • 2004
  • Plasma Display Panel is a display device emitting fluorescent light from gas discharge between a front and a rear panel sealed together. Front and rear panel have multitude of film layers and barrier ribs in the rear panel has the largest area so releasing various gases and affecting light emitting characteristics and lifetime. The remaining gases in a barrier rib were studied by thermal desorption analysis up to $400^{\circ}C$ and main gases were $H_2$ $H_2$O, CO. During sustaining at $300^{\circ}C$, the outgassing rates from other gases were decreased but$ H_2$ kept constantly increasing until 1 hour, which can be originated from the dissociation of organics remained in the inside of barrier rib material. In $H_2$O, two distinct peaks were observed: desorption from physically adsorbed one at $l00^{\circ}C$ and from chemically adsorbed one $400^{\circ}C$. The result can be utilized in interpretation of electronic and optical characteristics and evacuation process control of PDP