• Title/Summary/Keyword: flow sensor

Search Result 882, Processing Time 0.027 seconds

Fabrication and Characteristics of Piezoresistive Flow Sensor with Microbeam Structures (미소 빔 구조를 가진 압저항형 유체센서의 제작 및 특성)

  • Park, Chang-Hyun;Kang, Sung-Gyu;Yu, In-Sik;Sim, Jun-Hwan;Lee, Jong-Hyun
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.5
    • /
    • pp.400-406
    • /
    • 1999
  • Piezoresistive flow sensors with four different types of microbeam structures were fabricated using (100), n/$n^+$/n three-layer silicon wafer and their characteristics were investigated. Piezoresistors were formed through boron diffusion and its values were about $1\;k{\Omega}$. Three-dimensional silicon microbeams were constructed by porous silicon micromachining and curled microbeams were fabricated by the difference in the thermal expansion coefficient between silicon and metal. The output response of the fabricated sensor was evaluated through half- bridge. The output voltage increased with increasing length of microbeam at the same flow velocity, while the detectable measurement range extended with decreasing length of microbeam. The output voltage of the fabricated sensors were increased with quotient of 3.2 of the flow rate since the stress of the beam versus the gas flow showed non-linear characteristics.

  • PDF

Human Activity Recognition using an Image Sensor and a 3-axis Accelerometer Sensor (이미지 센서와 3축 가속도 센서를 이용한 인간 행동 인식)

  • Nam, Yun-Young;Choi, Yoo-Joo;Cho, We-Duke
    • Journal of Internet Computing and Services
    • /
    • v.11 no.1
    • /
    • pp.129-141
    • /
    • 2010
  • In this paper, we present a wearable intelligent device based on multi-sensor for monitoring human activity. In order to recognize multiple activities, we developed activity recognition algorithms utilizing an image sensor and a 3-axis accelerometer sensor. We proposed a grid?based optical flow method and used a SVM classifier to analyze data acquired from multi-sensor. We used the direction and the magnitude of motion vectors extracted from the image sensor. We computed the correlation between axes and the magnitude of the FFT with data extracted from the 3-axis accelerometer sensor. In the experimental results, we showed that the accuracy of activity recognition based on the only image sensor, the only 3-axis accelerometer sensor, and the proposed multi-sensor method was 55.57%, 89.97%, and 89.97% respectively.

Mobile Robot Localization Using Optical Flow Sensors

  • Lee, Soo-Yong;Song, Jae-Bok
    • International Journal of Control, Automation, and Systems
    • /
    • v.2 no.4
    • /
    • pp.485-493
    • /
    • 2004
  • Open-loop position estimation methods are commonly used in mobile robot applications. Their strength lies in the speed and simplicity with which an estimated position is determined. However, these methods can lead to inaccurate or unreliable estimates. Two position estimation methods are developed in this paper, one using a single optical flow sensor and a second using two optical sensors. The first method can accurately estimate position under ideal conditions and also when wheel slip perpendicular to the axis of the wheel occurs. The second method can accurately estimate position even when wheel slip parallel to the axis of the wheel occurs. Location of the sensors is investigated in order to minimize errors caused by inaccurate sensor readings. Finally, a method is implemented and tested using a potential field based navigation scheme. Estimates of position were found to be as accurate as dead-reckoning in ideal conditions and much more accurate in cases where wheel slip occurs.

Development of Portable System for Measuring pH in Blood (휴대용 혈중pH 측정시스템의 구현)

  • 정도운;김우열;배진우;강성철;심윤보;전계록
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.195-198
    • /
    • 2001
  • We developed the portable blood analysis system, which can be measured pH of the blood. This system is composed to electronic circuit, mechanism, and system software. Electronic circuit is composed to the sensor, pre-amp part, temperature regulation part, fluid sensing part, A/D(analog to digital) conversion part, main and peripheral device processing part. And the mechanism is composed to the flow cell and the liquid flow part. The liquid flow part is consisted of blood and washing control system under the control of the 6-channel solenoid valve and syringe rump. The system software is composed to measurement program, calibration program, washing and diagnostic program. The program of each routine is designed as sequential process for an efficiency. And the portable pH analysis system used two-point calibration method using the two types of corrective liquid. As a result, we obtained the calibration curve and calculated the value of pH. For verifying the system, we confirmed the output voltage of the sensor, and estimated reappearance of system using the standard liquid.

  • PDF

An experimental study of flow separation around a circular cylinder with Reynolds number and free stream turbulence intensity variations (Reynolds수와 난류강도의 변화에 따른 실린더 주위 유동 박리점의 거동에 관한 실험적 연구)

  • Im,Yong-Seop;Son, Dong-Gi;Yang, Gyeong-Su;Lee, Jun-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.7
    • /
    • pp.889-898
    • /
    • 1998
  • The influences of the Reynolds number and free-stream turbulence intensity on the flow separation behavior around a circular were investigated experimentally. The range of the Reynolds number and turbulence intensity considered are 10,000 ~ 45,000 and 0.3 ~ 6.8%, respectively. Because of ineffectiveness of using time-mean value of hot-film sensor signals in determining the separation location around the cylinder, a new method using phase-difference of hot-film sensor signals with hot-wire being located in shedding vortex is suggested. The validity of the present method is confirmed by the comparison with flow visualization.

Performance Evaluation of Flow Injection Type Biosensor According to Operating Variables of Pump (펌프의 작동요인에 따른 흐름주입식 바이오센서의 성능 검증)

  • Song D. B.;Jung H. S.;Lee S. K.
    • Journal of Biosystems Engineering
    • /
    • v.30 no.5 s.112
    • /
    • pp.312-317
    • /
    • 2005
  • A flow injection type biosensor was tested to confirm the performance of a batch and a continuous type flow injection unit. Reproducibility and consistence of the biosensor were investigated to determine the effect of pulsations and air bubbles, and the applicability of on-line monitoring. The air bubbles affected the performance of the sensor irrespective of the location, and also the pulsations of the pump influenced the performance of the sensor. The applicability of on-line motoring was accepted as the result of the repeated and long-term measurements.

Drone Indoor position recognition and hovering technology based on optical flow for Finger printing (BLE Finger printing 연계를 위한 optical flow기반 Drone 실내 위치인식 및 호버링)

  • Lee, Joon beom;Lee, Dohee;Seo, Hyo-seung;Jo, Ju-yeon;Son, Bong-ki;Lee, Jae ho
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2016.04a
    • /
    • pp.86-87
    • /
    • 2016
  • 본 논문에서는 optical flow sensor를 이용하여 실내의 바닥 영상인식를 통한 영상처리기법을 이용해 움직임 없는 hovering을 할 수 있는 방법을 제안한다. 또한 optical flow와 BLE finger printing 기법을 혼합해 위치 인식 정밀도를 높일 수 있다. 본 고에서는 optical flow sensor와 BLE finger printing의 두 기술을 혼합하면 드론 스스로 실내에서 정밀도 높은 위치인식이 가능 하며 실외에서만 사용할 수 있는 GPS 비행모드를 대신 할 수 있어 실내에서 자동 경로 비행이 가능하게 하고 위치 안내, 실내 방송촬영, 이동식 CCTV등 질 높은 서비스를 제공하고자 한다.

Automatic Flow Control and Network Monitoring of IV Injection (자동 IV 주사 유량 자동 제어 및 네트워크 모니터링)

  • Kim, Jin-Nam;Kwon, Won-Tae;Lee, Kang-Hee
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.1
    • /
    • pp.161-166
    • /
    • 2012
  • Intravenous (IV) injection is widely used to supply Ringer solution directly into a vein in hospital. Generally, a passive injection method has been used, which causes the inconsistent flow rate of fluid and inappropriate control of injection time by a patient. It leads to an unnecessary nurse's overwork and decrement of IV injection's effect. To solve these problems, flow control infusion pumps have been developed. But because of relatively heavy weight and high price, its usage has been limited. In the present study, a new automatic IV injection system is developed. It is installed with a small pressing mechanism driven by a small electric motor to regulate the flow rate by pressing tube. Proportional integral derivative (PID) feedback control algorithm is applied to control the electric motor. The system is smaller in size and uses lower power than the existing commercial product. The newly developed system is also installed with networking capability, which enables monitoring the status of several automatic IV injection system at the same time.

Sensing characteristics of Polypyrrole-based methanol sensors preparedbyin-situ vapor state polymerization

  • Linshu Jiang;Jun, Hee-Kwon;Hoh, Yong-Su;Lee, Duk-Dong;Huh, Jeung-Soo
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.137-137
    • /
    • 2003
  • Conducting PPy/PVA composite and pure PPy gas sensors were prepared by in-situ vaporstate polymerization method in a vaporization chamber under N2 condition, by exposing the pre-coated electrode with PVA/FeC13 to distilled pyrrole monomer. The various electrical sensing behaviors of both types of sensors were systematically investigated by a flow measuring system including mass flow controller (MFC) and bubbling bottle. The FT-Raman spectroscopy of vapor state polymerized PPy was identical to that of chemically polymerized PPy, confirming the same chemical structure. Both types of sensors had positive sensitivity when exposed to methanol gas. The sensitivity varied linearly with gas concentration in the range of 50ppm to 1059ppm. The detection limit of PPy/PVA sensor was believed to be as low as 10ppm. The sensitivity of PPy/PVA composite sensor was higher than that of pure PPy sensor. Both the response time and recovery time of PPy/PVA composite sensors were longer than those of pure PPy sensors. The thickness of the sensing film affected the sensitivity this way that the sensor having thinner film had higher sensitivity, indicating that the resistance of polymer film involved in the sensing behavior was bulk resistance rather than surface resistance. The reproducibility of PPy/PVA composite sensor was excellent during eight on-off cycles by switching between N2 and 3000ppm methanol gas. The sensitivity of PPy/PVA composite sensor was only maintained for two weeks, while the sensitivity of pure PPy sensor was maintained over two months.

  • PDF

MDA-SMAC: An Energy-Efficient Improved SMAC Protocol for Wireless Sensor Networks

  • Xu, Donghong;Wang, Ke
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.10
    • /
    • pp.4754-4773
    • /
    • 2018
  • In sensor medium access control (SMAC) protocol, sensor nodes can only access the channel in the scheduling and listening period. However, this fixed working method may generate data latency and high conflict. To solve those problems, scheduling duty in the original SMAC protocol is divided into multiple small scheduling duties (micro duty MD). By applying different micro-dispersed contention channel, sensor nodes can reduce the collision probability of the data and thereby save energy. Based on the given micro-duty, this paper presents an adaptive duty cycle (DC) and back-off algorithm, aiming at detecting the fixed duty cycle in SMAC protocol. According to the given buffer queue length, sensor nodes dynamically change the duty cycle. In the context of low duty cycle and low flow, fair binary exponential back-off (F-BEB) algorithm is applied to reduce data latency. In the context of high duty cycle and high flow, capture avoidance binary exponential back-off (CA-BEB) algorithm is used to further reduce the conflict probability for saving energy consumption. Based on the above two contexts, we propose an improved SMAC protocol, micro duty adaptive SMAC protocol (MDA-SMAC). Comparing the performance between MDA-SMAC protocol and SMAC protocol on the NS-2 simulation platform, the results show that, MDA-SMAC protocol performs better in terms of energy consumption, latency and effective throughput than SMAC protocol, especially in the condition of more crowded network traffic and more sensor nodes.