• Title/Summary/Keyword: flow test

Search Result 6,504, Processing Time 0.038 seconds

The Simulation of Semicale Natural Circulation Test 5-NC-3,S-NC-4 Using RELAP5/Mod3.1

  • Kim, S. N.;W. H. Jang
    • Nuclear Engineering and Technology
    • /
    • v.30 no.5
    • /
    • pp.424-434
    • /
    • 1998
  • RELAP5/Mod3.1 code was assessed with the semiscale experiment S-NC-3, and S-NC-4, which simulated the two-phase natural circulation and reflux condensation for the SBLOCA of PWR, respectively . Test S-NC-3 and S-NC-4 calculation results showed that RELAP5/Mod3.1 quite well describes the influence of steam generator secondary side heat transfer degradation on both two-phase natural circulation and reflux condensation. A comparison between the calculated and measured two-phase mass flow rate in test S-NC-3 shows good agreement for primary mass inventory more than 92%. And RELAP5/Mod3.1 have a good mass flow rate prediction capability for the transient such as S-NC-4 except some flow oscillations. The reflux flow rate for S-NC-4 test is under predicted, and the overall results verify that the correct prediction of the reduced liquid level appears to be required for the correct calculation of the overall phenomena.

  • PDF

Performance Analysis of a Flow Passage Opening Device through Low Speed Aircraft Captive Flight Tests

  • Jung, Sung-Min;Park, Jeong-Bae
    • International Journal of Aerospace System Engineering
    • /
    • v.4 no.2
    • /
    • pp.5-9
    • /
    • 2017
  • In a pressurized fuel supply system of aircraft, a flow passage opening device is required to keep fuel continuously transferred from one tank to the other. The device utilizes balancing weights in order to follow up an acceleration at special conditions such as negative g. It is very difficult to test the device in a real high-speed and high-altitude test since severe test conditions and expensive supports are needed. Therefore, this paper deals with performance analysis of a flow passage opening device through low speed aircraft captive flight tests (CFT) including roll and negative-g maneuvers. It is shown that balancing weights in the device can open the passage in accordance with fuel position.

A Study on the Determination of Material Property by Cylinder Compression Test (원기둥 압축 시험을 통한 소재의 물성치 평가에 관한 연구)

  • Cha, Do-Sung;Choi, Hong-Seok;Kim, Nak-Soo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.9 s.252
    • /
    • pp.1049-1061
    • /
    • 2006
  • In the study, the flow stress of material and friction condition were determined by using the cylinder compression test and numerical method. We proposed the flow stress equation including the initial yield strength to predict it from the upper bound method. The upper bound technique uses the velocity field which includes two unknowns to effectively express bulging. Also, inverse engineering technique uses the object function to minimize area enclosed by load-stroke curve. The friction factor is determined from the radius of curvature of the barrel by cylinder compression test. Flow stress and initial yield strength predicted from the above techniques are verified through the finite element simulation.

A Study on the Standardization of Test Method of Flat-Plate Liquid-heating Solar Collectors (액체식 평판형 태양열 집열기 성능 실험의 표준화에 관한 연구)

  • 윤석범
    • Journal of the Korean Society of Safety
    • /
    • v.5 no.3
    • /
    • pp.27-32
    • /
    • 1990
  • Standardization of solar collector test method is desirable for improvement solar collector quality and Valuation of collector thermal performance. In the present work, test loop proposed by Chun, is modified for convenience of test and obtained accurate collector thermal performance. An experimental investigation hat been carried out with a modified collector test loop under a real sun condition in order to confirm the utility of modified test loop and study the effect of variation of flow rate on thermal efficiency, the range of optimum flow rate and critical incident angle.

  • PDF

Design and Test of ASME Strainer for Coolant System of Research Reactor (연구용 원자로 냉각계통의 ASME 스트레이너 설계 및 성능시험)

  • Park, Yong-Chul;Park, Jong-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.2 no.3 s.4
    • /
    • pp.24-29
    • /
    • 1999
  • The ASME strainers have been newly installed at the suction side of each reactor coolant pump to get rid of the foreign materials which may damage the pump impeller or interfere with the coolant path of fuel flow tube or primary plate type heat exchanger. The strainer was designed in accordance with ASME SEC. III, DIV. 1, Class 3 and the structural integrity was verified by seismic analysis. The screen was designed in accordance with the effective void area from the result of flow analysis for T-type strainer. After installation of the strainer, it was confirmed through the field test that the flow characteristics of primary cooling system were not adversely affected. The pressure loss coefficient was calculated by Darcy equation using the pressure difference through each strainer and the flow rate measured during the strainer performance test. And these are useful data to predict flow variations by the pressure difference.

  • PDF

A Study on Verification of PowerRail based on Voltage Drop under Extended Feeding Condition (연장급전 전압강하 계산을 위한 전기철도 급전 시뮬레이터의 검증에 관한 연구)

  • Kim, Joorak
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.2
    • /
    • pp.331-337
    • /
    • 2015
  • The power flow analysis of electrified railway is required complicated calculation, because of variable load. Train runs trough rail supplied by electric power therefore, the load value in electrified railway system fluctuates along time. The power flow algorithm in electrified railway system is different from general power system, and the power flow simulation is peformed by the particular simulation software. Powerail is simulation software for analysis of traction power supply system developed by KRRI, in 2008. This consists of load forecasting module, including TPS and time scheduling, and power flow module. This software was verified by measured current under normal feeding condition, however, has not been verified by voltage on the condition of extended feeding. This paper presents the verification of PowerRail based on voltage drop under extended feeding condition. This is performed by comparing simulation result with field test. Field test and simulation is done in commercial railway line.

Characteristics of flow-induced vibration for inner assembly of in-pile test section (노내시험부 내부집합체에 대한 유체유발진동특성)

  • Lee, Han-Hee;Lee, Jong-Min;Lee, Chung-Young
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.250-253
    • /
    • 2006
  • The in-pile Section (IPS) is subjected to flow-induced vibration(FIV) due to the flow of the primary coolant and then the structural integrity. The in-pile Section (IPS) of 3-pin Fuel Test Loop(FTL) shall be installed in the vortical hole call IR1 of HANARO reactor core. In order to verify the velocity and displacement both the inside region of IPS at the annular region of IPS, the vibration was measured by varing the flow rate on both regions. The displacements of fuel assembly in the in-pile Section (IPS) were found to be lower than the values of allowable design criteria.

  • PDF

Helium-Air Exchange Flow Through Openings with Vertical Partitions (수직평판을 삽입한 개구부의 헬륨 및 공기 치환류)

  • 강태일
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.3
    • /
    • pp.79-87
    • /
    • 2000
  • This paper describes experimental investigations of helium-air exchange flow through openings with vertical partitions. Such exchange flows may occur following rupture accident of stand pipe in high temperature gas cooled reactor. Exchange flow rates are investigated experimentally by using partitioned opening and opening with extended partition to assess fluids interference of the exchange flow at the stand pipe rupture accident. A tests vessel with the two types of opening on top of test cylinder is used in the experiments. An estimation method of mass increment is developed and applied to measure the exchange flow rate. A technique of flow visualization by Mach-Zehnder interferometer is provided to recognize the exchange flows. Amplitude and progress of interference fringes of the flows are observed and used as a support in comparison with the exchange flow rates. Flow passages of upward flow of the helium and downward flow of the air for both two types of the opening are separated by inserted partition within the opening, but in the case of partitioned opening, unseparated flow is formed at the opening entrance and the two flows interface. The exchange flow rate for the partitioned opening is not greater than that of the opening with extended partition because of the fluids interference at the entrance of opening. Finally, the fluids interference at the opening entrance is found to be one of important factors on the helium-air exchange flow rate.

  • PDF