• Title/Summary/Keyword: fluorescent analysis

Search Result 593, Processing Time 0.024 seconds

2.5MHz Zero-Voltage-Switching Resonant Inverter for Electrodeless Fluorescent Lamp (2.5MHz급 무전극 램프 구동용 ZVS 인버터에 관한 연구)

  • Park, D.H.;Kim, H.J.;Joe, K.Y.;Kye, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.339-342
    • /
    • 1996
  • Driving the electrodeless fluorescent lamp, the high ac voltage with high frequency is required. The linear power amplifier has been widely used as a driving circuit of electrodeless fluorescent lamp. However, the low efficiency of the power amplifier causes the driving circuit to be replaced by a PWM switching inverter. In order to use a PWM switching inverter as the driving circuit of an electrodeless fluorescent lamp, the high switching frequency is required. But due to the switching loss at switches of the inverter, the limitation of high switching frequency appears in the inverter. One solution to this limitation is to reduce the switching loss by using the zero voltage switching technique. In this paper, zero voltage switching resonant inverter for driving an electrodeless fluorescent lamp is discussed. The results of analysis about the inverter are presented and the equations for design are established. And the validity of the analyzed results are verified through the experiment.

  • PDF

A study on Properties Condition for the most suitable design of the Ring-shaped electrodeless fluorescent lamp (환형 무전극 형광램프의 최적 설계를 위한 특성조건 분석)

  • Jo, Ju-Ung;Lee, Seong-Jin;Nam, Joong-Hee;Choi, Yong-Sung;Kim, Yong-Kab;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.211-214
    • /
    • 2004
  • The advantage of ring-shaped electrodeless fluorescent lamp is the removal of internal electrodes and heating filaments that are a light-limiting factor of conventional fluorescent lamps. Therefore, the life time of ring-shaped electrodeless fluorescent lamps is substantially higher than that of conventional fluorescent lamps and last up to 60,000 hours and is intended as a high efficacy replacement for the incandescent reflector lamp in many applications. In this paper, maxwell 3D finite element analysis program(Ansoft) was used to obtain electromagnetic properties associated with the coil and nearby structures. The electromagnetic emitting properties were presented by 3D simulation software operated at 250[kHz] and some specific conditions

  • PDF

Electromagnetic Analysis of Induction Coil for Electrodeless Fluorescent lamps (무전극 형광램프를 위한 유도코일의 전자계 해석)

  • 김광수;이종찬;박대희;박성목
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.187-190
    • /
    • 2002
  • The Electrodeless lamp is intended as a high efficacy replacement for the incandescent reflector lamp in many applications. but Increasing awareness of electromagnetic compatibility(EMC) issues in lighting application, the problems of interference generation by electrodeless fluorescent lighting system have been highlighted. In this paper, Maxwell 2D finite element analysis program(Ansoft) is used to obtain electromagnetic properties associated with the coil and nearby structures. and also evaluated Flux B, H by changing the input current.

  • PDF

A study on the accommodation of common LED to shipboard (육상용 LED 램프의 선박 적응력에 관한 연구)

  • Jeong, Ji-Hyun;Park, Hwan-Chul;Kim, Yong-Joo;Seo, Sang-Do;Han, Seung-Jae;Kim, Min-Sok
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.46 no.4
    • /
    • pp.503-508
    • /
    • 2010
  • Common LED (Light Emitting Diode) lamp has many advantages to compare with fluorescent lamp, long life and no pollution matter like the mercury. The LED lamp is a good light source especially for shipboard lighting because of its compact structure which prevents explosion and shock. Also, low maintenance cost is expected due to its longer life time in comparison with conventional lamps. The LED lamp, however, need some estimates that change of voltage and frequency, vibration, moisture on board to definite accommodation of the LED lamp to shipboard. The purpose of this study is to compare physical properties of a fluorescent lamp with one of the common LED lamp so as to analyze accommodation of common LED lamp on board. This study was carried out in two stages. First, temperature, humidity of illumination, voltage, electric current, frequency and electric power were measured by using experimental equipments. Second, a comparative analysis of consumption electric power, annual oil charge, annual CO2 emission and lamp life time, etc of the fluorescent lamp and common LED one was made. As a result of the study, the consumption electric power of fluorescent lamp was 50% higher than one of the common LED lamp. As a result of measuring life time, it was found that life time of common LED lamp was more about 3.5 fold than one of the fluorescent lamp. Considering these results, it's thought that common LED lamp is verified that energy saving is possible and using is possible as substitute for fluorescent lamp on board.

Screening of Green Fluorescent Protein Gene and Sexing by PCR in Bovine Embryos (소 수정란에서 Green Fluorescent Protein 유전자 검색 및 PCR에 의한 성감별)

  • Lee, H. J.;Kang, T. Y.;Rho, G. J.;Chae, Y. J.;Lee, H.;Choe, S. Y.
    • Journal of Embryo Transfer
    • /
    • v.15 no.2
    • /
    • pp.157-165
    • /
    • 2000
  • The efficiency of transgenic livestock production could be improved by early screening of transgene-integration and sexing of embryos at preimplantational stages before trasferring them into recipients. We examined the effciency of multiplex PCR analysis for the simultaneous confirmation of the trasgene and sex during the preimplantational development of bovine embryos and the possibility of green fluorescent protein(GFP) gene as a non-invasive marker for the early screening of transgenic embryos. The GFP gene was microinjected into the male pronuclei of bovine zygotes produced in vitro. The injected zygotes were co-cultured in TCM-199 containing 10% FCS with boving oviductal epithelial cells in a 5% CO2 incubator. Seventeen(13.0%) out of 136 gene-injected bovine zygotes developed by multiplex PCR analysis and the expression of GFP was detected by observing green fluorescence in embryos under a fluorescent microscope. Eight(67%) of 12 embryos at 2-cell to blastocyst stage were positive in the PCR analysis, but only two(11.8%) of 17 blastocysts expressed the GFP gene. Their sex was determined as 7 female and 5 male embryos by the PCR analysis. The results indicate that the screening of GFP gene and sex in bovine embryos by PCR analysis and fluorescence detection could be a promisible method for the preselection of transgenic embryos.

  • PDF

Development of Indocyanine Green and 5-Aminolevulinic Acid Detection System for Surgical Microscope (수술현미경용 다중형광 관측 시스템 연구)

  • Kim, Hong Rae;Lee, Hyun Min;Yoon, Woong Bae;Kim, Young Jae;Kim, Seok Ki;Yoo, Heon;Joo, Jae Young;Kim, Kwang Gi;Lee, Seung-Hoon
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.1
    • /
    • pp.16-21
    • /
    • 2015
  • Indocyanine green(ICG) and 5-aminolevulinic acid(5-ALA) have been widely used to mark blood vessels or tumors. However, fluorescent dye detection systems were designed to use one type of dyes only. In this study, we proposed a detection system capable of detecting Indocyanine green and 5-aminolevulinic acid. Multiple filters and light sources are integrated into a single system. In this study, we performed analysis of fluorescent dyes and configured a detection system. During the analysis, it was found that Indocyanine green and 5-aminolevulinic acid have the maximum intensity at $40{\mu}M$. We designed light source for fluorescent dyes and conducted compatibility test using a commercial surgical microscope. The fluorescent dye detection system was configured based on the experimental results. The developed system successfully detects Indocyanine green and 5-aminolevulinic acid. Therefore, more efficient surgical operations can be achieved using both fluorescent dyes at the same time. We expect that the developed system can increase the survival rate of patients.

Optimization of Gene Transfection Using Fluorescence-Activated Cell Sorter(FACS) Analysis of Green Fluorescent Protein(GFP) (Green Fluorescent Protein(GFP)의 Fluorescence-Activated Cell Sorter(FACS) 분석을 통한 유전자 이입의 최적화)

  • 김태경;박민태;이균민
    • KSBB Journal
    • /
    • v.14 no.3
    • /
    • pp.377-379
    • /
    • 1999
  • In order to improve the transfection efficiency of CHO/dhfr- cells using cationic lipid, optimal concentrations of the cationic lipid($LipofectAmine^{TM}$) and DNA(pEGFP-C1) need to be determined. The use of green fluorescent protein(GFP) gene as a reporter gene facilitated the quantification of transfection efficiency. The green fluorescence intensity of each cell transfected at various lipid-DNA concentrations was measured using fluorescence-activated cell sorter(FACS) analysis. A combination of $2.0{\mu}L$ cationic lipid and 0.4{$\mu}g$ DNA in a well resulted in the highest trasfection efficiency. Taken together, the method using FACS analysis of GFP is simple and fast, facilitating the optimization of transfection.

  • PDF

Current Technology Trends Analysis on the Recovery of Rare Earth Elements from Fluorescent Substance in the Cold Cathode Fluorescent Lamps of Waste Flat Panel Displays (폐디스플레이 CCFL에 존재하는 형광체 내 희토류 원소 회수 기술 동향 분석)

  • Kang, Leeseung;Shin, Dongyoon;Lee, Jieun;Ahn, Joong Woo;Hong, Hyun-Seon
    • Journal of Powder Materials
    • /
    • v.22 no.1
    • /
    • pp.27-31
    • /
    • 2015
  • Flat panel display devices are mainly used as information display devices in the 21st century. The worldwide waste flat panel displays are expected at 2-3 million units but most of them are land-filled for want of a proper recycling technology More specifically, rare earth metals of La and Eu are used as fluorescent materials of Cold Cathode Flourscent Lamp(CCFL)s in the waste flat panel displays and they are critically vulnerable and irreplaceable strategic mineral resources. At present, most of the waste CCFLs are disposed of by land-filling and incineration and proper recovery of 80-plus tons per annum of the rare earth fluorescent materials will significantly contribute to steady supply of them. A dearth of Korean domestic research results on recovery and recycling of rare earth elements in the CCFLs prompts to initiate this status report on overseas research trends and noteworthy research results in related fields.

Flat Fluorescent Lamp(FFL) and Analysis of Optical Efficiency of FFL Lighting (면광원 램프 및 이를 이용한 조명 기기의 효율 특성 연구)

  • Park, Jong-Lee;Lim, Sung-Kyoo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.7
    • /
    • pp.6-12
    • /
    • 2007
  • A flat fluorescent lamp (FFL) developed as a light source for LCD TV backlight was used as a light source for general lighting application and its electro-optical characteristics were measured and evaluated. The channels of FFL were formed from a flat glass at high temperature by using a mold. The performance of FFL with lighting future was shown to improve by optimizing the channel profile of FFL. In this paper, the brightness efficiency of FFL with lighting fixture was evaluated and compared with that of the hot cathode fluorescent lamp (HCFL), the major light source for general lighting. The optical efficiency of FFL with future was shown to be 72.7[1m/W].

Rapid Detection of Fluorescent DNA on Denaturing Polyacrylamide Gel by Using Gel Scanner (겔스캐너를 이용한 변성아크릴아마이드 겔의 형광 DNA 검출)

  • Ku Ja-Hwan;Jeong Ji-Ung;Cho Young-Chan
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.50 no.spc1
    • /
    • pp.228-230
    • /
    • 2005
  • The denature polyacrylamide gel stain silver nitrate is used for routine nucleic acid detection. More sensitive stains, such as Vistra Green, SYBR Green are available to address a broad range of DNA applications requiring lower detection limits in polyacrylamide gel formats. Gel Scanners, laser-scanning instruments, provide sensitive fluorescence detection of DNA gel stains. We established one step fluorescent impregnation enhanced sensitivity with simple, rapid and low cost. We have applied this fluorescent staining procedure for the routine analysis of DNA profiles generated by SSR amplification.