• Title/Summary/Keyword: fluid and flow

Search Result 7,251, Processing Time 0.039 seconds

Coupled Analysis of the Fluid Dynamic Bearings with the Recirculation Channel by Solving the Reynolds and Hagen-Poiseuille Equations (Reynolds 방정식과 Hagen-Poiseuille 방정식의 연성해석을 통한 재순환홀을 갖는 유체동압베어링의 해석)

  • Kang, Chiho;Jang, Gunhee;Jung, Yeonha
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.760-767
    • /
    • 2014
  • This paper proposes a method to calculate pressure and flow of the fluid dynamic bearings (FDBs) with a recirculation channel (RC) by solving the Reynolds and the Hagen-Poiseuille equations at the same time. The Hagen-Poiseuille equation is one-dimensional equation which describes the flow in a circular pipe such as the RC. This research developed a finite element program to solve the Reynolds and the Hagen-Poiseuille equation together. The proposed method was applied to calculate the pressure and flow of the FDBs which are composed of grooved or plain journal and thrust bearings, and RC. To verify the proposed method, it also developed a finite volume model of the FDBs, and pressure and flow were calculated by the commercial CFD solver. They agree well with the pressure and flow calculated by the proposed method. Finally, this research investigated the characteristics of the FDBs due to the radius change of the RC.

  • PDF

Analysis on the Flow and the Byproduct Particle Trajectory of Roots Type Vacuum Pump (루츠식 진공 펌프의 유동 및 부산물 입자 궤적에 대한 해석)

  • Lee, Chan;Kil, Hyun-Gwon;Noh, Myung-Keun
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.5
    • /
    • pp.18-23
    • /
    • 2011
  • A CFD analysis method is developed and applied for investigating the gas flow and the byproduct particle trajectory in Roots type vacuum pump. The internal fluid flow and thermal fields between the rotors and the housing of vacuum pump are analyzed by using the dynamic mesh, the numerical methods for unsteady 2-D Navier-Stokes equation and the standard k-$\varepsilon$ turbulence model of the Fluent code. Coupled with the flow simulation results, the particle trajectory of the byproduct flowing into the pump with gas stream is analyzed by using discrete phase modeling technique. The CFD analysis results show the pressure, the velocity and the temperature distributions in pump change abruptly due to the rotation of rotors, and back flows are produced due to the strong reverse pressure gradients at rotor/rotor and rotor/housing clearances. The predicted byproduct particle trajectory results also show the particles impinge on the clearance surfaces between the housing and the rotor of pump and then may form the deposit layer causing the failure of pump.

PIV Measurement of Inlet and Outlet Flow of Contra-Rotating Small-Sized Cooling Fan

  • Shigemitsu, Toru;Fukuda, Hiroaki;Fukutomi, Junichiro
    • International Journal of Fluid Machinery and Systems
    • /
    • v.9 no.2
    • /
    • pp.175-181
    • /
    • 2016
  • Contra-rotating rotors have been adopted for some of the cooling fans to meet the demand for the high pressure and large flow rate. Therefore, it is important to clarify its inlet and outlet flows by experiments for the high performance and stable operation. PIV measurements were conducted at the design and partial flow rates. In the present paper, the inlet and outlet flow conditions of the contra-rotating small-sized cooling fan with a 40mm square casing are studied by using PIV measurement. Furthermore, improvements of the flow condition and design guideline to increase the performance were discussed based on the experimental results.

Axial Wall Slits Effect on the Helical Flow in the Gap between two Concentric Cylinders

  • Liu, Dong;Yang, Xiao-Yong;Ding, Jian;Kim, Hyoung-Bum
    • International Journal of Fluid Machinery and Systems
    • /
    • v.5 no.2
    • /
    • pp.60-64
    • /
    • 2012
  • The helical flow regime was investigated by using DPIV when the rotating Reynolds number is small. The wall slits were azimuthally located along the inner wall of outer cylinder and the slits number of each model was 9 and 18, another plain wall model was also studied for comparison purpose. The helical vortex flow regime can be observed in all the three models. The negative temperature gradients determine the direction of the rotation and movement of the helical vortex. But the helical wavy vortex flow can only be found in the plane and 9-slit models. And the result showed that the existence of slit wall accelerated the transition process.

Characterization of Interaction between Two Particles/Bubbles Flow with Moving Object Flow Image Analyzer System (MOFIA에 의한 두개 입자/기포간 상호작용에 관한 연구)

  • Choi Hae Man;Monji Hideaki;Matsui Goichi
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.2
    • /
    • pp.110-116
    • /
    • 2005
  • This paper deals with interaction between two bubbles or particles and flow around them, visualized by a moving object flow image analyzer(MOFIA) consisting of a three-dimensional (3D) moving object image analyzer(MOIA) and two-dimensional particle image velocimetry(PIV). The experiments were carried out for rising bubbles or particles of various densities, sizes, and/or shapes in stagnant water in a vertical pipe. In the MOFIA employed, 3D-MOIA was used to measure particles or bubbles motion and PIV was used to measure fluid flow, The experimental results showed that the interaction was characterized by the shape, size and density of two particles or bubbles.

A Computerized Design System of the Axial Fan Considering Performance and Noise Characteristics (성능 및 소음특성을 고려한 축류 팬 설계의 전산 체계)

  • Lee, Chan;Kil, Hyun-Gwon
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.2
    • /
    • pp.48-53
    • /
    • 2010
  • A computerized design system of axial fan is developed for constructing 3-D blade geometry and predicting both aerodynamic performance and noise. The aerodynamic blading design of fan is conducted by blade angle distribution, camber line determination, airfoil thickness distribution and blade element stacking along spanwise distance. The internal flow and the aerodynamic performance of designed fan are predicted by the through-flow modeling technique with flow deviation and pressure loss correlations. Based on the predicted internal flow field and performance data, fan noise is predicted by two models for discrete frequency and broadband noise sources. The present predictions of the flow distribution, the performance and the noise level of actual fans are well agreed with measurement results.

Measurement Techniques on Unsteady Flow at Impeller Exit (임펠러 출구에서의 비정상 유동 측정 기법)

  • Shin, You-Hwan;Kim, Kwang-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.2 no.1 s.2
    • /
    • pp.81-87
    • /
    • 1999
  • This study presents the measurement techniques on the periodic fluctuating flow such as the discharge flow of a centrifugal impeller in an unstable operating region. During rotating stall, the flow at the exit of a centrifugal compressor impeller fluctuates periodically with a lower frequency than that of the blade passing. To observe the blade-to-blade flow characteristics during the rotating stall, the phases of all the sampled data sets should be adjusted to those of the reference signals with two processes, in these processes, DPLEAT (Double Phase-Locked Ensemble Averaging Technique) can be used. From these measurements and data processing techniques, the characteristics illustrated a blade-to-blade flow with high frequency, but also a periodic rotating stall flow with a low frequency at the centrifugal impeller exit which was clearly observed.

  • PDF

A comparing on the use of Centrifugal Turbine and Tesla Turbine in an application of Organic Rankine Cycle

  • Thawichsri, Kosart;nilnont, Wanich
    • International Journal of Advanced Culture Technology
    • /
    • v.3 no.2
    • /
    • pp.58-66
    • /
    • 2015
  • This paper aims to compare the use of Centrifugal Turbine and Tesla Turbine in an application of Organic Rankine Cycle (ORC) Machine using Isopentane as working fluid expanding. The working fluid has boiling point below boiling water and works in low-temperature sources between $80-120^{\circ}C$ which can be produced from waste heat, solar-thermal energy and geothermal energy etc. The experiment on ORC machine reveals that the suitability of high pressure pump for working fluid has result on the efficiency of work. In addition, Thermodynamics theory on P-h diagram also presented the effect of heat sources' temperature and flow rate on any work. Thus, the study and design on ORC machine has to concern mainly on pressure pump, flow rate and optimized temperature. Result experiment and calculate ORC Machine using centrifugal Turbine efficiency better than Tesla turbine 30% but Tesla Turbine is cheaper and easily structure. Further study on the machine can be developed throughout the county due to its low cost and efficiency.

PREPARATION OF NICKEL POWDERS BY REDUCTION OF NICKEL HYDROXIDE USING THE TAYLOR FLUID FLOW

  • I.-J. PARK;D.-W. KIM;G.-H. KIM;H.-J. CHAE;H.-C. JUNG
    • Archives of Metallurgy and Materials
    • /
    • v.63 no.3
    • /
    • pp.1443-1447
    • /
    • 2018
  • In this study, Ni(OH)2 was synthesized by the continuous reaction by the Taylor fluid flow and compared with those prepared from the conventional batch type reaction. The nickel powders were synthesized by reduction of Ni(OH)2 in an aqueous solution with hydrazine hydrate acting as the reductant. And then the characteristics of the nickel powder according to the synthesis method were compared. The average particle size of the synthesized Ni(OH)2 using Taylor reactor was generally decreased about 1.5~2.5 times more than the batch reaction. The nickel powders prepared by the batch reaction highly agglomerated with non-uniform particles. In the Taylor reaction, the agglomeration of particles was broken and uniform nickel powder was produced.

Flow Characteristics of Polluted Air in a Rectangular Tunnel using PIV and CFD

  • Lee, Yong-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.5
    • /
    • pp.609-617
    • /
    • 2012
  • The flow characteristics of polluted air are analysed by comparing the results obtained from PIV(Particle Image Velocimetry) experiment and CFD(Computational Fluid Dynamics) commercial code. In order to simulate the polluted air flow, the olive oil has been used as tracer particles with the kinematic viscosity of air, $1.51{\times}10^{-5}m^2/s$. The investigation has done in the range of Reynolds numbers of 870, 1730 and 2890 due to the inlet flow velocities of 0.3, 0.6, and 1.0 m/s, respectively. The average velocity and the pressure distributions are comparatively discussed with respect to the three different Reynolds numbers. The results show that the outlet flow rates at three different Reynolds numbers are equivalent of 165 to 167 percent of the inlet ones. The pressure drop occurs in the model closed at both end sides and the highest pressures at each Reynolds number are positioned at the top of the tunnel between the inlet and outlet.