Activation Reduction Method for a Concrete Wall in a Cyclotron Vault

  • Kumagai, Masaaki;Sodeyama, Kohsuke;Sakamoto, Yukio;Toyoda, Akihiro;Matsumura, Hiroshi;Ebara, Takayoshi;Yamashita, Taichi;Masumoto, Kazuyoshi
    • Journal of Radiation Protection and Research
    • /
    • v.42 no.3
    • /
    • pp.141-145
    • /
    • 2017
  • Background: The concrete walls inside the vaults of cyclotron facilities are activated by neutrons emitted by the targets during radioisotope production. Reducing the amount of radioactive waste created in such facilities is very important in case they are decommissioned. Thus, we proposed a strategy of reducing the neutron activation of the concrete walls in cyclotrons during operation. Materials and Methods: A polyethylene plate and B-doped Al sheet (30 wt% of B and 2.5 mm in thickness) were placed in front of the wall in the cyclotron room of a radioisotope production facility for pharmaceutical use. The target was Xe gas, and a Cu block was utilized for proton dumping. The irradiation time, proton energy, and beam current were 8 hours, 30 MeV, and $125{\mu}A$, respectively. To determine a suitable thickness for the polyethylene plate set in front of the B-doped Al sheet, the neutron-reducing effects achieved by inserting such sheets at several depths within polyethylene plate stacks were evaluated. The neutron fluence was monitored using an activation detector and 20-g on de Au foil samples with and without 0.5-mm-thick Cd foil. Each Au foil sample was pasted onto the center of a polyethylene plate and B-doped Al sheet, and the absolute activity of one Au foil sample was measured as a standard using a Ge detector. The resulting relative activities were obtained by calculating the ratio of the photostimulated luminescence of each foil sample to that of the standard Au foil. Results and Discussion: When the combination of a 4-cm-thick polyethylene plate and B-doped Al sheet was employed, the thermal neutron rate was reduced by 78%. Conclusion: The combination of a 4-cm-thick polyethylene plate and B-doped Al sheet effectively reduced the neutron activation of the investigated concrete wall.

Prediction of Atomic Oxygen Erosion for Coating Material of LEO Satellite's Solar Array by Using the Real Ram Direction Accumulation Method (실 궤도면 누적량 계산법을 활용한 원자산소의 저궤도위성 태양전지판 코팅재료 침식량 예측)

  • Kim, You-Gwang;Lee, Sang-Taek;Baek, Myung-Jin;Lee, Suk-Hoon
    • Journal of Aerospace System Engineering
    • /
    • v.11 no.5
    • /
    • pp.1-5
    • /
    • 2017
  • This objective of this study is an effort to predict atomic oxygen (ATOX) erosion as ot affects coating material(s) of LEO satellite's solar array by implementing the 'real ram direction accumulation method'. We observed the difference of ATOX Fluence between the previous 'Maximum worst case estimation method' and 'Real ram direction accumulation method' and we plan to implement these findings for the purpose of evaluating the level of compliance for design submitted by solar array suppliers. We used the SPENVIS(Space Environment Information System) served by ESA based on assumption orbit information, and applied the satellite orbit calculation software for calculating the ATOX Flux crushed solar array in real orbit surface.

Parametric Studies of Pulsed Laser Deposition of Indium Tin Oxide and Ultra-thin Diamond-like Carbon for Organic Light-emitting Devices

  • Tou, Teck-Yong;Yong, Thian-Khok;Yap, Seong-Shan;Yang, Ren-Bin;Siew, Wee-Ong;Yow, Ho-Kwang
    • Journal of the Optical Society of Korea
    • /
    • v.13 no.1
    • /
    • pp.65-74
    • /
    • 2009
  • Device quality indium tin oxide (ITO) films are deposited on glass substrates and ultra-thin diamond-like carbon films are deposited as a buffer layer on ITO by a pulsed Nd:YAG laser at 355 nm and 532 nm wavelength. ITO films deposited at room temperature are largely amorphous although their optical transmittances in the visible range are > 90%. The resistivity of their amorphous ITO films is too high to enable an efficient organic light-emitting device (OLED), in contrast to that deposited by a KrF laser. Substrate heating at $200^{\circ}C$ with laser wavelength of 355 nm, the ITO film resistivity decreases by almost an order of magnitude to $2{\times}10^{-4}\;{\Omega}\;cm$ while its optical transmittance is maintained at > 90%. The thermally induced crystallization of ITO has a preferred <111> directional orientation texture which largely accounts for the lowering of film resistivity. The background gas and deposition distance, that between the ITO target and the glass substrate, influence the thin-film microstructures. The optical and electrical properties are compared to published results using other nanosecond lasers and other fluence, as well as the use of ultra fast lasers. Molecularly doped, single-layer OLEDs of ITO/(PVK+TPD+$Alq_3$)/Al which are fabricated using pulsed-laser deposited ITO samples are compared to those fabricated using the commercial ITO. Effects such as surface texture and roughness of ITO and the insertion of DLC as a buffer layer into ITO/DLC/(PVK+TPD+$Alq_3$)/Al devices are investigated. The effects of DLC-on-ITO on OLED improvement such as better turn-on voltage and brightness are explained by a possible reduction of energy barrier to the hole injection from ITO into the light-emitting layer.

The Theory of Change in Nursing Practice

  • Gas, Du
    • Journal of Korean Academy of Nursing
    • /
    • v.9 no.2
    • /
    • pp.1-6
    • /
    • 1979
  • The topic I have chosen for presentation to you today is entitled, the theory of change in nursing practice or to put it into simpler words. How do new ideas in nursing get started - Where do they come from\ulcorner - How are these ideas spread through the social system of nurses\ulcorner - What makes some Directors of Nursing more ready to accept change than others\ulcorner What factors in-fluence than to introduce change\ulcorner The process of change has been the subject of considerable research in such diverse disciplines and fields as anthropology and rural sociology, marketing and, also, education, for many years. The studies are called“diffusion”studies, or sometimes“adoption”studies, or“adoption of innovation”studies. They deal specifically with the transmission of innovations to members of a social system, and are considered a subset of research in the general field of communication, Although a number of studies have been undertaken in medicine, and, in the past decade, numerous ones in education, there have been few studies on the process of change in nursing. Yet, nursing has undergone tremendous changes in the past 10 years - the nursing process has been introduced, there is the expanded role of the nurse which is rapidly becoming a regular mode of practice - and many, many more changes, We seem to be always running to try. to keep up with changes that have already taken place. Yet little is known about known about the process of change itself - how practitioners learn about new ideas and techniques, or about the factors which influence nurses to accept some changes and reject others. The purpose of the study I am about. to describe was to analyze the process of change as it functioned in regard to nursing innovations in a selected segment of Canadian hospitals, and to relate the analysis to general research and theory about information transmission and the acceptance of change. Three aspects of the process were investigated : 1. The flow of information about changes in nursing practice through a network of hospitals. 2. Factors influencing the adoption of changes in nursing practice. 3. Factors influencing delay in the adoption process, the rejection of changes, or their discontinuance following adoption.

  • PDF

Fast Neutron Dosimetry with Two Threshold Detectors in Criticality Accidents of Nuclear Reactors

  • Ro, Seung-Gy
    • Nuclear Engineering and Technology
    • /
    • v.2 no.2
    • /
    • pp.85-95
    • /
    • 1970
  • An attempt has been made to do interpretation of the fast neutron dose with two threshold detectors incorporated with the Harwell criticality locket. This method is based on the assumption that the spectral distribution of fission neutrons in criticality accidents may be governed by one spectral parameter. The surface-absorbed dose for a unit fission neutron fluence seems to be insensitive to spectral shifts of the fission neutron spectrum. The average cross-sections for the activation detectors, however, are considerably changed with the neutron spectral shape, which may lead to a large error in calculating the dose from the reaction rate if one uses a fixed value for the average cross sections regardless of the neutron spectral distribution. Besides, the doses calculated from three representative formulae for fission neutron spectra have been compared : these formulae are Watt, Cranberg at al. and Maxwellian forms. The results obtained front the Maxwellian formula show a departure from the Watt and Cranberg's, both being similarly close.

  • PDF

IRRADIATION DEVICE FOR IRRADIATION TESTING OF COATED PARTICLE FUEL AT HANARO

  • Kim, Bong Goo;Park, Sung Jae;Hong, Sung Taek;Lee, Byung Chul;Jeong, Kyung-Chai;Kim, Yeon-Ku;Kim, Woong Ki;Lee, Young Woo;Cho, Moon Sung;Kim, Yong Wan
    • Nuclear Engineering and Technology
    • /
    • v.45 no.7
    • /
    • pp.941-950
    • /
    • 2013
  • The Korean Nuclear-Hydrogen Technology Development (NHTD) Plan will be performing irradiation testing of coated particle fuel at HANARO to support the development of VHTR in Korea. This testing will be carried out to demonstrate and qualify TRISO-coated particle fuel for use in VHTR. The testing will be irradiated in an inert gas atmosphere without on-line temperature monitoring and control combined with on-line fission product monitoring of the sweep gas. The irradiation device contains two test rods, one has nine fuel compacts and the other five compacts and eight graphite specimens. Each compact contains about 260 TRISO-coated particles. The irradiation device is being loaded and irradiated into the OR5 hole of the in HANARO core from August 2013. The device will be operated for about 150 effective full-power days at a peak temperature of about $1030^{\circ}C$ in BOC (Beginning of Cycle) during irradiation testing. After a peak burn-up of about 4 atomic percentage and a peak fast neutron fluence of about $1.7{\times}10^{21}\;n/cm^2$, PIE (Post-Irradiation Examination) of the irradiated coated particle fuel will be performed at IMEF (Irradiated Material Examination Facility). This paper reviews the design of test rod and irradiation device for coated particle fuel, and discusses the technical results for irradiation testing at HANARO.

A study on selective hybrid-structure film fabricated by 355nm UV-pulsed laser processing (355nm UV 레이저를 이용한 선택적 하이브리드 구조 필름의 제작에 관한 연구)

  • Kim, Myung-Ju;Lee, Sang-Jun;Shin, Bo-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.2979-2984
    • /
    • 2015
  • This paper has presented a new foaming technology of selective hybrid-structured polymer film with expanded pores. The porous structure of closed pore was firstly fabricated by applying the 355nm UV-pulsed laser to 0.1mm thick film that was uniformly mixed with PP pellets, copper powder, and CBA (Chemical Blowing Agent). In order to expand pore size of closed-cell shape, LAMO(Laser Aided Micro pore Opening) processing was conducted to heat the copper powder, and then the bigger pore size of closed-cell more than existing pore size was successfully formed because of rapid conduction of heated metal powder. From the experimental results, various process parameters such as laser fluence, intensity, scan rate, spot size and density of powder and CBA were considerably considered to reveal the correlation among the pore characteristics. In the future, a function experiment will be carried out to use the hybrid film of industrial applications.

Hydrophilic property by contact angle change of ion implanted polycarbonate (이온주입 Polycarbonate의 접촉각 변화에 의한 친수특성)

  • Lee, Chan-Young;Lee, Jae-Hyung;Lim, Kee-Joe
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.533-538
    • /
    • 2003
  • It has been shown that ion implantation produces remarkable improvements in surface-sensitive physical and chemical properties as well as other mechanical properties, in polymers. In this study, ion implantation was performed onto polymer, PC(polycarbonate), in order to investigate surface hydrophilic property through contact angle measurement using distilled water. PC was irradiated with N, Ar, Xe ions at the irradiation energy of $20\;{\sim}\;50keV$ and the dose range of $5{\times}10^{15},\;1{\times}10^{16},\;7{\times}10^{16}\;ions/cm^2$. The contact angle of water has been reduced with increasing fluence and ion mass but increased with increasing implanted energy. The changes of chemical and structural property are discussed in view of infrared spectroscopy and FT-IR, XPS, which shows increasing C-O bonding and C-C bonding. The root mean square of surface roughness examined by means of AFM changed smoothly from 0.387nm to 0.207nm and the change of wettability was discussed with respect to elastic and inelastic collisions obtained as results of TRIM simulation. It was found that wettability of the modified PC surface was affected on change of functional group and nuclear stopping or linear energy transfer(LET, energy deposited per unit track length per ion) that causes chain scission by displacing atom from polymer chains, but was not greatly dependant on surface morphology.

  • PDF

Performance Analysis of The KALIMER Breakeven Core Driver Fuel Pin Based on Conceptual Design Parameters

  • Lee Dong Uk;Lee Byoung Oon;Kim Young Gyun;Lee Ki Bog;Jang Jin Wook
    • Nuclear Engineering and Technology
    • /
    • v.35 no.4
    • /
    • pp.356-368
    • /
    • 2003
  • Material properties such as coolant specific heat, film heat transfer coefficient, cladding thermal conductivity, surface diffusion coefficient of the multi-bubble are improved in MACSIS-Mod1. The axial power and flux profile module was also incorporated with irradiation history. The performance and feasibility of the updated driver fuel pin have been analyzed for nominal parameters based on the conceptual design for the KALIMER breakeven core by MACSIS-MOD1 code. The fuel slug centerline temperature takes the maximum at 700mm from the bottom of the slug in spite of the nearly symmetric axial power distribution. The cladding mid-wall and coolant temperatures take the maximum at the top of the pin. Temperature of the fuel slug surface over the entire irradiation life is much lower than the fuel-clad eutectic reaction temperature. The fission gas release of the driver fuel pin at the end of life is predicted to be $68.61\%$ and plenum pressure is too low to cause cladding yielding. The probability that the fuel pin would fail is estimated to be much less than that allowed in the design criteria. The maximum radial deformation of the fuel pin is $1.93\%$, satisfying the preliminary design criterion ($3\%$) for fuel pin deformation. Therefore the conceptual design parameters of the driver fuel pin for the KALIMER breakeven core are expected to satisfy the preliminary criteria on temperature, fluence limit, deformation limit etc.

Measurement of Photo-Neutron Dose from an 18-MV Medical Linac Using a Foil Activation Method in View of Radiation Protection of Patients

  • Yucel, Haluk;Cobanbas, Ibrahim;Kolbasi, Asuman;Yuksel, Alptug Ozer;Kaya, Vildan
    • Nuclear Engineering and Technology
    • /
    • v.48 no.2
    • /
    • pp.525-532
    • /
    • 2016
  • High-energy linear accelerators are increasingly used in the medical field. However, the unwanted photo-neutrons can also be contributed to the dose delivered to the patients during their treatments. In this study, neutron fluxes were measured in a solid water phantom placed at the isocenter 1-m distance from the head of an18-MV linac using the foil activation method. The produced activities were measured with a calibrated well-type Ge detector. From the measured fluxes, the total neutron fluence was found to be $(1.17{\pm}0.06){\times}10^7n/cm^2$ per Gy at the phantom surface in a $20{\times}20cm^2$ X-ray field size. The maximum photo-neutron dose was measured to be $0.67{\pm}0.04$ mSv/Gy at $d_{max}=5cm$ depth in the phantom at isocenter. The present results are compared with those obtained for different field sizes of $10{\times}10cm^2$, $15{\times}15cm^2$, and $20{\times}20cm^2$ from 10-, 15-, and 18-MV linacs. Additionally, ambient neutron dose equivalents were determined at different locations in the room and they were found to be negligibly low. The results indicate that the photo-neutron dose at the patient position is not a negligible fraction of the therapeutic photon dose. Thus, there is a need for reduction of the contaminated neutron dose by taking some additional measures, for instance, neutron absorbing-protective materials might be used as aprons during the treatment.