고분자 전해질 연료 전지용 공기공급계의 동특성 및 성능에 대한 연구 (Study on Dynamic Characteristic & Performance of the Air Supply System for PEM Fuel Cell)

  • 이희섭;김창호;이용복
    • 한국유체기계학회 논문집
    • /
    • 제9권6호
    • /
    • pp.45-53
    • /
    • 2006
  • Turbo-blower as an air supply system is one of the most important BOP (Balance of Plant) systems for FCV(Fuel Cell Vehicle). For generating and blowing compressed air, the motor of air blower consumes maximum 25% of net power, and fuel cell demands a clean air. In this study, turbo-blower supported by air foil bearings is introduced as the air supply system used by 80kW proton exchange membrane fuel systems. The turbo-blower is a turbo machine which operates at high speed, so air foil bearings suit their purpose as bearing elements. Analysis for confirming the stability and endurance is conducted. The rotordynamic stability was predicted using the numerical analysis of air foil bearings and it is verified through experimental works. In spite of various transient dynamic situation, the turbo-blower had stable performances. After the performance test, results are presented. The normal power of driving motor has about 1.6 kW with the 30,000 rpm operating range and the flow rate of air has maximum 160 SCFM. The test results show that the aerodymic performance and stability of turbo-blower are satisfied to the primary goals.

공압 수직실린더의 쿠션특성에 관한 실험적 연구 (An Experimental Study on Cushion Characteristics of pneumatic Cylinder for Vertically-Mounted.)

  • 김동수;김형의;이상천
    • 연구논문집
    • /
    • 통권28호
    • /
    • pp.73-87
    • /
    • 1998
  • A pneumatic control system of compressed air as a working fluid has a variety of advantages such as low price, high respondence, non-explosion and good control performance and thus has many applications in the field of automobile, electronic and semiconductor industry. However, it has a difficulty in contolling a precise position due to quick response of system and compressibility of working fluid and. in particular, shock stress may occur due to an external load, resulting in fracture of a cylinder cap unless cushion device is equipped in the linear actuator. To avoid this, a cushion device should be installed for damping effect of the external load and the supply pressure as well as for decreasing shock stress and vibration caused by high speed rotation. Previous studies include dimensionless analyses and computer simulations of cushion capability and experiments of horizontally-mounted cylinder performances. A new attempt is experimentally made in this study using a vertically-mounted cylinder under an operation condition of 4, 5 and 6 (bar) as supply pressure and 40, 70 and 100 (kgf) as external load. It turns out that the cushion pressure is mainly a function of the external load rather than the supply pressure. The cushion characteristics was also revealed in the meter-in circuit.

  • PDF

고압수소 밸브의 시동 특성에 관한 수치적 연구 (A Numerical Study on the Opening Characteristics of High Pressure Hydrogen Valves)

  • 김상민;김진성;조영준;양시원;신문성
    • 한국수소및신에너지학회논문집
    • /
    • 제34권6호
    • /
    • pp.689-697
    • /
    • 2023
  • The high-pressure hydrogen valve is intended to supply hydrogen charged at high pressure in the hydrogen tank to the fuel cell stack, which decompresses high-pressure hydrogen gas to low pressure and primarily limits the excessive flow. It consists of a pilot valve, a main valve, and a excessive flow valve to operate in a wide pressure range from 2 to 70 MPa of charging pressure. The opening characteristics of the valve were confirmed by computation fluid dynamics applying the moving grid technique. The behavior of the valve was predicted by predicting the force acting on the valve over time. In addition, the difference in behavior according to supply pressure was compared.

온수 급탕 및 난방을 위한 히트 펌프 태양열 시스템의 성능 분석 (Performance Analysis of Solar Thermal System with Heat Pump for Domestic Hot Water and Space Heating)

  • 손진국
    • 한국태양에너지학회 논문집
    • /
    • 제38권5호
    • /
    • pp.49-62
    • /
    • 2018
  • This study aims to analyze the performance of solar thermal system with heat pump for domestic hot water and heat supply. There are four types of system. Systems are categorized based on the existence of a heat pump and the ways of controlling the working fluid circulating from the collector. Working fluid is controlled by either temperature level (categorized as system 1 and 2) or sequential flow (system 3 and 4). Heat balance of the system, the solar fraction, hot water and heating supply rates, and performance of heat pump are analyzed using TRNSYS and TESS component programs. Technical specifications of the main facilities are as follow; the area of the collector to $25m^2$, the volumes of the main tank and the buffer tank to $0.5m^3$ and $0.8m^3$, respectively. Heating capacity of the heat pump in the heating mode is set to 30,000 kJ / hr. Hot water supply set 65 liters per person each day, total heat transfer coefficient of the building to 1,500 kJ / kg.K. Indoor temperature is kept steadily around $22^{\circ}C$. The results are as follows; 6 months average solar fraction of system 1 turns out to be 39%, which is 6.7% higher than system 2 without the heat pump, indicating a 25% increase of solar fraction compared to that of system 2. In addition, the solar fraction of system 1 is 2% higher than that of system 3. Hot water and heating supply rate of system 1 are 93% and 35%, respectively. Considering the heat balance of the system, higher heat efficiency, and solar fraction, as whole, it can be concluded that system 1 is the most suitable system for hot water and heat supply.

대형 풍력발전기 부품의 극한 환경 시험을 위한 극저온 챔버의 열유동 해석에 대한 연구 (STUDY ON THE THERMAL-FLUID ANALYSIS OF CRYOGENIC CHAMBER FOR COLD CLIMATE TEST OF LARGE WIND TURBINE PARTS)

  • 김민규;강율호;박원규
    • 한국전산유체공학회지
    • /
    • 제20권3호
    • /
    • pp.8-14
    • /
    • 2015
  • More and more, spaces are decreasing which satisfy multiple requirements for wind power plants. However, areas which have excellent wind resources and are free to civil complaints occupy a large space, although they are exposed to the cryogenic environment. This study conducted a thermal-fluid analysis of a cryogenic chamber for testing large wind turbine parts exposed to the cryogenic environment. The position of supply air is placed to the upper area to compare each cooling performance for each location of various outlets in mixing ventilated conditions. The study carried out CFD analysis for the chamber both with and without a test object. For the cases without the test object, the air temperature of the upper supply and down extract type chamber was cooled faster by 5-100% than the others. However, for the cases with the test object, the object temperature of upper supply and center extract on the opposite side type chamber was cooled faster by 33-132% than the others. The cooling performance by the air inside the chamber and the test object did not show the same pattern, which implicates the need to consider the cooling performance by not only the air but also the test object in the large cryogenic chamber design for testing large parts.

데이터센터의 급기온도 변화가 서버 냉각 성능에 미치는 영향에 대한 연구 (A Study on the Effects of Supply Air Temperature on the Server Cooling Performance in a Data Center)

  • 장현재
    • 설비공학논문집
    • /
    • 제30권2호
    • /
    • pp.83-91
    • /
    • 2018
  • A datacenter is a high energy consuming facility whose cooling energy consumption rate is 10~20 times larger than general office buildings. The higher the temperature of supply air from a CRAC (computer room air-conditioner) is supplied, the more energy efficient cooling is possible because of improving the COP of a chiller and advanced range of outdoor air temperature available for the economizer cycles. However, because the temperature of cold air flowing into server computers varies depending on air mixing configurations in a computer room, the proper supply air temperature must be considered based on the investigation of air mixing and heat dissipation. By these, this study aims to understand the effects of variation of the supply air temperature on the air flow distributions, temperature distributions and rack cooling efficiencies. Computational fluid dynamics (CFD) aided in conducting the investigation. As a result, the variation of the supply air temperature does not affect the air flow distributions. However, it mainly affects the temperature distribution. From the results of CFD simulations, Rack cooling indices (RCIHI and RCILO) were evaluated and showed the ideal state set at $19^{\circ}C$ of the supply air temperature.

진액(津液)의 유무(有無)에 따른 『상한잡병론(傷寒雜病論)』의 통증(痛症) 치법(治法)에 관하여(태양병편을 중심으로) (Pain management in 『Treatise on Cold Damage and Miscellaneous Disease』 according to sufficiency-deficiency of fluid and humor (mainly with greater yang disease part))

  • 이명철;강연석
    • 한국의사학회지
    • /
    • 제27권2호
    • /
    • pp.135-143
    • /
    • 2014
  • Human body fluid and humor include not only sweat, joint fluid but also every fluids, for example, blood, essence, kidney essence and marrow. Historically, in the oriental medicine, there are a lot of efforts in order to preserve fluid and humor. In "Treatise on Cold Damage and Miscellaneous Disease (傷寒雜病論)", when treating cold damage, preservation of fluid and humor is put first. I tried to find out the relation about fluid and humor and pain treatment in "Treatise on Cold Damage and Miscellaneous Disease". So, I investigated sentences related to pains in "Treatise on Cold Damage and Miscellaneous Disease" "greater yang disease part" and commentaries of several chinese medical doctors. And I divide pain treatments into four categories. (fluid and humor sufficiency-exterior pattern, fluid and humor sufficiency-interior pattern, fluid and humor deficiency-exterior pattern, fluid and humor deficiency-interior pattern) At first, when treating pains of cold damage, there are many considerations about deficiency and sufficiency of fluid and humor through pulse condition and symptoms. Second, in pain-cases of fluid and humor sufficiency, purge methods is chosen. And in pain-cases of fluid and humor deficiency, tonifying methods is chosen. Finally, one of the main objects of "Treatise on Cold Damage and Miscellaneous Disease" is preservation and supply of fluid and humor.

자기 유변 유체와 영구 자석을 이용한 회전 엑츄에이터의 개발 (MR rotary brake development with permanent magnet)

  • 권순우;박영진
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.183-186
    • /
    • 1997
  • This paper presents the new MR rotary brake with a permanent magnet, based on the shear operating mode. Due to the permanent magnet, the MR rotary brake can give the nominal resistance to the external disturbance and give the fail safe capacity to the system even when the power supply is accidentally cut off. As we apply the positive or negative current to the electric magnet coil, the resistance torque of the MR rotary brake can be reduced to the value less than the nominal resistance or increased up to the magnetic saturation point.

  • PDF

유막의 온도변화를 고려한 플로팅 링 저어널베어링의 성능해석 (An Analysis of Performance of Floating-Ring Journal Bearing Including Thermal Effects)

  • 김종수;최상규;유광택
    • Tribology and Lubricants
    • /
    • 제17권2호
    • /
    • pp.130-137
    • /
    • 2001
  • In this paper, the thermal effects on the performance of floating ring journal bearing are investigated theoretically. The numerical analyses include pressure drop at inner film due to a centrifugal force, fluid momentum effects of supply oil into inner film and thermal effects in lubricating films. All performance data are presented as the rotating speed of journal from 10,000 rpm to 70,000 rpm.