• 제목/요약/키워드: fluidized bed type

검색결과 110건 처리시간 0.026초

Numerical Investigation of Bubble Characteristics in a Two-Dimensional Fluidized Bed

  • Kang, Kyung-Tae;Kook, Jeong-Jin;Park, Seung-Ho
    • 한국연소학회지
    • /
    • 제7권1호
    • /
    • pp.52-57
    • /
    • 2002
  • A numerical investigation using a commercial CFD program of the Inter-Phase Slip Algorithm has been carried out for detail characteristics of particle motions and bubble behaviors in a two dimensional fluidized bed. The bed simulated has been operated with three different distributor geometries, such as bubble cap, nozzle, and perforated plate types. Experiments using a slit-type two-dimensional fluidized bed and a cylinder-type fluidized bed have been performed in order to confirm the simulation model. In addition, the numerical results are compared with the wellknown correlation of bubble sizes and bubble rising velocities by Mori and Wen [1]. The simulation model that we applied is shown to be useful to understand the relation between bubble behaviors and distributor geometries.

  • PDF

유동층에서 기포의 유동특성에 관한 연구 (A Study on the Flow Characteristics of Bubbles in a Fluidized Bed)

  • 김용섭
    • 한국해양공학회지
    • /
    • 제10권3호
    • /
    • pp.117-124
    • /
    • 1996
  • A fluidized bed combustion chamber is widely used to incinerate waste material. The most important factor designing the incinerator is the flow characteristics in a fluidized bed, because combustion efficiency is influenced by the flow characteristics. This paper has invesitigated the flow characteristics of bubbles in fluidized bed by means of meassuring a pressure fluctuation in the fluidized bed. A pressure probe system has used to measure the pressure. The data concerned with bubble rising velocity, bubble size, distribution of bubbles and frequency of bubble generation or decay are obtained to find the flow characteristics of bubbles in the fluidized bed. The result obtained from this experimental study can be used to design the fuel feeding system of fluidized bed combustion type incinerator. And it is possible to predict the mixing of waste material and fluidizing material.

  • PDF

초초임계 순환유동층 보일러 기술 소개 및 현황 (Introduction and Current Status of Ultra Supercritical Circulating Fluidized Bed Boiler)

  • 이시훈;이종민
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권2호
    • /
    • pp.211-221
    • /
    • 2016
  • 전세계의 인구 증가와 경제 발전은 지속적인 에너지 수요의 증가를 가져오고 있다. 특히, 전력부분에서는 아시아 및 아프리카, 그리고 중남미 등의 개발도상국을 중심으로 그 수요가 지속적으로 증가하고 있어 주요 에너지원인 석탄의 이용도 지속적으로 증가할 것으로 예측되고 있다. 그러나, 이산화탄소 및 대기오염원, 그리고 미세먼지 등의 배출 등은 석탄을 이용한 전력생산에 있어 환경친화적인 기술로의 대응방안 마련과 더불어, 고효율의 다양한 저급연료를 활용할 수 있는 발전 기술의 개발이 요구되고 있다. 이에, 기술개발 및 그 상용화 시장이 점차 증대되고 있는 초초임계 순환유동층 보일러에 대한 관심이 증대하고 있다. 초초임계 순환 유동층 보일러는 중소형의 아임계의 드럼형 구조에서 벗어나 대용량화의 기본 구조인 Once Through 형태의 증기 순환 구조를 지니고 100-300 MWe의 상업용 모듈의 복제를 통해 600 MW급이 상용화 운전 중에 있으며, 향후 설계가 완성된 800 MWe의 상업화 진행이 기대되고 있다. 초초임계 순환유동층 보일러는 2017년 이후 아임계 순환유동층 보일러 설치 용량을 추월하여 표준형 모델이 될 것으로 전망되고 있어, 본 논문에서의 이의 기술적 배경과 개발 현황 그리고 시장전망 등을 통해 기술적 이해를 도모하고자 한다.

수직형 순환유동층 열교환기에서의 유체유동과 온도장의 수치해석 (Numerical analysis of fluid flow and thermal fields in the vertical fluidized bed heat exchanger)

  • 이병창;강호근;이명성;안수환
    • 동력기계공학회지
    • /
    • 제16권4호
    • /
    • pp.24-29
    • /
    • 2012
  • The numerical analysis by using CFX 11.0 commercial code was done for prediction of fluid flow and thermal field in the vertical heat exchanger. The present experimental studies were also conducted to investigate the effects of circulating solid particles on the fluid flow and temperatures in the fluidized bed vertical shell and tube type heat exchanger with counterflow, at which the solid particles of glasses (3 $mm{\Phi}$) were used in the fluidized bed with a smooth tube. The effect of circulation on the distance(L) of tube inlet and baffle plate was also examined. The present experimental and numerical results showed that the particles in the distance (Ds) of 15 mm showed a more efficient circulation without stacked the space and the LMTD(Log Mean Temperature Difference) in the fluidized bed type was much lower than that in the typical type shell and tube heat exchanger.

유동층 연소로에서 진동형 공급기의 고체혼합 및 충전물에 대한 압력요동 특성 (The Characteristics of Solid Mixing in a Vibrating Type Feeder and Pressure Fluctuation of Packing Materials for a Fluidized Bed Combustor)

  • 김미영;김의식
    • 한국안전학회지
    • /
    • 제14권3호
    • /
    • pp.101-109
    • /
    • 1999
  • This study attempts to analyse the solid mixing in the feeder and the packing effect for pressure fluctuations in the fluidized bed. To study the mixing characteristics of solid in vibrating feeder for the stable operations of fluidized combustion, the system consisted of two groups of particles such that fine particles were located on the top of the coarse particles before vibratory mixing had started. The effects of packing materials on the pressure fluctuations in a fluidized bed were analysed by using a statistical method to interpret the behavior of fluidized bed. The experiments were carried out in a fluidized bed of 6.7cm-ID, and the experimental variables were particle sizes, of 115 to 1,015$\mu\textrm{m}$ in diameter and the multi-sized particles haying Rosin-Rammler and Gaussian distributions. The settled bed heights of particles to diameter ratios (L/D) were ranged from 0.5 to 2.0. And fluidizing of particles was carried out by air. The packing materials used were screen packing, and the properties of the pressure fluctuations in the fluidized bed were measured by a differential pressure transducer. The properties of the pressure fluctuations calculated were the mean, the standard deviation, and the major frequency of the power spectral density functions. From the characteristics of fluidizing, it was found that the standard deviation of pressure fluctuations could be effectively used to explain the fluidized phenomena, and the packing materials affected severely the properties of the pressure fluctuations. As a result, from the interpretation by spectral analysis, the effects of measuring radius of pressure fluctuations on standard deviation were constant in the case of the fluidized bed with and without packing materials. However, the effects of measuring the height of pressure fluctuations on standard deviations were linear increasing for the fluidized bed with packing materials, but were constant for the fluidized bed without packing materials at 4.5cm above the gas distributor. The major frequency of pressure fluctuations was found to be nearly independent of fluidized system. Also, the major frequency of pressure fluctuations decreased with increasing packing size, and it had maximum value at 10% of the packing amount.

  • PDF

유동층습도계와 아스만습도계의 비교 연구 (Comparative Study of Fluidized Bed-type and Assmann Psychrometer)

  • 강희찬;강민철
    • 설비공학논문집
    • /
    • 제15권9호
    • /
    • pp.779-785
    • /
    • 2003
  • The present work proposed a newly developed fluidized bed-type psychrometer that could be applicable to the high temperature and contaminant gases. The psychrometer is a device that test gas passes through the water in a glass bottle as a bubbly flow to obtain the adiabatic saturation temperature. A fluidized bed-type psychrometer was made and its characteristics were compared with the Assmann Psychrometer. The characteristic time was in the order of a hundred seconds, and decreased for the decrease of the mass of water and the increase of the air flow rate. The air flow rate and the insulation of the glass bottle were definitely important in the accurate measurement of the wet bulb temperature. The error in wet bulb temperature became less than 5 percent of the difference of dry and wet bulb temperatures if the air velocity in the glass bottle was greater than 1.5m/s.

입자층(粒子層)을 이용한 열교환기(熱交換器)에서 소요동력(所要動力)에 따른 전열특성(傳熱特性)에 관(關)한 연구(硏究) (The Heat Transfer Performance with Pumping Power for a Particle Bed Heat Exchanger)

  • 유지오;양한주;조용철;서정윤
    • 설비공학논문집
    • /
    • 제4권4호
    • /
    • pp.351-359
    • /
    • 1992
  • In order to improve the performance of heat exchanger, fluidized bed is often employed. The experiments are carried out in fluidized double pipe parallel flow heat exchanger in which finned tube is vertically immersed. And the heat transfer coefficients between the heated tube and fluidized bed of alumina beads(dp=0.41, 0.54, 0.65, 0.77mm) are calculated as a function of air fluidized velocity and pumping power. The effects of particle size, static bed height and pumping power on the heat transfer coefficients are investigated. And the heat transfer coefficients are compared with that of single phase forced convection heat exchanger. In particular, the heat transfer performance of each type heat exchanger is evaluated in relation to the pumping power.

  • PDF

유동층 반응기에서 하수슬러지의 건조 및 탄화 특성에 관한 연구 (A Study on the Drying and Carbonization of Sewage Sludge in Fluidized Bed Reactor)

  • 정영헌;조기철;강동효;김이광;박창웅;오광중
    • 대한환경공학회지
    • /
    • 제28권7호
    • /
    • pp.746-751
    • /
    • 2006
  • 본 연구에서는 유동층 반응기에서 하수슬러지의 반응온도, 함수율, 입자크기, 가스유속에 따른 건조 및 탄화에 의한 열중량 변화를 관찰하였고 고정층 반응기에서의 결과와 비교하였다. 그 결과, 하수슬러지의 건조시 유동층을 이용한 건조는 고정층의 경우보다 약 6배 건조효율이 증가하였고, 탄화시 유동층을 이용한 경우가 고정층보다 약 4배 빠른 것으로 나타났으며, 슬러지는 약 10분 이내에 유동층 탄화가 완료되는 것으로 판단되었다. 또한, 탄화온도가 증가할수록 탄화물의 양은 감소되나, 873K 이상에서는 탄화물의 양이 유사하였으며, 유속이 증가함에 따라 잔류고형물이 감소하므로 하수슬러지는 873K 유동층 탄화시 유동화 유속범위내에서 저속 유동을 유지하는 것이 효율적인 것으로 판단되었다.

유동층 건조설비에 있어서 분진의 정전기 위험성에 관한 실험적 연구 (Experimental Study on Electrostatic Hazards of Powder in Fluidized Bed)

  • 문균태;정재희;최광석
    • 한국안전학회지
    • /
    • 제25권4호
    • /
    • pp.19-24
    • /
    • 2010
  • A large amount of electrostatic charges is often generated on polymer powders in fluidized bed and thereby may lead to electrostatic problems. In this study, to evaluate electrostatic hazards of powder in fluidized bed, the electric field(E[v/m]) and the charge amount(q[c/g]) during fluidizing were monitored. We also investigated the Minimum Ignition Energy(MIE [J]) of sample powder used in fluidized bed with the Hartman vertical-tube apparatus. The batch-type fluidized bed system and 2kg as Polypropylene(PP) resin powders were used in the experiments. The following results were obtained: (1) Even when a safe margin of several times was considered, the values of E obtained with PP powder in this paper did not exceed 3 to 5kV/cm, at which an incendiary electrostatic discharge could occur. (2) the ave. q was -0.26${\mu}$C/g during fluidizing. This value was high enough to cause electrostatic agglomeration and adhesion. (3) the entrained PP powder in upper column due to fluidizing could be ignited by electrostatic discharges of 71mJ.

파형관을 갖는 수직형 순환유동층 열교환기의 열전달 (Heat Transfer in the Vertical Type Fluidized Bed Heat Exchanger with Corrugated Tubes)

  • 안수환;배성택;김명호;이병창;이윤표
    • 설비공학논문집
    • /
    • 제16권12호
    • /
    • pp.1149-1155
    • /
    • 2004
  • An experimental study was performed to investigate the characteristics of heat transfer in a vertical type fluidized bed shell-and-tube type heat exchanger with corrugated tube. Seven different solid particles having the same volume were circulated in the heat of exchanger. The effects of various parameters such as water flow rates, particle geometries, materials, and corrugated tube geometries were investigated. The present work showed that the higher thermal capacities of materials and the geometries closer to the spherical one have higher heat transfer performances. In addition, heat transfer coefficients in the corrugated tubes were a little higher than those in the smooth tubes.