• 제목/요약/키워드: flow resistance coefficient

검색결과 215건 처리시간 0.025초

커프 압력 조절에 따른 혈류량 변화 평가를 위한 임피던스법의 구현 (Implementation of Impedance Method to Estimate Blood Flow Variation with Cuff Pressure Change)

  • 정도운;배진우;손정만;예수영;최병철;남기곤;김철한;전계록
    • 센서학회지
    • /
    • 제13권6호
    • /
    • pp.462-472
    • /
    • 2004
  • In this study, we measured the blood flow on arm by non-invasive method and implemented a system to measure variation of the blood flow by estimating bio-electrical impedance and arterial pressure according to cuff pressure. The implemented system measured impedance variation according to pressure variation applied by artificial cuff pressure on the measuring position. The system consisted of pressure measuring part and impedance measuring part using 4-electrode method. Pressure measuring part was composed of semiconductor pressure sensor and electronic circuit for signal processing of sensor output signal. In addition, impedance measuring part was composed of constant current source circuit and lock-in amplifier for detecting impedance signal. We conducted experiments of impedance measuring part using standard resistance for performance evaluation of the implemented system. In addition we experimented to estimate variation of the blood flow by measuring impedances of the experimental group. We estimated ratio of the blood flow resistance using mean arterial pressure and variation of the blood flow. As a result the ratio of the blood flow resistance and variation of blood flow were in an inverse relationship with each other and the correlation coefficient was -0.96776.

다공판 시스템의 흡음성능에 유동이 미치는 영향 (The effect of the flow on the absorption performance of a perforated plate system)

  • 허성욱;제현수;양수영;이동훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.879-884
    • /
    • 2003
  • This paper is to experimentally investigate the effect of the through-flow and grazing-flow on the absorption performance of a perforated plate system. The experiment is performed through the systematic change of the through-flow velocity, grazing-flow velocity, incident sound pressure level, and the geometrical parameters such as the porosity and hole diameter. From the experimental results, it is found that for the nonlinear relationship between the acoustic resistance and incident sound pressure level there is no influence of the through-flow on the absorption performance, but fur the linear relationship between them there is a strong dependence of the absorption performance on the through-flow velocity. It is also shown that the absorption performance is controllable by changing the porosity and hole-diameter in size.

  • PDF

굴뚝의 우수유입방지 특성 (Characteristics of Rainfall Protection for Stacks)

  • 김종철;김태형
    • 한국산업보건학회지
    • /
    • 제10권1호
    • /
    • pp.18-31
    • /
    • 2000
  • A stack must be designed to 1) reduce or eliminate rainfall or snowfall into a industrial exhaust system, 2) minimize a resistance to flow, 3) maximize the vertical dispersion of the contaminated air and 4) minimize maintenance. The weather cone stacks and the elbow-type stacks are very popular in Korea. But they add some resistance to the exhaust system resulting in reduction of air flow rate, but also deflect the noxious contaminants downward in undiluted form. To solve these problems, ACGIH (American Conference of Governmental Industrial Hygienists) suggested the vertical discharge stack with concentric space between the upper stack with larger diameter and the lower stack with smaller diameter. The preliminary test showed that the vertical discharge stacks did not have the good rainfall protection. The reversed cone were newly devised to satisfy the requirements for the good stack. Subsequently, the amount of rain being penetrated through the stacks was measured while the stacks were simultaneously and naturally exposed to rain in the same area outside. Test results indicate that none of the stacks tested completely exclude rain. The efficiency of rainfall protection and the pressure loss coefficient were compared. The temporary conclusion was reached to the point that the reversed cone stack is the best one. Further research is underway.

  • PDF

임피던스법을 이용한 혈류량 변화 측정 (Measurement of Blood Flow Variation using Impedance Method)

  • 정도운;강성철;전계록
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2006년도 춘계종합학술대회
    • /
    • pp.693-696
    • /
    • 2006
  • 본 연구에서는 생체 임피던스의 변화를 계측하여 혈류량의 변화를 추정하기 위한 시스템을 구현하였다. 구현된 시스템은 인위적인 압력을 가하여 압력의 변화에 따른 임피던스의 변화량을 측정할 수 있도록 구성하였으며, 크게 압력 측정부와 4 전극법을 이용한 임피던스 측정부로 구분할 수 있다. 압력 측정부는 반도체식 압력센서와 센서의 출력신호를 처리하기 위한 전자회로부로 구성하였고, 임피던스 측정부는 교류 정전류원 회로와 임피던스 신호의 검출을 위한 락인 증폭기로 시스템을 구성하였다. 구현된 시스템의 성능평가를 위하여 표준저항을 이용한 임피던스 측정부의 특성조사 실험을 수행 하였다. 그리고 실제 실험군을 대상으로 임피던스의 계측을 통한 혈류량 변화 추정실험을 수행하였고, 혈류량 변화와 평균 동맥압을 이용한 혈류 저항비를 추정하였다 그 결과 혈류저항비와 혈류량의 변화는 반비례관계를 명확하게 보여 주었으며, 상관분석을 수행한 결과 상관계수가 -0.96776으로 강한 음의 상관관계를 나타내었다.

  • PDF

동전위 분극저항 측정에서의 불확도 (Uncertainty in Potentiodynamic Polarization Resistance Measurement)

  • 김종집
    • Corrosion Science and Technology
    • /
    • 제8권5호
    • /
    • pp.193-196
    • /
    • 2009
  • For the estimation of uncertainty in potentiodynamic polarization resistance measurement, the type A uncertainty was measured using type 316 stainless steel in an acidified NaCl solution. Sensitivity coefficients were determined for measurand such as scan rate of potential, temperature of solution, concentration of NaCl, concentration of HCl, surface roughness of specimen and flow rate of purging gas. Sensitivity coefficients were large for the measurand such as the scan rate of potential, temperature of solution and roughness of specimen. However, the sensitivity coefficients were not the major factors influencing the combined standard uncertainty of polarization resistance due to the low values of uncertainty in measurements of the measurands. A major influencing factor was the concentration of NaCl. The value of type A uncertainty was 1.1 times the value of type B uncertainty, and the combined standard uncertainty was 10.5 % of the average value of polarization resistance.

비 Froude수에 있어서 선체의 조파저항 (Wave Resistance of a Ship at Low Froude Numbers)

  • 김인철
    • 수산해양기술연구
    • /
    • 제17권2호
    • /
    • pp.109-113
    • /
    • 1981
  • Most existing theories on ship waves and wave resistance are based on the perturbation of the flow field by a small pararr.eter which specifies the slenderness of the ship hull. Since however, ship hulls in practice are neither so slender nor thin enough to secure the validity of the linearized theory, the agreen:ent between the theoretical prediction and the experimental result is not generally satisfactory. The author pointed out that the contribution by the non-linear term in the free surface condition can be represented by sorr.e source distribution over the still water plane. This paper leads to a forrr.ula for the wave resistance of not slender ships at low Froude nurr.bers. and deals with the asynptotic expression. As a nurr.erical example, the wave resistance of Wigley model is calculated, and the result is compared with experimental values. It is concluded that the wave resistance coefficient varies in the rate of Fn6 at low speed limit in general. A comparison with the result derived from the linearized free surface condition shows that the non-linearity of the free surface is irr portant at low speed.

  • PDF

천수에서 전진하는 선박의 선체 및 추진기 주위 유동 수치 해석 (NUMERICAL ANALYSIS OF THE FLOW AROUND THE HULL AND THE PROPELLER OF A SHIP ADVANCING IN SHALLOW WATER)

  • 박일룡
    • 한국전산유체공학회지
    • /
    • 제20권4호
    • /
    • pp.93-101
    • /
    • 2015
  • This paper provides numerical results of the simulation for the flow around the hull and the propeller of KCS model ship advancing in shallow water conditions. A finite volume method is used to solve the unsteady Reynolds averaged Navier-Stokes(RANS) equations, where the wave-making problem is solved by using a volume-of-fluid(VOF) method. The wave formed near the hull surface in shallow water conditions shows a deep trough dominant pattern that causes the loss of buoyancy followed by hull squat. The flow past the hull increases as the depth of water decreases. However, the axial flow velocity around the stern shows a reduction in magnitude by the effect of shallow water accompanied by the hull-propeller interaction. As a results, the thrust and torque coefficient increase about 8.3% and 6.2%, respectively for a depth of h/T=3.0 corresponding to a depth Froude number of $F_h=0.693$. The resistance coefficient increases about 11.6% at this Froude number condition.

고정밀 저항용 질화탄탈 박막의 특성 (Characteristic of Tantalum Nitride Thin-films for High Precision Resistors)

  • 최성규;나경일;남효덕;정귀삼
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.537-540
    • /
    • 2001
  • This paper presents the characteristics of Ta-N thin-film for high precision resistors, which were deposited on Si substrate by DC reactive magnetron sputtering in an argon-nitrogen atmosphere(Ar-(4~16 %)$N_2$). Structural properties studied using X-ray diffraction(XRD) indicate the presence of TaN, $Ta_3N_5$ or a mixture of Ta-N phases in the films depending on the amount of nitrogen in the sputtering gas. The chemical composition are investigated by auger electro spectroscopy(AES). The optimized conditions of Ta-N thin-film resistors were deposited in 4 % $N_2$ gas flow ratio. Under optimum conditions, the Ta-N thin-film resistors are obtained a high resistivity, $\rho=305.7{\mu}{\Omega}cm$, a low temperature coefficient of resistance, TCR=-36 $ppm/^{\circ}C$.

  • PDF

고정밀 저항용 질화탄탈 박막의 특성 (Characteristic of Tantalum Nitride Thin-films for High Precision Resistors)

  • 최성규;나경일;남효덕;정귀상
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.537-540
    • /
    • 2001
  • This paper presents the characteristics of Ta-N thin-(ibm for high precision resistors, which were deposited oni substrate by DC reactive magnetorn sputtering in an argon-nitrogen atmosphere(Ar-(4∼16%)N$_2$). Sturcutural properties sutided using X-ray diffraction (XRD) indicate the presence of TaN, Ta$_3$N$\sub$5/ or a mixture of Ta-N phases in the films depending on the amount of nitrogen in the sputtering gas. The chemical composition are investigated by auger electro spectroscopy(AES). The optimized conditions of Ta-N thin-film resistors were deposited in 4 % N$_2$ gas flow ratio. Under optimum conditions, the Ta-N thin-film resistors are obtained a high resistivity, $\rho$=305.7 ${\mu}$Ωcm, a low temperature coefficient of resistance, TCR=-36 ppm/$^{\circ}C$.

  • PDF

고온 스트레인 게이지용 질화탄탈박막의 제작 (Fabrication of Tantalum Nitride Thin-Film as High-temperature Strain Gauges)

  • 김재민;최성규;남효덕;정귀상
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.97-100
    • /
    • 2001
  • This paper presents the characteristics of Ta-N thin-film strain gauges as high-temperature strain gauges, which were deposited on Si substrate by DC reactive magnetron sputtering in an argon-nitrogen atmosphere(Ar-(4∼16 %)N$_2$). These films were annealed for 1 hour in 2x10$\^$-6/ Torr vaccum furnace range 500∼1000$^{\circ}C$. The optimized conditions of Ta-N thin-film strain gauges were annealing condition(900$^{\circ}C$, 1 hr.) in 8% N$_2$ gas flow ratio deposition atmosphere. Under optimum conditions, the Ta-N thin-films for strain gauges is obtained a high resistivity, $\rho$=768.93 ${\mu}$Ω cm, a low temperature coefficient of resistance, TCR=-84 ppm/$^{\circ}C$ and a high temporal stability with a good longitudinal gauge factor, GF=4.12.

  • PDF