• Title/Summary/Keyword: fluid and flow

Search Result 7,252, Processing Time 0.033 seconds

Prediction of Worker's Exposure in a Uniform Freestream (균일류 하에서 작업하는 근로자의 노출농도 예측)

  • Jung, Yu-Jin;Kim, Hwan-Tae;Ha, Hyun-Chul;Kim, Tae-Hyeung
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.10 no.2
    • /
    • pp.140-149
    • /
    • 2000
  • In industrial field, there are several operations where a horizontal unidirectional airflow is used to control airborne contaminants. When a worker is immersed in a uniform freestream, a recirculating airflow can be created downstream of the worker by the phenomenon of boundary layer seperation. If the contaminant source and the breathing zone are within this near-wake region, high exposure may occur. The investigation for the effect of contaminant source location on worker exposure was performed by using CFD(Computational Fluid Dynamics). The airflow field was numerically calculated by assuming a steady flow and using the standard $k-{\varepsilon}$ turbulence model. As the results were compared with experimental data, the applicability of CFD was successfully verified. Subsequently, the breathing zone concentrations of the worker were predicted and compared with experimental data. The effects of contaminant density and turbulence intensity of freestream on worker exposure were evaluated.

  • PDF

Waterhammer for the Intake Pumping Station with the Pump Control Valve (펌프제어밸브를 사용한 취수펌프장에서의 수격현상)

  • Kim, Kyung-Yup;Oh, Sang-Hyun
    • The KSFM Journal of Fluid Machinery
    • /
    • v.4 no.4 s.13
    • /
    • pp.16-21
    • /
    • 2001
  • The field tests on the waterhammer were carried out for PalDang intake pumping station of the metropolitan water supply 5th stage project. The pumping station was equipped with the pump control valve as the main surge suppression device and the surge relief valve as auxiliary. However, the pump control valve had not been early controlled in the planned closing mode, and the slamming occurred to the valve which abruptly closed during the large reverse flow. Because the pressure wave caused by the pump failure was superposed on the slam surge, the upsurge increased so extremely that the shaft of the valve was damaged. It was desirable that the surge relief valve was installed in the pumping station or near the pump exit for the delay of response. After reforming the oil dashpot of the pump control valve, the sliming disappeared and the measured pressure was in fairly good agreement with the results of simulation. In case of three pumps for ${\phi}2,600$ pipeline being simultaneously tripped, the pressure head in the pumping station increased to 95.6 m, and the upsurge caused by the emergency stop of four pumps for ${\phi}2,800$ pipeline was 89.6m. We concluded that the pumping station acquired the safety and reliability for the pressure surge.

  • PDF

Development of Pump/Motor Selection Program for Optimized Pump Decision of the Regional Water Supply Facilities (광역상수도용 펌프의 최적결정을 위한 펌프/모터 선정 프로그램 개발)

  • Roh, Hyung-Woon;Kim, Jae-Soo;Park, Gil-Moon;Suh, Sang-Ho;Lee, Young-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.4 no.4 s.13
    • /
    • pp.22-27
    • /
    • 2001
  • The pump/motor selection program for optimized selection of regional water supply facilities was developed based on a flowchart compiled from basic operational data, total head requirement, initial pump/motor specification selection etc. This program was developed in Visual Basic. The program accepts, as in the flowchart, operational requirements of pumps and other system requirements, and calculates specific speed based on flow rate, total head and rotational speed. Then the calculated specific speed is used to select pump types and speed prior to determining likelihood of cavitation occurring at the calculated NPSH. Power requirement is then calculated for safe operation of pump to assist final pump selection. Test results of the program match very closely to the design values of Paldang intake pump station(3rd stage) proving that the program can be used as an effective and practical aid for designing new regional water supply systems.

  • PDF

Improvement for Response Delays of Displacement Magnifier in Jetting Dispenser (젯팅 디스펜서 변위확대장치의 응답지연 개선 연구)

  • Ha, Myeong-Woo;Lee, Kwang-Hee;Hong, Seung-Min;Lee, Chul-Hee
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.5
    • /
    • pp.546-551
    • /
    • 2016
  • The objective of this study is to investigate the response delays between piezo-stack actuator and the displacement magnifier of jetting dispenser and to reduce its falling time in terms of displacement optimization. The dispenser is driven by the dual piezo-stack actuators with a hinge lever mechanism to precisely control flow rate of the working fluid (3000 cP). It is commonly found that piezo actuator-driven jetting dispensers involving viscous working fluids have displacement optimization problem for ideal performance. The response delay of the system is caused by the phenomenon that the displacement magnifier cannot exactly follow the motion of the piezo actuators. The response delay may lower the performance of the system due to the inaccurate discharge of working fluid or even damages to the system itself due to inharmonious motion of piezo actuators with lever system. To reduce its response delay, a new displacement profile obtained from displacement optimization is suggested; its performance is tested through finite element analysis; and experiments are carried out to verify the performance of the obtained displacement profile.

Characterization of Dynamic Behavior of C. elegans in Different Physical Environments (PIV 및 TFM 측정 기법을 이용한 예쁜꼬마선충의 동적 패턴 가시화 연구)

  • Park, Jin-Sung;Yun, Byoung Hwan;Shin, Jennifer H.
    • Journal of the Korean Society of Visualization
    • /
    • v.12 no.2
    • /
    • pp.18-22
    • /
    • 2014
  • Caenorhabditis elegans (C. elegans) is an undulatory nematode which exhibits two distinct locomotion types of swimming and crawling. Although in its natural habitat C. elegans lives in a non-Newtonian fluidic environment, our current understanding has been limited to the behavior of C. elegans in a simple Newtonian fluid. Here, we present some experimental results on the penetrating behavior of C. elegans at the interface from liquid to solid environment. Once C. elegans, which otherwise swims freely in a liquid, makes a contact to the solid gel boundary, it begins to penetrate vertically to the surface by changing its stroke motion characterized by a stiffer body shape and a slow stroke frequency. The particle image velocimetry (PIV) analysis reveals the flow streamlines produced by the stroke of worm. For the worm that crawls on a solid surface, we utilize a technique of traction force microscopy (TFM) to find that the crawling nematode forms localized force islands along the body where makes direct contacts to the gel surface.

A Study on the Auto Fuel Feeding Control System using Hall Sensor (홀 센서를 이용한 자동연료공급 제어장치에 관한 연구)

  • Kim, Gyu-Sung;Cho, Myung-Hyun
    • 전자공학회논문지 IE
    • /
    • v.43 no.3
    • /
    • pp.34-40
    • /
    • 2006
  • Usually, fluid or fuel supply device need space to need special sensor to control motor, attaches with ancillary equipment to attach sensor. Also, difficult point follows need signal line and other circuit etc. In this paper, used that proposed control system that use hall sensor to solve discomfort and problem and difference control principle of system happens in current flow according to motor action step. Also, could reduce breakdown by sensor establishment, reduce material costs and personnel expenses as well as control system superior. Auto-pumping system sees that will can apply, develop several kind of device that use system hereafter to all fluid supply systems through soft-ware adaptation.

THERMO-FLUID ANALYSIS ON THE HELIUM INJECTION COOLING OF GLASS FIBER FOR HIGH SPEED OPTICAL FIBER MANUFACTURING (광섬유 고속생산용 헬륨 주입식 유리섬유 냉각공정에 대한 열유동 해석)

  • Oh, I.S.;Kim, D.;Kwak, H.S.;Kim, K.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.92-95
    • /
    • 2011
  • In manufacturing optical fibers, the process starts with the glass fiber drawing from the heated and softened silica preform in the furnace, and the freshly drawn glass fiber is still at high temperature when it leaves the glass fiber drawing furnace. It is necessary to cool down the glass fiber to the ambient temperature before it then enters the fiber coating applicator, since the hot glass fiber is known to cause several technical difficulties in achieving high quality fiber coating. As the fiber drawing speed keeps increasing, a current manufacturing of optical fibers requires a dedicated cooling unit with helium gas injection. A series of three-dimensional flow and heat transfer computations are carried out to investigate the effectiveness of fiber cooling in the fiber cooling unit. The glass fiber cooling unit is simplified into the long cylindrical enclosure at which the hot glass fiber passes through at high speed, and the helium is being supplied through several injection slots of rectangular shape along the cooling unit. This study presents and discusses the effects of helium injection rates on the glass fiber cooling rates.

  • PDF

Analysis of Propagation of Negative Pressure Wave Due to Leak Through Damaged Hole in High Pressure Piping System (고압 배관망에서 배관 손상에 의한 누출 및 관내 저압확장파의 전파 특성 해석)

  • Kim, Wang-Yeun;Ha, Jong-Man;Ha, Tae-Woong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.11 no.1
    • /
    • pp.26-32
    • /
    • 2008
  • The safe operation of high pressure pipe line systems is of significant importance. Leaks due to faulty operation from the pipelines can lead to considerable product losses and to exposure of community to dangerous gases. There are several leak detection methods of pipeline network which have recently been suggested. The negative pressure wave detection technology, which has advantages of short time detection availability, accurate leaking location estimate capability and cost effective, is concentrated in this study. Theoretical analysis of the flow characteristics for leaking through a hole on the pipe wall has been performed by using Fluent 6.3, commercial CFD package. The results of 3-dimensional analysis near leaking hole confirm the occurrence of negative pressure wave, and the results of 2-dimensional analysis verify the characteristics of propagation of the wave which travels with speed equal to the speed of sound in the pipeline contents. Characteristics of leakage and pressure in a pipe with a hole have been analyzed for the various pipe and hole sizes.

A Study on the Mechanism of Clusters Formation of ER Fluid Through Visualization (가시화를 통한 ER유체의 클러스터 형성 구조에 관한 연구)

  • Lee, Eun-Jun;Park, Myeong-Gwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.12
    • /
    • pp.1684-1691
    • /
    • 2001
  • Electrorheological fluids(ERFs) show a rapid and reversible increase in apparent viscosity by applied electric field. It is called the electrorheological effect (ER effect). The reason for ER effect is the induction of an electric dipole in each particle, leading to the formation of clusters in the direction of the field, which resist fluid flow. Generally, the behavior of ER fluids has been modeled on those of Bingham fluids. But there are some differences between Bingham fluids and ER fluids. The visualization of ER fliuds are presented and ER effects by the forming, growing and breaking of clusters are discussed. In the low shear rate area, the pressure drop is measured by a pressure sensor and the formation of ER particles is visualized by video camera. The reason for the nonlinear behavior of ER fluids at low shear rate is explained through results of visualization. As result, the behavior of ER fluids is nonlinear at low shear rate with overshoot area because it is different to from the clusters according to the strength of electric field. The gap of electrodes becomes narrow because of the cluster layer occurrence near to electrodes in any conditions.

Influence of Circualr Casing on the Performance of Very Low Specific Speed Centrifugal Pump (원형케이싱이 극저비속도 원심펌프의 성능에 미치는 영향)

  • Choi, Young-Do;Kagawa, Shusaku;Kurokawa, Junichi
    • The KSFM Journal of Fluid Machinery
    • /
    • v.9 no.1 s.34
    • /
    • pp.32-39
    • /
    • 2006
  • Recently, according to the trend of small size in scale and high speed in rotation of turbomachinery, very low specific speed centrifugal pump is taking a growing interest because the pump is characterized by high head and low flow rate with convenience of manufacturing and maintenance compared with conventional positive displacement pump. However, the efficiency of the very low specific speed centrifugal pump drops rapidly with the decrease of specific speed. The purpose of this study is nor only to examine the influence of casing type on the performance of centrifugal pump in the range of very low specific speed but also to determine the proper casing type for the improvement of pump performance. The results show that circular casing is suitable for the centrifugal pump in the range of very low specific speed and the influence of impeller configuration on the pump performance is very small. Radial thrust in the circular and volute casings is considerably small in the range of very low specific speed.