• 제목/요약/키워드: fluid balance

검색결과 278건 처리시간 0.024초

Numerical hydrodynamic analysis of an offshore stationary-floating oscillating water column-wave energy converter using CFD

  • Elhanafi, Ahmed;Fleming, Alan;Macfarlane, Gregor;Leong, Zhi
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제9권1호
    • /
    • pp.77-99
    • /
    • 2017
  • Offshore oscillating water columns (OWC) represent one of the most promising forms of wave energy converters. The hydrodynamic performance of such converters heavily depends on their interactions with ocean waves; therefore, understanding these interactions is essential. In this paper, a fully nonlinear 2D computational fluid dynamics (CFD) model based on RANS equations and VOF surface capturing scheme is implemented to carry out wave energy balance analyses for an offshore OWC. The numerical model is well validated against published physical measurements including; chamber differential air pressure, chamber water level oscillation and vertical velocity, overall wave energy extraction efficiency, reflected and transmitted waves, velocity and vorticity fields (PIV measurements). Following the successful validation work, an extensive campaign of numerical tests is performed to quantify the relevance of three design parameters, namely incoming wavelength, wave height and turbine damping to the device hydrodynamic performance and wave energy conversion process. All of the three investigated parameters show important effects on the wave-pneumatic energy conversion chain. In addition, the flow field around the chamber's front wall indicates areas of energy losses by stronger vortices generation than the rear wall.

경막외 신경차단술 시행 중 발생한 감각신경성난청과 어지럼 1예 (A Case of Sensorineural Hearing Loss and Vertigo during Epidural Nerve Block)

  • 이병민;노진홍;안성기;박현우
    • Research in Vestibular Science
    • /
    • 제17권4호
    • /
    • pp.170-174
    • /
    • 2018
  • Epidural anesthesia has significantly advanced in neuraxial anesthesia and analgesia. It is used for surgical anaesthesia and treatment of chronic pain. Hearing loss during or after epidural anesthesia is rare, and it is known to occur by the change of the intracranial pressure. Cerebrospinal fluid is connected with perilymph in the cochlear and vestibule that is important to hearing and balance. If the intracranial pressure is abruptly transferred to the inner ear, perilymph can be leak, that called perilymphatic fistula, dizziness, and hearing loss can occur suddenly. We report a 65-year-old woman who presented with acute onset dizziness and hearing loss during the epidural nerve block for back pain, wherein we speculated a possibility of perilymphatic fistula as the mechanism of hearing loss and dizziness. The mechanism of dizziness and hearing loss was suspected with perilymphatic fistula.

2015 한국 성인의 수분 섭취기준 설정 (Establishment of reference intake of water for Korean adults in 2015)

  • 이재현;김선효
    • Journal of Nutrition and Health
    • /
    • 제50권2호
    • /
    • pp.121-132
    • /
    • 2017
  • Purpose: This review was performed to establish a reference intake of water for Korean (KDRI-water) adults in 2015 by examining current knowledge of the relationship between water intake and health and the general status of water intake and loss. We expect that this study will be utilized for further refinement of KDRI-water. Methods: Documents were searched using RISS, NDSL, DBPIA, CINAHL, and Pubmed with the keywords 'water intake, water supply, water ingestion, hydration, dehydration, water balance, and fluid balance'. Results: Water balance is essential for the maintenance of health. Based on this assumption, numerous studies have been performed to investigate the association of water intake with several diseases such as urolithasis, obesity, diabetes, and cancer as well as other health problems, including constipation, cognition, and fetal weight. Effects of water intake for prevention or relief of these health problems vary. Water is supplied to the body by eating foods and drinking liquids such as plain water and beverages. Metabolic water is another source of water input. Water is lost through urine, skin, respiration, and feces. KDRI-water 2015 was set by adequate intake (AI) based on water intake volume, which was the sum of water intakes from foods and fluids reported by the Korea National Health and Nutrition Examination Survey, with extra milk intake of 200 mL. AIs in some age groups were modified considering their estimated energy requirements. Conclusion: Accurate data of water intake is critically important for the establishment of KDRI-water. Therefore, improvement of systems investigating water intake is required, and more studies on the status of water intake and loss in Korean people are needed for definite KDRI-water establishment.

Effects of Alcohol Intake on Body Fluid Balance and Fat Mobilization After Exercise Induced Dehydration

  • Park, Hyun-Jeong;Bae, Yoon-Jung;Lee, Joo-Hyung;Lee, Dae-Taek
    • Nutritional Sciences
    • /
    • 제9권2호
    • /
    • pp.124-130
    • /
    • 2006
  • To examine the effects of alcohol consumption on body fluid restoration and fat mobilization following exercise induced dehydration, nine healthy collegiate men ($24{\pm}2yrs,\;177{\pm}5cm,\;72{\pm}8kg,\;10.5{\pm}2.3%$ body fat) underwent three experiments. In each experiment, subjects ran on a treadmill to reduce individual body mass to $2.2{\pm}0.1%$ and consumed one of three beverages containing 0, 4, or 8% alcohol over 60 min followed by 4 hr of resting recovery. They consumed approximately 150% of weight loss $(2053{\pm}204,\;2091{\pm}149,\;and\;1943{\pm}295mL)$ and content of alcohol was $9.9{\pm}1.0(0%),\;71.9{\pm}5.1(4%)$, and $132.2{\pm}20.1g$ (8% trial). Body weight, urine volume and samples, blood samples, and thirst sensation were measured five times; at baseline, immediately after exercise, and 0, 1st, and 4th hr of recovery. Blood alcohol concentration after ingestion was $0.0{\pm}0.0(0%),\;0.1{\pm}0.02(4%)$, and $0.2{\pm}0.03%$ (8% trial). No differences in blood sodium and potassium concentrations, and urine specific gravity were noticed over time periods and trials. Thirst sensation tended to be elevated in all trials immediately after exercises and urine output was elevated during the recovery. The magnitude of changes in these variables was proportional to the alcohol concentrations, but not statistically significant. While serum osmolality was not different among trials and time periods in 0 and 4% trials, it was higher during recovery than the baseline in the 8% trial (P<0.01). Triglycerides did not change throughout the time period and among trials. Free fatty acids were elevated after exercise in all trials and 4th hr of recovery in 0% (P<0.05). Subjects' net body fluid balance at 4th hr of recovery was negatively maintained and proportional to alcohol concentrations. Only 8% trials showed a significant reduction at 1st and 4th hr of recovery compared to 0 hr. The results suggested that diuretic effect of alcohol after moderate level of dehydration appeared dose dependent, but beverage containing alcohol up to 4% did not induce impaired rehydration than alcohol free drinks. Alcohol effects on fat mobilization during recovery appeared to be minimal and the mechanism is unclear.

압축 유동하에 있는 시멘트 페이스트의 유변학적 거동에 관한 모델링 (Modeling on Rheological Behavior of Cement Paste under Squeeze Flow)

  • 민병현
    • 한국산학기술학회논문지
    • /
    • 제21권9호
    • /
    • pp.405-413
    • /
    • 2020
  • 압축 유동하에서 측정된 시멘트 페이스트의 수직 응력은 변형률의 증가에 따라 변형률이 0.0003에서 0.003 사이 구간인 탄성 고체 구간과 변형률이 0.003에서 0.8 사이 구간인 변형률 경화 구간으로 나누어진다. 두 구간 중 변형률 경화 영역에서 유변학적 특성을 분석하기 위해 모델링 식이 제안되었다. 첫째, 유체 거동의 관점에서, 지수법칙 일관성 지수 m=700 및 멱지수 n=0.2를 갖는 지수법칙 비뉴토니언 모델이 적용되었다. 적용 결과는 탄성 고체 구간을 제외하고는 실험 결과와 좋은 일치를 보여주었다. 둘째, 연성 고체 거동의 관점에서 힘 평형 모델이 적용되었으며, 하중을 측정하는 센서부와 시멘트 페이스트 표면 간의 마찰 계수가 실험데이터에 반구간탐색법을 적용하여 변형률의 다항식으로 도출되었다. 적용 결과는 변형률이 0.003에서 0.3 사이 구간인 중간 영역에서만 실험 결과와 좋은 일치를 보여주었다. 따라서, 압축 유동 하의 시멘트 페이스트의 유변학적 거동은 변형률 경화 구간에서 연성 고체 거동의 관점보다는 지수법칙 비뉴토니언 유체 거동의 관점에서 실험 결과와 더 일치함을 보여주었다.

하나로 2차 냉각펌프의 고진동 해소방안 (The Solution of Severe Vibration Problen of the Secondary Cooling Pump in HANARO)

  • 박용철
    • 한국유체기계학회 논문집
    • /
    • 제5권4호
    • /
    • pp.26-31
    • /
    • 2002
  • The heat produced by the fission in the fuel of HANARO, 30 MW of research reactor, was transferred from the primary cooling water to the secondary cooling water through heat exchangers. The secondary cooling water absorbing the heat was circulated by secondary cooling pumps and cooled through 33 MW of cooling tower. Each capacity of the three secondary cooling pumps was fifty percent ($50\%$) of full load. The two pumps were normally operated and the other pump was standby. One of the secondary cooling pumps has often made troubles by high vibration. To release these troubles the pump shaft has been re-aligned, the pump bearing has been replaced with new one, the shaft sleeve has been replaced with new one, the shaft and the impeller have been re-balanced representatively and/or the vibration of motor has been tested by disconnecting the shaft of pump. But the high vibration of pump cannot be cleared. We find out the weight balance trouble of the assembly in which the impeller is installed in the shaft. After clearing the trouble, the high vibration is relieved and the pump is operated smoothly. In this paper, the trouble solution shooting method of secondary cooling pump is described including the reason of high vibration

Simulation of Cardiovascular System for an Optimal Sodium Profiling in Hemodialysis

  • Lim, K.M.;Min, B.G.;Shim, E.B.
    • International Journal of Vascular Biomedical Engineering
    • /
    • 제2권2호
    • /
    • pp.16-26
    • /
    • 2004
  • The object of this study is to develop a mathematical model of the hemodialysis system including the mechanism of solute kinetics, water exchange and also cardiovascular dynamics. The cardiovascular system model used in this study simulates the short-term transient and steady-state hemodynamic responses such as hypotension and disequilibrium syndrome (which are main complications to hemodialysis patients) during hemodialysis. It consists of a 12 lumped-parameter representation of the cardiovascular circulation connected to set-point models of the arterial baroreflexes, a kinetic model (hemodialysis system model) with 3 compartmental body fluids and 2 compartmental solutes. We formulate mathematically this model in terms of an electric analog model. All resistors and most capacitors are assumed to be linear. The control mechanisms are mediated by the information detected from arterial pressoreceptors, and they work on systemic arterial resistance, heart rate, and systemic venous unstressed volume. The hemodialysis model includes the dynamics of urea, creatinine, sodium and potassium in the intracellular and extracellular pools as well as fluid balance equations for the intracellular, interstitial, and plasma volumes. Model parameters are largely based on literature values. We have presented the results on the simulations performed by changing some model parameters with respect to their basal values. In each case, the percentage changes of each compartmental pressure, heart rate (HR), total systemic resistance (TSR), ventricular compliance, zero pressure filling volume and solute concentration profiles are represented during hemodialysis.

  • PDF

추적자를 이용한 유량 측정 (Measurement of Water Flow in Closed Conduits by Chemical Tracer Method)

  • 이선기;정백순;김창호
    • 한국유체기계학회 논문집
    • /
    • 제2권2호
    • /
    • pp.19-26
    • /
    • 1999
  • Thermal output in a nuclear power plant is verified with calorimetric heat balance on the secondary plant. The calorimetry involves the precise measurement of the feedwater flow rate. However, the correct indication of feedwater flow rate obtained by a pressure-difference measurement across a venturi can be affected by instrument errors, fouling or a poorly developed velocity profile. This can result in an inaccurate mass flow rate and consequently an inaccurate estimate of power. The purpose of this study is to develop verification methods with accuracy better than $0.5\%$ for high precision flow measurement to be used for measuring feedwater flow rate. This chemical tracer method is a testing process that uses tracers which can be applied to quantify losses in electrical output due to the incorrect measurements of feedwater flow rate. And this system has good response to the variation of the flow rate. Accuracy of better than 0.5 percent can be expected for feedwater flow measurement, providing that the system can be stabilized during the test. This methodology is applicable to other flow systems well.

  • PDF

CFD prediction and simulation of a pumpjet propulsor

  • Lu, Lin;Pan, Guang;Sahoo, Prasanta K.
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제8권1호
    • /
    • pp.110-116
    • /
    • 2016
  • In this study an attempt has been made to study the hydrodynamic performance of pumpjet propulsor. Numerical investigation based on the Reynolds Averaged NaviereStokes (RANS) computational fluid dynamics (CFD) method has been carried out. The structured grid and SST ${\kappa}-{\omega}$ turbulence model have been applied. The numerical simulations of open water performance of marine propeller E779A are carried out with different advance ratios to verify the numerical simulation method. Results show that the thrust and the torque are in good agreements with experimental data. The grid independent inspection is applied to verify accuracy of numerical simulation grid. The numerical predictions of hydrodynamic performance of pumpjet propulsor are carried out with different advance ratios. Results indicate that the rotor provides the main thrust of propulsor and the balance performance of propulsor is generally satisfactory. Additionally, the curve of propulsor efficiency is in good agreement with experimental data. Furthermore, the pressure distributions around rotor and stator blades are reasonable. Beyond that, the existence of tip clearance accounts for the appearance of tip vortex that leads to a further loss in efficiency and a probability of cavitation phenomenon.

고분자 전해질 연료 전지용 공기공급계의 동특성 및 성능에 대한 연구 (Study on Dynamic Characteristic & Performance of the Air Supply System for PEM Fuel Cell)

  • 이희섭;김창호;이용복
    • 한국유체기계학회 논문집
    • /
    • 제9권6호
    • /
    • pp.45-53
    • /
    • 2006
  • Turbo-blower as an air supply system is one of the most important BOP (Balance of Plant) systems for FCV(Fuel Cell Vehicle). For generating and blowing compressed air, the motor of air blower consumes maximum 25% of net power, and fuel cell demands a clean air. In this study, turbo-blower supported by air foil bearings is introduced as the air supply system used by 80kW proton exchange membrane fuel systems. The turbo-blower is a turbo machine which operates at high speed, so air foil bearings suit their purpose as bearing elements. Analysis for confirming the stability and endurance is conducted. The rotordynamic stability was predicted using the numerical analysis of air foil bearings and it is verified through experimental works. In spite of various transient dynamic situation, the turbo-blower had stable performances. After the performance test, results are presented. The normal power of driving motor has about 1.6 kW with the 30,000 rpm operating range and the flow rate of air has maximum 160 SCFM. The test results show that the aerodymic performance and stability of turbo-blower are satisfied to the primary goals.