• Title/Summary/Keyword: fluid and flow

Search Result 7,251, Processing Time 0.032 seconds

Effects of Flow Settling Means on the Performance of Fan Tester (유동안정화 장치가 홴 테스터의 성능에 미치는 영향)

  • Choi, Young-Seok;Kim, Deok-Su;Yoon, Joon-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.8 no.5 s.32
    • /
    • pp.29-34
    • /
    • 2005
  • In this study, the effect of flow settling means on the performance of fan tester were numerically investigated by using a computational fluid dynamics (CFD). The airflow rate was calculated from the pressure differential across a flow nozzle in the measuring plane and the flow settling means were generally installed in the chamber of the fan tester to provide proper airflow patterns ahead of the measuring plane. The predicted nozzle differential pressures with uniform inlet velocities were compared with the values of the ANSI/AMCA 210-99 to verify the performance of the commercial CFD code CFX 5.6. The influence of flow settling means on the measurement of airflow rate in a fan tester were discussed with various porosities and inlet jet velocities. The results obtained show that the proper band of porosities exist to meet the AMCA standard in a specified inlet jet velocity.

Cavitating Flow Simulation Using Two-Fluid Two-Phase Flow Model and HLL Scheme (이유체 이상유동 모델과 HLL 스킴을 이용한 캐비테이션 유동 해석)

  • Yeom Geum-Su;Chang Keun-Shik
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2005.04a
    • /
    • pp.219-222
    • /
    • 2005
  • A compressible two-fluid two-phase flow computation model using the stiffened-gas equation of state is formulated. Since the conservation equation system is of mixed type, it gives complex eigenvalues. The sonic speeds obtained from the individual single phase have been simply used in the literature for the fastest wave speeds necessary in the HLL scheme. This method has worked fine but proved to be quite diffusive according to our test. To improve the accuracy, we here propose to utilize the analytic eigenvalues evaluated from an approximate Jacobian matrix lot the fastest wave speeds. The interfacial transfer terms were dropped in constituting the Jacobian matrix for this purpose. The present scheme proved efficient, robust and accurate in comparison with other existing methods. We solved the cavitating flow problem using the present scheme. The result shows more detailed wave structure in the cavitating process caused by the strong expansion waves.

  • PDF

Effects of Flow Settling Means on the Performance of Fan Tester (유동안정화 장치가 홴 테스터의 성능에 미치는 영향)

  • Choi Young-Seok;Kim Deok-Su;Yoon Joon-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.9 no.4 s.37
    • /
    • pp.43-48
    • /
    • 2006
  • In this study, the effect of flow settling means on the performance of fan tester were numerically investigated by using a computational fluid dynamics(CFD). The airflow rate was calculated from the pressure differential across a flow nozzle in the measuring plane and the flow settling means were generally installed in the chamber of the fan tester to provide proper airflow patterns ahead of the measuring plane. The predicted nozzle differential pressures with uniform inlet velocities were compared with the values of the ANSI/AMCA 210-99 to verify the performance of the commercial CFD code CFX 5.6. The influence of flow settling means on the measurement of airflow rate in a fan tester were discussed with various porosities and inlet jet velocities. The results obtained show that the proper band of porosities exist to meet the AMCA standard in a specified inlet jet velocity.

Prediction of the Flow Coefficient of a PFA Lined Ball Valve Using the CFD Simulation Method (CFD 해석방법을 이용한 PFA 라이닝 볼밸브의 유량계수 예측)

  • Jeon, Hong-Pil;Lee, Won-Seob;Kim, Chul-Soo;Lee, Jong-Chul
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.4
    • /
    • pp.35-38
    • /
    • 2016
  • A PFA lined ball valve, which is machined with fluorinated resin PFA to its inner part for improving corrosion resistance, non-stickness, heat-resistance, has been widely used in semiconductor/LCD manufacturing processes with the high purity chemicals as working fluid. Due to the safety concerns, the experiments for measuring the flow coefficient of a PFA lined ball valve should be conducted with water at room temperature according to IEC standards. However, it is required to know the real flow coefficient with the real working fluid, because the flow coefficient is critical to correctly design valves in piping system. In this study, we calculated the flow coefficient of a PFA lined ball valve 40A with hydrochloric acid ($40^{\circ}C$ 36% HCl) as the working fluid using a commercial CFD package, ANSYS CFX v15. The computational results had a good agreement with the measured data and showed a little difference between water and hydrochloric acid as the working fluid of a PFA lined ball valve.

A Study on the Two-dimensional Formation Control of Free Surface of Magnetic Fluid by Electromagnetic Force (전자기력에 의한 자성유체의 2차원 자유표면 형상 제어에 관한 연구)

  • Bae Hyung-Sub;Yang Taek-Joo;Lee Yuk-Hyung;Joo Dong-Woo;Park Myeong-Kwan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.3 s.168
    • /
    • pp.29-37
    • /
    • 2005
  • In this study, the control of the free surface deformation of a magnetic fluid for the change in electromagnetic force is discussed. The free surface of magnetic fluid is formed by the balance of surface force, gravity, pressure difference, magnetic normal pressure and magnetic body force. Magnetic fluid in characteristics of fluid adjusted to the opposite direction of the gravity direction. Thus, the device of a magnetic fluid proposed the complete zero-leakage sealing, oscillator for surface control, boundary layer control, MHD, flow control, flow using magnetic levitation system and surface actuator. This study show the deformation of surface rise due to the intensity of the magnetic field and possibility of two-dimensional control of magnetic fluid through the feedback data of hall sensor.

Determination of Eccentric Axis for Pump Control Valve Using the Characteristic Function (특성함수를 이용한 펌프 제어 밸브의 편심축 결정)

  • Shin, Myung-Seob;Yi, Sang-Il;Park, Gyung-Jin;Yoon, Joon-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.11 no.3
    • /
    • pp.43-49
    • /
    • 2008
  • The pump control valve is a butterfly valve that has an eccentric rotating axis. It is not only used as a butterfly valve to control the flow rate or pressure, but also as a check valve to prevent backward flow. A new design method of eccentric rotating axis is proposed to design the valve. The height of the rotating axis is determined through flow field analysis. A general purpose of computational fluid dynamics software system, Fluent is used to simulate the fluid flow. Flow field analysis is performed for various heights of the rotating axis and different opening angles of the valve. A characteristic function is defined for estimating the flow characteristics based on the results of flow field analysis. The characteristic function is defined in order to determine the height of the rotating axis. An optimization problem with a characteristic function is formulated to determine the amount of eccentricity. The height of the Totaling axis of the valve is determined through solving the optimization problem.

An analysis of fluid flow In U-bend area of laminated plate heat exchanger (적층형 판 열교환기의 U턴부 유동해석)

  • 이관수;박철균;정지완
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.3
    • /
    • pp.348-357
    • /
    • 1998
  • The flow characteristics inside U-bend tube of the laminated plate heat exchanger were numerically investigated. The behavior of fluid flow, and the variations of the faulty area and friction factor are examined according to the distance between the span and the wall and the diameter of the round attacked to the end of span. The results show that the diameter(d) of the round attached to the span is mainly associated with the smooth circulation of fluid flow rather than the size of faulty area and the friction factor. As the distance($\ell$) between the span and the wall decreases, the faulty area decreases, however the friction factor dramatically increases. It is also found that one can obtain a good result in the view of the flow characteristics and pressure drop at d=7.5mm and $\ell$=30.5mm.

  • PDF

A Study on the Fluid Flew with Ultrasonic Forcing by PIV Measurement (초음파가 가진된 유체유동의 PIV계측에 의한 연구)

  • 주은선;이영호;나우정;정진도
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.6
    • /
    • pp.1281-1290
    • /
    • 2001
  • A study on the fluid flow with ultrasonic forcing is carried out to obtain data for the turbulence enhancement. A large water tank is made of the transparent acrylic plates and a horizontal flow field is given by setting two acrylic tubes to face mutually on a horizontal line. A 2-dimensional PlV system which is composed of a continuous-output 4W Argon-ion laser, a high-speed video camera, a PC based by an image grabber and a high resolution monitor is used to investigate characteristics of the complex turbulence flow field. And a 2MHz ultrasonic transducer is used fur ultrasonic vibration forcing. Some experiments are carried out at Reynolds numbers of 2,000 and 4,000 and at 7 angles of ultrasonic incidence. In results, the flew velocity vector distribution, kinetic energy and turbulence intensity in both cases of with and without ultrasonic forcing are examined, compared and discussed by using PIV measurement. It is clarified that the ultrasonic forcing into flow field is valid to obtain the turbulence enhancement.

  • PDF

Stability Analysis of Multi-wall Carbon Nanotubes Conveying Fluid (유체유동에 의한 다중벽 탄소나노튜브의 안정성 해석)

  • Song, Oh-Seop;Yun, Kyung-Jae
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.6
    • /
    • pp.593-603
    • /
    • 2010
  • In this paper, vibration and flow-induced flutter instability analysis of cantilever multi-wall carbon nanotubes conveying fluid and modelled as a thin-walled beam is investigated. Non-classical effects of transverse shear and rotary inertia and van der Waals forces between two walls are incorporated in this study. The governing equations and the associated boundary conditions are derived through Hamilton's principle. Numerical analysis is performed by using extend Galerkin method which enables us to obtain more exact solutions compared with conventional Galerkin method. Cantilevered carbon nanotubes are damped with decaying amplitude for flow velocity below a certain critical value, however, beyond this critical flow velocity, flutter instability may occur. Variations of critical flow velocity with both radius ratio and length of carbon nanotubes are investigated and pertinent conclusion is outlined.

Simulation of Heat and Fluid Flow in the Single Screw Extruder with Coupling of the Metering Section and Die (단축 스크류 압축기에서 계량화부와 다이를 동시에 고려한 열 및 유동해석)

  • Yoon, Jung-Bae;Kwag, Dong-Seong;Kim, Woo-Seung
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.246-251
    • /
    • 2000
  • In the present study, the analysis on heat and fluid flow in the single screw extruder is carried out by simultaneously considering the metering section and the die. The finite difference method and the finite volume method are applied to the metering section and the die, respectively. The zonal method is used to couple the metering section and the die. To investigate the effect of die on the characteristics of heat and fluid flow in the single screw extruder, the pressure back flow is included in the analysis. The screw-tip rotation is also considered by employing the quasi 3-dimensional die model. The present results are compared with the numerical and experimental data available in the literatures.

  • PDF