• 제목/요약/키워드: fluorescence sensor

검색결과 136건 처리시간 0.019초

집적화된 Lab-On-a Chip을 위한 광센서의 제작 및 특성 평가 (Development of Photo-sensor for Integrated Lab-On-a-Chip)

  • 김주환;신경식;김용국;김태송;김상식;주병권
    • 한국전기전자재료학회논문지
    • /
    • 제17권4호
    • /
    • pp.404-409
    • /
    • 2004
  • We fabricated photo-sensor for fluorescence detection in LOC. LOC is high throughput screening system. Our LOC screens biochemical reaction of protein using the immunoassay, and converts biochemical reaction into electrical signal using LIF(Laser Induced Fluorescence) detection method. Protein is labeled with rhodamine intercalating dye and finger PIN photodiode is used as photo-sensor We measured fluorescence emission of rhodamine dye and analyzed tendency of fluorescence detection, according to photo-sensor size, light intensity, and rhodamine concentration. Detection current was almost linearly proportional to two parameters, intensity and concentration, and was inversely proportional to photo-sensor size. Integrated LOC consists of optical-filter deposited photo-sensor and PDMS microchannel detected 50 (pg/${mu}ell$) rhodamine. For integrated LOC including light source, we used green LED as the light source and measured emitted fluorescence.

Monitoring of itaconic acid production by a 2-dimensional fluorescence sensor

  • 정상윤;이종일
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2001년도 추계학술발표대회
    • /
    • pp.270-273
    • /
    • 2001
  • The fluorescence sensor is utilized to monitor the complex fluorescence patterns of intra- and extracellular components in cultivation processes. Especially biogenic fluorophores such as proteins and peptides (tryptophan, phenylalanine), coenzymes (FAD, NAD(P)H) and vitamins (riboflavin, pyridoxine) within cells are detected by a fluorescence sensor. In this work a 2-dimensional fluorescence sensor has been used to monitor a production process of itaconic acid by Aspergillus terreus and the on-line monitored spectra data can be con-elated to off-line data measured by a few methods.

  • PDF

2차원 형광센서에 의한 생물공정의 모니터링 (Monitoring of Biological Processes by 2-dimensional Fluorescence Sensor)

  • 이종일;정상윤;서국화
    • KSBB Journal
    • /
    • 제16권5호
    • /
    • pp.493-499
    • /
    • 2001
  • 2차원 형관센서를 이용하여 생물공정을 모니터링하는 기술에 관해 연구하였다. 기존의 광학센서에 비해 2차원 형광센서는 발효공저의 중요한 변수들을 동시에 모니터링하는데 사용될 수 있다. 본 연구에서는 2차원 형광센서를 이용하여 제조합 E. coli, A,. terreus 및 T. vulagis 등의 발효공정을 모니터링하고 미생물의 성장과 생성물의 생성에 대한 형광 스펙트럼의 변화를 정성적으로 비교, 고찰하였다. 2차원 형광센서는 발효공정 이외에도 생물화학반응 및 분리공정에도 쉽게 사용할수 있고 생물공정의 최적화를 도모하는데 이용될 수 있다.

  • PDF

Optical Filter Design for Fluorescence Technique Based Phycocyanin Measurement Sensor Used In Water Treatment Plants

  • Mariappan, Vinayagam;Lee, Sung Hwa;Yang, Seungyoun;Kim, Jintae;Lee, Minwoo
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제10권2호
    • /
    • pp.45-50
    • /
    • 2018
  • Recently the water management department advised the water treatment industry to focus on deploy the chemical free and the environmentally responsible process to adopt on water treatment plants in every country. In this objective, water treatment process started using ultrasonic based phycocyanin extraction with fluorescence measurement techniques to detect the change in the yield of phycocyanin. This paper propose the design of optical filter model for fluorescence technique based immersive optical phycocyanin measurement sensor design. The proposed design uses the multi-wavelength sensor module for irradiating part, and this plays a role of removing a wavelength band other than 590 ~ 620 nm. The preliminary study on immersed phycocyanin sensor, the fluorescence value of picocyanin according to the ultrasonic intensity, treatment time and number of cells was measured using JM phycocyanin module to emulate the proposed design, and were compared performance of the proposed sensor emulation. In this design, the phycocyanin fluorescence value increased about 2.1 ~ 4.7 times as the ultrasonic treatment time increased as compared with JM phycocyanin module, and the phycocyanin fluorescence value within the analysis range was obtained by ultrasonic treatment within one minute.

유전자 재조합 대장균에 의만 5-Aminolevulinic Acid (ALA)의 생산 및 공정 모니터링 II. 2차원 형광센서에 의안 공정 모니터링 (Production and Process Monitoring of 5-Aminolevulinic Acid (ALA) by Recombinant E. coli II. process Monitoring by a 2-Dimensional Fluorescence Sensor)

  • 이종일;정상윤;임용식;정상욱
    • KSBB Journal
    • /
    • 제19권1호
    • /
    • pp.27-32
    • /
    • 2004
  • 본 연구에서는 2차원 형광 센서를 이용하여 ALA 생산 공정을 실시간 모니터링하고 오프라인 분석 데이터와 비교, 고찰하였다. 배양액의 pH나 균체의 성장 특성 등 생물공정내의 환경 변화에 따라 형광 특성에 차이를 보였으며 최소배지인 MS8 배지에 IPTG, LA 및 기질 (포도당, 숙신산) 등을 첨가한 후 형광 특성의 변화를 살펴본 결과 균체의 성장이나 세포내 대사현상의 변화를 형광 차이로부터 확인할 수 있었다 2차원 형광센서에 의해 실시간 모니터링 된 형광 스펙트럼데이터는 기질 및 생산물 그리고 세포내 효소 활성 등의 각종 공정 변수와 좋은 상관성을 보였다. 따라서 본 연구에서 사용한 2차원 형광센서는 ALA 대량 생산을 위해 주요한 공정변수를 실시간 모니터링 하는데 매우 효과적이라 할 수 있으며 향후 공정의 제어 및 최적화에도 이용될 수 있다.

An off-on Fluorescent Sensor for Detecting a Wide Range of Water Content in Organic Solvents

  • Kim, Kang-Hyeon;Lee, Wan-Jin;Kim, Jae Nyoung;Kim, Hyung Jin
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권8호
    • /
    • pp.2261-2266
    • /
    • 2013
  • This paper describes the synthesis and water sensing properties of a fluorescent photoinduced electron transfer (PET) sensor (5) with an extended operating sensing range. The 1,8-naphthalimide derivative (5) attached with a piperazine group and a carboxylic group was synthesized and applied as a fluorescent water sensor in water-miscible organic solvents. The fluorescence intensity of the dye 5 increased with increasing water content up to 80% (v/v) and the fluorescence intensities were enhanced 45-, 67- and 122-fold in aqueous EtOH, DMF and DMSO solutions, respectively. In aqueous acetone solution, the enhancement of the fluorescence intensities was somewhat lower (30-fold) but the response range was wider (0-90%, v/v).

자외선 형광 방출비 평가에 의한 전기 절연유의 산화측정 (Measurement of Electrical Insulating Oil Oxidation by Evaluating the UV Fluorescence Emission Ratio)

  • ;공호성;한흥구
    • Tribology and Lubricants
    • /
    • 제29권1호
    • /
    • pp.51-55
    • /
    • 2013
  • In this work, a new fluorescence emission measurement technology was introduced and experimentally compared with other measurement methods, such as the titration method and IR spectroscopy, to validate it for the oil oxidation measurement of electrical insulating oil. The oxidation characteristics of insulating oil were found to be fairly represented by the titration method and IR spectroscopy, and the results are comparable to a change in the fluorescence emission ratio that is defined as the shift in fluorescence intensity in the measured wavelength range. The result also shows that by the measurement of fluorescence emission ratio, it is possible to detect the oxidation of oil relatively earlier than by other methods. This study suggests that the developed technology can provide sufficient information for evaluating the insulating oil quality, and that the developed FER sensor can be used as an effective condition monitoring device of electrical insulating oil oxidation.

Design of Optical Biological Sensor for Phycocyanin Parameters Measurement using Fluorescence Technique

  • Lee, Sung Hwa;Mariappan, Vinayagam;Won, Dong Chan;Ann, Myungsuk;Yang, Seungyoun
    • International journal of advanced smart convergence
    • /
    • 제5권2호
    • /
    • pp.73-79
    • /
    • 2016
  • Remote sensing and measurement are of paramount importance of providing information on the state of water quality in water bodies. The formation and growth of cyanobacteria is of serious concern to in land aquatic life forms and human life. The main cause of water quality deterioration stems from anthropogenic induced eutrophication. The goal of this research to quantify and determine the spatial distribution of cyanobacteria concentration in the water using remote sensing technique. The standard approach to measure water quality based on the direct measurement of the fluorescence of the chlorophyll a in the living algal cells and the same approach used to detect the phycobilin pigments found in blue-green algae (a.k.a. cyanobacteria), phycocyanin and phycoerythrin. This paper propose the emerging sensor design to measure the water quality based on the optical analysis by fluorescence of the phycocyanin pigment. In this research, we developed an method to sense and quantify to derive phycocyanin intensity index for estimating cyanobacteria concentrations. The development of the index was based on the reflectance difference between visible light band 620nm and 665nm. As a result of research this paper presents, an optical biological sensor design information to measure the Phycocyanin parameters in water content.

The Fluorescent 7-Aminodipyrido[3,2-a:2',3'-c] phenazine(7-amino-dppz) Functionalized as an Europium Ion ($Eu^{3+}$) Sensor

  • Choi, Chang-Shik;Lee, Ki-Hwan
    • Rapid Communication in Photoscience
    • /
    • 제1권2호
    • /
    • pp.31-33
    • /
    • 2012
  • The Fluorescent 7-aminodipyrido[3,2-a:2',3'-c]phenazine (7-amino-dppz, 1) is functionalized as an europium ion ($Eu^{3+}$) sensor, which showed the effective emission quenching when europium cation is chelated to the bpy site of 1 compound. The complexation ratio indicated that the 1 compound forms a 1 : 1 complex with $Eu^{3+}$.