• Title/Summary/Keyword: fluid flow velocity

Search Result 1,740, Processing Time 0.032 seconds

Numerical Simulation on Drag and Lift Coefficient around Ship Rudder using Computational Fluid Dynamics (전산 유체 역학을 이용한 선박 방향타 주변의 항력 및 양력 계수에 대한 수치 시뮬레이션)

  • Bon-Guk Koo
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.24 no.2
    • /
    • pp.97-102
    • /
    • 2023
  • Numerical simulations have been performed to investigate the hydrodynamic characteristics of the rudder since they play an important role in naval architecture fields. Although some values such as hydrodynamics forces can be measured easily in the towing tanks, it is difficult to obtain the detailed information of the flow fields such as pressure distribution, velocity distribution, vortex generation from experiments. In the present study, the effects of hydrodynamic coefficients and Reynolds number acting on the rudder were studied by using Computational Fluid Dynamics(CFD). Ansys fluent, one of commercial CFD solvers, solves the Navier-Stokes equations and the k-epsilon turbulence model is selected for the viscous model to solve RANS equations. At first, drag coefficients and lift coefficient for different angle of attack are obtained by using a CFD commercial code for KCS rudder. Secondly, the 2-D lift coefficients and drag coefficients are compared with 3-D coefficients at the same conditions. Thirdly, the effects of Reynolds number on the hydrodynamic forces are investigated.

Characteristics and Clinical Outcomes of Cancer Patients who Developed Constrictive Physiology After Pericardiocentesis

  • Hyukjin Park;Hyun Ju Yoon;Nuri Lee;Jong Yoon Kim;Hyung Yoon Kim;Jae Yeong Cho;Kye Hun Kim;Youngkeun Ahn;Myung Ho Jeong;Jeong Gwan Cho
    • Korean Circulation Journal
    • /
    • v.52 no.1
    • /
    • pp.74-83
    • /
    • 2022
  • Background and objectives: This study aimed to identify the characteristics and clinical outcomes of cancer patients who developed constrictive physiology (CP) after percutaneous pericardiocentesis. Methods: One-hundred thirty-three cancer patients who underwent pericardiocentesis were divided into 2 groups according to follow-up echocardiography (CP vs. non-CP). The clinical history, imaging findings, and laboratory results, and overall survival were compared. Results: CP developed in 49 (36.8%) patients after pericardiocentesis. The CP group had a more frequent history of radiation therapy. Pericardial enhancement and malignant masses abutting the pericardium were more frequently observed in the CP group. Fever and ST segment elevation were more frequent in the CP group, with higher C-reactive protein levels (6.6±4.3mg/dL vs. 3.3±2.5mg/dL, p<0.001). Pericardial fluid leukocytes counts were significantly higher, and positive cytology was more frequent in the CP group. In baseline echocardiography before pericardiocentesis, medial e' velocity was significantly higher in the CP group (8.6±2.1cm/s vs. 6.5±2.3cm/s, p<0.001), and respirophasic ventricular septal shift, prominent expiratory hepatic venous flow reversal, pericardial adhesion, and loculated pericardial fluid were also more frequent. The risk of all-cause death was significantly high in the CP group (hazard ratio, 1.53; 95% confidence interval,1.10-2.13; p=0.005). Conclusions: CP frequently develops after pericardiocentesis, and it is associated with poor survival in cancer patients. Several clinical signs, imaging, and laboratory findings suggestive of pericardial inflammation and/or direct malignant pericardial invasion are frequently observed and could be used as predictors of CP development.

Study on the Optimized Condition of the Slot-Die Coating Process (슬롯다이 코팅의 최적화 조건에 관한 연구)

  • Seo, Eung Soo;Ye, Jungwoo;Hwang, Joong Kook;Shim, Jaesool;Chai, Young Suck
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.9
    • /
    • pp.937-945
    • /
    • 2015
  • In this paper, we study the coating performance according to the slot-die conditions in the coating process. The quality of the slot-die coating depends on factors such as feeding speed of film, the viscosity of liquid, and the pressure applied to the slot-die. In this study, we determine the optimum conditions for a stable coating by performing 2-D and 3-D simulations. We carry out numerical simulations with respect to the feeding velocity of the film, the pressure of the slot-die inlet, and the viscosity of the coating liquid. Based on the results, the coating was the most reliable when the pressure of the inlet was $5kgf/cm^2$, the viscosity was about 100 cps and the velocity was 20 m/min.

Visualization and Image Processing for Measurement of Propagational Velocity of Shear Front (유동장의 이동속도측정을 위한 가시화 및 영상처리 방안)

  • Kim Jae-Won;Han Sang-Hoon;Ahn Eun-Young
    • Journal of Korea Multimedia Society
    • /
    • v.8 no.10
    • /
    • pp.1322-1328
    • /
    • 2005
  • The circulation flows passing through the Ekman boundary layer on the rotating disk and transfer the angular momentum into the interior region of the container. Consequently, the circulation enhances the momentum transfer and the interior fluid is divided by a propagating shear front. This investigation focuses on computer vision and image processing technique for analysis of Non-Newtonian Fluids. To visualize marching velocity shear front for the transient flow, a particular shaped particles and light are used. To validate the proposed method, quantitative image are compared with the optical data acquired by a direct measurement of LDV (Laser Doppler Velocimetry).

  • PDF

CFD Study on the Influence of Atmospheric Stability on Near-field Pollutant Dispersion from Rooftop Emissions

  • Jeong, Sang Jin;Kim, A Ra
    • Asian Journal of Atmospheric Environment
    • /
    • v.12 no.1
    • /
    • pp.47-58
    • /
    • 2018
  • The aim of this work is to investigate the effect of atmospheric stability on near-field pollutant dispersion from rooftop emissions of a single cubic building using computational fluid dynamics (CFD). This paper used the shear stress transport (here after SST) k-${\omega}$ model for predicting the flow and pollutant dispersion around an isolated cubic building. CFD simulations were performed with two emission rates and six atmospheric stability conditions. The results of the simulations were compared with the data from wind tunnel experiments and the result of simulations obtained by previous studies in neutral atmospheric condition. The results indicate that the reattachment length on the roof ($X_R$) obtained by computations show good agreement with the experimental results. However, the reattachment length of the rooftop of the building ($X_F$) is greatly overestimated compared to the findings of wind tunnel test. The result also shows that the general distribution of dimensionless concentration given by SST k-${\omega}$ at the side and leeward wall surfaces is similar to that of the experiment. In unstable conditions, the length of the rooftop cavity was decreased. In stable conditions, the horizontal velocity in the lower part around the building was increased and the vertical velocity around the building was decreased. Stratification increased the horizontal cavity length and width near surface and unstable stratification decreased the horizontal cavity length and width near surface. Maintained stability increases the lateral spread of the plume on the leeward surface. The concentration levels close to the ground's surface under stable conditions were higher than under unstable and neutral conditions.

Evaluation of LDF Signal Processing Algorithms Using Self-mixing Effect of Laser Diode (LD의 자기혼합 효과를 이용한 LDF의 신호처리 알고리즘의 평가)

  • Go, Han-U;Kim, Jong-Won
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.4
    • /
    • pp.369-377
    • /
    • 1998
  • This paper describes the results of investigations comparing the relative in vitro responses of different signal processing algorithms for laser Doppler flowmetry(LDF) using self-mixing effect of laser diode(LD). A versatile laser Doppler system is described which enabled complex signal processing to be implemented relatively simply using digital analysis. The flexibility of the system allowed a variety of processing algorithms to be studied by simply characterising the algorithm of interest under software control using a personal computer. Two in-vitro physical models are also presented which was used to maintain reproducible fluid flows Flows of particles were studied in two physical models using a 780nm laser diode source. The results show that frequency weighted algorithms(first and second moments, rate to zero moment) are responsive to particle velocity more than concentration, whereas non-weighted algorithm (zero moment responds to concentration and velocity.

  • PDF

Numerical Study on Propeller Cavitation and Pressure Fluctuation of Model and Full Scale ship for a MR Tanker (MR Tanker 실선 및 모형선 프로펠러 캐비테이션 및 변동압력 수치해석 연구)

  • Park, Il-Ryong;Kim, Ki-Sup;Kim, Je-In;Seol, Han-shin;Park, Young-Ha;Ahn, Jong-Woo
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.57 no.1
    • /
    • pp.35-44
    • /
    • 2020
  • Propeller cavitation extent, pressure fluctuation induced by cavitation, pressure distribution on propeller blade, total velocity distribution and nominal wake distribution for a MR Taker were computed in both conditions of model test and sea trial using a code STAR-CCM+. Then some of the results were compared with model test data at LCT and full-scale measurement (Ahn et al (2014); Kim et al (2014)] in order to confirm the availability of a numerical prediction method and to get the physical insight of local flow around a ship and propeller. The nominal wake distributions computed and measured by LDV velocimeter on the variation of on-coming velocity show the wake contraction characteristics proposed by Hoekstra (1974). The numerical prediction of propeller cavitation extent on a blade angular position and pressure fluctuation level on each location of pressure sensors are very similar with the experimental results.

Optimal Fuzzy Sliding-Mode Control for Microcontroller-based Microfluidic Manipulation in Biochip System

  • Chung, Yung-Chiang;Wen, Bor-Jiunn
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.196-201
    • /
    • 2004
  • In biometric and biomedical applications, a special transporting mechanism must be designed for the ${\mu}$TAS (micro total analysis system) to move samples and reagents through the microchannels that connect the unit procedure components in the system. An important issue for this miniaturization and integration is microfluid management technique, i.e., microfluid transportation, metering, and mixing. In view of this, this study presents an optimal fuzzy sliding-mode control (OFSMC) design based on the 8051 microprocessor and implementation of a complete microfluidic manipulated system implementation of biochip system with a pneumatic pumping actuator, a feedback-signal photodiodes and flowmeter. The new microfluid management technique successfully improved the efficiency of molecular biology reaction by increasing the velocity of the target nucleic acid molecules, which increases the effective collision into the probe molecules as the target molecules flow back and forth. Therefore, this hybridization chip was able to increase hybridization signal 6-fold and reduce non-specific target-probe binding and background noises within 30 minutes, as compared to conventional hybridization methods, which may take from 4 hours to overnight. In addition, the new technique was also used in DNA extraction. When serum existed in the fluid, the extraction efficiency of immobilized beads with solution flowing back and forth was 88-fold higher than that of free-beads.

  • PDF

Analysis of Two-Dimensional Sloshing Problems by a Lagrangian FEM (Lagrangian 유한요소법을 이용한 2차원 탱크내 유동해석)

  • P.M.,Lee;S.W.,Hong;S.Y.,Hong
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.27 no.2
    • /
    • pp.21-30
    • /
    • 1990
  • Theoretical and experimental techniques to analyze the two-dimensional liquid motion in a tank are discussed. A Lagrangian FEM with a velocity correction procedure is introduced to describe incompressible free surface fluid flow. A mesh rezoning technique is used to prevent strong distortion of finite elements in the Lagrangian description. Model test technique for sloshing tank is developed using a hydraulic type bench tester. The influence of the variation in the exciting frequency and amplitude are observed for various fill depths. The results of theoretical calculations are compared with those of experiments.

  • PDF

Analysis of a Cryogenic Nitrogen-Ambient Air Heat Exchanger Including Frost Formation (착상을 고려한 극저온 질소-대기 열교환기의 해석)

  • 최권일;장호명
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.9
    • /
    • pp.825-834
    • /
    • 2000
  • A heat exchanger analysis is performed to investigate the heating characteristics of cryogenic nitrogen by ambient air for the purpose of cryogenic automotive propulsion. The heat exchanger is a concentric triple-passage for supercritical nitrogen, and the radial fins are attached on the outermost tube for the crossflow of ambient air. The temperature distribution is calculated for the nitrogen along the passage, including the real gas properties of nitrogen, the fluid convections and the conductions through the tube walls and the fins. Since the wall temperature of the outer (ambient side) tube is very low in most cases, a heavy frost can be formed on the surface, affecting the heat exchange performance. By the method of the similarity between the heat and the mass transfer of moist air, the frost growth and the time-dependent effectiveness of the heat exchanger are calculated for various operating conditions. It is concluded that the frost formation can augment the heating of nitrogen during the initial period because of the latent heat, then gradually degrades the heat exchange because of the increased thermal resistance. Practical design issues are discussed for the flow rate of nitrogen, the velocity and humidity of ambient air, and the sizes of the fin.

  • PDF